• Title/Summary/Keyword: 판독거리

Search Result 53, Processing Time 0.033 seconds

Mobile Mapping System Development Based on MEMS-INS for Measurement of Road Facility (도로시설물 계측을 위한 MEMS-INS 기반 모바일매핑시스템(MMS) 개발)

  • Lee, Kye Dong;Jung, Sung Heuk;Lee, Ki Hyung;Choi, Yun Soo;Kim, Man Sik
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.36 no.2
    • /
    • pp.75-84
    • /
    • 2018
  • The purpose of this study is that the low-cost mobile mapping system using INS (Inertial Navigation System) based on MEMS (Micro Electro Mechanical System) could decipher the interpretation of road facility with the accuracy of x, y 0.546m plane error. Even though the MMS (Mobile Mapping System) technology as a new measurement technology has been used vividly to set up geographic information by some world leading surveying equipment manufacturers, the domestic technology is still in its beginning stage. Several domestic institutes and companies tried to catch up the leading technology but they just produced prototypes which needs more stabilization. Through this thesis, we developed low-cost mobile mapping system installed with INS based on MEMS after time synchronizing sensors for MMS such as LiDAR (Light Detection And Ranging), CCD (Charge Coupled Device), GPS/INS (Global Positioning System / Inertial Navigation System) and DMI (Distance Measurement Instrument).

A study on way-finding information design of Seoul metropolitan subway -Focused on Bus transfer information- (수도권 지하철 길 찾기 정보 디자인 연구 -연계버스안내를 중심으로-)

  • Yun, So-Hee;Kim, Seung-In
    • Journal of Digital Convergence
    • /
    • v.14 no.7
    • /
    • pp.425-430
    • /
    • 2016
  • This study is to improve the design of bus transfer information that can be substantially used. This study has been processed using the following steps. First, I tried to define the information design and way-finding information design. Secondly, I have researched several case studies, and considered solutions. Finally, I evaluated way-finding maps through pair-wise comparisons, and drew needs through an interview. As the result of this research, there were some problems in font size, improper space between letters and non-consistent information. To solve these problems, the information has to be clear using easy symbols to be well-recognized by citizens. Also, the font size needs to be decided by a calculation of minimum legible size of letters. Lastly, a value contrast between a background color and a letter color needs to be applied more than 70 percent for better visibility. The study is expected to be used as a reference which helps informational design to be developed.

Development of Neutron Induced Prompt γ-ray Spectroscopy System Using 252Cf (252Cf 선원을 이용한 즉발감마선 계측시스템 구성)

  • Park, Yong-Joon;Song, Byung-Chul;Jee, Kwang-Yong
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.12-24
    • /
    • 2003
  • For the design and set-up of neutron induced prompt ${\gamma}$-ray spectroscopy system using $^{252}Cf$ neutron source, the effects of shielding and moderator materials have been examined. The $^{252}Cf$ source being used for TLD badge calibration in Korea Atomic Energy Research Institute was utilized for this preliminary experiment. The ${\gamma}$-ray background and prompt ${\gamma}$-ray spectrum of the sample containing Cl were measured using HPGe (GMX 60% relative efficiency) located at the inside of the system connected to notebook PC at the outside of the system (about 20 meter distance). The background activities of neutron and ${\gamma}$-rays were measured with neutron survey meter as well as ${\gamma}$-ray survey meters, respectively and the system was designed to minimize the activities. Prompt ${\gamma}$-ray spectrum was measured using ${\gamma}$-${\gamma}$ coincident system for reduce the background and the continuum spectrum. The optimum system was designed and set up using the experimental data obtained.

