• Title/Summary/Keyword: 파절

Search Result 577, Processing Time 0.023 seconds

AN EXPERIMENTAL STUDY ON THE FRACTURE STRENGTH OF CLASS II POSTERIOR RESTORATIONS (II급 와동에서 각종 구치용 수복물의 파절강도에 관한 실험적 연구)

  • Lee, Kye-Hyuck;Hur, Seung-Myun;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.357-367
    • /
    • 1993
  • The purpose of this study was to evaluate the fracture strength of class II restored premolars with amalgam, posterior composite, amalgam - Ketac silver, resin - Ketac silver restorations at marginal ridge. Fifty extacted maxillary and mandibular premolar teeth that were caries free, fracture free, and restoration free were selected and randomly divided into five groups : Group 1 : 10 intact teeth, Group 2 : 10 teeth with class II cavities and restored with, amalgam, Group 3: 10 teeth with class II cavities and restored with posterior resin, Group 4 : 10 teeth with class II cavities and restored with amalgam - ketac silver, Group 5 : 10 teeth with class II cavities and restored with resin - Ketac silver. All teeth were mounted in base of dental stone within metal rings of 2cm diameter, exposing only the crown portion. Class II mesio - occlusal or disto - occlusal cavities were prepared into specimens of Group 2 through 5 by using a No. 710 fissure bur. The occlusal portion was prepared to a faciolingual width of 1.5mm and a pulpal depth of 1.5mm. The proximal protion was prepared to a faciolingual width of 4mm, a occlusogingival height of 4mm, and a gingival floor of 1.5mm. The teeth in Group 2 and 3 were resotored with silver amalgam apd posterior resin respectively. In Group 4 and 5, proximal portions were first filled with Ketac silver 1.5mm gingivally and remaining cavities were restored with amalgam and posterior resin respectively. All specimens were stored in 100 % relative humidity at $37^{\circ}C$ for 48 hours before testing. All teeth were subjected to a compressive load in a Universal Instron Testing Machine at marginal ridges. The loads required to fracture the restorations were recorded in killograms and the data obtained were subjected to statisticall analysis. The results were all follows : 1. The fracture strength of Group 1 which were unprepared were $100{\pm}10.1\;kg$ and the higher values than Group 2, 3, 4, 5 which were prepared and resotred. 2. In restored groups, Group 2 had the higher fracture strength($81.8{\pm}12.4\;kg$) than other groups and Group 4 had the lowest fracture strength($66.8{\pm}9.2kg$). 3. There were significant differences between fracture strength of between Group 1 and Group 3, 4, 5(P<0.05), but not significant difference between fracture strength of Group 2, 3, 4, 5(P>0.05).

  • PDF

A STUDY ON TOOTH FRACTURE WITH THREE DIMENSIONAL FINITE ELEMENT METHOD (치아파절에 관한 3차원유한요소법적 연구)

  • Cho, Byeong-Hoon;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.291-316
    • /
    • 1993
  • Restorative procedures can lead to tooth fracture due to the relatively small amount of the remaining tooth structure. It is essential to prevent fractures by having a clear concept of the designs for cavity preparations. Among the several parameters in cavity designs, profound understanding of isthmus width factor would facilitate selection of the appropriate cavity preparation for a specific clinical situation. In this study, MO amalgam cavity were prepared on maxillary first premolar and filled with amalgam. Three dimensional, model with 1365 8-node brick elements was made by serial photographic method. In this model, isthmus was varied in width at 1/4, 1/3, 1/2 and 2/3 of intercuspal width and material properties were given for three element groups, i.e., enamel, dentin and amalgam. A load of 500 N was applied vertically on amalgam and enamel. In case of enamel loading, 2 model (with and without amalgam) was compared to consider the possibility of play at the interface between tooth material and amalgam. These models were analyzed with three dimensional finite element method. The results were as follows: 1. The stress was concentrated on the facio-pulpal line angle and distal marginal ridge of the cavity. 2. With the increase of the isthmus width, the stress spread around the facio-pulpal line angle and the area of stress concentration moved toward the proximal box. 3. In case of narrow isthmus width, the initiation point of crack would be in the area of isthmus corner of the cavity, and with the increase of the isthmus width, it would move toward the proximal box and at the same time the possibility of crack increase at the distal marginal ridge. 4. The direction of crack progressed outward and downward from the facio-pulpal line angle, and with the increase of the isthmus width, it approximated vertical direction. At the marginal ridge, it occurred in vertical direction. 5. It would be favorable to make the isthmus width narrower than a third of the intercuspal width, and to cover the cusp if isthmus width were wider than half of the intercuspal width. 6. It is necessary to apply the possibility of play to the finite element analysis.

