• Title/Summary/Keyword: 평균 경로 길이

Search Result 190, Processing Time 0.034 seconds

A Study on Predictive Traffic Information Using Cloud Route Search (클라우드 경로탐색을 이용한 미래 교통정보 예측 방법)

  • Jun Hyun, Kim;Kee Wook, Kwon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.33 no.4
    • /
    • pp.287-296
    • /
    • 2015
  • Recent navigation systems provide quick guide services, based on processing real-time traffic information and past traffic information by applying predictable pattern for traffic information. However, the current pattern for traffic information predicts traffic information by processing past information that it presents an inaccuracy problem in particular circumstances(accidents and weather). So, this study presented a more precise predictive traffic information system than historical traffic data first by analyzing route search data which the drivers ask in real time for the quickest way then by grasping traffic congestion levels of the route in which future drivers are supposed to locate. First results of this study, the congested route from Yang Jae to Mapo, the analysis result shows that the accuracy of the weighted value of speed of existing commonly congested road registered an error rate of 3km/h to 18km/h, however, after applying the real predictive traffic information of this study the error rate registered only 1km/h to 5km/h. Second, in terms of quality of route as compared to the existing route which allowed for an earlier arrival to the destination up to a maximum of 9 minutes and an average of up to 3 minutes that the reliability of predictable results has been secured. Third, new method allows for the prediction of congested levels and deduces results of route searches that avoid possibly congested routes and to reflect accurate real-time data in comparison with existing route searches. Therefore, this study enabled not only the predictable gathering of information regarding traffic density through route searches, but it also made real-time quick route searches based on this mechanism that convinced that this new method will contribute to diffusing future traffic flow.

Feasibility Study of Laparoscopic Gastrostomy Tube Placement in Beagle Dogs (비글견에서 복강경을 이용한 위관삽입술의 유용성 평가 연구)

  • Lee, Jae-Woong;Park, Ji Young;Lee, Hae-Beom;Jeong, Seong Mok
    • Journal of Veterinary Clinics
    • /
    • v.32 no.1
    • /
    • pp.28-35
    • /
    • 2015
  • Aim of this study is demonstrate the feasibility of Laparoscopic gastrostomy (LG) tube placement in dogs by comparing with percutaneous endoscopic gastrostomy (PEG) tube placement, based on operative time, complications and gastro-peritoneal adhesion evaluation. Eight intact male beagle dogs were used in this study. Tri-Funnel Replacement Gastrostomy tube (Bard Inc., USA) of 20 Fr was used for LG technique and PEG kit (Ponsky "Pull" PEG Kit$^{(R)}$, Bard Inc., USA) with soft silicone retention dome consisting of a 20 Fr gastrostomy tube was used. Feeding via gastrostomy tube was performed in two weeks, maintenance energy requirement (MER) divided into 3 separate feeding. LG and PEG were evaluated at intraoperative, postoperative and postmortem period. Mean operative time for the PEG group was significantly shorter when compared with the LG group (p < 0.05). Successful maintenance of gastrostomy tube was confirmed in all dogs. Gastric and peritoneal wall adhesions were formed successfully in each group. The mean adhesion length (AL) and width (AW) were significantly larger in LG group compared with in PEG group (p < 0.05). The mean adhesion distance (AD) was not significantly different between two groups (p = 0.182). Consequently, LG is an effective minimally invasive, safe and easy to perform technique for providing enteral nutritional support in dogs.

Measurement and Analysis of Propagation Characteristics in Curved Subway Tunnel Environments (곡선형 지하철 터널환경에서 전파 특성의 측정과 분석)

  • 정회동;박노준;강영진;송문규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.8A
    • /
    • pp.950-961
    • /
    • 2004
  • In this paper, we measured and analyzed propagation characteristics in a subway tunnel that is recently increasingly becoming one of the radio communication environments. The measurements are carried out in a subway tunnel with frequency bands of 2.45㎓ and 5.8㎓. The length of tunnel we used for this study is 175m of LOS (Line-of-sight) and 270m of NLOS (Non Line-of-Sight). The subway tunnel is curved and its cross section is horseshoe type. The measurement systems we employ in this study are a narrow-band system and a wide-band system. The narrow-band system is used to get path loss measurement and the wide-band system is used to figure out delay profile measurement. In particular, the wide-band system consists of 1023 length PN sequence generator using a chip rate of 80MHz based on a sliding correlation technique. The omni-directional antennas and directional antennas are used to analyze propagation characteristics for beam type of antenna. The path loss displays only pure path loss of a tunnel environment. The delay profile indicates the mean excess delay and RMS (root mean square) delay spread.

