• Title/Summary/Keyword: 평균절단수

Search Result 185, Processing Time 0.026 seconds

Cooling Time Determination of Spent Nuclear Fuel by Detection of Activity Ratio $^{l44}Ce /^{l37}Cs$ (방사능비 $^{l44}Ce /^{l37}Cs$ 검출에 의한 사용후핵연료 냉각기간 결정)

  • Lee, Young-Gil;Eom, Sung-Ho;Ro, Seung-Gy
    • Nuclear Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.237-247
    • /
    • 1993
  • Activity ratio of two radioactive primary fission products which had sufficiently different half-lives was expressed as functions of cooling time and irradiation histories in which average burnup, irradiation time, cycle interval time and the dominant fissile material of the spent fuel were included. The gamma-ray spectra of 36 samples from 6 spent PWR fuel assemblies irradiated in Kori unit-1 reactor were obtained by a spectrometric system equipped with a high purity germanium gamma-ray detector. Activity ratio $^{l44}$Ce $^{l37}$Cs, analyzed from each spectrum, was used for the calculation of cooling time. The results show that the radioactive fission products $^{l44}$Ce and $^{l37}$Cs are considered as useful monitors for cooling time determination because the estimated cooling time by detection of activity ratio $^{l44}$Ce $^{l37}$Cs agreed well with the operator declared cooling time within relative difference of $\pm$5 % despite the low counting rate of the gamma-ray of $^{l44}$Ce (about 10$^{-3}$ count per second). For the samples with several different irradiation histories, the determined cooling time by modeled irradiation history showed good agreement with that by known irradiation history within time difference of $\pm$0.5 year. From this result, it would be expected to be possible to estimate reliably the cooling time of spent nuclear fuel without the exact information about irradiation history. The feasibility study on identification of and/or sorting out spent nuclear fuel by applying the technique for cooling time determination was also performed and the result shows that the detection of activity ratio $^{l44}$Ce $^{l37}$Cs by gamma-ray spectrometry would be usefully applicable to certify spent nuclear fuel for the purpose of safeguards and management in a facility in which the samples dismantled or cut from spent fuel assemblies are treated, such as the post irradiation examination facility.mination facility.

  • PDF

Comparison of Saphenous Vein and PTFE Grafts for Above the Knee Femoropopliteal Bypass Grafting (슬상부 대퇴동맥-슬와동맥 우회이식술에서 복재정맥과 PTFE 이식편의 비교)

  • Kim, Han-Yong;Kim, Jong-Seok;Kim, Myoung-Young;Hwang, Sang-Won;Yoo, Byung-Ha
    • Journal of Chest Surgery
    • /
    • v.43 no.2
    • /
    • pp.127-132
    • /
    • 2010
  • Background: Femoropopliteal artery bypss grafting is an effective form of treatment for infrainguinal artery occlusive disease in those patients who have either intermittent claudication or resting critical ischemia. The objective of this analysis was to evaluate the long-term patency of a femoropopliteal bypass graft that is classified as an above-the-knee saphenous vein graft or an above-the-knee PTFE (polytetrafluoroethylene) graft. Material and Method:From January 1998 to February 2005, 103 above-the-knee femoro-popliteal bypasses were performed on 87 patients. There were 74 male and 13 female patients with a mean age of $65.7{\pm}9.69$ (range: 31~82). The surgical indications were intermittent claudication in 65 cases (74.7%), foot ulceration in 2 cases (2.3%), foot necrosis in 10 ases (11.5%) and toe necrosis in 10 cases (11.5%). For the bypass graft, a reversed saphenous vein was used in 31 limbs and a polytetrafluoroethylene (PTFE) prosthesis was used in 72 limbs (6 mm: 27 limbs, 8 mm: 45 limbs). The perioperative risk factors were diabetes mellitus in 33 cases (37.9%), hypertension in 47 cases (54.0%), a history of ischemic heart disease in 13 cases (14.9%) and smoking in 72 cases (82.8%). Result:There were three perioperative deaths (3.4%) and seven late deaths (8.3%). Major leg amputation was necessary in 12 patients (13.8%) during the entire course of the study. The primary patency rate at 5 years for the vein grafts, the 8 mm-PTFE grafts and the 6 mm-PTFE grafts were 84.7%, 77.4% and 74.2%, respectively and the overall primary patency rate was 78.7%, and there were no significant statistical differences among the graft groups. By using multivariate analysis, the number of patent tibial arteries was determined to be a significant factor that influenced the primary graft patency rate (p<0.005), but risk factors such as diabetes mellitus, ischemic heart disease, smoking and age had no statistically significant affect on the primary graft patency rates. Conclusion: The great saphenous vein is considered the most durable conduit for infrainguinal revascularization, but the overall results of this study show that saphenous vein and PTFE grafts have comparable patency rates when used above the knee in patients with claudication or critical ischemia. The use of PTFE above the knee is a reasonable alternative for a femoro-poplitael bypass and it is associated with acceptable long term patency rates.

