• Title/Summary/Keyword: 평면성 검사

Search Result 80, Processing Time 0.032 seconds

Fundamental Study of Relative Measurement for Accurate Measurement of Stent Size in Computed Tomography Angiography (컴퓨터단층 혈관조영술에서 스텐트 사이즈의 정확한 측정을 위한 상대적 측정법의 기초연구)

  • Lee, Seung-Young;Hong, Joo-Wan;Kang, Su-Mi;Kim, Su-Bin;Joon, Sang-Hoon;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.713-720
    • /
    • 2019
  • The purpose of this study was to propose a new measurement method for accurate measurement of vessel diameter in computed tomography angiography(CTA). CTA test was performed after non-ionic iodine contrast agent was flowed at a constant rate to self-maded perfusion phantom. After obtaining raw data, images were reconstructed with multi-planar reconstruction(MPR) and maximal intensity projection(MIP). Diameters of vascular models were measured for each technique. Relative and conventional measurements were then compared. The mean diameter of the vascular model was closer to the actual measurement when relative measurement was used compared to that when conventional measurement was used both in MPR and MIP. Relative measurements of MPR and MIP were closer to actual measurement than those of conventional measurement (34% VS, 24%, p<0.05). The relative measurement method proposed in this study was closer to the actual measurement than the conventional measurement method. However, both test methods were still larger than actual results. Therefore, further study of relative measurement method is needed using this study as basic data.

Flaw Detection of Ultrasonic NDT in Heat Treated Environment Using WLMS Adaptive Filter (열처리 환경에서 웨이브렛 적응 필터를 이용한 초음파 비파괴 검사의 결함 검출)

  • 임내묵;전창익;김성환
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.7
    • /
    • pp.45-55
    • /
    • 1999
  • In this paper, we used the WLMS(Wavelet domain Least Mean Square) adaptive filter based on the wavelet transform to cancel grain noise. Usually, grain noise occurs in changes of the crystalline structure of metals in high temperature environment. It makes the detection of flaw difficult. The WLMS adaptive filtering algorithm establishes the faster convergence rate by orthogonalizaing the input vector of adaptive filter as compared with that of LMS adaptive filtering algorithm in time domain. We implemented the WLMS adaptive filter by using the delayed version of the primary input vector as the reference input vector and then implemented the CA-CFAR(Cell Averaging- Constant False Alarm Rate) threshold estimator. CA-CFAR threshold estimator enables to detect the flaw and back echo signals automatically. Here, we used the output signals of adaptive filter as its input signal. To Cow the statistical characteristic of ultrasonic signals corrupted by grain noise, we performed run test. The results showed that ultrasonic signals are nonstationary signal, that is, signals whose statistical properties vary with time. The performance of each filter is appreciated by the signal-to-noise ratio. After LMS adaptive filtering in time domain, SNR improves to about 2-3㏈ but after WLMS adaptive filtering in wavelet domain, SNR improves to about 4-6㏈.

  • PDF

Penetration Depth Computation for Rigid Models using Explicit and Implicit Minkowski Sums (명시적 그리고 암시적 민코우스키 합을 이용한 강체 침투깊이 계산 알고리즘)

  • Lee, Youngeun;Kim, Young J.
    • Journal of the Korea Computer Graphics Society
    • /
    • v.23 no.1
    • /
    • pp.39-48
    • /
    • 2017
  • We present penetration depth (PD) computation algorithms using explicit Minkowski sum construction ($PD_e$) and implicit Minkowski sum construction ($PD_i$). Minkowski sum construction is the most time consuming part in fast PD computation. In order to address this issue, we find a candidate solution using a centroid difference and motion coherence. Then, $PD_e$ constructs or updates partial Minkowski sum around the candidate solution. In contrast, $PD_i$ constructs only a tangent plane to the Minkowski sums iteratively. In practice, our algorithms can compute PD for complicated models consisting of thousands of triangles in a few milli-seconds. We also discuss the benefits of using different construction of Minkowski sums in the context of PD.

