Operating Characteristics of Low Vacuum Pumps (저진공 펌프의 운전 특성)

  • 임종연;심우건;정광화
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.2
    • /
    • pp.93-104
    • /
    • 2003
  • For evaluation of durability of low vacuum pumps, it is required to examine the performance and degradation of low vacuum pumps. Pump degradation may result from abnormalities associated with the performance in many areas of pump operation. The diagnostics method can be used to monitor the pump performance in the semi-conductor process line. Based on the mechanical defect of the pump, the dynamic response and reliability of the system for performance test, and the dynamic characteristics of the pump were experimentally assessed. The theoretical work rate for the compression process in the pump was calculated, and then the efficiency of the pump associated with the power consumption was evaluated. This analysis will be useful in detecting pump degradation with increasing the power consumption. To determine the predominant factors of pump degradation, it is important to evaluate the entire pumping system. We studied vibration, dynamic pressure, pumping speed, and power consumption of low vacuum pumps. Our results can be utilized for the future research on the evaluating technology of durability of low vacuum pumps.

Investigation on the Performance Characteristics of the 75ton Class Turbopump Turbine (75톤급 액체로켓 엔진 터보펌프 터빈의 성능특성연구)

  • Jeong, Eun-Hwan;Lee, Hang-Gee;Park, Pyun-Goo;Kwak, Hyun-D.;Kim, Jin-Han
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.5
    • /
    • pp.65-71
    • /
    • 2010
  • Performance test of the 75ton class turbopump turbine was performed. Using the measured turbine power characteristics in the wide-range operational conditions, variations of nozzle velocity ratio, total pressure loss, and relative flow angle to the pressure ratios and rotational speeds are quantified. Efficiency and nozzle exit pressure behavior was also investigated and compared with 30ton turbopump turbine data. A rotor blade was redesigned based on the test results and CFD analysis.

Investigation on the Performance Characteristics of the 75ton Class Turbopump Turbine (75톤급 액체로켓 엔진 터보펌프 터빈의 성능특성연구)

  • Jeong, Eun-Hwan;Lee, Hang-Gee;Park, Pyun-Goo;Kim, Jin-Han
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.38-44
    • /
    • 2010
  • Performance test of the 75ton class turbopump turbine was performed. Through the turbine power measurement in the wide-range operational conditions, velocity ratio, total pressure loss, and relative flow angle characteristics was quantified. Efficiency and nozzle exit pressure behavior was also investigated and compared with 30ton turbopump turbine data. A rotor blade was redesigned based on the test results and CFD analysis.

  • PDF

Capacity Modulation of a Ground Source Multi-Heat Pump in the Part Load Condtions (축열형 지열원 냉난방 시스템의 단기 성능 특성 연구)

