• Title/Summary/Keyword: 평판 검출기

Search Result 61, Processing Time 0.028 seconds

Evaluation of Image Quality for Scattered X-rays using in Digital Radiography (디지털방사선영상에서 산란선의 영상특성 평가)

  • Kim, Hansol;Kim, Changsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.395-403
    • /
    • 2022
  • Flat-panel detector (FPD) used in digital radiographic imaging systems was used to perform a quantitative power spectrum evaluation as a result of the thickness change of polymethyl methacrylate (PMMA), a tissue equivalent. As the PMMA thickness increases with the resolution-chart phantom image, the effect of the scattering line increases, indicating that the modulation characteristics decrease, and the image is bright. The results show that the noise of the image increases, and noise-power spectral images are obtained by Fourier transform to confirm by spatial frequency. Thus, it can be verified that the PMMA thickness and noise are proportional through the result of evaluating the change of resolution characteristics and representing the 2D noise-power spectrum as one-dimensional values by evaluating the change of scattering line with MTF as the PMMA thickness increases in the image.

Dose Effect of Tissue Compensator for 6 MV X-Ray (두경부 방사선조사시 3차원조직보상체에 의한 피부선량)

  • Lee, Ho-Jun;Choi, Tae-Jin;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.10 no.2
    • /
    • pp.147-153
    • /
    • 1992
  • It is ideal thing to compensate tissue deficit without skin contamination in curvatured irradiation field of high energy photon beam. The 3-dimensional compensating technique utilizing tissue equivalent materials to ensure an adequate dose distribution and skin sparing effect was described. This compensator was made of paraffin ($70\%$) and stearin wax ($30\%$) compound. The parameters for evaluation of the effect on skin dose in application of compensator were considered in the size of the field, the thickness of the compensator and the source-to-axis distance. The results are as follows; the skin doses were not changed even though application of the compensator, but depended on the field size and the source-to-axis distance, and the skin doses were only slightly changed within $1\%$ relative errors as increasing the thickness of the compensator in these experiments.

  • PDF

A semi-selective agar medium to detect the presence of the causal agent of anthracnose, Colletotrichum scovillei, in chilli pepper (고추에서 탄저병균 Colletotrichum scovillei를 검출하기 위한 반선택 배지)

  • Sung Kee Hong;Se-Keun Park;Hyo-Weon Choi;Hyunjoo Ryu
    • Korean Journal of Environmental Biology
    • /
    • v.39 no.4
    • /
    • pp.479-485
    • /
    • 2021
  • A semi-selective agar medium was developed for detecting and enumerating Colletotrichum scovillei in chili (Capsicum annum) plant material. Potato-dextrose-agar(PDA) was used as the basic medium. The composition of the semi-selective agar medium was established after several attempts to favor the development of C. scovillei and inhibit the growth of other fungi and bacteria. The semi-selective agar medium contained PDA amended with pyribencarb and pydiflumetofen at 40 ㎍ mL-1 each and streptomycin at 100㎍ mL-1 for preventing bacterial growth. The pH was adjusted to 4.8 with 85% lactic acid. The inhibition of the mycelial growth of C. scovillei was significantly less than that of most other fungi including Fusarium species when grown on the semi-selective medium. C. scovillei was detected from naturally infected chili plants by plating fruit and stem tissue suspensions on the semi-selective medium, which was found to be reliable and quantifiable. This was the first report of a semi-selective agar medium to detect the presence of C. scovillei in naturally infected chili tissue.

A study on electrical response property of photoconductor film for x-ray imaging sensor (X선 영상센서 적용을 위한 광도전체 필름의 전기적 응답특성 연구)

  • Kang, Sang-Sik;Kim, Chan-Wook;Lee, Mi-Hyun;Lee, Kwang-Ok;Moon, Yong-Soo;An, Sung-A;No, Ci-Chul;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.4
    • /
    • pp.29-33
    • /
    • 2009
  • Recently, the compound materials(a-Se, $HgI_2$, PbO, CdTe, $PbI_2$, etc.) that are used in flat panel x-ray imager have been studied for digital x-ray imaging. In this paper, the signal detection properties of $HgI_2$ and a-Se conversion layer, are compared. The thick $HgI_2$ film is fabricated by special particle-in-binder method and the conventional vacuum thermal evaporation is used for a deposition of a-Se film. And an electrical characteristic measurements were investigated about leakage current, signal response property and x-ray sensitivity. From the experimental results show that the $HgI_2$ film has a low operation voltage and high signal generation than that of a-Se.

