• Title/Summary/Keyword: 팽창성능

Search Result 462, Processing Time 0.026 seconds

Evaluation of strength characteristics according to expansion amount of ground reinforced expanded polyol (지반보강 팽창약액의 팽창성능 및 밀도에 따른 강도특성 평가)

  • Kang, Hyounhoi;Kim, Kisung;Kim, Juho;Park, Jeongjun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.1
    • /
    • pp.35-42
    • /
    • 2017
  • In this study, to quantitatively evaluate the strength characteristics of the inflatable liquid used for the recovery of soft ground or partial settlement, the inflatable liquids were prepared by dividing the inflatable capacity and the strength characteristics were analyzed according to the conditions. The experimental group was divided into two groups: relatively high expansion group and low expansion group. The specimens were prepared by controlling the volume of 10 ~ 30% of the maximum expansion volume, and the strength of the specimens were evaluated. The compressive strength of the high expansion group and low expansion group was about 2.1 times.

Optimization of Design Pressure Ratio of Positive Displacement Expander for Engine Waste Heat Recovery of Vehicle (자동차 엔진 폐열 회수 동력시스템에서 용적형 팽창기의 설계 팽창비 최적화)

  • Kim, Young Min;Shin, Dong Gil;Kim, Chang Gi;Woo, Se Jong;Choi, Byung Chul
    • Journal of Energy Engineering
    • /
    • v.21 no.4
    • /
    • pp.411-418
    • /
    • 2012
  • The effect of built-in volume ratio of expander on the performance of a two-loop Rankine cycle system for engine waste heat recovery of vehicle has been investigated. In the case of positive displacement expander in the various operating condition of the vehicle, it can operate in both under-expansion and over-expansion conditions. Therefore, the analysis of off-design performance for the expander is very important. Furthermore, the volume and weight of the expander as well as the efficiency must be considered in the optimization of the expander. This study shows that the built-in volume ratio of expander causing under-expansion at a target condition is more desirable considering the off-design performance and size of the expander, based on the simple modeling of off-design operation of the expander.

Analysis of Performance of Organic Rankine Cycle for Inlet Condition of Displacement Type Expander (용적형 팽창기 입구 조건 변화에 따른 유기랭킨사이클 성능 분석)

  • Shin, Dong Gil
    • Journal of Energy Engineering
    • /
    • v.26 no.1
    • /
    • pp.23-27
    • /
    • 2017
  • An expander of an organic Rankine cycle is an essential component that significantly influences its entire performance and cycle efficiency. The inlet pressure and temperature of the expander used for the organic Rankine cycle are limited by the expander's mechanical properties and the characteristics of the working fluid. The organic Rankine cycle's output, heat absorption, and efficiency are altered by the inlet pressure and temperature of the expander. In this study, a theoretical comparative analysis was conducted on an organic Rankine cycle's performance changes, which are dependent on the inlet condition of the expander. The working fluid is an R134a refrigerant, and the expander is a positive-displacement type.

An Experimental Study on the Quality Properties of the Expansive for Dry-Shrinkage Compensation of the On-Dol Floor Mortar (온돌바닥 모르터의 건조수축 보상을 위한 팽창재의 품질특성에 관한 실험연구)

  • 이종열;이웅종;정성철
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.4
    • /
    • pp.314-320
    • /
    • 2001
  • In this paper, the properties of an expansive agent (CaO-CaS $O_4$) for dry shrinkage compensation were investigated by a series of experimental program, which might be used at On-Dol heating system as mortar type. The expansion principle of the CaO-CaS $O_4$ was mainly verified. As a result of this study, the correlation between the content of the expansive agent and the compressive strength was obtained in the form of exponential function(Y = A $e^{-x}$), showing that as the content of expansive agent increased as the expansion performance with the compressive strength increased by only a certain amount. Also, as a results of the analysis of a correlation between the expansive performance and the chemical properties which generally accompanied a part of quality management in manufacturing the expensive cement, the expansive performance was relative to only the contents of the F-CaO among chemical properties(Blaine, +44$\mu\textrm{m}$R, F-CaO, S $O_3$,L.O.I). And it was clarified that the results were relative to the second order function, showing that if the contents of the F-CaO increased the expansive performance Increased.d.

Applicability of Expansive Additive on Reducing Shrinkage in Ultra-High-Strength-Concrete (팽창재에 의한 초고강도 콘크리트의 수축저감)

  • Seo, Kyong-Won;Baek, Ki-Hyun;Kim, Young-Jin;Kwak, Do-Yeon
    • Magazine of the Korea Concrete Institute
    • /
    • v.21 no.1
    • /
    • pp.61-67
    • /
    • 2009
  • 본 연구에서는 초고강도 콘크리트의 자기수축 제어대책으로서 팽창재를 이용하는 경우의 적절한 첨가량 및 유효성에 대하여 확인하였고, 재팽창 현상에 대해서 검토하였다. 그 결과 물시벤트비가 극히 낮은 초고강도 콘크리트의 특성상 과첨가의 경우는 미반응의 팽창재가 잔존하고 재팽창 할 가능성이 있는 것으로 나타났으며 초고강도 콘크리트용의 팽창재로서는 가능한 미수화 팽창재가 잔존하지 않는 팽창재 즉 팽창성능을 충분히 가지면서 수화반응이 빠른 조강성의 비표면적이 큰 팽창재가 바람직한 것을 제안하고 있다.