  • Kim, Namtae;Cho, Chanyong;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.119-119
    • /
    • 2010
  • 무한 지속 가능한 지열 에너지를 활용한 공조시스템인 지열원 냉난방 시스템은 기존의 공조 시스템보다 열원이 안정적이기 때문에 높은 효율과 우수한 성능을 가지므로, 기후변화협약 대응의 주요수단으로서 기술개발과 보급이 증대되고 있다. 본 연구에서는 대수층 축열 지열원 열펌프 시스템에 대한 실증 연구를 통하여 대수층 축열 지열원 열펌프 시스템의 하절기 냉방 성능을 분석하였다. 대수층 축열 냉난방 시스템은 주입정과 양수정의 2개의 우물공이 설치되어 있으며, 겨울 난방 운전 중에 한 개의 우물공으로부터 지하수를 열펌프로 유입한 후 낮은 온도의 지하수를 타 우물공에 축열하고, 하절기에 겨울에 저온으로 축열된 우물공으로부터 지하수를 열펌프로 유입하여 온도가 증가된 지하수를 타 우물공에 주입한다. 즉, 계절별로 열펌프에서 생성된 냉수와 온수의 대수층 축열을 위하여 계절별로 주입정과 양수정이 바뀌게 된다. 본 연구의 대수층 축열 지열원 열펌프 시스템의 2009년 8월의 주요일자별 시스템 운전 중의 평균 냉방 열펌프 유닛 COP와 냉방 시스템 COP는 각각 4.7과 3.4이상의 우수한 성능을 나타냈다. 또한, 모든 일자에 대하여 외기온도가 $31.6^{\circ}C$$22^{\circ}C$까지 변화가 크게 나타났지만 열펌프 유닛 COP와 시스템 COP의 변화는 미소하였다. 이는 양수정으로부터의 지중 순환수가 운전기간 중에 $17.5^{\circ}C$로 일정하게 유지되었기 때문이다. 양수정과 주입정 사이에 5개의 관측공을 설치하였으며, 양수정 측에 인접한 관측공의 온도는 거의 변화가 없었으며, 단기간이지만 널리 사용되고 있는 수직밀폐형 시스템과 달리 지속적인 냉방운전 중의 양수 온도의 증가는 발생하지 않아 안정적인 성능을 나타냈다. 주입정에 인접한 모니터링 홀의 온도는 심도가 깊은 곳의 온도가 낮은 곳보다 높게 나타났다. 이는 냉방 운전 시 열펌프 유닛의 실외열교환기에서 지중 순환수가 냉매로부터 열을 취득하여 온도가 상승하면서 주입정측에 온열이 축열이 진행되었기 때문으로 분석되며, 하절기의 냉방 운전 시간이 증가할 경우 축열 효과는 더욱 증가할 것으로 예상된다. 양수정과 주입정 중간의 모니터링 홀의 온도는 2009년 8월 가동 중에 온도변화는 없었는데, 이는 양수정과 주입정 사이의 열간섭이 발생하지 않았기 때문으로 분석된다. 일자별로 운전 중의 열펌프 유닛 COP는 차이가 없었지만, 운전 및 정지 시간을 모두 포함한 시스템 소비전력과 냉방용량을 모두 합산하여 산정한 일일 평균 냉방 열펌프 유닛 COP와 냉방 시스템 COP는 일자별로 다소 차이가 발생하였는데, 이는 각 일자별로 열펌프 유닛 가동율의 차이로 인하여 열펌프 유닛 가동 전에 먼저 작동되는 지중순환펌프의 운전 소비전력의 차이와 열펌프의 단속운전 시의 열손실과 추거 소비전력의 차이 때문이다.

  • PDF

간접 가열하는 게터펌프의 배기 특성

  • Park, Jong-Do
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.154.2-154.2
    • /
    • 2014
  • 작은 동전 모양의 게터를 사용하여 간단한 초고진공용 펌프를 제작하여 그 특성을 알아보았다. 이 게터는 대기 측에서 진공용기를 가열하여 금속 열전도를 통하여 활성화되도록 하였으며 상용 게터펌프(또는 이온펌프와의 조합)와도 그 진공성능을 비교하여 보았다. $350^{\circ}C$에서 24시간 활성화 한 후 수소의 배기속도는 약 200 l/s였으며 CO의 배기속도는 매우 낮았다. 그러나 최고 도달진공도는 ~2E-11 mbar로 상용 조합펌프와 견줄 만하였다. 이 실험 결과로부터 간접가열방식으로 적용 가능한 최대 활성화 온도에서 네그펌프가 안전히 활성화 되지 않음을 알 수 있었다. 그러나 네그펌프의 자체 기체방출이 매우 작아서 수소를 주로 배기하는 초고진공, 극고진공에서는 응용 가능할 것으로 보인다.

