A Study on the Concentration Polarization Layer Resistance in Ultrafiltration of Macromolecular Solutions (고분자 용액의 한외여과에서 농도분극층 저항에 관한 연구)

  • 염경호
    • Membrane Journal
    • /
    • v.2 no.1
    • /
    • pp.59-66
    • /
    • 1992
  • The experimental studies were carried out on ultrafiltration of PEG #6000 and dextran 70T macromole¬cules. using an asymmetric cellulose acetate membrane in a cross flow plane type cell. Effects of pressure difference. feed concentration were studied on permeate flux and observed rejection for both the macromole¬cules. and the concentration polarization layer resistance $R_{b1}$ on permeate flux was analysed. The concentration polarization layer resistance $R_{b1}$ was correlated with the average macromolecule concen¬tration $C_{b1}$ in polarization layer. The resulting dimensionless correlation was expressed as : $\frac{R_{b1}}{{R_m}}=\alpha[\frac{\rho_{b1}}{C_{b1}}]^\beta$

  • PDF

A Study on the Ultrafiltration of a Cutting Oil Emulsion (절삭유 에멀젼의 한외여과분리 연구)

  • 김광제;박인준;김동권;이수복
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.10a
    • /
    • pp.31-32
    • /
    • 1995
  • 한외여과분리의 중요한 응용분야의 하나인 oil/water 에멀젼의 분리에 대하여 연구하였다. Oil/water 에멀젼의 한외여과분리 원리를 제안하고, 상용되고 있는 하나의 절삭유를 대상으로 분리가능성을 조사하였다. 사용된 한외여과분리 모듈은 상업적으로 이용되고 있는 IRIS 3042 분리막이 장착된 평판형이었다. 한외여과 실험에서 공급압력, 공급유량, 공급에멀젼의 oil농도등을 변화시키면서 투과액의 oil농도, 투과속도등을 측정하여 분리성능을 조사하였다.

  • PDF

Performance Analysis of Plate-and-Frame Forward Osmosis Membrane Module for Concentrating High Salinity Wastewater (고염도 폐수 농축을 위한 평판형 정삼투막 모듈의 성능 분석)

  • Kim, Yu Chang;Lee, Sungyun;Park, Sang-Jin;Kim, Han Seok
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.6
    • /
    • pp.68-74
    • /
    • 2016
  • Hydraulic fracturing of wells during oil and gas (O&G) exploration consumes large volumes of fresh water and generates larger volumes of contaminated wastewater with high salinity. It is critical to treat and reuse the O&G wastewater in a cost-effective and environmentally sound manner for sustainable industrial development and for meeting stringent regulations. Recently, forward osmosis (FO) has been examined if it is a promising solution for treatment and desalination of complex industrial streams and especially fracturing flowback and produced waters. In the present study, the performances of a plate-and-frame FO membrane element and a module (6 elements combined in series) were investigated for concentrating high TDS wastewater. An FO module has achieved up to 64 % water recovery (i.e., concentration factor of 2.76) from 10,000 ppm wastewaters and can concentrate feed streams salinities to greater than 30,500 ppm.

Simulation of Pervaporation Process Through Hollow Fiber Module for Treatment of Reactive Waste Stream from a Phenolic Resin Manufacturing Process (페놀수지 생산공정에서 배출되는 반응성 폐수처리를 위한 중공사막 모듈 투과증발 공정모사)

  • C. K Yeom;F. U. Baig
    • Membrane Journal
    • /
    • v.13 no.4
    • /
    • pp.257-267
    • /
    • 2003
  • For the treatment of reactive phenolic resin waste, a simulation model of pervaporative dehydration process has been developed through hollow fiber membrane module. Some of basic parameters were determined directly from dehydration of the waste liquid through a flat sheet membrane to get realistic values. The simulation model was verified by comparing the simulated values with experimental data obtained from hollow fiber membrane module. Hollow fiber membranes with active layer coated on inside fiber were used, and feed flew through inside hollow fiber. Feed flow rate affected membrane performances and reaction by providing a corresponding temperature distribution of feed along with fiber length. Feed temperature is also a crucial factor to determine dehydration and reaction behavior by two competing ways; increasing temperature increases permeation rate as well as water formation rate. Once the permeate pressure is well below the saturated vapor pressure of feed, permeate pressure had a slightly negative effect on permeation performance by slightly reducing driving force. As the pressure approached the vapor pressure of feed, dehydration performances declined considerably due to the activity ratio of feed and permeate.

Experimental Evaluation of Hydrophilic Membrane Humidifier with Isolation of Heat Transfer Effect (친수성 막을 통한 수분 전달 특성 연구)

  • Tak, Hyun Woo;Kim, Kyoung Teck;Han, Jae Young;Im, Seok Yeon;Yu, Sang Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.9
    • /
    • pp.815-821
    • /
    • 2013
  • The efficiency and lifetime of a polymer electrolyte membrane fuel cell (PEMFC) system is critically affected by the humidity of the incoming gas, which should be maintained properly under normal operating conditions. Typically, the incoming gas of a fuel cell is humidified by an external humidifier, but few studies have reported on the device characteristics. In this study, a laboratory-scale planar membrane humidifier is designed to investigate the characteristics of water transport through a hydrophilic membrane. The planar membrane humidifier is immersed in a constant temperature bath to isolate the humidifier from the effect of temperature variations. The mass transfer capability of the hydrophilic membrane is first examined under isothermal conditions. Then, the mass transfer capability is investigated under various conditions. The results show that water transport in the hydrophilic membrane is significantly affected by the flow rate, operating temperature, operating pressure, and flow arrangement.

