• Title/Summary/Keyword: 펌프 설계

Search Result 1,007, Processing Time 0.029 seconds

Development of Optimum Design Method for Geothermal Performance based on Energy Simulation (지열 성능해석 시뮬레이션에 기반한 최적 설계 수법 개발)

  • Moon, Hyeongjin;Kim, Hongkyo;Nam, Yujin
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.3
    • /
    • pp.43-48
    • /
    • 2019
  • Since the revision of the Rationalization of Energy Use Law, the spread of new and renewable energy in buildings has been promoted. In addition, the production of electric power and thermal energy is an important issue in the change of energy paradigm centered on the use of distributed energy. Among them, geothermal energy is attracting attention as a high-performance energy-saving technology capable of coping with heating / cooling and hot water load by utilizing the constant temperature zone of the earth. However, there is a disadvantage that the initial investment cost is high as a method of calculating the capacity of a geothermal facility by calculating the maximum load. The disadvantages of these disadvantages are that the geothermal energy supply is getting stagnant and the design of the geothermal system needs to be supplemented. In this study, optimization design of geothermal system was carried out using optimization tool. As a result of the optimization, the ground heat exchanger decreased by 30.8%, the capacity of the heat pump decreased by 7.7%, and the capacity of the heat storage tank decreased by about 40%. The simulation was performed by applying the optimized value to the program and confirmed that it corresponds to the load of the building. We also confirmed that all of the constraints used in the optimization design were satisfied. The initial investment cost of the optimized geothermal system is about 18.6% lower than the initial investment cost.

A low noise PLL with frequency voltage converter and loop filter voltage detector (주파수 전압 변환기와 루프 필터 전압 변환기를 이용한 저잡음 위상고정루프)

  • Choi, Hyek-Hwan
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.1
    • /
    • pp.37-42
    • /
    • 2021
  • This paper presents a jitter and phase noise characteristic improved phase-locked loop (PLL) with loop filter voltage detector(LFVD) and frequency voltage converter(FVC). Loop filter output voltage variation is determined through a circuit made of resistor and capacitor. The output signal of a small RC time constant circuit is almost the same as to loop filter output voltage. The output signal of a large RC time constant circuit is the average value of loop filter output voltage and becomes a reference voltage to the added LFVD. The LFVD output controls the current magnitude of sub-charge pump. When the loop filter output voltage increases, LFVD decreases the loop filter output voltage. When the loop filter output voltage decreases, LFVD increases the loop filter output voltage. In addition, FVC also improves the phase noise characteristic by reducing the loop filter output voltage variation. The proposed PLL with LFVD and FVC is designed in a 0.18um CMOS process with 1.8V power voltage. Simulation results show 0.854ps jitter and 30㎲ locking time.

An analysis on the drop impact simulation of dual pump cap container made of eco-friendly materials (친환경 소재로 형성된 듀얼 펌프캡 용기의 낙하충격 시뮬레이션 분석)

  • Wi, Eun-Chan;Ko, Min-Sung;Kim, Hyun-Jeong;Lee, Joong-Bae;Kim, Min-Su;Lee, Joo-Hyung;Kong, Jung-Shik;Baek, Seung-Yub
    • Design & Manufacturing
    • /
    • v.15 no.1
    • /
    • pp.57-65
    • /
    • 2021
  • Pump cap is a product that is widely used due to its ease of use and simple operation. These pump caps are applied to heterogeneous functional cosmetics and are being developed as dual pump caps. However, the conventional dual pump cap has a problem in that it is inconvenient to use and leakage occurs. In addition, it is formed of a plurality of materials, and there is a problem that is difficult to recycle. Lately, since the problem of environmental pollution is getting serious, the dual pump cap, which is difficult to recycle, cannot be used. Currently, eco-friendliness has been considered in Korea, and there are no dual pump cap containers with excellent sealing performance. Therefore, in this study, a dual pump cap container made of eco-friendly material was designed. In addition, finite element analysis was performed to verify the design feasibility of the product.

Temperature Variation of Exhaust Gas in Diesel Generator for Low Pressure SCR (저압 SCR을 위한 디젤발전기 배기가스 온도 변화)

  • Hong, Chul Hyun;Lee, Chang Min;Lee, Sang Duk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.2
    • /
    • pp.355-362
    • /
    • 2021
  • To facilitate low-pressure selective catalyst reduction (L.P SCR), a high exhaust-gas temperature of a four-stroke diesel engine for a ship's generator is required. This study aimed at reducing the exhaust-gas temperature by adjusting the valve open-close timing and fuel injection timing to satisfy the operating conditions of L.P SCR and prevent accidents associated with the generator engine due to high temperature. To lower exhaust-gas temperature, the angle of the camshaft was adjusted and the shim of the fuel injection pump was added. As a result, the maximum explosion pressure increased and the average of the turbocharger outlet temperature dropped. Considering the heat loss from the turbocharger outlet to the SCR inlet, the operation condition for L.P SCR was satisfied with 290 ℃. The study demonstrates that safe operation of a diesel generator can be achieved by lowering the exhaust-gas temperature.

