• Title/Summary/Keyword: 평균값

Search Result 2,291, Processing Time 0.07 seconds

Design and Utilization of climagraph for Analysis of Regional Suitability of Greenhouse Cropping in Korea (국내 온실재배의 적지성 분석을 위한 Climagraph의 작성과 이용)

  • 이현우;이석건;이종원
    • Journal of Bio-Environment Control
    • /
    • v.9 no.2
    • /
    • pp.107-114
    • /
    • 2000
  • We constructed climagraphs for 16 regions of Korea by using the average monthly minimum air temperature, maximum air temperature and global radiation. We characterized the outside climate requirements corresponding to the climate requirements of crops in greenhouses. The climagraphs allow to decide the appropriate climate periods for greenhouse cultivation without heating and cooling equipment. These graphs may be used for analyzing climatic characteristic of a given area, selecting the suitable region and greenhouse and making a rational plan for greenhouse cropping in Korea. We found difficulty in deciding the beginning and end of greenhouse heating and cooling period due to insufficient references.

  • PDF

A Study on Image Binarization using Intensity Information (밝기 정보를 이용한 영상 이진화에 관한 연구)

  • 김광백
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.3
    • /
    • pp.721-726
    • /
    • 2004
  • The image binarization is applied frequently as one part of the preprocessing phase for a variety of image processing techniques such as character recognition and image analysis, etc. The performance of binarization algorithms is determined by the selection of threshold value for binarization, and most of the previous binarization algorithms analyze the intensity distribution of the original images by using the histogram and determine the threshold value using the mean value of Intensity or the intensity value corresponding to the valley of the histogram. The previous algorithms could not get the proper threshold value in the case that doesn't show the bimodal characteristic in the intensity histogram or for the case that tries to separate the feature area from the original image. So, this paper proposed the novel algorithm for image binarization, which, first, segments the intensity range of grayscale images to several intervals and calculates mean value of intensity for each interval, and next, repeats the interval integration until getting the final threshold value. The interval integration of two neighborhood intervals calculates the ratio of the distances between mean value and adjacent boundary value of two intervals and determine as the threshold value of the new integrated interval the intensity value that divides the distance between mean values of two intervals according to the ratio. The experiment for performance evaluation of the proposed binarization algorithm showed that the proposed algorithm generates the more effective threshold value than the previous algorithms.

Development of Algorithms for Correcting and Mapping High-Resolution Side Scan Sonar Imagery (고해상도 사이드 스캔 소나 영상의 보정 및 매핑 알고리즘의 개발)

  • 이동진;박요섭;김학일
    • Korean Journal of Remote Sensing
    • /
    • v.17 no.1
    • /
    • pp.45-56
    • /
    • 2001
  • To acquire seabed information, the mosaic images of the seabed were generated using Side Scan Sonar. Short time energy function which is needed for slant range correction is proposed to get the height of Tow-Fish to the reflected acoustic amplitudes of each ping, and that leads to a mosaic image without water column. While generating mosaic image, maximum value, last value and average value are used for the measure of a pixel in the mosaic image and 3-D information was kept by using acoustic amplitudes which were heading for specific direction. As a generating method of mosaic image, low resolution mosaic image which is over 1m/pixel resolution was generated for whole survey area first, and then high resolution mosaic image which is generated under 0.1m/pixel resolution was generated for the selected area. Rocks, ripple mark, sand wave, tidal flat and artificial fish reef are found in the mosaic image.

Analysis of evapotranspiration in the Imjin River Basin (임진강 유역의 증발산량 분석)