A Study on the Relationship between the Apartment Interior Image Preference ana Personality Types. (아파트 실내 이미지 선호와 성격유형과의 상관성에 관한 연구)

  • 이종희
    • Archives of design research
    • /
    • v.16 no.1
    • /
    • pp.229-240
    • /
    • 2003
  • This study, planed as an idea to promote the degree of the qualitative satisfaction on the residential space and to correspond effectively with the several and characteristic needs, is a try to overcome the limitation which is not to construct with the several plane-plans but the common designs on an apartment, unlike to an individual residence, should be designed for the unidentified persons. For this purpose, 1 set 360 mother group to investigate how to change their degree of the interior-image preference through their Personality Types by the apartment interior image pattern, verified by the pre-study on the real-resident's degree of preference corresponding with MBTI(Myers-Briggs Type Indicator), a Personality Types investigation. This result, leading us to be able to predict the resident's needs of the interior image aspects following the preference of the several products and to be able to supply the products, is being thought to contribute to promote the degree of satisfaction of the resident.

  • PDF

Digital duplication of provisional prosthesis to fabricate definitive prosthesis for full mouth rehabilitation using double scan technique (잠정수복물의 최종수복물로의 디지털 복제를 통한 완전구강 회복 증례: Double scan technique)

  • Hong, Young-Tack;Koak, Jai-Young;Kim, Seong-Kyun;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.63-70
    • /
    • 2021
  • Using computer-aided design and manufacturing technique improve quality of treatment in many aspect. This case reports the complete mouth rehabilitation of a patient with amelogenesis imperfecta utilizing digital technology. Clinical examination revealed loss of mastication due to insufficient occlusal stop, missing teeth, interdental spacing due to microdontia, insufficient overbite, and etc. Full veneer crowns for teeth were selected, followed by a fixed partial denture and implant placement was done using CAD-CAM guide template with bone graft for partially edentulous space. Definitive restorations were duplicated by double scanning provisional restorations and successfully delivered to the patient. These full mouth rehabilitation procedures resulted in satisfactory outcomes for the patient functionally and aesthetically.

The Usefulness of Bone Scintigraphy in SAPHO Syndrome (SAPHO 증후군에서 골신티그라피의 유용성)

  • Lim, Seok-Tae;Sohn, Myung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.4
    • /
    • pp.255-260
    • /
    • 2002
  • Purpose: SAPHO syndrome is well known to various disease entities including synovitis, acne, pustulosis, hyperostosis and polyarthritis. The purpose of this study is to evaluate sicntigraphic findings and to compare with radiologic findings in SAPHO syndrome. Materials and Methods: Five patients (M:F=5.0, Age $22.8{\pm}4.78$ yrs) with SAPHO syndrome were enrolled in our study. All patients underwent whole-body bone scintigraphy with intravenous administration of 740 MBq of Tc-99m MDP. Among them, two patients were additionally perfomed SPECT of the spine to evaluate the location and extort of spinal lesion. Results: All patients were demonstrated abnormal increased uptakes in sternoclavicular joint (SC), sacroiliac joint (SI), and small joints of both hands. Among them, three patients were bilateral involvement (3/5) and two were unilateral (2/5) in SC. involvement of SI showed bilateral in four patients (4/5) and unilateral in one (1/5). SPECT images demonstrate that the lesion sites of the lumbar spine are more likely facet joints than vertebral bodies or pedicles. Conclusion: As SAPHO syndrome is the disease entity involved polyarticular joints with various dermatologic manifestations, the bone scintigraphy may be a very useful method to evaluate the location and extent of joint involvement, and to avoid inadequate surgical management or ineffective antibiotic treatment.

A Study on Application of SPOT5 Image for Renewal of Digital Map (수치지도 갱신을 위한 SPOT5 영상의 활용에 관한 연구)

  • Kang Joon Mook;Yun Hee Cheon;Park Joon Kyu;Um Dae Yong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.23 no.1
    • /
    • pp.89-96
    • /
    • 2005
  • With acquisition of satellite image being facilitated due to recent advancement in Electro optical and astronautic technologies, focus on establishment of Geoinformation and analysis using satellite images have increased. This research have conducted digital plotting and digitizing operation, utilizing stereo images and grey level images provided by SPOT5 satellite and evaluated the accuracy through comparison and analysis with digital map results. Digital plotting results acquired using stereo images have been compared and analyzed on the basis of scale 1:25,000 digital map results published by National Geographic Information Institute. Accuracy of 20 check points have showed RMSE results 5.369 m at X (Easting) and 4.718 m, digitizing using grey level images showed RMSE results 7.616 m in X (Easting) and Y (Northing) 6.532 m. This is within the allowance of accuracy standards for scale 1:25,000 maps, and although digitizing operation was confirmed to have lower accuracy than that of digital plotting, using the former is considered to be more effective in terms of economical efficiency.