Dose Distribution and Characterization for Radiation Fields of Multileaf Collimateor System (방사선 입체조형치료용 다엽콜리메이터의 특성과 조직내 선량분포 측정)

  • Chu, Sung-Sil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.77-85
    • /
    • 1996
  • Purpose : Multileaf collimator(MLC) is very suitable tool for conformal radio-therapy and commissioning measurements for a multileaf collimator installed on a dual energy accelerator with 6 and 10MV photons are required, For modeling the collimator with treament planning software, detailed dosimetric characterization of the multileaf collimator including the penumbra width, leaf transmission between leaf leakage and localization of the leaf ends and sides is an essential requirement. materials and Methods : Measurement of characteristic data of the MLC with 26 pair block leaves installed on CLINAC 2100C linear accelerator was performed. Low sensitive radiographic film(X-omatV) was used for the penumbra measurement and separate experiments using radiographic film and thermoluminescent dosimeters were performed to verify the dose distribution, Measured films were analized with a photodensitometer of WP700i scanner. Results : For 6 & 10 MV x-ray energies, approximately $2.0\%$ of photons incident on the multileaf collimator were transmitted and an additional $0.5\%$ leakage occurs between the leaves. Localizing the physical end of the leaves showed less than 1mm deviation from the $50\%$ decrement line and this difference is attributed to the curved shaped end on the leaves One side of a sin히e leaf corresponded to the $50\%$ decrement line, but the opposite face was aligned with a lower value. This difference is due to the tongue and groove used to decrease between leaf leakage. Alignment of the leaves to form a straight edge resulted larger penumbra at far position from isocenter as compare with divergent alloy blocks. When the MLC edge is stepped by sloping field, the isodose lines follow the leaf pattern and Produce scalloping isodose curves in tissue. The effective penumbra by 45 degree stepped MLC is about 10mm at 10cm depth for 6MV x-ray. The difference of effective penumbra in deep tissue between MLC and divergent alloy blocks is small (5mm). Conclusion : Using the characteristic data of MLC, the MLC has the clinlical acceptability and suitability for 3-D conformal radiotherapy except small field size.

  • PDF

The Effect of Surface Defects on the Cyclic Fatigue Fracture of HEROShaper Ni-Ti rotary files in a Dynamic Model: A Fractographic Analysis (Fractographic 분석을 통한 HEROShaper 니켈티타늄 전동 파일의 피로파절에 미치는 표면결함의 역할)

  • Lee, Jung-Kyu;Kim, Eui-Sung;Kang, Myoung-Whai;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.2
    • /
    • pp.130-137
    • /
    • 2007
  • This in vitro study examined the effect of surface defects on cutting blades on the extent of the cyclic fatigue fracture of HEROShaper Ni-Ti rotary files using fractographic analysis of the fractured surfaces. A total of 45 HEROShaper (MicroMega) Ni-Ti rotary flies with a #30/.04 taper were divided into three groups of 15 each. Group 1 contained new HEROShapers without any surface defects. Group 2 contained HEROShapers with manufacturing defects such as metal rollover and machining marks. Croup 3 contained HEROShapers that had been clinically used for the canal preparation of 4-6 molars A fatigue-testing device was designed to allow cyclic tension and compressive stress on the tip of the instrument whilst maintaining similar conditions to those experienced in a clinic. The level of fatigue fracture time was measured using a computer connected the system. Statistical analysis was performed using a Tukey's test. Scanning electron microscopy (SEM) was used for fractographic analysis of the fractured surfaces. The fatigue fracture time between groups 1 and 2, and between groups 1 and 3 was significantly different (p<0.05) but there was no significant difference between groups 2 and 3 (p>0.05). A low magnification SEM views show brittle fracture as the main initial failure mode At higher magnification, the brittle fracture region showed clusters of fatigue striations and a large number of secondary cracks. These fractures typically led to a central region of catastrophic ductile failure. Qualitatively, the ductile fracture region was characterized by the formation of microvoids and dimpling. The fractured surfaces of the HEROShapers in groups 2 and 3 were always associated with pre-existing surface defects. Typically, the fractured surface in the brittle fracture region showed evidence of cleavage (transgranular) facets across the grains, as well as intergranular facets along the grain boundaries. These results show that surface defects on cutting blades of Ni-Ti rotary files might be the preferred sites for the origin of fatigue fracture under experimental conditions. Furthermore this work demonstrates the utility of fractography in evaluating the failure of Ni-Ti rotary flies.