Evaluation and Analysis on the Effects of Flood Damage Mitigation according to Installation on Deep Underground Rainwater Tunnel (대규모 터널형 빗물저류배수시설 설치에 따른 침수피해저감 효과 평가 및 분석)

  • Myung Hoon Lee;Jun Han Bae;Jun Bae Hong;Soo Jin Moon;Ji Hyeok Choi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.365-365
    • /
    • 2023
  • 우리나라는 지리, 지형 및 기상특성으로 인해 집중호우와 태풍 등으로 자연재해 피해를 입고 있으며, 재해예방사업의 일환으로 1998년부터 자연재해위험개선지구 정비사업을 통해 자연재해로부터 침수, 유실, 붕괴위험 등 피해예방을 위해 노력하고 있다. 서울특별시는 도시화로 인한 우수침투 가능지역 감소와 유역경사 부족에 따른 충분한 관거 경사확보의 어려움으로 저지대에 노면수가 집중되면서 대규모 침수피해(2010. 09, 2011. 07)가 발생되었으며, 신월·신정지구 및 화곡2지구가 자연재해위험개선지구로 선정(2011. 04), 침수방지를 위한 대책으로 국내 최초의 대규모 터널형 빗물저류배수시설(신월빗물저류배수시설)을 준공(2020. 05)하였다. 본 연구에서는 신월빗물저류배수시설 설치에 따른 상습침수구역의 사업 전·후 침수피해 저감효과 검증을 위해 도시유출모형을 구축하여 서울시 방재성능목표 확보여부를 판단하고자 하였다. 기존 설계 당시 서울시 방재성능목표(30년 빈도, 95mm/hr)는 확보되었으나 이를 초과하는 강우(2010. 09, 98.5mm/hr)가 발생함에 따라 수행된 추가 분석(100mm/hr) 결과, 유역의 침수 완전해소를 위해서는 빗물저류배수시설과 더불어 국부적인 간선관거 개량의 필요성이 제시되었다. 이에 따라 본 연구에서는 도시유출모형 구축 시 최근 개선된 하수관로, 지형특성, 홍수량산정표준침(2019, 환경부)등에 따른 수리·수문특성을 반영하고, 신일펌프장(간이)을 추가적으로 고려하여 현재 기준에서의 침수피해 저감 효과를 면밀이 분석하였으며, 그 결과 서울시 방재성능목표 뿐만 아니라 100mm/hr에도 침수가 완전 해소되는 것으로 나타났다. 신월빗물저류배수터널 설치에 따른 침수피해 저감효과 평가 및 분석결과를 통해 자연재해위험개선지구의 해제가 가능할 것으로 판단되며, 지역안전·환경효과, 주민만족도 등 다양한 항목에 대하여 상습침수구역 내 주민설문조사를 수행한 결과 신월빗물저류배수터널에 대한 만족도가 충분히 제고된 만큼 향후 시설의 기능적, 운영적 측면에서의 유지관리가 잘 이루어진다면 침수로부터 안전한 도시를 구현하는데 큰 역할을 할 것으로 기대된다.

  • PDF

Development of an outline project cost calculation module for disaster prevention facilities in the living area due to winds and floods (풍수해 생활권 방재시설에 대한 개략 사업비 산정 모듈 개발)

  • Kim, Sol;Lee, Dong Seop;Lee, Jong Jin
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.1
    • /
    • pp.45-52
    • /
    • 2023
  • Due to natural disasters such as heavy rain that occurred in the metropolitan area in August 2022, human casualties and property damage are increasing. Accordingly, the government is making efforts to respond to natural disasters, but due to the absence of related standards and standardized standards, problems such as increased construction costs and deterioration in construction quality for disaster prevention facility maintenance projects are occurring. Accordingly, a rough construction cost estimation module was developed and applied to 25 new pumping stations in Korea. As a result of the analysis, the accuracy of the rough construction cost derived through the module recorded 70% of the detailed design cost, which is 4% higher than the previously used rough construction cost accuracy of 66% by the Ministry of Environment. Accordingly, it is expected that the efficiency of the disaster prevention project can be increased if the developed module is used to calculate the rough construction cost for storm and flood disaster prevention in the future.