Thallium-201 SPECT in the Evaluation of Postoperative Tumor Recurrence on the Chest Wall in Lung Cancer (폐암 수술 후 흉벽의 종양 재발 검출에 있어 Tl-201 폐 SPECT의 유용성)

  • Ryu, Young-Hoon;Kim, Hyung-Jung;Ahn, Chul-Min;Kim, Se-Kyu;Paik, Hyo-Chae;Lee, Doo-Yun;Chung, Kyung-Young;Yune, Min-Jin;Park, Sang-Jung;Moon, Sung-Wook;Kim, Sang-Jin;Lee, Jong-Doo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.5
    • /
    • pp.542-549
    • /
    • 2002
  • Purpose : The purpose of our study was to assess the usefulness of the Tl-201 SPECT for the detection of the postoperative tumor recurrence on chest wall. Methods: 28 patients including 14 with suspected recurrence of tumor in the chest wall on postoperative chest cr scan, 10 with postoperative pleural effusion which proved benign on radiologic, cytologic and laboratory findings, and 4 with chronic tuberculous empyema as control group were included. All patients underwent SPECT 30 minutes and 4 hours after intravenous injection of 111MBq of Tl-201. Tumor uptake was visually graded by two interpreters and scored as follows : no uptake:0, similar to contralateral lung: 1, higher than contralateral lung but less than heart:2 and similar to heart:3. Results : Markedly increased (grade 3 or 2) Tl-201 uptake was noted in patients with suspected recurrence of tumor in the chest wall (13/14) whereas no (8/10) or minimal (2/10) uptake along the collapsed lung in patients with postoperative benign pleural effusion. In two patients, Tl-201 SPECT revealed additional recurrent tumor mass lesions that were barely perceptible on chest cr scan. Patients with chronic tuberculous empyema showed relatively smoothly marginated increased uptake along the chest wall 4/4), but lesser in degree (grade 1 or 2), when compared to recurrent tumor uptake. Conclusion : Tl-201 lung SPECT seems to be useful to detect postoperative tumor recurrence on chest wall and to differentiate malignant from benign pleural effusion and may provide additional information to the morphologic data obtained by CT.

Detection for Residual Thyroid Tissue and Metastatic Lesion after Total Thyroidectomy in Patients with Differentiated Thyroid Cancer: Comparison between Tc-99m Pertechnetate Sean and High Dose I-131 Therapy Sean (분화 갑상선암 환자의 수술후 잔여갑상선조직 및 전이병소의 진단: Tc-99m Pertechnetate 스캔과 고용량 옥소 치료 후 I-131 스캔의 비교)

  • Lee, Joo-Ryung;Ahn, Byeong-Cheol;Jeong, Shin-Young;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.120-127
    • /
    • 2003
  • Purpose: To evaluate diagnostic sensitivity of nuclear imaging in the detection of residual thyroid tissue and metastatic lesion, we have compared neck scintigrams with Tc-99m pertechnetate (Tc-99m scan) and high dose I-131 iodide (I-131 scan) in patients with differentiated thyroid cancer. Subjects and Methods: One hundred thirty-five thyroidectomized patients for differentiated thyroid cancer were enrolled in this study. Twenty-three had a previous history of radioiodine therapy. Planar and pin-hole images of anterior neck with Tc-99m were acquired at 20 minutes after injection, followed by I-131 scan three days after high-dose radioiodine therapy within 7 days interval. Patients were asked to discontinue thyroid hormone replacement more than 4 weeks. Results: All subjects were in hypothyroid state. Seventy out of 135 patients (51.9%) showed concordant findings between Tc-99m and I-131 scans. I-131 scan showed higher number of uptake foci in all of 65 patients showing discordant finding. Tc-99m scan showed no thyroid bed uptake in 34 patients, whereas 23 of them (67.6%) showed bed uptake in I-131 scan. Tc-99m scan did not show any uptake in thyroid bed in 11 of 112 patients without previous history of radioiodine therapy, but 9 of them showed bed uptake in I-131 scan. Tc-99m scan showed no bed uptake in all of the 23 patients with previous history of radioiodine therapy, in contrast 14 of them (60.9%) showed bed uptake in I-131 scan. Conclusion: These results suggest that Tc-99m scan has poor detectability for residual thyroid tissue or metastatic lesion in thyroidectomized differentiated thyroid cancer patients, compared to high dose I-131 therapy scan. Tc-99m scan could not detect any remnant tissue or metastatic lesion in patients with previous history of radioiodine treatment, especially.

