Abstract

The pulsimeter is a representative device in the oriental medicine, which can analysis a risk factor in a cardiovascular diseases. However, most of the previous methods have the limit by the contacted sate of the brachial pulse and sensor in the measuring time, the inaccuracy of detected pulse, and the difficulty of pulse analysis. Accordingly, we propose the moving pulse image analysis based pulsimeter that can acquire a pulse of patient in real time by analyzing a moving image. then this video is shot the state change of the T.S. occurred by a pulse in capillary. In order to evaluate the performance of the our pulsimeter, we measured a respective detecting-rate about the essential 5 feature-points in the pulse analysis from the detected original pulse. As a result, the proposed method is very successful.

심혈관계 질환의 발병 위험요인 분석이 가능한 맥진기는 한방 의료기기에서 대표적인 연구 분야 가운데 하나이다. 그러나 기존의 대부분의 센서 기반의 맥진기는 측정시의 맥박 박동처와 센서부의 접촉상태에 따른 편위, 검출된 파형의 부정확성 및 파형분석의 어려움 등에 있어서 문제점이 발생한다. 따라서 본 논문에는 특성 센서를 사용하지 않고 단지 맥동에 의해서 유발되는 모세관 시험액의 상태 변화를 촬영한 맥동영상을 분석하여 환자의 맥파의 측정이 가능한 맥진기를 제안한다. 제안한 방법에서는 맥동영상 분석을 위한 시약영역 추출, 이진화, 수정된 열림연산, 변위측정 등의 영상처리 방법들이 적용된다. 제안한 맥진기의 성능 평가를 위해서는 추출된 압맥파로부터 맥파분석에 필수적인 5가지 주요 특징점에 대한 추출률을 측정한 결과 성공적인 결과를 보였다.

Keywords

References

  1. Chowienczyk PJ, Kelly RP, MacCallum H, etc., "Photoplethysmographic assessment of pulse wave reflection: blunted response to endothelium -dependent beta2-adrenergic vasodilation in type II diabetes mellitus", J. Am Coll. Cardiol. Vol. 34, pp. 2007-2014, 1999. https://doi.org/10.1016/S0735-1097(99)00441-6
  2. Takazawa K, Tanaka N, Fujita M, Matsuoka O, Saiki T, Aikawa M, Tamura S, Ibukiyama C., "Assessment of vasoactive agents and vascular aging by the second derivative of photoplethysmogram waveform", J. Hypertension, Vol. 32, pp. 365-370, 1998. https://doi.org/10.1161/01.HYP.32.2.365
  3. Millasseau SC, Ritter JM, Takazawa K, Chowienczyk PJ. "Contour analysis of the photoplethysmographic pulse measured at the finger", J. Hypertension, Vol. 24, pp. 1449-1456, 2006. https://doi.org/10.1097/01.hjh.0000239277.05068.87
  4. R. M. Haralick, et al., "Image analysis using mathematical morphology", IEEE Trans. on PAMI Vol. 9(4), pp. 532-550, 1987. https://doi.org/10.1109/TPAMI.1987.4767941
  5. Intel. Open source computer vision library: Reference manual. 2001.
  6. Wilkinson, Ian B., Fuchs, Sabine A. et al., "Reproducibility of pulse wave velocity and augmentation index measured by pulse wave analysis", J. Hypertension, Vol. 16(12), pp. 2079-2084, 1998. https://doi.org/10.1097/00004872-199816121-00033
  7. Rafael G. Gonzalez, Digital Image Processing 3/e , Prentice Hall, 2007.
  8. M. Sonka, et al., Image Processing, Analysis, and Machine Vision 2th, PWS, 1999.
  9. D. Marr, Vision: A computational investigation into the human representation and processing of visual information. W. H. Freedom & Company, 1982.
  10. WB Lee, CY Choi, YS Hong, SS Lee, DH Nam, "Pulsimeter Design by analyzing a moving pulse image", Spring KoCon COnference Vol.9(1), pp. 13-14, 2011.
  11. L. Fausett, Fundamentals of Neural Networks : Architecture, Algorithms, and Applications, Prentice-Hall Inc., 1994.

Cited by

  1. Development of pulse diagnostic devices in Korea vol.2, pp.1, 2013, https://doi.org/10.1016/j.imr.2013.01.003