  • Dong Phil Kim;Joo Hun Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.323-323
    • /
    • 2023
  • 유역의 증발산량 자료는 물순환 과정을 규명하는 매우 중요한 자료 중의 하나이며, 물순환 성분별 명확한 산정 결과는 수자원 개발과 물환경 보전에 중요한 정보를 제공할 수 있다. 본 논문에서는 임진강 유역(유역출구(한강합류점) 기준, 유역면적 8,138.9km2)을 대상으로 5개년(2018~2022) 기상관측자료를 이용하여 증발산량을 산정하였으며, 그 외의 수문관측자료를 통해 물수지 분석도 수행하였다. 증발산량 산정은 세계식량기구(FAO)에서 제시한 Penman-Monteith equation을 적용하여 일별증발산량을 산정하였으며, 작물의 종류에 따른 계수는 잔디의 경우를 채택하였다. 본 방정식을 통해 산정된 증발산량(ETo)은 기준작물에 수분의 공급에 제한이 없는 상황에서 산정된 기준 증발산량(reference evapotranspiration)을 의미하며, 기준 증발산량을 실제 증발산량으로 변환하기 위해서는 작물계수를 고려해야 한다. 작물계수는 식생의 높이, 알베도, 식생의 저항, 토양으로부터의 증발 등의 영향을 받게 되나, 더욱더 명확하게는 식물에서의 증산을 설명하는 기본 작물계수와 토양에서의 증발을 설명하는 토양계수의 합을 통해 계수를 산정하게 된다. 임진강 유역에 공간적으로 분포된 작물계수를 정확히 산정하기에는 한계가 있으므로 잔디의 경우로 한정하여 산정된 기준 증발량은 833.0mm(5개년 평균값)이다. 각 물순환 성분별로 생성된 임진강 유역의 5개년 평균값인 유역평균강우량은 1,412.9mm이며, 하천유출량은 804.9mm(유역평균강우량 대비 57.0%), 실제 증발산량은 442.3mm(유역평균강우량 대비 31.3%, 기준 증발산량 대비 약 53.0%), 유역저류량은 165.7mm(유역평균강우량 대비 11.7%)이다. 유역평균강우량은 8개 관측소(양덕, 원산, 신계, 개성, 평강, 철원, 동두천, 파주) 강우량의 유역평균값이며, 하천유출량은 유역출구의 상류 관측소인 비룡대교 관측소(유역면적 6,784.0km2) 유출량의 유역면적비 적용값이다. 실제 증발산량은 기준 증발산량 산정값에 해당 유역내 존재하는 설마천 유역의 기준 증발산량과 실제 증발산량 비율(약 53.0%)을 적용한 값이며, 유역저류량은 전제적인 물수지 분석을 통해 얻어진 추정값이다. 이와 같이 산정된 물순환 성분별 자료는 유역의 물순환 과정 규명을 위한 기초자료로 매우 유용하게 활용될 수 있으며, 유역 물관리를 위한 의사결정 과정에 중요한 역할을 할 수 있을 것으로 기대된다.

  • PDF

Analysis of evapotranspiration in the Seolmacheon catchment (설마천 유역의 증발산량 분석)

  • Dong Phil Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.322-322
    • /
    • 2023
  • 유역의 증발산량 자료는 물순환 과정을 규명하는 매우 중요한 자료 중의 하나이며, 물순환 성분별 명확한 산정 결과는 수자원 개발과 물환경 보전에 중요한 정보를 제공할 수 있다. 본 논문에서는 한국건설기술연구원에서 운영하는 설마천 유역(전적비교 수위관측소 기준, 유역면적 8.48km2)의 5개년(2018~2022) 기상관측자료를 이용하여 증발산량을 산정하였으며, 그 외 강우량, 하천유출량, 지하수함양량 자료를 이용하여 물수지 분석도 수행하였다. 증발산량 산정은 세계식량기구(FAO)에서 제시한 Penman-Monteith equation을 적용하여 일별 증발산량을 산정하였으며, 작물의 종류에 따른 계수는 잔디의 경우를 채택하였다. 본 방법을 통해 산정된 증발산량(ET0)은 기준작물에 수분의 공급에 제한이 없는 상황에서 산정된 기준 증발산량(reference evapotranspiration)을 의미하며, 기준 증발산량을 실제 증발산량으로 변환하기 위해서는 작물계수를 고려해야 한다. 작물계수는 식생의 높이, 알베도, 식생의 저항, 토양으로부터의 증발 등의 영향을 받게 되나, 더욱더 명확하게는 식물에서의 증산을 설명하는 기본 작물계수와 토양에서의 증발을 설명하는 토양계수의 합을 통해 계수를 산정하게 된다. 설마천 유역에 공간적으로 분포된 작물계수를 정확히 산정하기에는 한계가 있으므로 잔디의 경우로 한정하여 산정된 기준증발량은 885.9mm(5개년 평균값)이다. 각 물순환 성분별로 생성된 설마천 유역의 5개년 평균값인 유역평균강우량은 1,307.3mm이며, 하천유출량은 799.7mm(유역평균강우량 대비 61.2%), 실제 증발산량은 469.5mm(유역평균강우량 대비 35.9%, 기준 증발산량 대비 약 53.0%), 유역저류량은 38.1mm(유역평균강우량 대비 2.9%)이다. 유역평균강우량은 3개 관측소(감악산, 설마리, 전적비교) 강우량의 유역평균값이며, 하천유출량은 유역출구의 수위-유량관계곡선식 환산유량, 유역저류량은 과거년(2012~2018)의 지하수 관측자료를 통해 산정된 지하수함양량을 기초로 하였다. 그리고 실제 증발산량은 기준 증발산량 산정값과 전체적인 물수지 분석을 통해 얻어진 값이다. 이와 같이 산정된 물순환 성분별 자료는 유역의 물순환 과정 규명을 위한 기초자료로 매우 유용하게 활용될 수 있으며, 유역 물관리를 위한 의사결정 과정에 중요한 역할을 할 수 있을 것으로 기대된다.