  • PDF

Air-liquid Flow Characteristics of Riser of Air-lift Pump (공기양수펌프 Riser 내의 기액유동특성)

  • Lee, Cheol-Hee;Cho, Dae-Hwan;Choi, Ju-Yeol;Park, Chan-Soo
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.11a
    • /
    • pp.239-244
    • /
    • 2006
  • As an effective means to convey crushed materials from seabed to onboard ship, air-lift pump provides a reliable mechanism due to its simple configuration and easy-to-operate principle. The present study is focused on fundamental investigation of related performance through analysis program based on the gas-liquid two-phase flow in circular pipes. It is summarized as important result that an optimum air mass flow rate exists for the maximum lifted liquid mass flow rate in terms of a given submergence rates.

  • PDF

Prediction of GHP Performance Using Cycle Analysis (사이클 해석을 통한 GHP 성능 예측)

  • Cha, Woo Ho;Choi, Song;Chung, Baik Young;Kim, Byung Soon;Jeon, Si Moon
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.1
    • /
    • pp.15-21
    • /
    • 2015
  • In this paper a prediction method of GHP performance is proposed for increasing design accuracy. Two compressors with different capacity and 2311cc gas engine are used for prediction and the target capacity of GHP is 25HP. For predicting GHP performance at first the operation points are randomly selected and then as compared with compressor performance date and heat exchanger characteristic, more accurate operating points are decided through recursive calculation. Lastly engine performance date is used for calculating gas consumption volume. Predicting heating mode performance of GHP, evaporator is separated to the two section of absorbing heat in outdoor air and in engine. From the experimental results, it was found that the simulation model is good for the predicting GHP efficiency and the difference of predicted and measured efficiency is less than 5%.

TMP 1000L/s 급 database 구축 및 종합특성평가시스템 진단 기술 개발

  • Gang, Sang-Baek;Sin, Jin-Hyeon;Cha, Deok-Jun;Jeong, Wan-Seop;Im, Jong-Yeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.335-335
    • /
    • 2010
  • 한국표준과학연구원 진공센터에서는 국제규격에 바탕을 둔 저진공펌프 종합특성평가시스템을 구축하여 $1100mbar\;{\sim}\;10^{-3}mbar$ 압력 영역에서의 저진공펌프(roots, dry 등)류의 종합특성평가를 시행하고 있다. 저진공펌프 종합특성평가시스템은 국제적 절차에 따른 신뢰성을 바탕으로 구축하고 있으나, 한국표준과학연구원 진공센터 뿐만 아니라, 국내에서도 고진공 종합특성평가 시스템을 구축 하고 있지 않다. 이에 반도체/디스플레이 등 첨단 공정에서 진공 환경을 조성하는 핵심장비인 고진공펌프의 종합특성평가시스템을 개발하고자 터보펌프(TMP) 1000L/s 급의 database를 구축 하였다. 터보펌프(TMP)는 throughput method와 orifice method 두 가지 방법을 병행하여 pumping speed 측정한다. orifice method는 일종의 미세유량 측정 장치이며, 실험값과 계산값 유량의 오차 범위가 작고 신뢰성을 확보하면 throughput method 만으로 측정할 수 있다. Througput method는 $10^{-6}mbar$ 압력 이상의 영역을 측정하며, ultimate pressure 및 $150^{\circ}C$의 bake-out 을 진행하여 base pressure을 측정 할 수 있으며, $10^{-6}mbar$ 압력 이상의 pumping speed를 측정 할 수 있다. 이에 따른 정압형 유량시스템을 개발 중에 있으며, inlet pressure와 outlet pressure를 이용한 compression ratio를 측정 한다. Orifice method는 ultimate pressure와 base pressure을 측정하며, leak valve를 이용한 컨덕턴스(C)로 pressure ratio을 이용하여 유량값을 계산하며, $10^{-6}mbar$ 압력 이하의 pumping speed를 측정할 수 있다. 또한 throughput method와 orifice method의 pumping speed 뿐만 아니라 소비전력 및 소음, 진동, 온도 등 특성평가 관련 사항들의 전반적인 사항을 평가하여 터보펌프(TMP) 1000L/s 급의 database를 구축한다. 향후 예비 실험을 통한 고진공펌프의 종합특성평가시스템을 완비해 나가며, 고진공펌프 종합 특성평가시스템을 통하여 국제적으로 공인받을 수 있는 평가기준을 확립하고 그 기준에 의한 진공/기계적 성능의 전방위적인 종합특성진단과 공정대응성 평가 등 국제적 기술 신뢰성을 확보하고자 한다.