A Clinical Study about Effectiveness of Essential Oil-Containing Dental Paste in Controlling Oral Malodor (아로마 함유 치약이 구취에 미치는 영향에 관한 임상적 연구)

  • Jeon, Lee-Sun;Kang, Soo-Kyung;Chun, Yang-Hyun;Hong, Jung-Pyo
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.2
    • /
    • pp.141-148
    • /
    • 2005
  • Since many reports for the influence of the essential oils on the oral microorganism were presented, it is important to use the essential oils in clinical field. At the present day which emphasized the quality of life, oral malodor is one of the serious problems, so we need to try to decrease of oral malodor. This study was designed to make on evidence of the effect of essential oils to oral malodor clinically and to develop on effective treatment for oral malodor by using the dental paste which contains essential oils. 40 dental students volunteered to participate in this study and double blind test was used. At the beginning, all subjects were measured their morning malodor prior to this experiment, at the 3cm posterior to their incisal edge of the oral cavity by Halimeter(Interscan Co. Chatsworth, CA). After that we divided the students in half into two groups A and B. We have supplied different tooth pastes, dental paste A and B, to two groups respectively. The dental paste B contained essential oils which are tea tree, lemon and peppermint. All students used different tooth pastes everyday for 3 weeks. And all students were measured their morning malodor every week with the same method by using Halimeter. This study was resulted that ; 1. The dental paste which contains essential oils has continuously decreased the morning malodor during the whole period of experiments. 2. The number of students with increase in their morning malodor was generally decreased in the group B who used the toothpaste which contains essential oils, compared with the group A who used the toothpaste which didn't contain essential oils on the 2nd and 3rd week of the experiment. 3. In the group B, the average data on increasing rate of morning malodor was less than in the group A. 4. In the 2nd and 3rd week of the experiment, the data on the rate of morning malodor of the group B was generally decreased continuously compared with the group A. These results have statistically significance under 95% confidence interval of the difference.(p$\leq$0.05) As the result, the toothpaste which was containing essential oils was effective in decreasing the morning malodor.

Prognostic Factors in Postpsychotic Depressive Disorder of Schizophrenia (정신분열증의 정신증 후 우울장애의 예측인자)

  • Kim, Jin-Sung;Lee, Jong-Bum;Seo, Wan-Seok;Koo, Bon-Hoon;Bae, Dae-Seok;Kim, Yi-Youg;Kim, Jung-Youp
    • Journal of Yeungnam Medical Science
    • /
    • v.22 no.2
    • /
    • pp.150-165
    • /
    • 2005
  • Purpose: This study was conducted to investigate the prognostic factors of postpsychotic depressive symptoms in patients with schizophrenia. Materials and Methods: Eighty patients were selected based on the diagnostic criteria from the DSM-IV, PANSS and ESRS. For all patients information was collected on demographic and clinical characteristics. The subjective depressive symptoms and the objective depressive symptoms, as well as patients insight regarding psychosis were evaluated. The subjective depressive symptoms were evaluated by BDI and ZDS; the objective depressive symptoms were evaluated by HDRS and CDSS, and patient insight into the psychosis was evaluated by KISP. Results: The comparisons using demographic and clinical characteristics showed that HDRS and CDSS had significant difference with regard to gender and suicide attempts; the BDI was associated with difference in education level and age of onset. The patients with scores above cuff-off score for each scale were 20(25.0%) for the BDI, 16(20.0%) for the ZDS, 18(22.5%) for the CDSS and 6(7.5%) for the HDRS. The results of the stepwise multiple regression analysis showed that the scores for the KISP, education levels, gender and suicide attempts were the main prognostic factors in patients with the psychotic depressive disorder of schizophrenia. Conclusion: The main prognostic factors in psychotic depressive disorder of schizophrenia included: insight into psychosis, suicidal attempts. Insight into the psychosis was the most reliable prognostic factor but this characteristic had a negative relationship to the with depressive symptoms.