  • PDF

Usability Evaluation of Applied Low-dose CT When Examining Urinary Calculus Using Computed Tomography (컴퓨터 단층촬영을 이용한 요로결석 검사에서 저선량 CT의 적용에 대한 유용성 평가)

  • Kim, Hyeon-Jin;Ji, Tae-Jeong
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.6
    • /
    • pp.81-85
    • /
    • 2017
  • The aim of this study was to evaluate the usability of applied Low dose Computed Tomography(LDCT) protocol in examining urinary calculus using computed tomography. The subjects of this study were urological patients who visited a medical institution located in Busan from June to December 2016 and the protocol used in this study was Adaptive Statistical Iterative Reconstruction: low-dose CT with 50% Adaptive Statistical Iterative Reconstruction (ASIR). As results of quantitative analysis, the mean pixel value and standard deviation within kidney region of image(ROI)of the axial image were $26.21{\pm}7.08$ in abdomen CT pre scan and $20.03{\pm}8.16$ in low-dose CT. Also the mean pixel value and standard deviation within kidney ROI of the coronal image were $22.07{\pm}7.35$ in abdomen CT pre scan and $21.67{\pm}6.11$ in low dose CT. The results of qualitative analysis showed that four raters' mean values of observed kidney artifacts were $19.14{\pm}0.36$ when using abdomen CT protocol and $19.17{\pm}0.43$ in low-dose CT, and the mean value of resolution and contrast was $19.35{\pm}0.70$ when using abdomen CT protocol and $19.29{\pm}0.58$ in low-dose CT. Also the results of a exposure dose analysis showed that the mean values of CTDIvol and DLP in abdomen CT pre scan were 18.02 mGy and $887.51mGy{\cdot}cm$ respectively and the mean values of CTDIvol and DLP when using low-dose CT protocol were 7.412 mGy and $361.22mGy{\cdot}cm$ respectively. The resulting dose reduction rate was 58.82% and 59.29%, respectively.

Evaluate the implementation of Volumetric Modulated Arc Therapy QA in the radiation therapy treatment according to Various factors by using the Portal Dosimetry (용적변조회전 방사선치료에서 Portal Dosimetry를 이용한 선량평가의 재현성 분석)

  • Kim, Se Hyeon;Bae, Sun Myung;Seo, Dong Rin;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.167-174
    • /
    • 2015
  • Purpose : The pre-treatment QA using Portal dosimetry for Volumetric Arc Therapy To analyze whether maintaining the reproducibility depending on various factors. Materials and Methods : Test was used for TrueBeam STx$^{TM}$ (Ver.1.5, Varian, USA). Varian Eclipse Treatment planning system(TPS) was used for planning with total of seven patients include head and neck cancer, lung cancer, prostate cancer, and cervical cancer was established for a Portal dosimetry QA plan. In order to measure these plans, Portal Dosimetry application (Ver.10) (Varian) and Portal Vision aS1000 Imager was used. Each Points of QA was determined by dividing, before and after morning treatment, and the after afternoon treatment ended (after 4 hours). Calibration of EPID(Dark field correction, Flood field correction, Dose normalization) was implemented before Every QA measure points. MLC initialize was implemented after each QA points and QA was retried. Also before QA measurements, Beam Ouput at the each of QA points was measured using the Water Phantom and Ionization chamber(IBA dosimetry, Germany). Results : The mean values of the Gamma pass rate(GPR, 3%, 3mm) for every patients between morning, afternoon and evening was 97.3%, 96.1%, 95.4% and the patient's showing maximum difference was 95.7%, 94.2% 93.7%. The mean value of GPR before and after EPID calibration were 95.94%, 96.01%. The mean value of Beam Output were 100.45%, 100.46%, 100.59% at each QA points. The mean value of GPR before and after MLC initialization were 95.83%, 96.40%. Conclusion : Maintain the reproducibility of the Portal Dosimetry as a VMAT QA tool required management of the various factors that can affect the dosimetry.

