• 제목/요약/키워드: 펄스 코로나

검색결과 54건 처리시간 0.027초

펄스코로나 방전에서 프로핀($C_3H_6$)이 NO-$NO_2$ 변환에 미치는 영향에 관한 연구 (Effect of Propene($C_3H_6$) ON NO-$NO_2$ Conversion Process in a Pulsed Corona Discharge)

  • 박광서;전배혁;전광민
    • 한국자동차공학회논문집
    • /
    • 제8권5호
    • /
    • pp.67-77
    • /
    • 2000
  • Investigated was the effect of propene(C3H6) on the NO-NO2 conversion in dry exhaust gases from lean burn engine using a pulsed corona discharge. A kinetic model was developed to characterize the plasma chemistry in simulated exhausts containing propene. The model uses ELENDIF program to solve Boltzmann equation for electron energy distribution function, and CHEMKIN-II program to solve stiff ODE(ordinary differential equation) problems for species concentrations. The corona discharge energy per pulse and the time-space averaged E/N were obtained by fitting the model to experimental data. The model calculation shows good agreement for NO and NO2 concentrations with the experimental data, and predicts the formation of byproducts such as CH2O, CH3HCO, CO AND CH3NO2 Propene enhances the NOx conversion enormously at lower energy density and the NOx conversion increases with the increase of initial propene and oxygen concentration, and temperature.

  • PDF

피에조를 이용한 코로나 방전과 펄스교류 코로나 방전을 이용한 정전기 제거장치의 비교 연구 (A Comparative Study on the Electrostatic Eliminator of Piezo Type Ionizer and Pulse AC Corona Type Ionizer)

  • 권승열;이동훈;최재욱
    • 한국안전학회지
    • /
    • 제24권6호
    • /
    • pp.50-54
    • /
    • 2009
  • Ionizer is used for improving manufacturing process and reducing inferior goods in the clean room. As a general rule, neutralization of the electrostatic charge is most important to make TFT-LCD, PDP and OLED. Pulse AC-static eliminator with output voltage of about 10.5kV has been used these days as neutralization device. But this device has a problem with lower performance which was caused by particles-adhesion on the electrode when it has been used for a long time. So we studied to solve the problem with lower performance using high Frequency(72kHz) static eliminator which was produced by Piezo transformer device, and compared Pulse-AC type with Piezo-electronic device such as decay time and ion balance for 10 weeks periods. As a result of this study, we found that Piezo transformer device has been maintained normal condition for 10 weeks. Also, we made the rule by this study, normally Piezo transformer device has to clean the electrode during every 11th weeks.

펄스 코로나 반응기에서 방전극의 배열에 따른 탈질율 연구 (A Study on the NOx Removal Rate by Arrangement of Discharge Electrode in Pulsed Corona Discharge Reactor)

  • 최민;박소진;위영호
    • 한국대기환경학회지
    • /
    • 제19권3호
    • /
    • pp.315-323
    • /
    • 2003
  • The goal of this study if the optimization of discharge electrode for pulsed corona discharge reactor located in thermal power plant. For this purpose, we have performed experiments of NO$_{x}$ removal rate by exchange of discharge electrode diameter and arrangement of discharge electrode in the non -thermal plasma reaction facility using a ethylene as additive. If the diameter and numbers of discharge electrode were larger, the NO$_{x}$ removal rate was higher. From these results, if we optimized the shape and installed numbers of discharge electrode at the pilot plant, we could increase the NO$_{x}$ removal rate with less amount of additive than current amount.mount.

회전기 고정자권선의 부분방전 진단을 위한 Corona probe의 설계 및 실험 (Design and Experiment of the Corona Probe for Partial Discharge Diagnosis in Rotary Machine Stator Windings)

  • 양상현;이세일;이용성;박노준;김희동;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1479_1480
    • /
    • 2009
  • 부분방전시험은 고전압 고정자 권선의 절연상태를 검사, 평가 할 수 있는 중요한 수단이다. 전동기와 발전기에서 일어나는 절연 악화의 징후로써 부분방전이 발생되며 이러한 부분방전 결함의 정확한 위치 확인이 필요하다. 본 논문에서는 회전기 고정자권선의 결함위치를 판정하기위한 Prototype의 코로나 프로브를 설계하고자 Ferrite core를 이용한 Corona Probe를 제작하였으며 모의 결함을 가지는 6.6[kV] 회전기 고정자권선에 적용하여 부분방전펄스를 측정 하였으며 설계된 Probe의 신뢰성을 확인하고자 상용 HFCT센서와 PPM97(Corona Probe)센서를 통하여 검출감도를 비교분석하였다.