X-ray properties measurement of Flat panel Digital X-ray gas detector (평판형 디지털 엑스레이 가스 검출기의 엑스선 특성 측정기술에 관한 연구)

  • Yoon, Min-Seok;Cho, Sung-Ho;Oh, Kyung-Min;Jung, Suk-Hee;Nam, Sang-Hee;Park, Ji-Goon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.1
    • /
    • pp.17-21
    • /
    • 2009
  • The Recently, large area matrix-addressed image detectors are investigated for X-ray imaging with medical diagnostic and other applications. In this paper, a new flat panel gas detector for diagnostic X-ray imaging is proposed, and its characteristics are investigated. The research of flat panel gas detector is not exist at all. Because of difficulty to inject gas against to atmospheric pressure. So almost gas detector made by chamber shape. We made flat panel sample by display technique. (ex: PDP, Fed, etc.) The experimental measurements, the transparent electrodes, dielectric layer, and the MgO protection layer were formed in front glass. And, the X-ray phosphor layer and address electrodes are formed in the rare glass. The dark current, the x-ray sensitivity and linearity as a function of electric field were measured to investigate the electrical properties. From the results, the stabilized dark current density and the significant x-ray sensitivity were obtained. And the good linearity as a function of exposure dose was showed in wide diagnostic energy range. These results means that the passive matrix-addressed flat panel gas detector can be used for digital x-ray imaging.

  • PDF

Permeation Characteristics of the Plate & Frame Membrane Module with Protuberances (돌기형 평판 분리막 모듈의 투과특성)

  • Chung, Kun-Yong;Jeon, Sung-Il
    • Membrane Journal
    • /
    • v.18 no.2
    • /
    • pp.168-175
    • /
    • 2008
  • This study was carried out for the plate and frame membrane modules equipped with and without plastic protuberances on the support frame in order to determine the effect of eddy flow induced by the protuberances on permeate flux. The initial time for rapidly declined permeate flux on the module with protuberances was delayed twice or more than that on the module without protuberances when kaolin solution was permeated at the operating pressures from 0.4 to 1.6 bar. Also decreasing ratio of the kaolin solution to pure water flux for module with protuberances was 1 to 5% lower than that for module without protuberances. The flux improvement due to protuberances at laminar flow corresponding Reynolds number 1,750 was about double as compared with that in the transition flow region. In general, the kaolin fouling reduction for the plate module with protuberances during initial filtration process was very effective, even though the permeate flux after 60 minutes filtration did not increase significantly.

A Study on the High Selective Oxide Etching using Inductively Coupled Plasma Source (유도결합형 플라즈마원을 이용한 고선택비 산화막 식각에 관한 연구)

  • 이수부;박헌건;이석현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.4
    • /
    • pp.261-266
    • /
    • 1998
  • In developing the high density memory device, the etching of fine pattern is becoming increasingly important. Therefore, definition of ultra fine line and space pattern and minimization of damage and contamination are essential process. Also, the high density plasma in low operating pressure is necessary. The candidates of high density plasma sources are electron cyclotron resonance plasma, helicon wave plasma, helical resonator, and inductively coupled plasma. In this study, planar type magnetized inductively coupled plasma etcher has been built. The density and temperature of Ar plasma are measured as a function of rf power, flow rate, external magnetic field, and pressure. The oxide etch rate and selectivity to polysilicon are measured as the above mentioned conditions and self-bias voltage.

  • PDF

Optical Waveguiding in the Polymerized Organic Films (유기물 박막에서의 광도파 현상)

  • 박홍준;권영세
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.19 no.5
    • /
    • pp.5-11
    • /
    • 1982
  • The dielectric slab waveguide is fabricated on the slide glass or oxidized silicon wafer, by spin coating polyurethane, epoxy or photoresist, and the phenomenon of dielectric waveguiding is oboerved. Using the fact that the refractive index of K.P.R. is larger than that of polyurethane, thin film prism with two layered structure is fabricated, and the refraction of light is observed.

  • PDF

비정질 실리콘 박막 증착용 고밀도 플라즈마 화학 증착장비

  • 김창조;최윤;김도천;신진국;이유진
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2003.05a
    • /
    • pp.1-3
    • /
    • 2003
  • 평판형 안테나를 채택한 TCP (Transformer Coupled Plasma) 형태의 CVD 장비를 이용하여 비정질의 실리콘 박막을 증착 하였다. 비정질 실리콘 박막은 태양전지 및 TFT-LCD 등의 디스플레이 제품 등에 다양하게 적용되고 있는데, 일반적으로 CCP(Capacitor Coupled Plasma) 형태의 CVD 장비에서 증착되어 왔다. TCP-CVD 장비는 CCP-CVD에 비해 플라즈마 내의 높은 이온밀도 및 저압, 저온에서 공정이 가능할 뿐만 아니라, 기판 바이어스 전압을 독립적으로 조절할 수 있어 이은에 의한 증착막의 결함을 낮출 수 있는 장점이 있다. 본 발표에서는 자체 기술로 제작된 TCP-CVD의 소개와 증착된 비정질 실리콘 박막의 특성평가를 위한 라만 분석 및 dark conductivity 데이타를 다루었다. 또한 비정질 실리콘 박막의 반도체 소자의 응용성을 보기 위하여 3족 및 5족의 불순물을 도핑하여 전기전도도의 변화를 측정하였다.