  • PDF

A STUDY ON FRACTURE STRENGTH OF COLLARLESS METAL CERAMIC CROWN WITH DIFFERENT METAL COPING DESIGN (금속코핑 설계에 따른 Collarless Metal Ceramic Crown의 파절강도에 관한 연구)

  • Yun, Jong-Wook;Yang, Jae-Ho;Chang, Ik-Tae;Lee, Sun-Hyung;Chung, Hun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.454-464
    • /
    • 1999
  • The metal ceramic crown is currently the most popular complete veneer restoration in dentistry, but in many cases, the metal cervical collar at the facial margin is unesthetic and unacceptable. Facial porcelain margin has been used in place of it. But this dose not solve the problems, such as dark gingival discoloration and cervical opaque reflection of porcelain veneer. Recently, metal copings which were designed to terminate its labio-cervical end on the axial walls coronal to the shoulder have been clinically used to solve the esthetic problem of metal ceramic crown. But in this design, porcelain veneer of labio-cervical area which is not supported by metal may not be able to resist the stress during cementation and mastication. The purpose of this study was to evaluate fracture strength and fractured appearance of crowns according to different coping designs. A resin maxillary left central incisor analogue was prepared for a metal ceramic crown, and metal dies were made with duplication mold. Metal copings were made and assigned to one of four groups based on facial framework designs: group 1, coping with 0.5mm metal collar; group 2, metal extended to the shoulder; group 3, metal extended to 1mm coronal tn the shoulder: group 4, metal extended to 2mm coronal to the shoulder. Copings and crowns were adjusted to be same size and thickness, and cemented to metal dies with zinc phosphate cement by finger pressure. Fracture strength was measured with Instron Universal Testing Machine. Metal dies were anchored in Three-way-vice at 3mm below finish line and at $130^{\circ}$ inclined to the long axis of the crown. Load was directed lingually at 2mm below midincisal edge. Load value at initial crack and at catastrophic fracture was recorded. The results obtained were as follows : 1. Fracture strength values at initial crack were higher in groups 1, 2 than in groups 3, 4 but this difference was not statistically significant(P<0.05). 2. Conventional metal collared crown had greater catastrophic fracture strength than any other collarless crowns. 3. The greater the labial metal coping reduction, the lower the catastrophic fracture strength of crowns but when more than 1mm of labial metal reduction was done, the difference in strengths was not statistically significant(p<0.05). 4. The strongest collarless coping design was group 2.

  • PDF

Three-dimensional finite element analysis for influence of marginal bone resorption on stress distribution in internal conical joint type implant fixture (변연골 흡수가 내측연결 임플란트 매식체의 응력분포에 미치는 영향)

  • Yun, Mi-Jung;Yoon, Min-Chul;Eom, Tae-Gwan;Huh, Jung-Bo;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.99-105
    • /
    • 2012
  • Purpose: The change of the marginal bone around dental implants have significance not only for the functional maintenance but also for the esthetic success of the implant. The purpose of this study was to investigate the load transfer of internal conical joint type implant according to marginal bone resorption by using the three-dimensional finite element analysis model. Materials and methods: The internal conical joint type system was selected as an experimental model. Finite element models of bone/implant/prosthesis complex were constructed. A load of 300 N was applied vertically beside 3 mm of implant axis. Results: The pattern of stress distribution according to marginal bone resorption was similar. The maximum equivalent stress of implant was increase according to marginal bone resorption and the largest maximum equivalent stress was shown at model of 1 mm marginal bone resorption. Although marginal bone loss more than 1mm was occurred increasing of stress, the width of the stress increase was decreasing. Conclusion: According to these results, the exposure of thin neck portion of internal conical joint type implant is most important factor in stress increasing.