Boundary-enhanced SAR Water Segmentation using Adversarial Learning of Deep Neural Networks (적대적 학습 개념을 도입한 경계 강화 SAR 수체탐지 딥러닝 모델)

  • Hwisong Kim;Duk-jin Kim;Junwoo Kim;Seungwoo Lee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.2-2
    • /
    • 2023
  • 기후변화가 가속화로 인해 수재해의 빈도와 강도 예측이 어려워짐에 따라 실시간 홍수 모니터링에 대한 수요가 증가하고 있다. 합성개구레이다는 광원과 날씨에 무관하게 촬영이 가능하여 수재해 발생시에도 영상을 확보할 수 있다. 합성개구레이다를 활용한 수체 탐지 알고리즘 개발이 활발히 연구되어 왔고, 딥러닝의 발달로 CNN을 활용하여 높은 정확도로 수체 탐지가 기능해졌다. 하지만, CNN 기반 수체 탐지 모델은 훈련시 높은 정량적 정확성 지표를 달성하여도 추론 후 정성적 평가시 경계와 소하천에 대한 탐지 정확성이 떨어진다. 홍수 모니터링에서 특히 중요한 정보인 경계와 좁은 하천에 대해서 정확성이 떨어짐에 따라 실생활 적용이 어렵다. 이에 경계를 강화한 적대적 학습 기반의 수체 탐지 모델을 개발하여 더 세밀하고 정확하게 탐지하고자 한다. 적대적 학습은 생성적 적대 신경망(GAN)의 두 개의 모델인 생성자와 판별자가 서로 관여하며 더 높은 정확도를 달성할 수 있도록 학습이다. 이러한 적대적 학습 개념을 수체 탐지 모델에 처음으로 도입하여, 생성자는 실제 라벨 데이터와 유사하게 수체 경계와 소하천까지 탐지하고자 학습한다. 반면 판별자는 경계 거리 변환 맵과 합성개구레이다 영상을 기반으로 라벨데이터와 수체 탐지 결과를 구분한다. 경계가 강화될 수 있도록, 면적과 경계를 모두 고려할 수 있는 손실함수 조합을 구성하였다. 제안 모델이 경계와 소하천을 정확히 탐지하는지 판단하기 위해, 정량적 지표로 F1-score를 사용하였으며, 육안 판독을 통해 정성적 평가도 진행하였다. 기존 U-Net 모델이 탐지하지 못하던 영역에 대해 제안한 경계 강화 적대적 수체 탐지 모델이 수체의 세밀한 부분까지 탐지할 수 있음을 증명하였다.

  • PDF

Development of Velocity Imaging Method for Motility of Left Ventricle in Gated SPECT (게이트 심근 SPECT에서 좌심실의 운동성 분석을 위한 속도영상화 기법 개발)

  • Jo, Mi-Jung;Lee, Byeong-Il;Choi, Hyun-Ju;Hwang, Hae-Gil;Choi, Heung-Kook
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.7
    • /
    • pp.808-817
    • /
    • 2006
  • Although the generally used the velocity index of doppler effect is a very significant factor in the functional evaluation of the left ventricle, it depends on the subjective evaluation of an inspector. The objective data of the motility can be obtained from the gated myocardial SPECT images by quantitative analysis. However, it is difficult to image visual of the velocity of the motion. The aim of our study is to develop a new method for the imaging velocity using the gated myocardial SPECT images and use it as an evaluation index for analyzing motility. First we visualized left ventricle into 3 dimensions using the coordinates of the points which were obtained through a segmentation of myocardium. Each point was represented by the different colors, according to the velocity of each point. We performed a validation study using 7 normal subjects and 15 myocardial infarction patients. To analyze motility, we used the average of the moved distance and the velocity. In normal cases, the average of the moved distance was 4.3mm and the average of the velocity was 11.9mm. In patient cases, the average of the moved distance was 3.9mm and the average of the velocity was 10.5mm. These results show that the motility of normal subjects is higher than the abnormal subjects. We expect that our proposed method could become a way to improve the accuracy and reproducibility for the functional evaluation of myocardial wall.

