• Title/Summary/Keyword: 편파관측

Search Result 92, Processing Time 0.028 seconds

Bright band detection using X-band polarimetric radar (X-밴드 이중편파 레이더에 의한 밝은 띠 탐지)

  • Lee, Dong-ryul;Jang, Bong-joo;Hwang, Seok Hwan;Noh, Hui-seong
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.12
    • /
    • pp.1211-1220
    • /
    • 2020
  • This research detects the features of the bright band (BB) through analysis of the vertical profile of range height indicator (RHI) and the slant range beam profile of plane position indicator (PPI) of the polarimetric radar measurements-horizontal reflectivity (ZH), differential reflectivity (ZDR), and cross-correlation coefficient (ρHV). As a result of the analysis, it is possible to clearly detect the bright band using the polarimetric radar measurements, and it is confirmed that the result is consistent by double searching for the BB using the RHI and PPI scan data at the same time. Based on these results, the accuracy of QPE (quantification of precipitation estimation) can be improved by applying the BB search method by the PPI slant range in this research to large rainfall radars that only scan PPI volumes in the field without RHI observations.

X밴드 이중-편파 레이더에 있어서의 강우량 산정

  • Yun, Gang-Hun
    • Magazine of the Korean Society of Hazard Mitigation
    • /
    • v.3 no.3 s.10
    • /
    • pp.23-27
    • /
    • 2003
  • 수문학자들의 주요 관심사 중 하나인 정확한 면적 강우량을 파악하는데 있어서 강우레이더는 아주 우수한 첨단 장비이다. 그러나 S 밴드나 C 밴드 레이더를 고지대에서 운영하는 것은 많은 시설비와 운영비가 필요하다. 따라서 연구 및 대도시 소유역에 대한 강우 관찰 목적으로는 차량 탑재가 가능한 소형 X 밴드 레이더가 유용할 수 있다. X 밴드 전파는 강우 도래시 전파특성상 감쇠(減衰:attenuation)가 크며, 감쇠도는 강우강도에 영향을 받는다. 이를 극복하기 위한 이중-편파 이론이 1970년대에 제시되었으나, 기술적인 어려움으로 20여년이 지난 1990년대에 실무적용이 가능하게 되었다. 현재 이중-편파 레이더의 도입으로 감쇠보정 알고리듬이 성공적으로 개발되고 있으며, 그와 같은 발상의 전환은 차등위상(differential phase)에 의한 강우 측정방법 개발로 전파 감쇠에 영향을 받지 않는 강우 관측이 가능하게 하였다. 본 기사에서는 소형 X밴드 이중-편파(偏波) 레이더의 강우량 산정방법에 대하여 간략히 검토하고자 한다.

  • PDF

Analysis on the XPD Effect in X-Band Dual-Polarization Transmission System (X-Band 이중편파 전송 시스템에서 XPD 영향 분석)

  • Park, Durk-Jong;Ahn, Sang-Il
    • Aerospace Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.211-218
    • /
    • 2007
  • Dual-polarization means to use two orthogonal polarizations, namely two independent channels in communication. This can be used to deal with high datarate caused by large amount of observed data in future LEO satellite. However, when two orthogonal polarizations are not perfectly independent to each other in practical, interference is probably raised in each channel, meaning that noise level in passband increases. XPD (Cross-Polarization Discrimination) is the ratio of the signal level at the output of a receiving antenna that is nominally co-polarized to the transmitting antenna to the output of a receiving antenna of the same gain but nominally orthogonal polarized to the transmitting antenna. In this paper, the influence of XPD on the communication between satellite and ground station was analyzed under the assumption that X-Band dual-polarization was applied to KOMPSAT-2 (KOrea Multi-Purpose SATellite-2). Through analysis, it was shown that more than 3dB of link margin was still achievable despite of worst axial ratio, 2.5dB, at ground station antenna when axial ratio of satellite antenna was about 0.5dB under 99% of environmental availability.

  • PDF

Possible Methods of Identifying Underground Cavities Using Seismic Waves (지진파를 이용한 지하 공동의 탐지 방법)

  • 김소구;마상윤;김지수
    • The Journal of Engineering Geology
    • /
    • v.6 no.3
    • /
    • pp.137-153
    • /
    • 1996
  • The purpose of this study is to investigate the possibilities of identifying and detecting underground cavities using seismic waves recorded by the fixed and mobile stations. During 18 months of field work we recorded chemical explosions near the Bongdarn station. Seismic Stations were installed on the free surface and underground inside the Samba mine. The seismograms at the fixed(lorg-term) seismic station show abrupt change of polarization characteristics which can he associated with the appearance of P-to-S converted phase(PS) at 150 ~ 200 msec after the first P arrival. This result indicates that converted phases are generated very near to the Bongdarn station at a depth of 190m. Shear-wave splitting phenomena have also been observeci The time delay between fast shear(fS) and slow shear(sS) waves ranges between 30 and 60 msec(average is 42 msec). However, exact time delay between the fast and the slow shear waves can not be accurately measured because of the very short time delay and limitation of sampling rate. Chemical explosion experiments were recorded at stations along various paths to contrast the seismic response of areas with and without cavities. The seismograms recorded at the stations installed at cavity areas show an abrupt change of polarization characteristics but not on the other stations. Seismic waves propagating through the cavity are characterized by the attenuation of high frequency waves and predominantly low frequency seismic waves after the S wave arrivals.