  • PDF

상온 펄스 코로나 방전 공정에 의한 NO 제거 효율 (NO Removal Efficiency by Pulsed Corona Discharge Process at Room Temperature)

  • 김동주;박정환;김교선
    • 한국대기환경학회지
    • /
    • 제18권5호
    • /
    • pp.337-344
    • /
    • 2002
  • In this study, we analyzed the NO removal efficiency by the pulsed corona discharge process and investigated the effects of several process variables such as initial concentrations of NO, $H_2O$, and NH$_3$, applied voltage, pulse frequency, diameter of the discharge electrode, and residence time. The removal efficiency of NO increased by the addition of $H_2O$ or NH$_3$, but the changes of initial NH$_3$ and $H_2O$ concentrations did not affect the removal efficiency of NO significantly. With the increases of the applied voltage or the residence time, the removal efficiency of NO increased. In addition, with the increases of the pulse frequency of applied voltage, or the diameter of the discharge electrode, the removal efficiency of NO increased. The experimental results can be used as a basis to design the pulsed corona discharge process to remove NO$_{x}$, SO$_{x}$ and VOCs.OCs.

펄스 코로나 농약산포장치의 분무대전 특성 (Pulsed Corona Charging Characteristics of Aqueous Pesticide Spray)

  • 문재덕;이운태;배창환;권남열
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권9호
    • /
    • pp.388-394
    • /
    • 2003
  • Many toxic pesticides as aqueous-base sprays are dispensed for protection of food crops from pests into farm fields. When dispensed with conventional nozzles, a large portion of the spray is often lost by airborne drifts of droplets away and lack of deposition onto the plants due to rapid gravitational settling of droplets to the soil beneath. And target deposition efficiencies poorer than 20% are often encountered in agricultural pesticides. An electrostatic spraying technology offers a very favorable means to increasing pesticides droplets deposition onto biological surfaces of living crops. In this paper a corona type spray nozzle, utilizing a set of corona charging devices and a pulsed droplet-charging voltage applied, has been proposed and tested its potential experimentally. As a result, it exhibits a large current deposition of aqueous pesticide sprays on the sensing target, which, however, promise to be as one of the effective electrostatic spraying nozzle.

Wire-Plate 반응기에서 펄스 코로나 방전을 이용한 탈황 탈질에 관한 연구 (A Study on the Removal of SOx/NOx by a Pulsed Corona Discharge in the Wire-Plate Reactor)

  • 신완호;송영훈;김한석;최연석;김석준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1910-1912
    • /
    • 1996
  • This paper presents the results of laboratory experimentals to remove $SO_2$ and $NO_x$ by a pulsed corona discharge in the wire-plate reactor. A rotating spark gap switch was used to generate the pulse by chewing the dc high voltage. Repetition frequency of the pulse was 60Hz and rising time of 50ns. The photo pictures of positive streamer corona taken by ICCD camera, pulse voltage and current were measured using a digital oscilloscope. Simultaneous effects of $C_{2}H_{4}$ injection and heterogeneous chemical reactions on nonthermal plasma process to remove $SO_2$ and $NO_x$ from flue gas were investigated in the present study

  • PDF

저온 플라즈마 장치에서 $C_2H_4$의 첨가량이 NOx 저감에 미치는 영향에 대한 실험적 연구 (An Experimental Study on Effect of Adding $C_2H_4$ for Reduction of NOX using Low Temperature Plasma Apparatus)

  • 권준호;강우정;정태용
    • 한국자동차공학회논문집
    • /
    • 제6권4호
    • /
    • pp.211-218
    • /
    • 1998
  • The purpose of this study is to investigate the reduction rate of NOX according to several parameters(NOX concentration, the flow rate of gas, the additional amount of C2H4, input voltage, input frequency and so in) when NOX is reduced by using PPCP(Pulse-induced Plasma Chemical Process). PPCP is based on the plasma-chemical technology, which induces narrow voltage pulses to binary electrode structure.

  • PDF

펄스 스트리머 방전을 이용한 NOx 제거 (Removal of NOx by Pulsed Streamer discharge)

  • 고희석;박재윤;김건호
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권8호
    • /
    • pp.807-811
    • /
    • 1997
  • In this paper we have investigated the removal characteristics of NOx by pulsed corona discharge with a multi-pointplane electrode where a magnetic field is applied in the discharge region. The efficiency of NOx removal was measured and analyzed as a function of pulse frequency gas flow rate NOx initial concentration magnetic flux density. In this result the highest removal efficiency of NOx was obtained at the following operating conditions; the frequency =400[Hz] gas flow =1[$\ell$/min] initial concentration= 400[ppm] and magnetic flux density=0.36[T].

  • PDF

펄스 코로나 방전을 이용한 NO제거 에너지 효율에 대한 연구 (A Study on the Energy Efficiency for NO Removal by Pulsed Corona Discharge)

  • 강훈;송봉식;이석현;도현호;김윤택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2010-2012
    • /
    • 1999
  • The product of electrons by Pulsed Corona Discharge leads to produce radicals which work on NO, and NO is finally removed. Energy efficiency for NO removal was improved with increasing peak voltage rather than with increasing pulse frequency. The rate of energy transfer increased with decreasing value of $C_p$( Pulse - Forming Capacitance 2.15, 1.06, 0.55, 0.36, 0.1[nF]. When the value of $C_p$ reached to 0.36 [nF], the energy efficiency for NO removal was maximized. And good agreement was obtained between chemical kinetic calculations and the experimental results.

  • PDF