  • PDF

Investigation of Physical Imaging Properties in Various Digital Radiography Systems (다양한 디지털 방사선 시스템의 물리적 영상 특성 조사)

  • Jeong, Hoi-Woun;Min, Jung-Hwan;Yoon, Yong-Su;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.363-370
    • /
    • 2017
  • We aimed to evaluate the physical imaging properties in various digital radiography systems with charged coupled device (CCD), computed radiography (CR), and indirect flat panel detector (FPD). The imaging properties measured in this study were modulation transfer function (MTF) wiener spectrum (WS), and detective quantum efficiency (DQE) to compare the performance of each digital radiography system. The system response of CCD were in a linear relationship with exposure and that of CR and FPD were proportional to the logarithm of exposure. The MTF of both CR and FPD indicated a similar tendency but in case of CCD, it showed lower MTF than that of CR and FPD. FPD showed the lowest WS and also indicated the highest DQE among three systems. According to the results, digital radiography system with different type of image receptor had its own image characteristics. Therefore, it is important to know the physical imaging characteristics of the digital radiography system accurately to obtain proper image quality.

A Computer Simulation for Small Animal Iodine-125 SPECT Development (소동물 Iodine-125 SPECT 개발을 위한 컴퓨터 시뮬레이션)

  • Jung, Jin-Ho;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jeong, Myung-Hwan;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.74-84
    • /
    • 2004
  • Purpose: Since I-125 emits low energy (27-35 keV) radiation, thinner crystal and collimator could be employed and, hence, it is favorable to obtain high quality images. The purpose of this study was to derive the optimized parameters of I-125 SPECT using a new simulation tool, GATE (Geant4 Application for Tomographic Emission). Materials and Methods: To validate the simulation method, gamma camera developed by Weisenberger et al. was modeled. Nal(T1) plate crystal was used and its thickness was determined by calculating detection efficiency. Spatial resolution and sensitivity curves were estimated by changing variable parameters for parallel-hole and pinhole collimator. Peformances of I-125 SPECT equipped with the optimal collimator were also estimated. Results: in the validation study, simulations were found to agree well with experimental measurements in spatial resolution (4%) and sensitivity (3%). In order to acquire 98% gamma ray detection efficiency, Nal(T1) thickness was determined to be 1 mm. Hole diameter (mm), length (mm) and shape were chosen to be 0.2:5:square and 0.5:10:hexagonal for high resolution (HR) and general purpose (GP) parallel-hole collimator, respectively. Hole diameter, channel height and acceptance angle of pinhole (PH) collimator were determined to be 0.25 mm, 0.1 mm and 90 degree. The spatial resolutions of reconstructed image of the I-125 SPECT employing HR:GP:PH were 1.2:1.7:0.8 mm. The sensitivities of HR:GP:PH were 39.7:71.9:5.5 cps/MBq. Conclusion: The optimal crystal and collimator parameters for I-125 Imaging were derived by simulation using GATE. The results indicate that excellent resolution and sensitivity imaging is feasible using I-125 SPECT.

A analysis on the satellite tracking performance of Az mount on shipboard (선박탑재 Az mount의 위성추적 성능에 대한 분석)

  • 최조천;주양로
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.132-137
    • /
    • 2003
  • This performance is motivated to develop a tracking antenna system for receive the satellite broadcasting signal in the coast sailing ship. Therefore, this system is made to small size, light weight and simple operation which is must to low cost system for popularization of small size ship and adaptive possibilities with useful on a ship in the coast using 1 axis Az-mount. The antenna mount structure is a compact size and easy operation to the Az-axis type which is operated by step motor. The antenna unit is a domestic made plate type of patch array and ship's moving detection is using the gyro sensor for ship's moving control. We are designed to algorithm, which walking is abreast for step track and ship's moving compensation. Ship's moving compensation is adapted to the closed loop control method by detection from gyro sensor. This system is consisted of micro processor, ADC, comparative amplifier, step motor driver, mount mechanism and algorithm. We have analysised the tracking performance of prototype on sailing ship board.

