• Title/Summary/Keyword: 편위

Search Result 116, Processing Time 0.023 seconds

Automated Image Alignment and Monitoring Method for Efficient Stereoscopic 3D Contents Production (스테레오스코픽 3D 콘텐츠 제작의 효율성 향상을 위한 자동 영상정렬 및 모니터링 기법)

  • Kim, Jae-In;Kim, Taejung
    • Journal of Broadcast Engineering
    • /
    • v.19 no.2
    • /
    • pp.205-214
    • /
    • 2014
  • Minimization of visual fatigue is important for production of high quality stereoscopic 3D contents. Vertical disparity of stereo images occurred during contents production is considered as the main factor of visual fatigue. To ensure correct stereoscopy vertical disparity needs to be eliminated. In this paper, a method for automated image alignment was proposed for Stereoscopic 3D contents generation and post-processing steps. The proposed method consists of two parts: rectification for image alignment and camera motion detection. The proposed method showed that its rectification performance was the most superior among the existing methods tested and that camera motion detection had a success rate of 98.35%. Through these evaluations, we confirmed that the proposed method can be effectively applied to 3D contents production.

Pulse wave Measurement System by analyzing a Moving Pulse Image in the Capillary Tube (모세관 맥동파 영상을 이용한 맥파 측정 시스템)

  • Lee, Woo-Beom;Choi, Chang-Yur;Hong, You-Sik;Lee, Sang-Suk;Nam, Dong-Hyun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.145-151
    • /
    • 2012
  • The pulsimeter is a representative device in the oriental medicine, which can analysis a risk factor in a cardiovascular diseases. However, most of the previous methods have the limit by the contacted sate of the brachial pulse and sensor in the measuring time, the inaccuracy of detected pulse, and the difficulty of pulse analysis. Accordingly, we propose the moving pulse image analysis based pulsimeter that can acquire a pulse of patient in real time by analyzing a moving image. then this video is shot the state change of the T.S. occurred by a pulse in capillary. In order to evaluate the performance of the our pulsimeter, we measured a respective detecting-rate about the essential 5 feature-points in the pulse analysis from the detected original pulse. As a result, the proposed method is very successful.

FUNCTIONAL TREATMENT OF PEDIATRIC CONDYLAR FRACTURES : A CASE REPORT (Activator를 이용한 소아의 하악과두골절의 치험례)

  • Lee, Jung-Ha;Park, Heon-Dong;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.477-482
    • /
    • 2003
  • The pediatric condylar fracture occurs very frequently in the mandible, but this injury is occasionally ignored due to difficulty of diagnosis and no cooperation of patient. The adequate initial diagnosis and active treatment must be performed because delayed and improper treatment lead to possible severe complication such as TMJ ankylosis and reta rdation of mandibular development. Most pediatric condylar fracture is mainly performed by the conservative or functional treatment, but it may be required open reduction according to cases. In this study, activator is applied for functional treatment of pediatric condylar fracture and fair recovery of jaw function is acquired.

  • PDF

Posteroanterior cephalometric study of frontal ramal inclination in chin-deviated individuals (이부편위자의 하악골상행지 경사에 관한 정모두부방사선학적 연구)

  • Eun, Chun-Sun;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.36 no.5
    • /
    • pp.380-387
    • /
    • 2006
  • Objective: The purpose of this study was to compare the right and left differences of frontal ramal inclination in chin-deviated individuals. Methods: Thirty adult patients with clinically apparent chin deviation were selected as the chin-deviated group, and 30 adult patients with symmetric faces were selected as the control group. On the posteroanterior cephalograms, the frontal ramal inclination was measured, and the right and left differences were compared and analyzed. Results: While the control group did not show right and left differences of frontal ramal inclinations, the chin-deviated individuals showed right and left differences of frontal ramal inclination. In chin-deviated individuals, the frontal ramal inclinations of the non-deviated side were statistically greater than those of the deviated side. The right and left differences of frontal ramal inclinations, with menton deviation and the right and left differences of maxillary heights showed statistically significant correlation. Conclusion: We conclude that the frontal ramal inclinations should be considered in the diagnosis of facial asymmetry.

A Study on Precision Rectification Technique of Multi-scale Satellite Images Data for Change Detection (변화탐지를 위한 인공위성영상자료의 정밀보정에 관한 연구)

  • 윤희천;이성순
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.22 no.1
    • /
    • pp.81-90
    • /
    • 2004
  • Because satellite images include geometry distortions according to photographing conditions and sensor property, and their spatial and radiational resolution and spectrum resolution are different, it is so difficult to make a precise results of analysis. For comparing more than two images, the precise geometric corrections should be preceded because it necessary to eliminate systematic errors due to basic sensor information difference and non-systematic errors due to topographical undulations. In this study, we did sensor modeling using satellite sensor information to make a basic map of change detection for artificial topography. We eliminated the systematic errors which can be occurred in photographing conditions using GCP and DEM data. The Kompsat EOC images relief could be reduced by precise rectification method. Classifying images which was used for change detections by city and forest zone, the accuracy of the matching results are increased by 10% and the positioning accuracies also increased. The result of change detection using basic map could be used for basic data fur GIS application and topographical renovation.

