• Title/Summary/Keyword: 펌프압송

Search Result 36, Processing Time 0.029 seconds

An Experimental Study on Pumpability Characteristics of High Strength Concrete Mixed Polymix (폴리믹스 혼입 고강도 콘크리트의 펌프압송 성상에 관한 실험적 연구)

  • Lee, Joo-Ho;Moon, Hyung-Jae;Kim, Jeong-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.5
    • /
    • pp.509-516
    • /
    • 2012
  • The aims of this research is to develop a fire resistant admixture to enhance high-pressured pumping of high-strength concrete (HSC) with a compressive strength of 60~80 MPa. Generally, the efficiency of HSC high-pressured pumping is dramatically reduced due to entanglement of short fibers added to prevent fire spalling. Therefore, the fire resistant admixture that can facilitate pumping of fire resistant HSC is urgently needed presently. The fire resistant HSC mix is comprised of Polypropylene fiber, Nylon fiber and Polymer powder. The test results showed that the slump-flow was improved by approximately 70% of the HSC without fire resistant admixture. However, the air void content was increased slightly due to the addition. The standard design compressive strength at 28-days was satisfied, while its flexural strength was similar to the concrete without the admixture. Since the flexural strength was 12~15% of its compressive strength, the general trend of flexural to compressive strength ratio in normal concrete was maintained. Even though its elastic modulus was decreased by adding the admixture, the study results showed that the concrete can be used for construction since all of the test results exceeded the code requirements.

Proposal of A Method to Enhance Pumping Efficiency of Cementitious Materials by Injecting Activation Agent to Slip-Layer and its Lab-Scale Experimental Verification (시멘트계 재료의 펌프압송성능 향상을 위한 윤활층 활성화제 주입 방법 제안 및 소규모 실험검증)

  • Lee, Jung-Soo;Yoo, Yong-Sun;Han, Jin-Gyu;Park, Chan-Kyu;Kwon, Seung-Hee
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.4
    • /
    • pp.442-449
    • /
    • 2017
  • In this study, a method to inject small amount of activation agent from the outside of the pipeline to the inside wall of the pipe was newly proposed to enhance pumping efficiency of cementitious materials. The activation agent is injected into the slip-layer, which is generally formed in the vicinity of the inside wall of the pipe during pumping cementitous materials. Through the injections, it is expected to decrease viscosity of slip-layer, namely, the friction between the mateirals and the pipe. The proposed method was verified by lab-scale pumping tests with mortars having water to cement ratio of 47%. The tests were performed with two different type of activation agents(superplasticizer and anionic surfactant) and three different amount of the agents(0.14, 0.28, 0.42% of the mortar volume). The compressive strength were measured with and without injecting the activation agent, and the internal pressures of pipeline were measured. When the anionic surfactant was used, there was no change in the compressive strength. As the amount of anionic surfactant increased, the pumping pressure decreased up to 71.4% at the maximum.

Prediction of Pumping Friction Resistance Coefficient in Pipe Influenced by Concrete Rheology Properties (콘크리트의 레올로지 특성에 따른 펌핑관내 마찰저항계수의 예측에 관한 연구)

  • Kim, Hyung-Rae;Cho, Ho-Kyoo;Kim, Jung-Chul;Lee, Kewn-Chu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.2
    • /
    • pp.118-126
    • /
    • 2014
  • The establishment of the technology for evaluating friction resistance and pipe pressure and the relation of the fluid characteristics and pumpability of concrete is essential for concrete pumping performance for the rapid construction of super-tall buildings. In this study, a quantitative evaluation of concrete fluid characteristics and surface friction resistance was performed, applying different concrete mix proportions and pumping conditions. To achieve this, we developed a temporary horizontal pumping evaluation system to measure pipe pressure and surface friction characteristics, and performed an experiment to investigate the relations between concrete rheology characteristics and friction resistance in pipe. The experiment found that in terms of the rheology characteristics, plastic viscosity was reduced remarkably after pumping. As well, high regression between the surface friction and pressure gradient was confirmed. This means that it is possible to evaluate the friction resistance between concrete and pipe by means of a pumping system that includes a frictional resistance testing pipe. In addition, high regression between the plastic viscosity of concrete after pumping and friction resistance coefficient was confirmed. Finally, it is considered that pumping pressure can be predicted using the friction resistance coefficient derived in this study, and it has high regression.

