• Title/Summary/Keyword: 평균 프로파일 깊이

Search Result 8, Processing Time 0.023 seconds

Face Recognition Based on Weighted Hausdorff Distance for Profile Image (가중치 하우스도르프 거리를 이용한 프로파일 얼굴인식)

  • 이영학
    • Journal of Korea Multimedia Society
    • /
    • v.7 no.4
    • /
    • pp.474-483
    • /
    • 2004
  • In this paper, we present a new Practical implementation of a person verification system using the profile of 3-dimensional(3D) face images based on weighted Hausdorff distance(WHD) used depth information. The approach works on finding the nose tip have protrusion shape on the face using iterative selection method to use a fiducial feint and extract the profile image from vertical 3D data for the nose tip. Hausdorff distance(HD) is one of usually used measures for object matching. This works analyze the conventional HD and WHD, which the weighted factor is depth information. The Ll measure for comparing two feature vectors were used, because it is simple and robust. In the experimental results, the WHD method achieves recognition rate of 94.3% when the ranked threshold is 5.

  • PDF

Analysis of Texture Depth of Asphalt Pavement Based on Profile Analysis (프로파일 분석을 통한 아스팔트 콘크리트 포장 텍스쳐 크기 분석)

  • Park, Dae-Wook
    • International Journal of Highway Engineering
    • /
    • v.14 no.3
    • /
    • pp.9-14
    • /
    • 2012
  • In this study, the profiles of asphalt pavements were measured using a lightweight profiler and depths of macrotexture were analyzed based on the measured profiles. Profiles on dense graded asphalt pavement, prorous asphalt pavement, stone mastic asphalt (SMA) pavement, and base layer measured, and depth of macrotexture were calculated and analyzed. Profiles on the pavement that happened as asphalt mixture segregation were measured and depths of macrotexture were analyzed. The results showed that the depths of macrotexture of asphalt pavement were effectively calculated using the measured profiles, and the depths of macrotexture for different asphalt pavements were analyzed. The pavement areas which have asphalt mixture segregation were detected based on analysis of macrotexture depths.

Depth Map coding pre-processing using Depth-based Mixed Gaussian Histogram and Mean Shift Filter (깊이정보 기반의 혼합 가우시안 분포 히스토그램과 Mean Shift Filter를 이용한 깊이정보 맵 부호화 전처리)

  • Park, Sung-Hee;Yoo, Ji-Sang
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.175-177
    • /
    • 2010
  • 본 논문에서는 MPEG 의 3차원 비디오 시스템의 표준 깊이정보 맵에 대한 효율적인 부호화를 위하여 전처리 방법을 제안한다. 현재 3차원 비디오 부호화(3DVC)에 대한 표준화가 진행 중에 있지만 아직 깊이정보 맵의 부호화 방법에 대한 표준이 확정되지 않은 상태이다. 제안하는 기법에서는 우선, 입력된 깊이정보 맵에 대하여 원래의 히스토그램 분포를 가우시안 혼합모델(GMM)기반의 EM 군집화 기법에 의한 방법으로 분리 후, 분리된 히스토그램을 기반으로 깊이정보 맵을 여러 개의 영상으로 분리한다. 그 후 분리된 각각의 영상을 배경과 객체에 따라 다른 조건의 mean shift filter로 필터링한다. 결과적으로 영상내의 각 영역 경계는 최대한 살리면서 영역내의 화소 값에 대해서는 평균 연산을 취하여 부호화시 효율을 극대화 하고자 하였다. 실험조건은 $1024{\times}768$ 영상에 대해서 50 프레임으로 H.264/AVC base 프로파일로 부호화를 진행하였다. 최종 실험결과 bit rate는 대략 23% ~ 26% 정도 감소하고 부호화 시간도 다소 줄어드는 것을 확인 할 수 있었다.

  • PDF

Improved CABAC Design for HEVC Lossless Intra-frame Coding (HEVC 무손실 화면내 부호화를 위한 향상된 CABAC)

  • Choi, Jung-Ah;Ho, Yo-Sung
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2013.06a
    • /
    • pp.278-279
    • /
    • 2013
  • 최근에 완료된 HEVC(High Efficiency Video Coding) 비디오 압축 표준은 H.264/AVC에 비해 2배 이상 향상된 압축 효율을 제공한다. 현재 진행 중인 HEVC 확장 (extension) 작업에서는 손실 및 무손실 부호화에서 4:2:2 및 4:4:4 색차 포맷과 최대 12비트 깊이를 지원하는 고급 프로파일을 개발하고 있다. 현재까지 개발된 HEVC의 CABAC(Context-based Adaptive Binary Arithmetic Coding)은 손실 부호화 환경에 적합하게 설계되었기 때문에 무손실 부호화 환경에서 최적의 부호화 성능을 제공하지 못한다. 본 논문에서는 4:4:4 색차 포맷 영상의 무손실 화면내 부호화 환경에서 잔여 신호의 통계적 특성을 고려한 향상된 CABAC 잔여 데이터 부호화 방법을 제안한다. 실험 결과를 통해, 본 논문에서 제안하는 향상된 CABAC 방법이 무손실 화면내 부호화에서 기존의 CABAC 방법에 비해 평균 약 2.41% 의 비트 수를 감소시키는 것을 확인했다.