Flood Risk Assessment of Seoul based on Watershed Characteristics (유역특성 기반의 서울시 침수위험성 분석)

  • Kim, Sung Eun;Kang, Won-Sam;Baek, Jong-Rak
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.38-38
    • /
    • 2022
  • 서울특별시(이하 서울시)는 기존 상습침수지역과 2010년, 2011년 집중호우로 발생한 침수피해를 바탕으로 34개의 침수취약지역을 선정하고, 이들 지역에 2011년 3월부터 2023년 12월까지 총사업비 1조 5,300억여 원을 투입하여 하수관거 정비, 펌프장 신설 및 증설, 저류조 신설 등 배수능력을 확충하는 사업을 진행해오고 있다. 하지만, 기후변화로 인해 집중형 배수시설의 설계용량을 초과하는 강우의 발생빈도가 증가하고, 극한홍수 발생위험과 기상예측 불확실성이 커짐에 따라, 배수시설의 용량을 증설하는 집중형 우수배제체계 중심의 침수관리만으로는 안전한 침수대응이 어렵게 되었다. 본 연구에서는 서울시 침수대응 다각화를 위해 유역의 자연적, 사회환경적 특성을 대표할 수 있는 52개 지표를 선정하고 서울시를 소규모 유역 단위인 163개의 배수분구로 구분하여 지표별 공간적 분포와 특성 분석을 통해 각 배수분구를 유형화하고, 유형특성에 따른 침수취약성과 잠재적 침수발생 위험성을 분석하여 침수위험성을 평가하였다. 유역의 특성을 대표하는 각종 지표의 서울시 내 공간적 분포를 분석한 결과, 지표별 공간적 분포 특성이 상이했으며, 지표별 최대/최소값의 차이가 수배에서 수백배까지 나타나는 것으로 분석되었다. 특히, 서울시 내외에 산포된 총 40개 기상청관측소의 2010년부터 2019년까지 시간강우자료를 이용하여 강우관련 지표들의 시공간적 분포를 분석한 결과, 연평균강우량, 여름철강우량, 일최대강우량 등에서 지역적으로 최대 수백 mm의 강우량 차이가 발생하는 것으로 나타났다. 유역특성에 따른 서울시 침수위험성을 평가한 결과, 침수발생 및 피해에 불리한 유역의 공간적 취약성이 높은 배수분구로는 봉천1, 송파, 길동, 미아, 상계1 등의 순으로 나타났으며, 침수발생에 대한 잠재적 위험성이 높은 배수분구는 이문, 정릉, 제기1, 장안, 전농 등의 순으로 분석되었다. 침수발생에 대한 잠재적 위험성과 침수피해에 불리한 공간적 취약성이 모두 높아 침수위험성이 큰 배수분구는 상계1, 미아, 장위, 창동1, 동선, 수유2, 방학, 길동, 월계2 등의 순으로 나타났다.

  • PDF

A study on the simulation of flooding in Top-down construction site considering extreme rainfall (극한강우를 고려한 Top-down 현장 침수모의에 관한 연구)

  • Im, JangHyuk;Cho, HyeRin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.30-30
    • /
    • 2022
  • 최근 기후변화로 인한 국지성 호우 빈도 및 강수량이 급증하는 등 극한강우 발생 가능성이 높아지고 있는 실정이다. 공공 기반의 유역 및 지자체별 침수 대응은 지속적으로 이루어지고 있으나, 건설 현장 대응은 이에 비해 미흡한 실정이다. 특히, 건설 현장의 경우, 예측할 수 없는 홍수 유출에 대해서도 기존 설계시 반영된 홍수 유출량과 기상청 정보에만 의존하고 있어 극한강우 발생시 취약성을 나타낼 수 있다. 특히, Top-down 현장은 개구부, 표면 작업을 위한 포장 등에 의해 지하부로 유입되는 강우량이 많고, 지하 굴착공사시 단차 및 지하수 발생으로 극한강우시 침수에 의한 수재해 발생 확률이 높다. 이를 대비하기 위해 XP-SWMM 모형을 이용하여 지상부와 지하부의 강우-유출량을 산정하고 지하부 침수를 모의하였다. 실제 Top-down 현장조사를 통해 침수 관련 인자와 XP-SWMM을 연계하여 침수모의 기법에 적용하였다. 관련 주요인자는 강우량, 현장 지상부 면적, 지상부 배수로, 지하 유입부, 지하 배수펌프 등으로 현장 조사결과 나타났다. 강우자료의 경우, 극한강우를 고려하기 위해 현장 지역의 최대 강우량, 태풍 루사와 기상청 강우의 증가 시나리오를 고려하여 모의에 적용하였다. 본 연구에서는 극한강우에 대한 Top-down 침수 모의를 수행할 수 있는 상용 모델링과 이와연관된 인자를 도출하여 침수 모의 기법을 최적화 하였다. 이러한 침수 모의를 통해 Top-Down 현장 침수심 등을 예측할 수 있다. 향후 이를 통해 지하공간이 있는 건설현장의 강우-유출 현상및 침수 모의가 가능하고, 실시간 현장별 침수 예측 모델 개발로 현장별 대피경로 및 대응방안을 제시하여 인적 피해를 최소화할 수 있을 것으로 기대할 수 있다.