  • PDF

Design and Fabrication of LHCP Antenna for UHF RFID reader (UHF RFID 리더기용 LHCP 안테나 설계 및 제작)

  • Park, Sung-Il;Kim, Sun-Il;Ko, Young-Hyuk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.1
    • /
    • pp.23-30
    • /
    • 2010
  • In this paper, a design for the 900MHz bandwidth RFID reader antenna with circular polarization is proposed and experimentally investigated. The 900MHz bandwidth RFID reader antenna is proposed as a simple radiator with loading capacitor to generate LHCP(Left Hand Circular Polarization). Also, the design and fabrication of antenna has the returnloss of -32.28dB at the center frequency of 1010MHz and Bandwidth of 12.5% at 905Hz~1030MHz. Proposed LHCP antenna of maximum gain is 6dBi and satisfy axial ratio based on 2. From the measured result, axial ratios based on 2 are observed at the operating frequencies. The proposed antenna is suitable for RFID applications in wireless communications.

Removal of Super-Refraction Echoes using X-band Dual-Polarization Radar Parameters (X-밴드 이중편파 레이더 변수를 이용한 과대굴절에코 제거)

  • Seo, Eun-Kyoung;Kim, Dong Young
    • Journal of the Korean earth science society
    • /
    • v.40 no.1
    • /
    • pp.9-23
    • /
    • 2019
  • Super-refraction of radar beams tends to occur primarily under a particular vertical structure of temperature and water vapor pressure profiles. A quality control process for the removal of anomalous propagation (AP) ehcoes are required because APs are easily misidentified as precipitation echoes. For this purpose, we collected X-band polarimetric radar parameters (differential reflectivity, cross-correlation coefficient, and differential phase) only including non-precipitation echoes (super-refraction and clear-sky ground echoes) and precipitation echoes, and compared the echo types regarding the relationships among radar reflectivities, polarimetric parameters, and the membership functions. We developed a removal algorithm for the non-precipitation echoes using the texture approach for the polarimetric parameters. The presented algorithm is qualitatively validated using the S-band Jindo radar in Jeollanam-do. Our algorithm shows the successful identification and removal of AP echoes.

Measurement of Backscattering Coefficients of Rice Canopy using a Polarimetric Scatterometer System (Polarimetric Scatterometer 시스템을 이용한 벼 군락의 후방산란계수 측정)

  • Hong, Suk-Young;Hong, Jin-Young;Kim, Yi-Hyun;Oh, Yi-Sok
    • Proceedings of the KSRS Conference
    • /
    • 2007.03a
    • /
    • pp.153-157
    • /
    • 2007
  • 본 논문은 지표면 현상의 관측에 날씨의 영향을 거의 받지 않는 마이크로파 L-밴드(1.95 GHz)와 C-밴드(5.3 GHz) scatterometer 시스템을 이용하여 농업과학기술원 내의 논에서 자라는 추청벼를 대상으로 2006년 5월 29일부터 10월 9일까지 생육에 따른 군락의 후방산란계수를 관측한 데이터와 작물의 생육과의 관계를 살펴보고 또한,측정 시스템의 개요,측정 시스템의 보정 방법들을 기술하고자 한다. Scatterometer 시스템의 송 수신기로 HP 8753D 벡터 네트워크 분석기를 사용하며,타워 위에 안테나를 설치하여 3.4 m의 높이에서 측정하도록 하였다. L-밴 드와 C-밴드 scatterometer는 VV-, VH-, HV-, HH-편파를 측정하여 fully polarimetric한 데이터를 얻도록 설계된 레이더시스템으로 입사각을 $30^{\circ}{\sim}60^{\circ}$에서 $10^{\circ}$간격으로 각각 30개의 독립적인 샘플을 측정하여 통계적으로 후방산란계수를 얻었다. 타워에서 발생하는 전파 잡음과 안테나 패턴의 부엽에 의한 지면에서의 수직반사(coherent 성분) 전파를 제거하기 위해 네트워크 분석기의 time gating 기능을 사용하며,55 cm 크기의 trihedral 전파반사기를 보정용 반사기로 사용하고, STCT(single target calibration technique) 방법을 이용하여 시스템을 보정하였다. 측정 결과를 분석하여 주파수, 입사각도, 편파의 변화에 대한 벼의 후방산란 특성과 벼의 생육상태과의 관계를 살펴보았다. L-밴드와 C-밴드 모두 벼의 생육과 밀접한 결과를 나타내었으나,입사각이 작을 때는 C-밴드와의 상관이 높게 나타났고 입사각이 커질수록 L-밴드와의 상관이 높게 나타났다. 편파는 L-밴드 와 C-밴드 모두 hh 편파가,입사각은 50도에서 가장 생육의 변이를 잘 설명하는 것으로 나타났다. 생육 데이터 모두를 이용한 경우보다는 유수형성기 또는 출수기 등 벼 생육의 질적인 변화를 보이는 시기에 따라 나누어 분석하는 것이 변화추이를 더 잘 설명하는 것으로 나타났다.