A Study of Pedestrian Navigation Service System for Visual Disabilities (시각장애인용 길안내 서비스 시스템에 대한 연구)

  • Jang, Young Gun;Cha, J.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.4
    • /
    • pp.315-321
    • /
    • 2017
  • This paper is a study on the design and realization of Pedestrian navigation service system for the visually impaired. As it is an user interface considering visually impaired, voice recognition functioned smartphone was used as the input tool and the Osteoacusis headset, which can vocally guide directions while recognizing the surrounding environment sound, was used as the output tool. Unlike the pre-existing pedestrian navigation smartphone apps, the developed system guides walking direction by the scale of the left and right stereo sound of the headset wearing, and the voice guidance about the forked or curved path is given several meters before according to the speed of the user, and the user is immediately warned of walking opposite direction or proceeding off the path. The system can acquire stable and reliable directional information using the motion tracker with the dynamic heading accuracy of 1.5 degrees. In order to overcome GPS position error, we proposed a robust trajectory planning algorithm for position error. Experimental results for the developed system show that the average directional angle error is 6.82 degrees (standard deviation: 5.98) in the experimental path, which can be stated that it stably navigated the user relatively.

Optimization of Temporal Skip Factor for Scene Change Detection in Video Sequence (동영상내에서의 장면 전환 검출 간격의 최적화)

  • 하명환;나윤정;이상길
    • Journal of Broadcast Engineering
    • /
    • v.3 no.2
    • /
    • pp.146-154
    • /
    • 1998
  • 시간적 표본화를 채택한 다중경로방법에 의한 장면전환 검출방법은 전 동영상에 대해 매 프레임마다 순차적으로 검색하는 방법에 비해서 빠르며, 동일한 정확성을 갖고 있다. 그러나, 검출 시간을 최소화하기 위한 적절한 검출 간격을 선택하는 어떠한 기준이나 방법도 제시되지 않았으며 검출 간격을 경험에 의해 선택할 수밖에 없다. 이 논문에서는 장면 전환 검출 시간, 검출 간격과 실제 장면 전환 간격으로부터 검출 시간을 최소화하는 최적 검출 간격을 얻을 수 있음을 보였다. 평균 장면 전환 간격이 알려져 있지 않은 동영상에 대해서 최적 검출 간격을 추정할 수 있는 알고리듬을 제안하였다.

  • PDF

Second-look Arthroscopic Findings after ACL Reconstruction - The Changes around Graft - (전방 십자 인대 재건술후 2차 관절경 검사 소견 - 이식건 주위의 변화 -)

  • Hahn Sung-Ho;Yang Bo-Kyu;Yi Seung-Rim;Chung Shun-Wook;Hwang Hoon;Ko Dong-Oh;Kwon Gi-Doo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.1
    • /
    • pp.13-16
    • /
    • 2001
  • Purpose : To evaluate the types of the fibrous scar formation around graft after ACL reconstruction. Materials and Methods : Between Nov 1997 and Jun. 1999, the second look arthroscopy was performed on 15 knees of 14 patients. We evaluated the changes around graft and measured the tunnel position that the tibial tunnel position as a percentage along the length of the tibial plateau from the anterior-to-posterior as seen on a lateral radiograph and the femoral tunnel position as a percentage along Blumensaat's line from anterior-to-posterior as seen on a lateral radiograph. Results : The tibial tunnel position was from $27\%\;to\;58\%(mean\;41\%)$ and the femoral tunnel position was from $58\%\;to\;83\%(mean\;76\%)$, so the tunnel position was ideal in almost cases. By arthroscopic findings, the grafts were not impinged in all cases and tile fibrous scar was formed between intercondylar notch and graft in almost cases except 3 cases. The types of fibrous scar formation were 6 cases of fibrillated fiber and 5 cases of fibrous nodule and 1 case of fibrous band. Conclusion : There was no impingement on graft in all cases and various types of fibrous scars were formed around grafts.

  • PDF

Three Dimensional Ultrasonographic Evaluation with Intra-articular Saline Injection in Rotator Cuff Tear (회전근 개 파열의 수술 전 3차원 초음파 검사에서 관절내 생리식염수 주사 후 검사의 정확도)

  • Yum, Jae-Kwang;Shin, Yong-Woon;Park, Shin-Seung
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.2
    • /
    • pp.62-67
    • /
    • 2009
  • Purpose: The purpose of this study is to find out the accuracy and usability of the three dimensional ultrasonography in measuring the size of the rotator cuff tear, especially before and after the injection of normal saline into the glenohumeral joint. Materials and Methods: 14 patients of rotator cuff tear who were diagnosed and operated from August 2007 to September 2008 were included in this study and authors compared the size of rotator cuff tear measured with three dimensional ultrasonography with the real size measured intraoperatively. In preoperative ultrasonographic evaluation, horizontal and longitudinal length of rotator cuff tear before and after injection of normal saline intraarticularly. During the arthroscopic operation the size of tear was measured by passing a Kirschner wire through a spinal needle and direct measure was performed in open surgery. Results: The average difference was 8 mm in horizontal and 1.9 mm in longitudinal length of tear without saline injection between ultrasonographic and intraoperative measure. The average difference was 4.1 mm in horizontal and 1.6 mm in longitudinal length of tear after the normal saline injection. Conclusion: In three dimensional ultrasonographic evaluation in rotator cuff tear, intraarticular normal saline injection would produce more accurate results.