  • PDF

A Study on the installation of Optimal Stormwater Reservoir based on Grid units and the application of LID Facilities. (격자단위 기반의 최적 우수저류지 설치 및 LID 시설물 적용 연구)

  • Uugantsetseg, Gankhuyag;Choi, Gyung Min;Lee, Jung Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.343-343
    • /
    • 2022
  • 강우의 유출은 하늘에서 발생한 강우가 다양한 유역을 거쳐 하천 및 해안 등으로 방류되는 일련의 과정을 의미한다. 강우의 유출과정에서 좀 더 효율적인 유량처리를 위하여 대부분의 도시 유역에는 우수관망이 설치되어 있다. 우수관망은 일정 빈도 이하의 강우량 방재를 목적으로 설계하며, 해당 강우량을 초과하는 경우 침수피해가 발생한다. 우수관망의 목표 강우를 초과하는 경우를 위하여 우수 저류지, 펌프장 및 LID(Low Impact Development) 시설물 설치 등 다양한 노력이 지속되어 왔으며, 이를 더욱 효율적으로 관리하기 위한 연구가 지속되고 있다. 본 연구에서는 강우 발생유역을 격자로 분할하여 우수의 흐름을 파악하여 효율적인 저류지 및 LID 시설물의 설치 위치를 지정하고자 한다. 분석지역은 경상남도 창원시 마산합포구 인근이며, ArcGIS 10.8을 이용하여 해당 지역의 지형을 3D로 구현하였으며 EPA-SWMM 5.1을 이용하여 침수분석을 진행하였다. 또한, 구성된 TIN(Triangulated Irregular Network)를 10m × 10m 크기의 격자로 분할하여 지표고에 따른 유량의 흐름 및 중첩을 판단하였다. 분할된 격자들 중 유량의 중첩 정도가 가장 높으며 침수피해 정도가 높은 지역을 대상으로 종류 및 크기를 고려한 최적의 비용과 효율을 갖는 저류지 및 LID 시설물 설치 위치를 결정하였다. 우수관망 시스템, LID 시설물, 우수 저류지 각각의 시선에서 접근한 기존의 연구와 달리 다양하고 포괄적인 방재시설물 설치를 통해 더욱 효율적이고 경제적인 우수 방재 시스템 구현에 도움이 될 것으로 기대된다. 우수관망 시스템, LID 시설물, 우수 저류지 각각의 시선에서 접근한 기존의 연구와 달리 다양하고 포괄적인 방재시설물 설치를 통해 더욱 효율적이고 경제적인 우수 방재 시스템 구현에 도움이 될 것으로 기대된다.

  • PDF

Design and Fabrication of Sputter Coating System for Ophthalmic Lens (안경렌즈코팅용 소형 Sputter Coating System 설계 및 제작에 관한 연구)

  • Park, Moonchan;Jung, Boo Young;Kim, Eung Sun;Lee, Jong Geun;Joo, Kyung Bok;Moon, Hee Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.53-58
    • /
    • 2008
  • Purpose: To design and fabricate the small sputter coating system for the Ophthalmic lens. Methods: The design of sputter target was done using macleod program for AR coating and mirror coating of Ophthalmic lens with Si target and then the sputter system was fabricated. Results: The optimum condition of AR coating with Si target was [air|$SiO_2$(81.3)|$Si_3N_4$ (102)|$SiO_2$(19.21)|$Si_3N_4$(15.95)|$SiO_2$(102)|glass], for blue color mirror coating [air|$SiO_2$(56.61)|$Si_3N_4$(135.86)|$SiO_2$(67.64)|$Si_3N_4$(55.4)|$SiO_2$(53.53)|$Si_3N_4$(51.28)|glass], for green color coating [air|$SiO_2$(66.2)|$Si_3N_4$(22.76)|$SiO_2$(56.58)|$Si_3N_4$(140.35)|$SiO_2$(152.35)|$Si_3N_4$(70.16)|$SiO_2$(121.87)|glass], for gold color [air|$SiO_2$(83.59)|$Si_3N_4$(144.86)|$SiO_2$(11.82)|$Si_3N_4$(129.93)|$SiO_2$(90.01)|$Si_3N_4$(88.37)|glass]. Conclusions: In the fabrication of sputtering coating apparatus, Dual cathode with same Ti target were coated at the same time on both sides of Ophthalmic lens to lessen the time of coating on Ophthalmic Lens and save the cost of the lens. The distance of target-substrate of cathode was variable from 12.5 cm to 20 cm. Turbo pump was used to take the whole coating process about 15 min. instead of diffusion pump. The lens holder was made to coat 2 pairs lens every coating and was rotated to get the uniformity of thin film.

  • PDF