• Title/Summary/Keyword: 펌프실험장치

Search Result 188, Processing Time 0.023 seconds

Atomization Characteristics Experiment of Pintle Type Nozzle by the PDPA (PDPA에 의한 Pintle형 노즐의 미립화 특성실험 -식물유를 중심으로-)

  • 나우정;유병구;정진도
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.17-23
    • /
    • 1998
  • A simplified experiment was performed to figure out the atomization characteristics of highly viscous liquid of rice-bran oil by applying ultrasonic energy to improve the atomization of spray droplets. A spray system, an ultrasonic system, and three kinds of pintle-type nozzles(pin-edge angle: 5 , 10 , 15 ) were manufactured. To investigate the effects of ultrasonic energy on the atomization of a highly viscous liquid, a phase doppler particle analyzer was used for the measurement and calculation of spray droplets data. Nozzle opening pressures were chosen of 3 levels, i.e, 10, 13, 16 MPa. As a result, it could be concluded that the ultrasonic energy was effective to improve the spray atomization when applied to the fuel by means of 3 different nozzles because of the effects of the liquid fuel cavitation and relaxation between molecules caused by ultrasonic energy. The improvement rate of the spray atomization by the ultrasonic spray atomization by the ultrasonic spray compared with the conventional spray was about 10% increase in the case of pintle type nozzles. With the increase of pin-edge angles the distribution lines by nozzle opening pressures are declined for both conventional and ultrasonic sprays. This means that the increase of the pin-edge angle improves the atomization of sprays.

  • PDF

A Study on Oil Hydraulic Heat Generation System for Wind Energy Utilization (풍력에너지 이용을 위한 유압식 열변환 장치에 관한 연구)

  • Lee, Il-Young;Gong, Tae-Hee
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.4
    • /
    • pp.402-412
    • /
    • 1995
  • A new energy conversion system which converts wind energy directly to heat instead of transforming it to electric power beforehand is suggested in this study. The new energy conversion system is composed of two big parts divided by their functions. One of them is a wind turbine part, and another is the heat energy conversion part. The object of this study is confined only to the heat energy conversion part, so the wind turbine is replaced with an electric motor for the convenience of experiment. In the experimental process, pressure difference at the hydraulic pump, revolution speed of the hydraulic pump, temperature at a few points on the oil circuit and the water circuit are measured at time intervals of five minutes. And integral values of input energy to the system and stored energy in the system is investigated.

  • PDF

Experiment of Air Bubble Movement (Air Bubble 거동 특성 실험)

  • Kim, Seong Goo;Lee, Hyo Sang;Chang, Hyung Joon;Park, Ki Soon;Lee, Ho Jin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.512-512
    • /
    • 2017
  • 날로 심각해지는 해수 오염, 유류사고, 해파리에 의한 인명피해 및 발전소의 경제적 피해사고, 해양 쓰레기 등과 같은 해양 환경 문제가 발생하고 있다. 이러한 해양환경문제를 해결하기위해 생물학적 방법과 물리적 방법이 있으나 생물학적 방법은 개체군과 종류의 변화로 그 적용이 어려운 실정이고, 물리적 방법은 지속적인 제거를 위한 비용적인 문제와 인부 및 자원봉사자의 안전문제가 발생한다. 따라서 에어버블을 이용한 각종 친환경적 방법이 주목받고 있다. 본 연구에서는 에어버블 차단막의 차단율을 증가시키기 위해 현장조건 내에서 에어버블의 거동특성에 대한 실험을 하였다. 실험을 위해 회류식 개수로 에어버블 거동실험장치를 제작하였다. 실험장치는 길이 8.1m, 높이 1.2m, 폭 0.7m이며, 두께 10mm의 투명 아크릴를 사용하여 에어버블의 거동을 관찰 할 수 있게하였다. 대형펌프를 사용하여 물이 회류함을 통해 흐름유속을 만들어 현장조건을 고려하였다. 에어버블을 분사하기 위해 압축공기 저장탱크와 연결된 분사구가 있으며, 노즐의 크기(0.5mm~1.0mm)로 분사량을 조절하고 분사압은 별도의 조절장치를 이용하여 0~5bar 범위의 분사압 조절을 가능하게 하였다. 초고속 카메라와 3축유속계를 사용하여 에어버블의 이동경로, 유속 및 에어버블의 거동을 측정하였다. 실험을 통한 구간별 에어버블의 거동 분석 결과, 상승속도는 분사구에서 분출되는 구간인 0~0.8m 에서는 상승속도가 증가하고, 0.8~1.2m구간에서는 속도가 다시 상승하는 경향을 확인하였다. 이는 수표면에 가까워질수록 수압이 작아져서 에어버블의 크기가 커짐에 따라 부력이 커짐으로 판단된다. 같은 이유로 분사량이 많을수록 상승속도도 같이 증가되는 것으로 나타났다. 유속에 따른 거동은 유속을 0.1m/s~0.5m/s로 조정하여 유속별 에어버블이 수표면까지 도달하는 거리, 속도 및 이동경로를 분석하였다. 유속과 에어버블이 수표면까지 도달하는 거리는 비례하여 증가하는 것을 확인하였다. 실험결과를 바탕으로 조건에 따른 에어버블 거동 경험식을 도출하였다. 본 실험은 회류식 개수로 에어버블 거동실험장치를 활용하여 에어버블 거동 경험식을 제시하였으며, 이를 바탕으로 에어버블 차단막 기술 개발을 위한 기초자료로 이용될 수 있을 것이다.