  • PDF

Experimental Study of Flip-Bucket Type Hydraulic Energy Dissipator on Steep slope Channel (긴구배수로 감세공의 Filp Bucket형 이용연구)

  • 김영배
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.13 no.1
    • /
    • pp.2206-2217
    • /
    • 1971
  • Spillway and discharge channel of reservoirs require the Control of Large volume of water under high pressure. The energies at the downstream end of spillway or discharge channel are tremendous. Therefore, Some means of expending the energy of the high-velocity flow is required to prevent scour of the riverbed, minimize erosion, and prevent undermining structures or dam it self. This may be accomplished by Constructing an energy dissipator at the downstream end of spillway or discharge channel disigned to dissipated the excessive energy and establish safe flow Condition in the outlet channel. There are many types of energy dissipators, stilling basins are the most familar energy dissipator. In the stilling basin, most energies are dissipated by hydraulic jump. stilling basins have some length to cover hydraulic jump length. So stilling basins require much concrete works and high construction cost. Flip bucket type energy dissipators require less construction cost. If the streambed is composed of firm rock and it is certain that the scour will not progress upstream to the extent that the safety of the structure might be endangered, flip backet type energy dissipators are the most recommendable one. Following items are tested and studied with bucket radius, $R=7h_2$,(medium of $4h_2{\geqq}R{\geqq}10h_2$). 1. Allowable upstream channel slop of bucket. 2. Adequate bucket lip angle for good performance of flip bucket. Also followings are reviwed. 1. Scour by jet flow. 2. Negative pressure distribution and air movement below nappe flow. From the test and study, following results were obtained. 1. Upstream channel slope of bucket (S=H/L) should be 0.25<H/L<0.75 for good performance of flip bucket. 2. Adequated lip angle $30^{\circ}{\sim}40^{\circ}$ are more reliable than $20^{\circ}{\sim}30^{\circ}$ for the safety of structures.

  • PDF

HISTOLOGIC FEATURE AND INFILTRATION OF ADHESIVE RESIN ACCORDING TO PRETREATMENT ON PROXIMAL EARLY CARIES LESION (평활면 초기 우식병소의 표면처리에 따른 조직상 및 접착제의 침투 양상 비교)

  • Kim, In-Young;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.1
    • /
    • pp.30-37
    • /
    • 2009
  • Early enamel caries is commonly remineralized by the patient‘s improved oral hygiene or fluoridation, however the result is clinically unreliable. As an alternative, we tried to seal the lesions with low-viscosity light-curing resin. The aim of the present study was to search the proper methods of the adequate pretreatment prior to applying adhesive resin on natural proximal caries lesions. Thirty nine extracted deciduous molar teeth showing proximal early caries lesion were used for this study. They were divided into 5 groups : Group 1; only carefully cleaned with water, group 2; etched with 15% HCl for 15s, group 3; etched with 35% phosphoric acid for 15s, group 4; etched with 35% phosphoric acid for 30s, and group 5; cleaned with 0.5% NaOCl. Following results were obtained by evaluating with SEM and CLSM after applied with adhesive resin. 1. As a result of SEM evaluation, group 2 showed clearly removed surface layer, group 3,4 showed partially removed surface layer irregularly, group 5 showed slightly removed surface layer. 2. Group 2 showed the deepest infiltration depth, followed by group 4, group 3, group 5, group 1 and besides group 5, other groups showed significantly deep infiltration depth. (p < 0.01) In conclusion, the best methods of the adequate pretreatment on natural proximal caries lesion for deep infiltration of adhesive resin was to etch with 15% HCl for 15s.

