• Title/Summary/Keyword: 평가주기

Search Result 2,497, Processing Time 0.034 seconds

Periodic Safety Review of Wolsong Unit 1 - Environmental Impact as gaseous and liquid effluents (월성 1호기 주기적안전성평가 - 기체 및 액체 방사성폐기물에 의한 환경영향)

  • 김성민;이은미;김미자;이갑복;정양근;엄희문
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.455-462
    • /
    • 2003
  • According to Korean nuclear code requires Periodic Safety Review(PSR) every 10 years should be perform for operating reactor, and selects the eleven PSR safety factors. Among them the review objective of the environmental impact is to determine whether the operator has an adequate programme for surveillance of the environmental impact of the nuclear power plant based on current safety standards. In this paper, the environmental impact in PSR of Wolsong Unit 1 was reflected current safety standards as of the evaluation date. As a result, all items generally satisfied the standards, and the staff also verified that the population dose due to the operation of Wolsong Unit 1 was controlled safely as of the evaluation date.

  • PDF

Efficacy of a Respiratory Training System on the Regularity of Breathing (호흡연습장치를 적용한 호흡교정법의 영향 평가)

  • Shin, Eun-Hyuk;Park, Hee-Chul;Han, Young-YIh;Ju, Sang-Gyu;Shin, Jung-Suk;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.26 no.3
    • /
    • pp.181-188
    • /
    • 2008
  • Purpose: In order to enhance the efficiency of respiratory gated 4-dimensional radiation therapy for more regular and stable respiratory period and amplitude, a respiration training system was designed, and its efficacy was evaluated. Materials and Methods: The experiment was designed to measure the difference in respiration regularity following the use of a training system. A total of 11 subjects (9 volunteers and 2 patients) were included in the experiments. Three different breathing signals, including free breathing (free-breathing), guided breathing that followed training software (guided-breathing), and free breathing after the guided-breathing (post guided-breathing), were consecutively recorded in each subject. The peak-to-peak (PTP) period of the breathing signal, standard deviation (SD), peak-amplitude and its SD, area of the one cycle of the breathing wave form, and its root mean square (RMS) were measured and computed. Results: The temporal regularity was significantly improved in guided-breathing since the SD of breathing period reduced (free-breathing 0.568 vs guided-breathing 0.344, p=0.0013). The SD of the breathing period representing the post guided-breathing was also reduced, but the difference was not statistically significant (free-breathing 0.568 vs. guided-breathing 0.512, p=ns). Also the SD of measured amplitude was reduced in guided-breathing (free-breathing 1.317 vs. guided-breathing 1.068, p=0.187), although not significant. This indicated that the tidal volume for each breath was kept more even in guided-breathing compared to free-breathing. There was no change in breathing pattern between free-breathing and guided-breathing. The average area of breathing wave form and its RMS in postguided-breathing, however, was reduced by 7% and 5.9%, respectively. Conclusion: The guided-breathing was more stable and regular than the other forms of breathing data. Therefore, the developed respiratory training system was effective in improving the temporal regularity and maintaining a more even tidal volume.

A Model of Time Dependent Design Value Engineering and Life Cycle Cost Analysis for Apartment Buildings (공동주택의 시간의존적 설계VE 및 LCC분석 모델)

  • Seo, Kwang-Jun;Choi, Mi-Ra;Shin, Nam-Soo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.6 no.6 s.28
    • /
    • pp.133-141
    • /
    • 2005
  • In the resent years, the importance of VE (value engineering) and LCC (life cycle cost) analysis for apartment building construction projects has been fully recognized. Accordingly theoretical models, guidelines, and supporting software systems were developed for the value engineering and life cycle cost analysis for construction management including large building systems. However, the level of consensus on VE and LCC analysis results is still low due to the lack of reliable data on maintenance. This paper presents time dependent LCC model based value analysis method for rational investment decision making and design alternative selection for construction of apartment building. The proposed method incorporates a time dependent LCC model and a performance evaluation technique by fuzzy logic theory to properly handle the uncertainties associated with statistics data and to analyze the value of alternatives more rationally. The presented time dependent VE and LCC analysis procedure were applied to a real world project, and this case study is discussed in the paper. The model and the procedure presented in this study can greatly contribute to design value engineering alternative selection, the estimation of the life cycle cost, and the allocation of budget for apartment building construction projects.

Changes in morphological characteristics of common mushroom fruiting bodies in different harvest flush (양송이 재배주기에 따른 형태적 특성 변화)

  • Jhune, Chang-Sung;Park, kyung-Joo;Kim, Dae-Kyeom;Oh, Youn-Lee;Park, Hye-Sung;Cho, Jae-Han
    • Journal of Mushroom
    • /
    • v.18 no.4
    • /
    • pp.297-302
    • /
    • 2020
  • Five varieties of mushrooms, including Sae-do, were examined using farm field tests to determine their morphological characteristics and quality by performing harvest flush. Considering the cultivation characteristics of the varieties studied, the parts related to mushroom generation and production showed almost similar characteristics. Overall, the mycelial forces were similar; however, in the evaluation of plantation tests performed by farmers, "saedo" was found to be the strongest and "saehan" was considered to be the weakest. Weights of fruiting bodies were related more for compost status and regimen of use than for breeding, and it was difficult to distinguish between the weights of fruiting bodies of the varieties studied. Regardless of the variety, pileus diameter, pileus thickness, and stem length of Dalseong-gun, Yongin-si, and Boryeong-si decreased as the harvest flush progressed. However, stem thickness tended to increase in the second and third flush compared to that in the first flush, regardless of the variety. However, the Gyeongju-si farms could not identify any trends attributable to varieties and harvest flushes. The pileus size and stem length of the fruiting bodies of varieties from Buyeo farms decreased with the progression of the harvest flush. However, pileus thickness and stem thickness did not show any specific tendency of growth among the varieties studied. The differences in the morphological characteristics of mushroom varieties in each harvest cycle are expected to be caused by differences in the supply of nutrients in the medium, the quality of the compost used, and the cultivation environment rather than the variety.