Biological Activities of Calcium Polyphosphate (Calcium polyphosphate의 생물학적 활성도에 관한 연구)

  • Seol, Yang-Jo;Lee, Jae-Il;Lee, Yong-Moo;Lim, Yoon-Tak;Kim, Seok-Young;Ku, Young;Rhyu, In-Chul;Hahm, Byung-Do;Han, Soo-Boo;Choi, Sang-Mook;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.2
    • /
    • pp.213-231
    • /
    • 2000
  • 이 연구의 목적은 다공성의 CPP 내부에 쥐의 장골의 골수에서 유래된 세포를 접종하고 3차 원적으로 배양하여 CPP가 골 형성을 위한 조직공학의 지지체로 적용가능한가를 연구하는 것과 Calcium PolyPhosphate(CPP)의 돌연변이 유발성을 검사하는 것이다. 무수 ($Ca(H_2PO_4)$)를 condensation하여 무결정의 ($Ca(PO_3)$)를 얻고 이를 용융하고 냉각시킨 후 분쇄하여 Calcium polyphosphate(CPP) powder를 얻었다. 다공성의 CPP는 5% $SiO_2$를 첨가하여 sponge 형태로 $450-550{\mu}m$ 소공의 크기를 가지는 것과(CPP-45ppi) $200-300{\mu}m$의 소공의 크기를 가지는 것(CCP-60ppi) 2가지로 제작하였다. 각각의 CPP matrices는 $5mm{\times}5mm{\times}1mm$의 블록 형태로 만들었다. 체중 100g 내외의 백서에서 장골(femur, tibia)을 채취하여 백서의 장골 골수 세포를 분리하여 배양한 후 24well에 CPP block을 넣고 CPP block 당 $10^5$개의 배양한 세포를 접종하였다. 배양 1, 7, 14, 및 21 일째에 각 well에서 trypsin EDTA를 이용하여 2회 반복하여 cell을 분리하였고, 원심분리한 후 hemacytometer로 측정하였다. 또, 45ppi와 60ppi, 그 리 고 Tissue Culture Polystyrene(control group)에 접종, 배양된 세포들의 염기성 인산분해효소활성도를 배양 7, 14, 및 21 일째에 각각 측정하였다. 각 기간별로 배양된 세포-CPP 혼합체내에서 세포의 부착 및 증식과 형성된 조직의 3차원적 형태를 관찰하기 위하여 주사전자현미경하에서의 관찰하였다. CPP의 돌연변이 유발성 검사 (mutagenicity test)를 위해 hypoxanthine-guanine phosphoribosyl transferase(HPRT) assay를 하였다. NIH3T3 cell line과 CHO-K1 cell line으로 각각 $1000{\mu}g/m{\ell}$, $100{\mu}g/m{\ell}$, $10{\mu}g/m{\ell}$ 그리고 $1{\mu}g/m{\ell}$의 CPP 농도에서 측정하였다. 통계적 분석을 위해서 모든 측정은 각군당 4개체 이상 시험하였고, 각 측정값은 평균값${\pm}$표준편차로 나타내었다. 각 군간의 통계적 유의성 검정을 위해서 Analysis of variance(ANOVA)를 이용하였고 Tukey의 방법으로 사후분석을 실시하였다. 제작된 CPP matrices 소공들이 서로간에 연결이 잘 되어있는 형태였다. 두 가지로 제조된 CPP(45ppi와 60ppi) 모두에서 세포의 부착이 잘 일어났고, 부착된 세포의 분열도 잘 일어났다. 2 가지의 CPP 모두에서 7, 14, 21일째의 세포 수는 1일째에 비해 유의성 있게 증가하였다(P<0.01). 3차원적 구조인 Calcium PolyPhosphate에서 배양한 세포는 24well dish(tissue culture polystyrene)에서 평면적으로 배양한 대조군의 세포에서 보다 염기성 인산분해효소 (Alkaline Phosphatase)를 유의성 있게 높게 나타냈다. 주사전자현미경에서 세포-CPP 혼합체를 관찰한 결과, CPP block에 세포들이 잘부착되어 있었고, 시간이 지남에 따라 세포가 여러 층을 형성하면서 뭉치는 현상을 보였다. 또, HPRT assay 결과 , Calcium PolyPhosphate는 돌연변이 유발성을 보이지 않았다. 이상의 결과로 볼 때 CPP에는 세포부착이 잘 일어나고, 지지체 상에서 세포의 분열도 활발하게 일어나므로 골조직을 위한 조직공학의 우수한 지지체가 될 수 있을 것으로 사료된다.

  • PDF