Evaluation of waterproof and durability of hydrophilic waterstop (수팽창 지수재의 방수 성능 및 내구성 평가)

  • Choi, Woo-Yong;Lee, Hyeun-Pil;Jun, Gy-Chan;Lee, Seok-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.2
    • /
    • pp.117-124
    • /
    • 2014
  • The interest in the use of shield TBM (Tunnel Boring Machine) on the tunnel excavation has been increased rapidly in Korea. The shield TBM tunnel is generally designed as non-drainage tunnel. Consequently, if water leakage through the segment joints happens, big problems on the usage and stability of tunnel can be occurred. In this study, the variation of waterproof capacity of hydrophilic waterstop by the construction error and excessive displacement of segment was studied firstly. Secondly, the decrease of durability of hydrophilic waterstop by the sulphate and chloride contained in the groundwater and seawater was investigated. The results showed that if the angle discordance at the segment joints is beyond the 2 degree, the proper waterproof capacity of hydrophilic waterstop can not be guaranteed. In addition, if the hydrophilic rubber waterstop is exposed to the sulphate for a while, the proper durability of hydrophilic waterstop can not be expected.

Experimental Study on the Performance Characteristics of a Scroll Expander for 1kW-class Organic Rankine Cycle (1kW급 유기랭킨사이클용 스크롤 팽창기의 성능 특성에 관한 실험적 연구)

  • Kim, Dokyun;Yun, Eunkoo;Yoon, Sang Youl;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.41-48
    • /
    • 2015
  • The performance characteristics of a scroll expander is the most important variable for the performance of organic Rankine cycle system. In this paper, the performance characteristics of a scroll expander was identified using 1kW class organic Rankine cycle system with various operating conditions. The ORC system is composed of an evaporator, a scroll expander, a condenser and a working fluid feed pump that uses R245fa as working fluid. The hot water temperature was controlled from $80^{\circ}C$ to $115^{\circ}C$ by the 50kW-class electric water-heater. The maximum isentropic efficiency of the scroll expander was measured about 77%, and the shaft power was measured from 0.5 kW to 1.8 kW according to heat source temperatures.

Permeability Characteristics of Geosynthetics Vertical Barrier Connections for the Prevention of Contaminants Diffusion (오염물질 확산방지를 위한 토목섬유 연직차수벽 연결부의 투수성능 평가)

  • Park, Jeong Jun
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • Purpose: In this study, we used hydrophilic waterstop used in geosynthetics vertical barrier system to evaluate the performance of impermeability under sealing conditions. Method: ASTM D5887 and ASTM D6766 were applied to determine the capability of the connection during the geosynthetics vertical barrier system. Hydrophilic waterstop was saturated in each solution and the weight, thickness, and volume changes were analyzed over elapsed time. Hydrophilic waterstop was installed at the geosynthetics vertical barrier system connection to evaluate the permeability characteristics. Results: As the expansion reaction time of hydrophilic waterstop increased relatively under saline conditions, the decrease in permeability also showed a smaller decrease in fresh water. Furthermore, the method of engagement of the geosynthetics vertical barrier system showed somewhat better performance of the impermeability due to the large pressure resistance caused by the roll joint type than interlock type. Conclusion: In urban pollutants, which can estimate the outflow of pollutants such as oil storage facilities and industrial complexes, proactive response technologies that can prevent the contaminant diffusion can significantly reduce the damage.

Study on Reaction Rate of the Non-Explosive Demolition Agent (비폭성 파쇄재의 반응률 특성에 관한 연구)

  • ;Huipeng Ba
    • Tunnel and Underground Space
    • /
    • v.4 no.2
    • /
    • pp.87-91
    • /
    • 1994
  • 팽창재와 같은 비촉성 파쇄재는 화약발파와 비교하여 볼 때 진동을 유발하지 않는다는 면에서 인접한 구조물에 영향을 주지 않고 암반을 파괴할 수 있는 장점을 갖고 있다. 비폭성 파괴방법으로 유압식 암석분할기도 팽창재와 유사한 적용성을 갖고 있으나 힘을 작용시킬수 있는 천공깊이에 제약을 갖고 있으며 규모가 큰 암반의 파괴 방법으로는 적용한계가 있다. 반면에 팽창재는 천공깊이에 큰 제약을 받지 않으며 천공수에 제한을 받지 않는다는 장점이 있다. 그러나 팽창재의 현장적용시 가장 큰 단점의 하나로 지적되고 있는 것은 파괴력을 나타내기까지의 시간이 오래 걸림으로 작업능률에 문제가 있다는 것이다. 반응시간은 물과 팽창재와의 반응률과 밀접한 관계를 갖고 있으며 본 논문에서는 팽창재의 적용성을 높이기 위하여 실시한 여러 조건하에서 팽창재 반응률 특성에 관한 연구내용을 기술한다. 연구결과를 요약하면 다음과 같다. 1)팽창재의 반응은 주위온도에 큰 영향을 받는다. 2) 팽창재의 성능을 충분히 발휘하기 위하여는 주위 온도 조건에 따라 천공직경을 적절히 조절하는 것이 필요하다. 3) 낮은 주위 온도 조건에서 팽창재의 반응은 압력이 증가하는 시간이 느리고 따라서 최대 팽창압이 높은 온도 조건에 비해서 낮게 나타난다. 4)팽창압이 증가하는 시간은 팽창재와 물과의 반응률에 좌우된다.

  • PDF