  • PDF

Compare the Clinical Tissue Dose Distributions to the Derived from the Energy Spectrum of 15 MV X Rays Linear Accelerator by Using the Transmitted Dose of Lead Filter (연(鉛)필터의 투과선량을 이용한 15 MV X선의 에너지스펙트럼 결정과 조직선량 비교)

  • Choi, Tae-Jin;Kim, Jin-Hee;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.80-88
    • /
    • 2008
  • Recent radiotherapy dose planning system (RTPS) generally adapted the kernel beam using the convolution method for computation of tissue dose. To get a depth and profile dose in a given depth concerened a given photon beam, the energy spectrum was reconstructed from the attenuation dose of transmission of filter through iterative numerical analysis. The experiments were performed with 15 MV X rays (Oncor, Siemens) and ionization chamber (0.125 cc, PTW) for measurements of filter transmitted dose. The energy spectrum of 15MV X-rays was determined from attenuated dose of lead filter transmission from 0.51 cm to 8.04 cm with energy interval 0.25 MeV. In the results, the peak flux revealed at 3.75 MeV and mean energy of 15 MV X rays was 4.639 MeV in this experiments. The results of transmitted dose of lead filter showed within 0.6% in average but maximum 2.5% discrepancy in a 5 cm thickness of lead filter. Since the tissue dose is highly depend on the its energy, the lateral dose are delivered from the lateral spread of energy fluence through flattening filter shape as tangent 0.075 and 0.125 which showed 4.211 MeV and 3.906 MeV. In this experiments, analyzed the energy spectrum has applied to obtain the percent depth dose of RTPS (XiO, Version 4.3.1, CMS). The generated percent depth dose from $6{\times}6cm^2$ of field to $30{\times}30cm^2$ showed very close to that of experimental measurement within 1 % discrepancy in average. The computed dose profile were within 1% discrepancy to measurement in field size $10{\times}10cm$, however, the large field sizes were obtained within 2% uncertainty. The resulting algorithm produced x-ray spectrum that match both quality and quantity with small discrepancy in this experiments.

  • PDF

Calculation of Energy Spectra for 6 MeV Electron Beam of LINAC Using MCNPX (MCNPX를 이용한 선형가속기의 6 MeV 전자선에 대한 에너지분포 계산)

  • Lee, Jeong-Ok;Jeong, Dong-Hyeok
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.224-231
    • /
    • 2006
  • The electron energy spectra for 6 MeV electron beam were calculated using a MCNPX code. The head of the linear accelerator (ML6M; Mitsubishi, Japan) was modelled for this study. The energy spectrum of the initial electron beam was assumed to be Gaussian and the mean energy was determined by evaluating the measured and calculated values of $R_{50}$ and dose profiles in air. The energy distributions for electrons and photons at the interested points in the head of the linear accelerator were calculated by appling the Initial beam parameters. The effect of contaminant photons on depth dose curves were estimated by the photon energy spectra at the end of the applicator.

  • PDF

Evaluation of Abrasive Wear Face Using SAW (표면탄성파를 이용한 마모 표면부의 평가)

  • Kwon, Sung-D.;Yoon, Seok-S.;Song, Sung-J.;Lee, Young-Z.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.2
    • /
    • pp.193-197
    • /
    • 2002
  • The frequency dependency of the Rayleigh surface wave was investigated indirectly by measuring the angular dependency of the backward radiation of the incident ultrasonic wave in the abrasion specimens, which was explained in view of the residual stress distribution. The peak intensity of the backward radiation profile decreased and the right half width of the profile increased with an increase of the variational rate of residual stress for the scuffing specimen. The peak intensity was also affected by the surface wave scattering during the propagation around the micro-damages. The peak angle might depend on not only the amount of residual stress but also the micro-structure. The result observed in this study demonstrates the high potential of the backward radiated ultrasound as a tool for the nondestructive evaluation of the subsurface gradients of materials.

Evaluation of a Conjugate View Method for Determination of Kidney Uptake (신장 방사선 섭취량 결정을 위한 Conjugate View 방법에 대한 평가)

  • Bong, Jung-Kyun;Yun, Mi-Jin;Lee, Jong-Doo;Kim, Hee-Joung;Son, Hye-Kyung;Kwon, Yun-Youug;Park, Hae-Jeong;Kim, Yu-Seun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.191-199
    • /
    • 2005
  • Purpose: In order to obtain better quantitation of kidney uptake, this study is to evaluate a conjugate view method (CVM) using a geometric mean attenuation correction for kidney uptake and to compare it to Gate's method. Materials & Methods: We used a Monte Carlo code, SIMIND and a Zubal phantom, to simulate kidney uptake. SIMIND was both simulated with or without scatter for the Zubal phantom. Also, a real phantom test was carried out using a dual-head gamma camera. The activity of 0.5 mCi was infused into two small cylinder phantoms of 5 cm diameter, and then, they were inserted into a cylinder phantom of 20 cm diameter. The results by the CVM method were compared with ideal data without both of attenuation and scatter and with Gate's method. The CVM was performed with or without scatter correction. The Gate's method was performed without scatter correction and it was evaluated with regards to $0.12cm^{-1}\;and\;0.15cm^{-1}$ attenuation coefficients. Data were analyzed with comparisons of mean counts in the legions of interest (ROI), profiles drawn over kidney images and linear regression. Correlation coefficients were calculated with ideal data, as well. Results: In the case of the computer simulation, mean counts measured from ideal data, the CVM and the Gate's method were (right $998{\pm}209$, left: $896{\pm}249$), (right: $911{\pm}207$, left: $815{\pm}265$), and (right: $1065{\pm}267$, left: $1546{\pm}267$), respectively. The ideal data showed good correlation with the CVM and the correlation coefficients of the CVM, Gate's method were (right: 0.91, left: 0.93) and (right: 0.85, left: 0.90), respectively. Conclusion: The conjugate view method using geometric mean attenuation correction resulted in better accuracy than the Gate's method. In conclusion, the conjugate view method independent of renal depths may provide more accurate kidney uptake.