The Effects of Curing Environment and Submerged Pump Pressure on the Strength of High-Strength Grout (양생환경 및 수중펌프압송이 고강도 그라우트의 강도에 미치는 영향)

  • Kim, Beom-Hwi;Son, Da-Som;Yi, Chong-Ku
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.191-192
    • /
    • 2023
  • In recent years, the use of high-strength grout has gained popularity in offshore wind power generation complexes for facility foundations and bridges. These marine wind farms require support for horizontal loads from wind and waves. To ensure the strength of the grout produced in environments similar to the actual placing site, this study investigated the curing of high-strength grout discharged through pump pressure in various environments, and examined the difference in strength according to different variables. Compressive strength measurements revealed that the core specimen collected from the bottom (3cm) and uppermost (50cm) of the specimen exhibited lower strength compared to other height specimens, while the core specimen obtained from the corner exhibited lower strength compared to the center. These findings suggest that the strength difference between the center and the corner is more pronounced when curing at low temperatures. This effect is greater than the strength reduction that typically occurs during low-temperature curing, and thus, necessitates careful attention in similar construction environments.

  • PDF

Pulling Force and Manure Spreading Characteristic of Tractor-drawn Animal Slurry Manure Sub-soil Injector (가축분뇨액비 지중살포기의 견인력 및 살포 특성)

  • Choe K. J;Lee S. H.;Ryu B. K.;Oh K. Y.;Park H. J.;Lee S. T.
    • Journal of Animal Environmental Science
    • /
    • v.11 no.1
    • /
    • pp.25-34
    • /
    • 2005
  • The study aimed to develop a tractor drawn animal slurry manure sub-soil injector for arable land and thus, can reduce the waste management cost through effective treatment and utilization of animal slurry manure. The application of animal slurry manure to agricultural land will probably be one of the most effective ways to enrich the soil with vital nutrients. However, some existing slurry manure spenders are not suitable in the field because of their adverse effects to the environment. Based on this premise, a prototype was designed and assembled using 5 sub-soiling standards attached to the sin injector device. The traction force of the Prototype measured in the depth of 10 cm and 15 cm from the ground surface of a paddy field was 1,062 kgf and 1,214 kgf, respectively. A unique feature of the machine was that there was an equal volume of slurry manure flowing from each delivery pipe and regulated by a pressurized container that was likewise synchronized with the speed of the tractor The sub-soiling manure injection system can mitigate or reduce the harmful emission of obnoxious gases and malodor during the injection operation.

  • PDF

Optical Observation of Cavitation Phenomena in Diesel Fuel Injection Pumps (디젤 엔진 연료 분사 펌프 캐비테이션 현상의 가시화 연구)

  • Ryu, Seung-Hyup;Kim, Dong-Hun;Kim, Byung-Seok;Park, Tae-Hyung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.460-467
    • /
    • 2011
  • Cavitation phenomena during the spill process of the Bosch type fuel injection pump for medium-speed diesel engine were investigated by optical observations. Typically, these phenomena can cause a surface damage with material removal or round-off at the plunger and barrel port etc., and may shorten their expected life time. The images, which were recorded with high speed CCD camera and borescope, show that the plunger damage is mainly affected by fountain-like cavitation generated before the end of delivery. And the damages of barrel port and deflector are caused by jet-type cavitation generated after end of delivery.

A Study on Field Applicability of Sliding Pipe Rheometer (슬라이딩 파이프 레오미터의 현장 적용성에 관한 연구)

  • Yoon, Ju-Yong;Choi, Byung-Keol;Park, Yong-Kyu;Kim, Mok-Kyu;Choi, Sang-Hun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.239-240
    • /
    • 2023
  • In this study, concrete pumpability was investigated using a sliding pipe rheometer when the slump was different, and the cause was analyzed by comparing the actual field pump pressure. As a result of the experiment, it was found that the concrete pumpability was greatly affected by the slump measurement value.

  • PDF

An Experimental Study on the Pumpability Considering an Effective Ratio of Concrete Delivery Cylinder in Stationary Concrete Pump. (고정식 콘크리트 펌프의 콘크리트 실린더 실효율을 고려한 펌프압송성에 관한 실험적 연구)

  • Kwon, Hae-Won;Bae, Yeoun-Ki;Lee, Jae-Sam;Kim, Seog-Il;Kim, Hyun-Seob;Lee, Jong-Seo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.149-150
    • /
    • 2009
  • The effective ratio of the concrete delivery cylinder has meaning which is important in the performance analysis of stationary concrete pump. But, from experiment or test of most it assumes the effective ratio of the concrete delivery cylinder simply to 90${\sim}$95% level and it is applying. It will follow hereupon and it will be able to grasp the performance of stationary concrete pump by mistake. So we confirm a discharge quantity per time consequently and with, accurately to measure the effective ratio of the concrete delivery cylinder there is a necessity which it will analyze. Experimental resultant existing presumed it apppeared with the fact that it is visible the low-end 70${\sim}$75% level which it sees.

  • PDF