  • PDF

Bright Band Detection Using X-band Polarimetric Radar (X-밴드 이중편파 레이더에 의한 밝은 띠 탐지)

  • Lee, Dong-ryul;Jang, Bong-joo;Hwang, Seok Hwan;Han, Myeong-sun;No, Huiseong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.17-17
    • /
    • 2016
  • 이중편파 레이더는 수평 수직반사도($Z_H{\cdot}Z_V$), 차등반사도($Z_{DR}$), 교차상관계수(${\rho}_{HV}$), 차등위상차(${\Phi}_{DP}$) 등 다양한 변수 산출을 통하여 대기 수상체 구분, 우적분포에 영향이 적은 강우량 추정, 밝은 띠(BB, Bright Band)의 탐지 등이 가능하게 됨으로써 수문기상 및 재해관리 분야에 활용성이 점점 더 커지고 있다. 본 연구는 RHI, PPI에서 생산된 레이더 변수를 이용하여 BB를 탐지하고 그 특성을 평가하였다. BB는 레이더를 이용하여 상층대기를 관측할 때 수직단면에서 강수입자가 눈에서 비로 변하는 구간에서 과대하게 높은 반사도가 나타나는 층을 말한다. BB에서는 QPE가 과대 추정되기 때문에, BB의 특성 파악은 레이더의 관측전략 수립과 QPE 보정에 필수적이다. 본 연구에서는 RHI에 의한 $Z_H$의 연직단면분석, RHI와 PPI의 고도각 경사거리(slant range) 빔의 ${\rho}_{HV}$, $Z_{DR}$, $Z_H$에 의한 분석을 통하여 BB의 상단부($BB_{TOP}$), 최정점($BB_{PEAK}$) 및 하단부($BB_{BOTTOM}$)의 고도를 상호 비교 평가하였다. 분석 자료는 KICT X-밴드 레이더에 의한 관측한 2015년 10월 21일의 층상운에 의한 강우를 이용하였다. RHI에 의한 $Z_H$의 연직단면 분석결과 $BB_{top}$, $BB_{bottom}$$BB_{peak}$는 KICT 레이더 고도(MSL : 40m)를 기준으로 각각 3.26Km, 2.3Km($BB_{width}$: 0.96km) 및 2.7Km로 나타났다. 이 같은 결과는 다른 2가지 분석방법에서도 유사하게 나타나고 있으며, 이는 BB분석을 위해 다양한 변수를 통한 신뢰성 있는 BB의 특성을 파악할 수 있는 기반을 제공한다.

  • PDF

Areal average rainfall estimation method using multiple elevation data of an electromagnetic wave rain gauge (전파강수계의 다중 고도각 자료를 이용한 면적 평균 강우 추정 기법)

  • Lim, Sanghun;Choi, Jeongho;Kim, Won
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.6
    • /
    • pp.417-425
    • /
    • 2020
  • In order to predict and prevent hydrological disasters such as flood, it is necessary to accurately estimate rainfall. In this paper, an areal average rainfall estimation method using multiple elevation observation data of an electromagnetic wave rain gauge is presented. The small electromagnetic rain gauge system is a very small precipitation radar that operates at K-band with dual-polarization technology for very short distance observation. The areal average rainfall estimation method is based on the assumption that the variation in rainfall over the observation range is small because the observation distance and time are very short. The proposed method has been evaluated by comparing with ground instruments such as tipping-bucket rain gauges and a Parsivel. The evaluation results show that the methodology works fairly well for the rainfall events which are shown here.

Performance Analysis of Quad-pol SAR System for Wide-Swath Operation Mode (광역관측 운용 모드에 대한 Quad-pol SAR 시스템의 성능 분석)

  • Lim, Jung-Hwan;Yoon, Seong Sik;Lee, Jae-Wook;Lee, Taek-Kyung;Ryu, Sang-Burm;Lee, Hyeon-Cheol;Lee, Sang-Gyu
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.2
    • /
    • pp.141-151
    • /
    • 2019
  • In this study, we propose a performance analysis of a quadrature-polarimetric(quad-pol) synthetic aperture radar(SAR) system for wide-swath operation mode and compare it with a single-pol system based on the operation mode. To achieve a shorter revisit time for an SAR satellite, we must observe a wide area, and two SAR operation modes exist for this purpose, which are called ScanSAR and SweepSAR. In general, a quad-pol SAR system can obtain a greater variety of information about a target than a single-pol system. Because this system affects system performance parameters, analyzing these effects is required. Based on a performance analysis of the wide-swath quad-pol SAR system, the system parameters and appropriate operation mode can be selected to satisfy the performance requirements.