  • PDF

THE RADIOGRAPHICAL MEASUREMENT OF ROOT CANAL CURVATURE OF MANDIBULAR PRIMARY 2ND MOLARS (하악 제 2 유구치 근관 만곡의 방사선학적 계측)

  • Kim, Young-Jong;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.4
    • /
    • pp.637-642
    • /
    • 2003
  • Morphology of primary root divergency and curvature determines the pattern of root resorption and periapical lesion, and affects successful root canal treatment. With the purpose of analysing the morphology of primary mandibular second molar roots and canals, the frequency, angle, radius, and start of curvature of the canal were measured. Fifty clinical radiographs were taken from $3{\sim}6$ years old children, followed by digitizing after scanning and analyzing by Scion image Beta 4.02TM(Scion Co. USA). The angle of curvature was determined by Schneider's method and the radius of curvature was determined by Schaefer's method. The results were as follows: 1. The angle of curvatures were $17.3^{\circ}{\pm}5.0$ (mesial), and $27.9^{\circ}{\pm}6.0$ (distal). Distal curvature was significantly larger than mesial.(p<0.05) 2. The radius of curvatures were $8.7mm{\pm}2.5$ (mesial), and $5.8\;mm{\pm}1.5$ (distal). Mesial curvature was significantly larger than distal.(p<0.05) 3. The start of curvatures were $4.1mm{\pm}0.6$ (mesial), and $4.2mm{\pm}0.6$ (distal). There were no difference between two groups. (P<0.05)

  • PDF

Optical System Design of Compact Head-Up Display(HUD) using Micro Display (마이크로 디스플레이를 이용한 소형 헤드업 디스플레이 광학계 설계)

  • Han, Dong-Jin;Kim, Hyun-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.6227-6235
    • /
    • 2015
  • The HUD has recently been downsized due to the development of micro display and LED technology as a see through information display device, gradually expands the application areas. In this paper, using a DLP micro display device designed a compact head-up display(HUD) optical system for biocular observation of the image exhibition area 5 inches. It was analyzed for each design element of the optical system in order to design a compacted HUD. DLP, projection optical system and concave image combiner were discussed the design approach and the characteristics. Through a connection structure analysis of each optical system, detailed design specifications were set up and designed the optical system in detail. Put a folded configuration in the form of a white diffuse reflector between the projection lens and concave image combiner was designed to be independent, respectively. Distance of the projected image is adjustable up to approximately 2m ~ infinity and observation distance is 1m. Resolution could be recognized by 1 ~ 2pixels in HD($1,280{\times}720pixels$) class, various characters and symbols could be read. In addition, color navigation map, daytime video camera and thermal imaging cameras can be displayed.

Diagnosis of Location and Size of Lesions using Chest X-ray Image (X-선 영상을 이용한 암의 위치 및 크기 진단)

  • Jung-Min, Son;Byung-Ju, Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.167-173
    • /
    • 2023
  • X-ray general radiography is the simplest and most important one to get a lot of information. Nevertheless, current x-ray general radiography does not observation in-depth observation. Information about the anatomy of the human body and changes in disease in x-ray general radiography can be obtained but it is difficult to determine the size and shape of the actual lesion due to the disadvantage of expanding the image. In this study, PA and LAT images were acquired and cancer magnification was calculated in the images by measuring the distance of cancer samples. By adjusting the magnification the actual cancer length and thickness were measured and compared with the CT image and the actual cancer sample size. After the PA and LAT images of the inserted 6.0 mm cancer sample were obtained and the magnification was corrected, the length was 5.9 mm and the thickness was 6.1 mm. This value was measured similarly to the actual. The problem of obtaining the magnification that needs to know the actual length from the detector to the cancer sample was secured by obtaining the magnification through PA and LAT images and it is possible to accurately measure the cancer sample size. X-ray general radiography may provide useful information in situations where CT imaging is difficult.

A study on evaluation of the image with washed-out artifact after applying scatter limitation correction algorithm in PET/CT exam (PET/CT 검사에서 냉소 인공물 발생 시 산란 제한 보정 알고리즘 적용에 따른 영상 평가)