  • PDF

A Scheme for Increasing Fairness and System Utilization in ABR Traffic (ABR 트래픽의 공정성 및 시스템 효율성 증대를 위한 방안제시)

  • 정상준;권태경;송주석
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1998.10a
    • /
    • pp.380-382
    • /
    • 1998
  • ABR 은 ATM의 서비스 중에서 가장 최근에 추가된 것으로서 트래픽 소스의 전송률을 제어하기 위해서 피드백 메커니즘을 사용한다. ABR 서비스의 성능은 스위치를 통해서 피드백되는 RM 셀에 의해서 결정적인 영향을 받는다. ATM 표준에는 EPRCA, CAPC, ERICA 등의 알고리즘을 다루고 있다. 하지만 이러한 스위치 알고리즘에 대한 성능평가 및 분석 은 자세히 이루어지지 않고 있다. 본 논문에서는 현재 사용중인 ABR 스위치 알고리즘 중 단순히 큐의 길이에 위해 폭주를 판단하는 EPRCA 방법에 대해서 자세히 분석하고 EPRCA 의 단점을 극복하기 위해서 큐의 길이뿐만 아니라 새로운 변수 즉 평균 분산 및 표준편차을 이용해서 각 송신원의 공정성을 높이고 시스템의 효율성을 증대시키는 방안을 제시한다.

  • PDF

Anatomical Analysis of Superior Glenoid and Glenoid Labrum (상부 관절와 및 관절와 순의 해부학적 분석)

  • Choi, Nam-Yong;Song, Hyun-Seok;Yoon, Hyung-Moon;Choi, Seung-Gyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.2
    • /
    • pp.102-106
    • /
    • 2010
  • Purpose: The results of the repair for the superior labrum lesions attaching at the superior glenoid have not been satisfactory in every cases. We wanted to analyze the shoulder MRI and the anatomical morphology and pattern of the superior glenoid at which the superior labrum attaches to get anatomical information helpful in treating the superior labrum. Materials and Methods: We analyzed the coronal images of the shoulder MRI of 108 cases taken at our hospital. Average age was 52 years (range, 17~71 years), 55 males and 53 females. On two coronal images behind the attachment of the long head of biceps that the repair of the SLAP was performed at, the length of the attachment of superior labrum and the angle of the supero-lateral glenoid were measured. Results: The average length of the attachment of superior labrum was $9.78{\pm}1.64\;mm$. The average length was $10.1{\pm}1.61mm$ in male, $9.43{\pm}1.6\;mm$ in female. The angle of the supero-lateral glenoid was $89.6{\pm}7.6$ degrees. Conclusion: The attachment of the superior labrum in coronal plane was shorter in posterior spot than anterior. The angle of the supero-lateral glenoid was less in posterior spot.

  • PDF

Surgical Treatment of Osteoporotic Vertebral Compression Fractures at Thoraco-Lumbar Levels: Only Pedicle Screw Constructs with Polymethylmethacrylate Augmentation (흉요추부 골다공증성 척추 압박 골절의 수술적 치료: 골시멘트 보강술을 이용한 척추경 나사 고정)

  • Jun, Deuk Soo;Baik, Jong-Min;Park, Ji Hyeon
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.4
    • /
    • pp.327-335
    • /
    • 2019
  • Purpose: To investigate the radiological efficacy of polymethylmethacrylate (PMMA) augmentation of pedicle screw operation in osteoporotic vertebral compression fractures (OVCF) patients. Materials and Methods: Twenty OVCF patients, who underwent only posterior fusion using pedicle screws with PMMA augmentation, were included in the study. The mean follow-up period was 15.6 months. The demographic data, bone mineral density (BMD), fusion segments, number of pedicle screws, and amount of PMMA were reviewed as medical records. To analyze the radiological outcomes, the radiologic parameters were measured as the time serial follow-up (preoperation, immediately postoperation, postoperation 6 weeks, 3, 6 months, and 1 year follow-up). Results: A total of 20 patients were examined (16 females [80.0%]; mean age, 69.1±8.9 years). The average BMD was -2.5±0.9 g/cm2. The average cement volume per vertebral body was 6.3 ml. The mean preoperative Cobb angle of focal kyphosis was 32.7°±7.0° and was improved significantly to 8.7°±6.9° postoperatively (p<0.001), with maintenance of the correction at the serial follow-up, postoperatively. The Cobb angle of instrumented kyphosis, wedge angle, and sagittal index showed similar patterns. In addition, the anterior part of fractured vertebral body height averaged 11.0±5.0 mm and was improved to 18.5±5.7 mm postoperatively (p=0.006), with maintenance of the improvement at the 3-month, 6-month, and 1-year follow-up. Conclusion: The reinforcement of pedicle screws using PMMA augmentation may be a feasible surgical technique for OVCF. Moreover, it appears to be appropriate for improving the focal thoracolumbar/lumbar kyphosis and is maintained well after surgery.