  • PDF

Embolectomy of Arteries of Extremities -Clinical analysis of 26 cases (사지동맥의 색전제거술 -26례의 분석-)

  • 강종렬;구본일
    • Journal of Chest Surgery
    • /
    • v.30 no.2
    • /
    • pp.172-178
    • /
    • 1997
  • We present a etrospective analysis of arterial embolectomies performed at the Inje University Seoul Paik Hospital. During the period of March 1987 Feburary 1996 twenty-six patients underwent embolectomies, eighteen patients were male and eight patients were female, mean age of patients was 56.8 years. Rest pain was the chief complaint in 24 patients, the remaining two patients complained of long term history of claudication after recovery of acute symtoms. But only 10 patients had sensBrylmotor symtoms. Heart was the most common source of embolization and frequent predisposing factor of embolism was ischemic heart disease in 8 cases and valvular heart disease in 11 cases. The sites of embolization were upper extremities artery in 6 cases, saddle embolism in 2 cases, lower extremities artery in 18 cases and the most common site of embolism was femoral artery in 1 1 cases. Preoperative angiography was taken in the diagnosis and planning of the embolectomy in 1) patients while in the other patient p eoperative angiography was not taken. Only two cases were operated within the golden period of 6 hours and other cases were operated in more than 6 hours after embolization. In all patients, the Fogarty embolectomy catheter was used without bypass surgery via bachial ateriotomy in the embolism of upper extremities artery, bilateral groin approaches in the saddle embolism and transfemoral approach in the embolism of lower extremities artery. However 3 patients were re-operated via transpopliteal approach in the distal poplitiotibial embolism. Eighteen patients received perioperative anticoagulation therapy by heparin or fraxiparine and wafarin was used in 17 patients at the time of discharge and the indication of anticogulation was patients of valvular heat disease andfor atrial fibrillation, peripheral artery atherosclerosis and recurrent embolism. Postoperative results of the embolectomy were as follows: fouteen pateints had excellent results, five cases had symtom improvement after re-operation, B. K. amputation in 1 case who had severe atherosclerosis of lower extremities, recurrent embolism in 1 case and death in 2 cases the cause of death were acute renal failure and cerebral artery embolism, respectively. The complications of the embolectomy were reperfusion syndrome, pseudoaneurysm and intimal dissection in one case each. Conclusively the problems of embolism is delayed diagnosis and increasing number of old aged patient who had suffered from ischemic heart diease. Preoperative angiography was not always needed for embol ectomy. Selective anticoagulation therapy can decrease incidence of re-embolism. In the distal poplitiotibial embolism, embolectomy of tibial artery was difficult.

  • PDF

Retentive bond strength of fiber-reinforced composite posts cemented with different surface treatments (Fiber reinforced composite post의 표면 처리에 따른 접착 강도)

  • Roh, Hyunsik;Noh, Kwantae;Woo, Yi-Hyung;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.2
    • /
    • pp.113-120
    • /
    • 2014
  • This study will evaluate the effectiveness of various pretreatments when fiber-reinforced composite (FRC) post is bonded to endodontically treated tooth with resin cement. Materials and methods: Canal shaping of FRC post (DT Light post, Size 3, Bisco Inc., Schaumburg, IL, USA) was performed on endodontically treated premolars at 1.5 cm from CEJ. Samples were divided into 6 groups of surface treatment after conventional washing and drying to the canal. Total of 24 FRC posts were randomly divided into 6 groups of surface treatment as follows: Group C: control - no surface treatment, Group A: airborne-particle abrasion (Cojet sand, 3M ESPE), Group S: silanization (Bis-silane, Bisco Inc.), Group M: universal primer (Monobond-plus primer, Ivoclar Vivadent Inc.), Group AS: silanization after airborne-particle abrasion, Group AM: universal primer treatment after airborne-particle abrasion. Pretreated fiber posts were cemented with resin-based luting material and photo-polymerized and cut to the thickness of 1 mm. Push-out test using a universal testing machine was performed. Bonding failure strength of post dislodgement was measured and the type of bonding failure was classified. Data were analyzed with Kruskal-Wallis test and multiple comparison groups were performed using Tukey HSD value of rank test (${\alpha}=0.05$). Results: Group AS showed significantly highest bonding strength. Group S, group AM, group A, and group M showed lower bonding strength in order. The control group showed the lowest bonding strength. Conclusion: Surface treatment with silane showed to be the most effective of the surface pretreatment methods for cementation of FRC post. Surface treatment with universal primer showed no significant difference compared with no surface treatment group as for bonding strength.