A Study on the Flow Characteristics of a Two - Dimensional Oblique Plate Impinging Jet (경사진 평판에서 2차원 충돌 제트의 유동 특성에 관한 연구)

  • 윤순현;김경문;김대성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.1
    • /
    • pp.37-42
    • /
    • 1997
  • Turbulent flow characteristics of a two - dimensional oblique plate impinging jet(OPIJ) were experimentally investigated. The jet mean velocity and turbulent intensity profIles were also measured along the plate. The jet Reynolds numbers(Re, based on the nozzle width)ranged from 10, 000 to 35, 000, the nozzle - to - plate distance(H/B) from 2 to 16, and the oblique angle (a) from 60 to 90 degree. It has been found that the stagnation point shifted toward the minor flow region as the oblique angle decreases and the position of the stagnation point nearly coin¬cided with that of the maximum turbulent intensity.

  • PDF

Experimental Study on Turbulent Structure of Flow over a Micro Riblet Plate (미세 Riblet 평판에서의 난류구조 변화에 관한 실험적 연구)

  • Choi, Yong-Seok;Lee, Sang-Joon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.375-376
    • /
    • 2006
  • Turbulent structure of a boundary-layer over a flat plate coated with micro riblet film(MRF) has been investigated experimentally. The turbulent structure was visualized using a dynamic particle image velocimetry (Dynamic PIV) system. We identified the vortex structures from 2-D velocity field data by applying the complex eigenvalue definition. The velocity field images acquired by using the complex eigenvalue definition showed the whole 2-D vortex structures clearly. In addition, the spatial distributions of small-scale vortices as well as large-scale vortices were obtained with high accuracy. The difference of vortex structures between the MRF coated flat plate and the smooth flat plate was analysed in detail. With varying upstream flow speed, the characteristics of vortex structure over the MRF coated flate plate was compared with those over the smooth flat plate.

  • PDF

Design Optimization of Plate Heat Exchanger with Staggered Pin Arrays (엇갈린 핀 배열을 갖는 평판 열교환기의 최적 설계)

  • Park, Kyoung-Woo;Choi, Dong-Hoon;Lee, Kwan-Soo;Chang, Kyu-Ho
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1441-1446
    • /
    • 2003
  • The design optimization of the plate heat exchanger with staggered pin arrays for a fixed volume is performed numerically. The flow and thermal fields are assumed to be a streamwise-periodic flow and heat transfer with constant wall temperature and they are solved by using the finite volume method. The optimization is carried out by using the sequential linear programming (SLP) method and the weighting method is used for solving the multi-objective problem. The results show that the optimal design variables for the weighting coefficient of 0.5 are as follows; S=6.497mm, P=5.496mm, $D_1=0.689mm$, and $D_2=2.396mm$. The Pareto optimal solutions are also presented.

  • PDF

Experimental Study on Measuring the Intermittency in the Transitional Boundary Layer (천이경계층에서의 간헐도 측정에 관한 실험적 연구)

  • 임효재;안재용;백성구;정명균
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.1
    • /
    • pp.9-18
    • /
    • 2003
  • An experimental study was performed to investigate the turbulence intermittency measuring methods across the boundary layer in the transition region. A single type hot-wire probe was used to measure instantaneous streamwise velocities in laminar, transitional and turbulent boundary layer To estimate wall shear stresses on the flat plate, near wall mean velocities are applied to the principle of CPM. Distribution of intermittency factor is obtained by dual-slope method and compared to the results of four methods,$\'{u},\;\{U}$, TERA and M-TERA method. In these methods, M-TERA shows a good agreement in the near wall region. However, the result of M-TERA method shows that intermittency factor is underestimated in the outer part and outside of the boundary layer and the dimensional constant of M-TERA method should be changed appropriately depending on measuring point.

Numerical Simulation of Plate Finned-Tubes Condenser (평판휜-관 응축기의 수치 시뮬레이션)

  • Min, M.S.;Choi, S.G.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.193-205
    • /
    • 1994
  • A simulation program of the plate finned-tubes condenser widely used in the air conditioning system was developed. The program took into account the variations of the flow properties and fluid friction factor of refrigerant, and the heat transfer coefficients of refrigerant and air sides. The program was applied to a copper tube condenser which has outside diameter of 10.05mm, inside diameter of 9.35mm, length of 5.20m and three rows arraied staggered. Simulation results were such that refrigerant was super-heated state from the entrance to the 0.14m point, two-phase flow from the 0.14m point to the 4.10m point, sub-cooled state from the 4.10m point to the outlet. The degree of sub-cooled was $6.1^{\circ}C$. The variations of refrigerant quality, temperature, pressure, velocity, specific enthalpy, specific volume and air temperature, tube temperature were showed.

  • PDF

Numerical study on wavemaking phenomena generated by a planning flat plate (활주평판의 조파현상에 관한 수치연구)

  • 곽승현
    • Journal of Ocean Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.81-91
    • /
    • 1996
  • Numerical study is carried out to make clear the wavemaking phenomena for a planning flat plate. Through the mumerical computations, some schematic wave patterns are compared with experimental results, for example, such as the bow divergent waves, triangle waves, stern divergent saves, stern cross waves. The characteristic distance of waves is found to be more inconsistent as the incidence angle increases. The comparison was mode between computations and experiments for incidence angles of 5, 10 and 15 degrees. However, a numerical difficulty is found around and behined the trailing edges for more than 20 degree.