  • Ko, Hyun-Soo;Ryu, Jae-kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.55-66
    • /
    • 2018
  • Purpose In PET/CT exam, washed-out artifact could occur due to severe motion of the patient and high specific activity, it results in lowering not only qualitative reading but also quantitative analysis. Scatter limitation correction by GE is an algorism to correct washed-out artifact and recover the images in PET scan. The purpose of this study is to measure the threshold of specific activity which can recovers to original uptake values on the image shown with washed-out artifact from phantom experiment and to compare the quantitative analysis of the clinical patient's data before and after correction. Materials and Methods PET and CT images were acquired in having no misalignment(D0) and in 1, 2, 3, 4 cm distance of misalignment(D1, D2, D3, D4) respectively, with 20 steps of each specific activity from 20 to 20,000 kBq/ml on $^{68}Ge$ cylinder phantom. Also, we measured the distance of misalignment of foley catheter line between CT and PET images, the specific activity which makes washed-out artifact, $SUV_{mean}$ of muscle in artifact slice and $SUV_{max}$ of lesion in artifact slice and $SUV_{max}$ of the other lesion out of artifact slice before and after correction respectively from 34 patients who underwent $^{18}F-FDG$ Fusion Whole Body PET/CT exam. SPSS 21 was used to analyze the difference in the SUV between before and after scatter limitation correction by paired t-test. Results In phantom experiment, $SUV_{mean}$ of $^{68}Ge$ cylinder decreased as specific activity of $^{18}F$ increased. $SUV_{mean}$ more and more decreased as the distance of misalignment between CT and PET more increased. On the other hand, the effect of correction increased as the distance more increased. From phantom experiments, there was no washed-out artifact below 50 kBq/ml and $SUV_{mean}$ was same from origin. On D0 and D1, $SUV_{mean}$ recovered to origin(0.95) below 120 kBq/ml when applying scatter limitation correction. On D2 and D3, $SUV_{mean}$ recovered to origin below 100 kBq/ml. On D4, $SUV_{mean}$ recovered to origin below 80 kBq/ml. From 34 clinical patient's data, the average distance of misalignment was 2.02 cm and the average specific activity which makes washed-out artifact was 490.15 kBq/ml. The average $SUV_{mean}$ of muscles and the average $SUV_{max}$ of lesions in artifact slice before and after the correction show a significant difference according to a paired t-test respectively(t=-13.805, p=0.000)(t=-2.851, p=0.012), but the average $SUV_{max}$ of lesions out of artifact slice show a no significant difference (t=-1.173, p=0.250). Conclusion Scatter limitation correction algorism by GE PET/CT scanner helps to correct washed-out artifact from motion of a patient or high specific activity and to recover the PET images. When we read the image occurred with washed-out artifact by measuring the distance of misalignment between CT and PET image, specific activity after applying scatter limitation algorism, we can analyze the images more accurately without repeating scan.

Analysis of the Spatial Dose Rates during Dental Panoramic Radiography (치과 파노라마 촬영에서 공간선량률 분석)

  • Ko, Jong-Kyung;Park, Myeong-Hwan;Kim, Yongmin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.509-516
    • /
    • 2016
  • A dental panoramic radiography which usually uses low level X-rays is subject to the Nuclear Safety Act when it is installed for the purpose of education. This paper measures radiation dose and spatial dose rate by usage and thereby aims to verify the effectiveness of radiation safety equipment and provide basic information for radiation safety of radiation workers and students. After glass dosimeter (GD-352M) is attached to direct exposure area, the teeth, and indirect exposure area, the eye lens and the thyroid, on the dental radiography head phantom, these exposure areas are measured. Then, after dividing the horizontal into a $45^{\circ}$, it is separated into seven directions which all includes 30, 60, 90, 120 cm distance. The paper shows that the spatial dose rate is the highest at 30 cm and declines as the distance increases. At 30 cm, the spatial dose rate around the starting area of rotation is $3,840{\mu}Sv/h$, which is four times higher than the lowest level $778{\mu}Sv/h$. Furthermore, the spatial dose rate was $408{\mu}Sv/h$ on average at the distance of 60 cm where radiation workers can be located. From a conservative point of view, It is possible to avoid needless exposure to radiation for the purpose of education. However, in case that an unintended exposure to radiation happens within a radiation controlled area, it is still necessary to educate radiation safety. But according to the current Medical Service Act, in medical institutions, even if they are not installed, the equipment such as interlock are obliged by the Nuclear Safety Law, considering that the spatial dose rate of the educational dental panoramic radiography room is low. It seems to be excessive regulation.