  • PDF

Analysis Study of Seasonal Performance Factor for Residential Building Integrated Heat Pump System (주거용 건물에서의 히트펌프 시스템 연성능 평가에 관한 연구)

  • Kang, Eun-Chul;Min, Kyoung-Chon;Lee, Kwang-Seob;Lee, Euy-Joon
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.1
    • /
    • pp.3-10
    • /
    • 2016
  • Heat pump unit performance is represented by the COP(Coefficient of Performance) and expressed by the one point design condition according to KS C 9306. However, when heat pump operated to the real buildings, the simulations are changed continuously according to the actual weather conditions, the building load and heat pump source conditions. The purpose of this paper is to evaluate the APF(Annual performance factor) for a climate dependent building integrated air-to-air heat pump system in major cities in Korea. TRNSYS simulation tool with an international MV standard based IPMVP 4.4.2 was utilized to perform the annual performance analysis. The APF with the multi-performance data based method was calculated as 2.29 for Daejeon residential building case while Busan residential building case appeared as the highest with 2.36.

고진공펌프 종합특성평가 기술개발

  • Im, Jong-Yeon;In, Sang-Yeol;Im, Seong-Gyu;Jeong, Wan-Seop;Baek, Gyeong-Min;Choe, Gyeong-Min;Nam, Seung-Hwan;Hong, Seung-Su;Go, Deuk-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.112.2-112.2
    • /
    • 2013
  • 지식경제부의 청정제조기반 산업원천개발사업의 일환으로 진행 중인 "초고진공펌프 개발" 과제 중 제 3세부 과제인 "고진공펌프종합특성평가시스템 설계, 진단기술 개발" 과제에서 5년 동안 진행되고 있는 전반적인 연구수행결과 및 구축 완료된 종합특성평가시스템을 활용한 고진공펌프의 상용화를 위한 신뢰성 평가에 관하여 소개한다. 고진공펌프개발 총괄 과제의 대명제는 "국제적 신뢰성을 가지는 상용화 제품의 완성"이며, 10(3) mbar~10(-10) mbar 영역의 국내 진공펌프 개발 수준의 선진화를 위한 모든 특성평가장치의 국제적 신뢰성이 있는 완벽한 성능평가의 구현을 포함한다고 볼 수 있으며, 전체 사업 추진기간 동안 제품 개발 주체인 산업체에 상용화를 위한 신뢰성 기반기술의 완벽한 구현의 제공에 있다고 할 수 있다. 이러한 고진공펌프의 신뢰성 평가는 저진공펌프의 신뢰성 평가기술에 기반을 두고 있으며, 기 개발 완료된 특성평가뿐만 아니라 실질적으로 나노종합팹센터의 공정현장에서 판단할 수 있는 내구성진단 및 최종 제품의 기계적 신뢰성 진단기술의 복합적인 요인들의 집합적인 분석에 기인하고 있다고 판단할 수 있다. 상용화 단계의 내구성 및 신뢰성 확보를 위한 전제 조건은 대외적으로 공표할 수 있는 시험평가 데이터와 개발 주체에서 기밀 수준으로 유지해야만 하는 민감한 자료의 상시 생산 infra의 구축으로 볼 수 있다. 이러한 진공펌프개발이라는 과제의 대명제를 완성하기 위한 연구개발 등 최종 상용화에 필요한 국제 신뢰성, 공정대응성 확보 기술개발 등 핵심사업 추진내용을 소개하고자 한다.

  • PDF