  • PDF

A analysis on the satellite tracking performance of Az mount on shipboard (선박탑재 Az mount의 위성추적 성능에 대한 분석)

  • 최조천
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.6
    • /
    • pp.1130-1137
    • /
    • 2003
  • This performance is motivated to develop a tracking antenna system for receive the satellite broadcasting signal in the coast sailing ship. Therefore, this system is made to small size, light weight and simple operation which is must to low cost system for popularization of small size ship and adaptive possibilities with useful on a ship in the coast using 1 axis Az-mount. The antenna mount structure is a compact size and easy operation to the Az-axis type which is operated by step motor. The antenna unit is a domestic made plate type of patch array and ship's moving detection is using the gyro sensor for ship's moving control. We are designed to algorithm, which walking is abreast for step track and ship's moving compensation. Ship's moving compensation is adapted to the closed loop control method by detection from gyro sensor. This system is consisted of micro processor, ADC, comparative amplifier, step motor driver, mount mechanism and algorithm. We have analysised the tracking performance of prototype on sailing ship board.

Measurement and Analysis of Electric Filed Distributions under 154[kV] Overhead Tranamission Lines (154[KV] 가공송전선로 아래에서 전장분포의 측정과 분석)

  • 이복희;이정기;안창환;이경옥;박동화;곽희로;송진호
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.1
    • /
    • pp.92-98
    • /
    • 1997
  • In this paper, the results of the measurement and analysis of extremely low freqency(ELF) eletric field in the vicinity of 154[kV] overhad transmission lines have been described. The planar-type electric field sensor has been fabricated by three dimensional structure with special consideration of taking the power frequency and lower components. The calibration experiments have been carried out according to the procedures of IEEE recommendation. The electric field measuring system has the frequency bandwidth of 7[Hz] to 2.7[MHz] and the response sensitivity of 0.094[mV/V/m]. Also the practical measurements of electric field under an 154[kV] double corcuit overhead transmission lines have been made abd abalyzed. It was known that the lateral electric field profiles under an 154[kV] double circuit overhead transmission lines show the asymmetrical distributions owing to the environmental metal frame structures and their maximum electric field magnitude is less than 3[kV/m]. It can be concluded that the measured results of the electric fields satisfy with all limits or guide -lines of the various authorized international institutes' recommendations.

  • PDF

Management of Critical Control Points to Improve Microbiological Quality of Potentially Hazardous Foods Prepared by Restaurant Operations (외식업체에서 제공하는 잠재적 위험 식품의 미생물적 품질향상을 위한 중점관리점 관리방안)

  • Chun, Hae-Yeon;Choi, Jung-Hwa;Kwak, Tong-Kyung
    • Korean journal of food and cookery science
    • /
    • v.30 no.6
    • /
    • pp.774-784
    • /
    • 2014
  • The purpose of this study was to present management guidelines for critical control points by analyzing microbiological hazardous elements through screening Potentially Hazardous Foods (PHF) menus in an effort improve the microbiological quality of foods prepared by restaurant operations. Steamed spinach with seasoning left at room temperature presents a range of risk temperatures which microorganisms could flourish, and it exceeded all microbiological safety limits in our study. On the other hand, steamed spinach with seasoning stored in a refrigerator had Aerobic Plate Counts of $2.86{\pm}0.5{\log}\;CFU/g$ and all other microbiological tests showed that their levels were below the limit. The standard plate counts of raw materials of lettuce and tomato were $4.66{\pm}0.4{\log}\;CFU/g$ and $3.08{\pm}0.4{\log}\;CFU/g$, respectively. Upon washing, the standard plate counts were $3.12{\pm}0.6{\log}\;CFU/g$ and $2.10{\pm}0.3{\log}\;CFU/g$, respectively, but upon washing after chlorination, those were $2.23{\pm}0.3{\log}\;CFU/g$ and $0.72{\pm}0.7{\log}\;CFU/g$, respectively. The standard plate counts of baby greens, radicchio and leek were $6.02{\pm}0.5{\log}\;CFU/g$, $5.76{\pm}0.1{\log}\;CFU/g$ and $6.83{\pm}0.5{\log}\;CFU/g$, respectively. After 5 minutes of chlorination, the standard plate counts were $4.10{\pm}0.6{\log}\;CFU/g$, $5.14{\pm}0.1{\log}\;CFU/g$ and $5.30{\pm}0.3{\log}\;CFU/g$, respectively. After 10 minutes of chlorination treatment, the standard plate counts were $2.58{\pm}0.3{\log}\;CFU/g$, $4.27{\pm}0.6{\log}\;CFU/g$, and $4.18{\pm}0.5{\log}\;CFU/g$, respectively. The microbial levels decreased as the time of chlorination increased. This study showed that the microbiological quality of foods was improved with the proper practices of time-temperature control, sanitization control, seasoning control, and personal and surface sanitization control. It also presents management guidelines for the control of potentially hazardous foods at the critical control points in the process of restaurant operations.