  • PDF

Simulation to identify the frost formation of the heat pump outdoor unit (히트펌프 실외기의 서리층 형성을 파악하기 위한 시뮬레이션)

  • Kim, Jong-Ryeol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.1410-1419
    • /
    • 2019
  • In this research, it is to find a method that frost does not form on the outdoor unit to develop a heat pump capable of heating in cold regions. For this reason, we produced an incubator capable of creating an environment of -25℃, and constructed an experimental apparatus so that experiments in the room were possible. However, it is necessary to grasp the characteristics of the air reaching the front of the heat pump outdoor unit installed in the experimental apparatus, and flow analysis was performed using ANSYS CFX, which is general-purpose software. As a result, the flow velocity of the air reaching the front of the outdoor unit in the outdoor unit chamber in the entire region of the simulation conditions (5.0 to 7.5 m/s) has many differences in the upper and lower portions, resulting in a natural state. It turned out that the condition can not be satisfied. Therefore, it is determined that it is necessary to additionally install a frequency divider at the front of the outdoor unit to make the flow velocity constant.

Stainless-steel sxtreme high vacuum system with a new combination pump (새로운 조합 펌프를 사용한 스테인레스 스틸 극고진공 시스템)

  • 전인규;조복래;정석민
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.1
    • /
    • pp.1-4
    • /
    • 1998
  • We have developed an extreme high vacuum (XHV) system using a new combination pump cpmposed of a suitably shaped NEG(Non-Evaporable Getters) in the body of a sputter-ion pump (SIP). The stainless-steel test chamber was used which had been well oxidized at $450^{\circ}C$ and already yielded XHV with a turbomolecular pumping system. The pressure was measured by a Leybold extractor gauge (EXG,limit:1~$2{\times}10^{-12}$torr, but in the ultimate pressure regionthe EXG shows an unusual sign as $-0.{\times}10^{-12}$ torr which indicates much lower pressure range than its available lower limit. These results are mainly due to the high pumping speed of NEG for hydrogen. Furthermore, use of the SIP combined with the NEG as a XHV pumping system implies the potential for actualization of the surface analysis under XHV environment, and allows one to have a chance tp meet a new world in nanometer science and technology.

  • PDF

CFD on the possibility of performance evaluation of heat pump outdoor unit in duct-type constant temperature chamber (덕트형 항온챔버에서 히트펌프 실외기의 성능평가 가능성에 대한 CFD)

  • Kim, Jong-Ryeol
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.3
    • /
    • pp.116-121
    • /
    • 2021
  • A lot of research is being done to develop a high-efficiency heat pump to save energy, and research to reduce or eliminate the phenomenon of frost occurring in the outdoor unit coil is also being conducted at the same time. A curved constant temperature chamber was constructed that can be tested under the same conditions as in the natural state so that the research can be conducted in which frost does not occur on the outdoor unit of the heat pump regardless of the season. Simulations were performed to verity whether such a curved constant temperature chamber has feasibility as an experimental device. For CFD conditions, the length of the straight duct in front of the outdoor unit located in the duct-type constant temperature chamber was 1, 5, 10 and 15 times the diameter of the duct. As a result, it was found that a straight space must be secured 10 times the diameter of the duct.

An Experimental Study on the Operating Performance of an Air Shift type Heat Pump with Heat Exchanger (전열교환기가 설치된 기류전환형 히트펌프의 동계운전성능에 관한 실험적 연구)

  • Jang, Young-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.8
    • /
    • pp.567-572
    • /
    • 2010
  • Air shift type heat pump is combined heat recovery ventilator and refrigerator, and it is installed an air shifter changing air flow. And so it is an perfect AHU(Air Handling Unit) capable to cooling, heating, ventilation and heat recovery. Therefore, an experimental study has been carried out to investigate the operating performance in winter for this system. An experimental data are room temperature, inlet/outlet temperature of condenser, evaporator and heat exchanger. They have been measured as the variation of outdoor temperature. The results, in case of rising above freezing, the air shift type heat pump system is operated normally, and the heating COP is 3.0~4.2 by varying outdoor temperature from $-3^{\circ}C$ to $15^{\circ}C$.