An Uncertainty Analysis of Calculating Life Cycle Maintenance and Energy Costs for Technical Proposals (기술제안입찰을 위한 유지관리 및 에너지 비용 산출방식의 불확실성 분석)

  • Chung, Sung Young;Kim, Sean Hay
    • Korean Journal of Construction Engineering and Management
    • /
    • v.19 no.5
    • /
    • pp.3-9
    • /
    • 2018
  • Although Life Cycle Cost (LCC) must be evaluated by experts, sometimes it may not allow a sufficient time for even the experienced LCC expert to make rational decisions. Therefore, it often ends with relatively comparing the final numbers. We have broken down 110 technical proposals that are actually bade and accepted for large construction projects, and then have analyzed the uncertainty of Maintenance and Energy (M&E) cost during building life cycle, which turns out be the most volatile factor in uncertainty of LCC. Also we suggest "Value Engineering Index (VEI)" - the reduced M&E cost that is normalized by the reduced first cost. It is analyzed that the most uncertain factors of the M&E cost include repair and replacement term differing from each project, duplicated repair and replacement, non-standard repair items, and site-specific energy cost. Eventually we propose a VEI population with a mean of 1.38 and a standard deviation of 1.19, which is obtained by individually and exclusively applying the uncertain factors of the M&E cost to the 35 standard sample of technical proposals. The LCC evaluators may be able to use the VEI population as the benchmark to select the technical proposal with the most reasonable LCC among many others in two suggested manners; the one is to deterministically calculate the probability of single VEIs, and the other is to stochastically calculate the probability of the VEIs where uncertainty is quantified.

Evaluation of Optimal Time Between Overhaul Period of the First Driving Devices for High-Speed Railway Vehicle (고속철도차량 1차 구동장치에 대한 완전분해정비의 최적 주기 평가)

  • Jung, Jin-Tae;Kim, Chul-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8700-8706
    • /
    • 2015
  • The first driving device of the power bogies for the Korean high-speed railway vehicle consists of the traction motor (TM) and the motor reduction gears unit (MRU). Although TM and MRU are the mechanically integrated structures, their time between overhauls (TBO) have two separate intervals due to different technical requirements(i.e. TBO of MRU: $1.8{\times}10^6km$, TBO of TM: $2.5{\times}10^6km$). Therefore, to reduce the unnecessary number of preventive maintenances, it is important to evaluate the optimal TBO with a viewpoint of reliability-center maintenance towards cost-effective solution. In this study, derived from the field data in maintenance, fault tree analysis and failure rate of the subsystem considering criticality of the components are evaluated respectively. To minimize the conventional total maintenance cost, the same optimal TBO of the components is derived from genetic algorithm considering target reliability and improvement factor. In this algorithm, a chromosome which comprised of each individual is the minimum preventive maintenance interval. The fitness function of the individual in generation is acquired through the formulation using an inverse number of the total maintenance cost. Whereas the lowest common multiple method produces only a four percent reduction compared to what the existing method did, the optimal TBO of them using genetic algorithm is $2.25{\times}10^6$km, which is reduced to about 14% comparing the conventional method.

Evaluation of Treatability on DOC and THMs According to Periodic Cumulative Filling of Granular Activated Carbon (GAC) (입상활성탄 주기적 누적충진에 따른 용존유기탄소와 THMs 처리능 평가)

  • Son, Hee-Jong;Kim, Sang-Goo;Seo, Chang-Dong;Yoom, Hoon-Sik;Ryu, Dong-Choon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.9
    • /
    • pp.513-518
    • /
    • 2017
  • In this paper, the removal efficiency of THMs (Trihalomethanes) and DOC (Disolved organic carbon) was compared under different GAC (Granual activated carbon) filling methods. One method is "full filling method" in which column is fully filled with GAC at once and the other is "periodic cumulative method" in which column is partially filled with GAC (10, 20, 33 and 50% of total column volume) and added each ratio during 300 days. The effluent concentration of both THMs and DOC under full filling method was low during the initial period, however, steadily increased with operating time. In the contrast, with periodic cumulative method, it maintained (relatively) evenly during the operating period. Periodic cumulative method was more efficient for removing THMs than full filling method. However, when the ratio of chlorodibromomethane or bromoform among THMs was significantly higher than chloroform and bromodichloromethane, full filling method was more efficient than periodic cumulative method. Full filling method had benefit to total DOC removal and control of average DOC concentration in effluent. Overall, periodic cumulative method is more efficient to equalize the removal efficiency of THMs and DOC, so the more frequent refilling of column with small amount of GAC is more advantageous.