ACUTE AIRWAY OBSTRUCTION IN AN INFANT WITH TREACHER COLLINS SYNDROME: REPORT OF A CASE (Treacher Collins 증후군 환아에서 급성 기도 폐색)

  • Ryu, Sun-Youl;Seo, Il-Young;Hwang, Ung;Kim, Sun-Kook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.5
    • /
    • pp.422-427
    • /
    • 2004
  • Treacher Collins syndrome is inherited as an autosomal dominant trait with variable penetrance. It shows a marked variability even in the same family. This syndrome is developmental defect affecting the branchial arches. It is not usually associated with acute respiratory distress, but has symptoms of microtia, hypoplastic zygomatic bones, hypoplastic mandibular rami, and bilateral coloboma. It usually requires an emergency operation immediately after the birth. We experienced an infant with Treacher Collins syndrome who showed retrognathia, glossoptosis, microtia, and cleft palate. Intermittent cyanosis, depression of the chest, respiratory difficulty associated with airway obstruction, and swallowing difficulty were also observed. To relieve severe upper airway obstruction caused by retrognathia and glossoptosis, we simultaneously performed tongue-lip adhesion and subperiosteal release of the floor of the mouth. The respiratory and swallowing difficulties were relieved and the tongue repositioned anteriorly. We report the present case with a review of the literature.

Damped Oscill ations of the (Hard)Contact Lenses Posterior to the Blink (순목 후 콘택트(하드)렌즈의 감쇄 진동)

  • Kim, Dae-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.173-184
    • /
    • 2005
  • A capillary action-induced tension develops in the tear layer between the contact lens and cornea, which leads to the restoring force due to difference in the layer thickness between either upper and lower or left and right side of the lens when it is displaced off the equilibrium position as a result of blinking. Suppose the lens was displaced a certain distance from the equilibrium position, lens starts to oscillate toward the equilibrium position with the decreasing amplitude due to the restoring force as well as the velocity dependent viscous damping force in the tear layer. A mathematical model which consists of the differential equations and their numerical solution was proposed to analyze the damped oscillations of lenses. The model predicts the time dependence of lenses after the blink varying the various parameters such as Be, diameters, masses and positions displaced from equilibrium. As the Be and mass of lens increases the rate of amplitude reduction decreases, which requires a more time for the lens to return to the equilibrium position. It seems that varying the lens' displacement and diameters affect the lens' motion very little.

  • PDF

Improvement of Positioning Performance for GPS Module(KGP9800C) (GPS모듈(KGP9800C)의 측위성능개선)

  • 신형일;김형석;김석재;배문기;박노선
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.3
    • /
    • pp.181-189
    • /
    • 2001
  • This paper describes the positioning accuracy of GPS moduls (KGP9800C, KiRyung) which need to record the operating position of fishing boat as realtime processing in order to develope auto recording system of fishing boat's operating information, and then it's positioning accuracy for DGPS receiver (MGP-100D, Shin-A) and DGPS beacon (GP-36, Furuno) were analyzed. Futhermore, it was examined the positioning error of the GPS module with processing algorithm to minimize the effect of the signal fluctuations. The results indicate that the positioning error is able to decrease 5m as 2drms, and such improvement of positioning performance for GPS module (KGP9800C) can be provide the basic design data in the development of the auto recording system of fishing boat's operating information.

  • PDF

Accuracy of the NNSS Fix in Pusan Areas (부산지역에서의 NNSS 위치의 정도)

  • Kim, Min-Seok;Sin, Hyeong-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.1
    • /
    • pp.18-24
    • /
    • 1987
  • For the purpose of getting the accuracy of NNSS fix, the continuous observation was performed to search the factors affecting the accuracy of NNSS fix, and then to examine their effects. The observation was made at Lat. $35^{\circ}'||'&'||'<\TEX>05'04"N, Long. '||'&'||'129^{\circ}'||'&'||'<\TEX> 02'13"E from 28th January to 20th July in 1985. Accuracy of the position fixed in accordance with the observation time, each satellite, elevation angle doppler count, passed direction of each satellite and the antenna height were analyzed. The results obtaines are summerized as follows: 1. The deflaetion error is reduced to 0.21 miles when the geodetic system of the calculating the position converted from WGS-72 to Bessel. 2. When the elevation angle of the mountain is high, or the range of the elevation angle of satellite is 20-70 degrees, the position fixed comes nearest the true position. 3. The position fixed is more accurate on the condition that doppler count is more than 21, and at night than in daytime. 4. The accuracy of the position fixed is more seriously affected when the input data of the antenna height has considerable errors. But there occures almost little difference in the accuracy of position according to each satellite.

  • PDF

Reconstruction of Disharmonious Upper Anterior Dentition by Implant Supported Fixed Prosthesis (임플란트 지지 고정성 보철물로 상악 전치부를 수복한 증례)

  • Oh, Sang-Chun;Chee, Young-Deok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.183-192
    • /
    • 2008
  • Modern dental reconstructions do not only aim at restoring the patient's mastication, but rather at improving general well-being and quality of life, especially in terms of esthetics. The media, the internet, advertising, and many other facts of society contribute to an increased cosmetic awareness. A 35-year-old male patient presented with as follows: 1) the porcelain fracture of ceramo-metal restoration on #11 and #23, 2) the inclination of incisal plane to horizontal reference plane, 3) the dental midline deviation to facial midline, and 4) the lack of symmetry on upper anterior dentition. The patient requested an aesthetic improvement using fixed prosthodontics including implant-supported restorations. In the upper anterior region, one of the goals of the conventional as well as implant prosthesis is to achieve restorations with the dental attractiveness and beauty in the respect of dental, dentofacial, and facial compositions. This case report presents geometrically improvement of dental esthetics using conventional and implant prosthesis with soft and hard tissue augmentation.