The plan of depreciation vortex developing a Pump suction Pipes through Sump model test (수리모형실험을 통한 펌프 흡입배관부 보텍스 현상 저감방안)

  • Ahn, IS;Kim, SH;Kim, KY;Roh, HW;Lee, YH
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.193-198
    • /
    • 2004
  • In general, the function of intake structure, whether it be a open channel, a fully wetted tunnel, a sump or a tank is to supply an evenly distributed flow to a pump station. An even distribution of flow, characterized by strong local flow, can result in formation of surface or submerged vortices, and with certain low values of submergence, my introduce air into pun, causing a reduction of capacity and efficiency, an increase in vibration and additional noise. This study investigated experimentally the formation of the vortex to understand the mechanism of vortex formation and to prevent the formation of vortex in the sump model using by the model test and PIV tool. Sump model was manufactured to 1/8 scale with the drawing of W intake pumping station. from the results of model test and PIV, the vortex were occurred the in the whole section. Thus, sump model tests with the anti-vortex device might be considered to prevent the formation of vortex in the sump model.

  • PDF

A Study of Optimal Model for the Circuit Configuration of Korean Pulsatile Extracorporeal Life Support System (T-PLS) (한국형 박동식 생명구조장치(T-PLS) 순환회로를 위한 최적화 모델 연구)

  • Lim Choon Hak;Son Ho Sung;Lee Jung Joo;Hwang Znuke;Lee Hye Won;Kim Kwang Taik;Sun Kyung
    • Journal of Chest Surgery
    • /
    • v.38 no.10 s.255
    • /
    • pp.661-668
    • /
    • 2005
  • Background: We have hypothesized that, if a low resistant gravity-flow membrane oxygenator is used, then the twin blood sacs of TPLS can be located at downstream of the membrane oxyenator, which may double the pulse rate at a given pump rate and increase the pump output. The purpose of this study was to determine the optimal configuration for the ECLS circuits by using the concept of pulse energy and pump output. Material and Method: Animals were randomly assigned to 2 groups in a total cardiopulmonary bypass model. In the serial group, a conventional membrane oxygenator was located between the twin blood sacs. In the parallel group, the twin blood sacs were placed downstream of the gravity-flow membrane oxygenator. Energy equivalent pressure (EEP) and pump output were collected at pump-setting rates of 30, 40, and 50 BPM. Result: At the given pump-setting rate, the pulse rate was doubled in the parallel group. Percent changes of mean arterial pressure to EEP were $13.0\pm1.7,\; 12.0\pm1.9\;and\;7.6\pm0.9\%$ in the parallel group, and $22.5\pm2.4,\; 23.2\pm1.9,\;and\;21.8\pm1.4\%$ in the serial group at 30, 40, and 50 BPM of pump-setting rates. Pump output was higher in the parallel circuit at 40 and 50 BPM of pump-setting rates $(3.1\pm0.2,\;3.7\pm0.2L/min\;vs.\;2.2\pm0.1\;and\;2.5\pm0.1L/min,\;respectively,\;p=0.01)$. Conclusion: Either parallel or serial circuit configuration of the ECLS generates effective pulsatility. As for the pump out, the parallel circuit configuration provides higher flow than the serial circuit configuration.

Surgical Technique for Korean Artificial Heart(AnyHeart) Implantation Using a Right Thoracotomy Approach (우측 개흉술을 이용한 한국형 인공심장(AnyHeart)의 이식기법)

  • Son. Ho-Sung;Sun, Kyung;Shin, Jae-Seung;Lee, Sung-Ho;Jung, Jae-Seung;Lee, Hye-Won;Kim, Kwang-Taik;Kim, Seung-Chul;Won, Yong-Soon;Min, Byoung-Goo;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.35 no.5
    • /
    • pp.329-335
    • /
    • 2002
  • Background: The surgical technique for biventricular assist device(BVAD) implantation has mainly consisted of cannulation procedures. A median sternotomy has been the technique of choice as it gives a surgeon an excellent exposure of the heart. However, considering that most patients require a future sternotomy or already have a previous sternotomy, sternotomy-related complication remains a major concern in BVAD implantation. Based on this consideration as well as the clinical experiences of conventional heart surgery, the authors have hypothesized that the cardiac chambers for BVAD cannulation can be approached from the right side of the heart. The purpose of this studs to develop a novel surgical technique of right thoracotomy for BVAD implantation in an animals study. Material and Method: For last two years, 16 (11 calves, 3 canines, and 2 sheep) out of 30 experimental animals with AnyHeart implantation underwent a right thoracotomy. The device was used as an implantable BVAD in 14 animals, a wearable BVAD in 1, and an implantable LVAD in 1. The chest cavity was entered through the 4th intercostal space or the 5th periosteal bed. As for the BVAD use, a right inflow cannula was inserted into the right atrial free wall and a right outflow cannula was grafted onto the main pulmonary artery. A left inflow cannula was inserted into the interatrial groove and a left outflow cannula was grafted on the innominate artery of the ascending aorta. The connecting tubes were brought out through the thoracotomy wound and connected to the pump located in the subcutaneous pocket at the right flank. Result: Except for the 5 animals for a lilting test or during the early learning curve, all recovered smoothly from the procedures. The inflow drainage allowed the pump output 6.5 L/min at the maximum with 3-3.5 L/min in an average. Of the survivors, there noted no procedure-related mortality or morbidity. Necropsy findings demonstrated the well-positioned cannula tips in the each cardiac chamber