  • PDF

Comparison of the Antioxidative Abilities of Commercial Gal Geun Tang (시판 갈근탕의 항산화능의 비교)

  • Kim, Dong-Ryul;Kwak, Gael-Sun;Jeong, Seok-Moon;Lee, Seung-Cheol;Ha, Jung-Uk
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.32 no.5
    • /
    • pp.728-732
    • /
    • 2003
  • Each 3 g of five different commercial Gal Geun Tang extractive granules was mixed with 97 $m\ell$ of methanol or water for 1.5 hour at room temperature and filtered through a Whatman No. 1 filter paper, and the filtrate was used to determine antioxidant activity. Antioxidative abilities of each extracts were compared by measuring total phenol content (TPC), electron donating ability (EDA), inhibition of lipid peroxidation, and reducing power Average TPC of methanol extracts from five samples was 0.14 mM within the range of 0.07~0.23 mM, while that of water extracts was 0.23 mM, higher than that of methanol extracts. Average EDA of the methanol extracts was 85.54%, higher than that of the 0.1% BHT (72.26%). Average EDA values of the water extracts were 69.7%. Average value of inhibition against lipid peroxidation of the methanol extracts was 26.95%, and the range of five samples was 17.02~37.36%. Inhibition against lipid peroxidation of the water extracts showed relatively low value, 18.62%. Reducing power of the methanol extracts was 0.77 unit, which was 73.1% of 0.1% BHT, and that of water extracts was 0.88 unit. These results indicate that commercial Gal Geun Tang shows high antioxidant ability, though there are some differences depending on extract solvent and manufacturing company.

Characterization of the Three Dimensional Roughness of Rock Joints and Proposal of a Modified Shear Strength Criterion (암석 절리의 3차원 거칠기 특성화와 수정 전단강도 관계식의 제안)

  • Jang, Bo-An;Kim, Tae-Ho;Jang, Hyun-Sick
    • The Journal of Engineering Geology
    • /
    • v.20 no.3
    • /
    • pp.319-327
    • /
    • 2010
  • Surface roughness profiles were measured from 19 joint samples using a laser scanner, and Joint Roughness Coefficient (JRC) values were calculated from 30 sections in each sample. Although JRC values varied with the location of the section, the average JRC values from any three sections provides an adequate representation of the average JRC value for the entire surface well. Direct shear tests were performed on nine joints reproduced using molds of real joints in samples of gypsum. The peak friction angles (${\phi}_p$) showed a linear relationship with the average JRC values, yielding the following relationship: ${\phi}_p=41.037+1.046JRC$. However, the shear strengths measured by direct shear tests differed from those calculated using Barton's criterion. The relationship between calculated from direct shear tests and JRC measured from joint surfaces is defined as $JRC_R=f{\cdot}JRC$, and the correction coefficient f is was calculated as $f=3.15JRC^{-0.5}$, as calculated by regression. A modified shear-strength criterion, is proposed using the correction coefficient, ${\tau}={\sigma}_n{\cdot}tan(3.15JRC^{0.5}{\bullet}{\log}_{10}\frac{JCS}{{\sigma}_n}+{\phi}_b)$. This criterion may be effective in calculating the shear strength of moderately weathered rock joints and highly weathered rock joints with low strength and ductile behavior.

Establishment of standards for evaluation of health related fitness according to the working styles of male manufacturing workers (남성 제조업 근로자의 근무형태에 따른 건강 체력 평가기준 설정)

  • Ka, Sung-Soon;Lee, Gyu-Seung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.8
    • /
    • pp.190-199
    • /
    • 2017
  • The purpose of this study is to propose the standard of health-related fitness evaluation according to the working styles of male manufacturing workers. The subjects were 15,329 male manufacturing workers aged from 40 to 59 years old who had taken a health-related fitness test by K Institution. Health-related fitness components are cardiorespiratory endurance, muscular strength, muscular endurance, flexibility and body composition. We measured Vo2max, grip strength, sit-up, trunk flexion forward, and body fat percentage to ascertain each component. Data were analyzed with Two-way ANOVA, T-test, One-way ANOVA(Scheffe) and Percentile using SPSS version 18.0 program. The analysis results are as follows. First, the health-related fitness of manufacturing workers varied significantly according to their working styles(maximum oxygen uptake : F=88.67(p<.001), grip strength : F=20.09(p<.001), sit-up : F=42.06(p<.001), trunk flexion forward : F=69.44(p<.001), body fat percentage : F=136.75(p<.001)).Therefore, the evaluation standard was set based on the percentile of health fitness items. Second, the average Vo2max, grip strength, and trunk flexion forward of blue-collar workers were higher than those of white-collar workers at all ages. On the other hand, the average sit-up and body fat percentage of white-collar workers were higher than those of blue-collar workers at all ages. Third, these evaluation criteria differed greatly when compared with the results of the National Physical Fitness Survey. Therefore, we have confirmed that the evaluation criteria should be applied differently according to the working style of a worker when evaluating his health-related fitness.