  • PDF

MULTIPLE SOLUTIONS IN NATURAL CONVECTION BETWEEN TWO HORIZONTAL PLATES WITH SMALL MAGNITUDE NON-UNIFORM TEMPERATURE IN THE UPPER PLATE (위 평판이 작은 불균일 온도를 갖는 두 수평 평판 사이의 자연 대류에서의 다중해)

  • Yoo, Joo-Sik
    • Journal of computational fluids engineering
    • /
    • v.21 no.3
    • /
    • pp.64-70
    • /
    • 2016
  • Multiple solutions in natural convection of water with Pr=7 between two horizontal plates with small magnitude non-uniform temperature distribution in the upper plate is numerically investigated. The dimensionless temperature of upper plate is ${\theta}={\epsilon}sinkx$. Two upright cells are formed over one wave length in the conduction-dominated regime of small Rayleigh number. However, multicellular convection occurs above a critical Rayleigh number for small wave number. When k = 1.5, dual solutions are found and a transition of $6{\rightarrow}4$ eddy flow occurs with decrease of Rayleigh number. When k = 0.75, two, three, four and five multiple solutions are observed. Transitions of $14{\rightarrow}12$, $12{\rightarrow}10$, $10{\rightarrow}8$ and $6{\rightarrow}8$ eddy flow occur with decrease of Rayleigh number.

Experimental Investigation on the Flow Characteristics of ER Fluids III (3nd Report, Flow-Pressure Drop Characteristics clearance between Two Parallel Plate) (ER유체의 유동특성에 관한 실험적 연구 III (평행평판 간극내의 유량-압려강하 특성))

  • 김도태
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.399-404
    • /
    • 1999
  • Electro-rheological(ER) fluids are suspensions which show an abrupt increase in rheological properties under electric fields. The rheological response is very rapid and reversible when the electric field is imposed and/or removed. Therefore, there are many practical applications using the ER fluids. The purpose of the present study is to examine the flow characteristics of electro-rheological fluids. The field-dependent yield stress are obtained from experimental investigation on the Bingham property of the ER fluid. Then the steady relationshup between pressure drop and flow rate of the ERF was two fixed parallel-plates was measured under application of an electric fields. The electrical and rheological properties of zeolite based electro-rheological fluids were reported.

  • PDF

A Study on Performance Characteristics Planar angle diffuser with PIV (PIV를 이용한 평판형 디퓨저의 유동특성에 관한 실험적 연구)

  • Oh, Jeong Hun;Cho, Dae-Hwan;Seok, Baek Un
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2012.06a
    • /
    • pp.261-262
    • /
    • 2012
  • In planar angle diffuser, the increasement of cross-sectional area so rapidly cause possibly separate from the diffuser wall and forming areas of backflow. The flow characteristics of planar angle diffuser was investigated for three kind of inclined angle. Judging from the results, wide planar diffuser can be used as an effective means of improvement for diffuser performance and inclined angle of diffuser was through to be the best among three cases.

  • PDF

Numerical Study for Air-Side Flow Characteristics of Fin-Tube Heat Exchangers with Oval-Tube (타원관형 핀-관 열교환기의 공기측 열유동특성에 대한 수치해석)

  • 김승택;최윤호;김형택
    • Journal of Energy Engineering
    • /
    • v.10 no.2
    • /
    • pp.166-175
    • /
    • 2001
  • 핀-관 열교환기의 효율을 증대시키기 위하여는 열저항을 결정하는데 있어서 중요한 역할을 하는 공기측 열전달 특성의 향상이 필요하다. 본 연구에서는 슬릿핀과 같은 핀 형상의 개선으로 인한 높은 압력손실을 감소시키기 위하여 타원관형 열교환기를 고려하였으며 이를 자체 개발한 3차원 비압축성 Navier-Stokes 코드를 이용하여 공기측 성능을 해석하였다. 이 코드는 시간항에 스칼라 내재적 근사분해법(scalar implicit approximate factorization)절차, 공간항에 유한체적법과 2차의 풍상차분법을 사용한다. 핀 형상이 평판핀인 타원관에 대하여 세장비가 0.3, 0.5, 0.75인 경우와 핀 형상이 슬릿핀이고 세장비가 0.5인 타원관에 대하여 공기측 유동을 해석하였으며 이를 원관의 성능과 비교하였다. 평판핀의 경우, 압력강하량은 원관과 비교하여 세장비가 작아질수록 감소하는 것을 볼 수 있었으며, 열전달 계수는 고려한 유입속도 범위에서 원관을 기준으로 약 5%이하의 변화로 거의 동일하게 유지되는 것을 볼 수 있었다. 슬릿핀의 경우 역시 문제되는 높은 압력강하량은 타원관을 도입함으로써 효과적으로 낮출 수 있음을 볼 수 있었다.