BUBBLE BEHAVIOR OF PIT AND FISSURE SEALANT (치면열구전색제의 도포 시 전색제에 따른 기포 발생 양태)

  • Kim, Hyun-Jin;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.1
    • /
    • pp.99-105
    • /
    • 2007
  • In clinical practice, air bubbles trapped in the pit and fissure may increase early loss of sealing materials for fracture, wear and microleakage. The purpose of this investigation was to examine the bubble behavior of pit and fissure sealant. The 140 replicas made of epoxy resin were used to this experiment. Following conditioning, light-polymerized sealants were applied and then exposed to the light source. After stereoscopic examination of standarized specimen by grinding, bubble behavior was analysed. The results obtained were as follows; 1. Ultraseal $XT^{(R)}$ plus grops irrespective of using time were higher than groups of $Helioseal^{(R)}$ with clinpro tip and metal tip in the frequency of bubble(p<0.05), 2. Ultraseal $XT^{(R)}$ plus old group was more than $Clinpro^{(R)}$, Teethmate $F-l^{(R)}$ and $Helioseal^{(R)}$ with brush tip in the number of bubble under 200 magnified cross section(p<0.05). 3. The widest mean area of bubble was shown in the Teethmate $F-1^{(R)}$. 4. No statistically significant difference of the frequency and the site of bubble between $Clinpro^{(R)}$ and $Helioseal^{(R)}$ groups(p>0.05).

  • PDF

AUTOTRANSPLANTATION OF TOOTH WITH IMMATURE ROOT FORMATION (치근단 미완성 치아의 자가치아이식)

  • Jung, Ji-Sook;Park, Ho-Won;Lee, Ju-Hyun;Seo, Hyun-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.1
    • /
    • pp.66-72
    • /
    • 2012
  • Autogenous tooth transplantation can be defined as the surgical movement of a tooth from one position in the mouth to another in the same individual. The most common reasons for tooth transplantation include replacement of a missing first molar, transplantation of impacted canines to their normal positions in the arch, and transplantation of premolars in areas of missing teeth, especially in the anterior area of the mouth. The key to successful tooth transplantation is proper selection of graft with adequate root development as well as the design of surgical operation. Root development stage with half to three-quarter-developed roots increase the success rate of autotransplantation. We report the cases of successful autotransplantation which resulted in ideal healing of periodontal ligament, gingiva and alveolar bone. All transplanted teeth presented immature root formation at the moment of the procedure. After surgical procedure, we can observe good healing pattern without endodontic problem.

A STUDY ON THE TRAUMATIC INJURIES TO PRIMARY TEETH (유치 외상에 관한 연구)

  • Chung, Youn-Joo;Kim, Kwang-Chul;Park, Jae-Hong;Choi, Sung-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.3
    • /
    • pp.328-337
    • /
    • 2010
  • The purpose of this study was to research the traumatized primary teeth and investigate following factors: sex, age, cause, place and time(of the year) of injury, elapsed time, area and type of injury, dental treatment and prognosis. The analysis includes total of 1533 traumatized primary teeth from 758 children aging from 6 months to 6 years(mean age: 2.8) from 2003 to 2007. The result follows : 1. The children of age between 1-2 and 2-3 were involved in the largest number of injuries in both sexes with boy/girl ratio of 1.77:1(p<0.001). 2. Fall and collision were the main causes of traumatic dental injury, especially in younger children(p<0.05). Places of injury occurrence varied: home, outdoors, and kindergarten. Warm climate accounts for frequent outdoor injuries in May, September and October(p<0.001). 3. Most of the children visited dental clinic within 24 hours of the injury(77.6%). From March to September, dental trauma occurrences were distributed evenly, except for Winter period(p<0.001). 4. Upper central incisors were the most commonly affected teeth, and the injuries usually involved 1 tooth or 2 teeth. 5. Periodontal tissue injuries dominated and subluxation was the most common type. Lateral luxation, enamel fracture, intrusion and root fracture followed.

A STUDY OF MICROLEAKAGE AND PENETRATION ABILITY OF A PIT AND FISSURE SEALANT APPLIED ON CARIOUS FISSURES (우식성 열구에 적용한 치면열구전색제의 미세누출과 침투도에 관한 연구)

  • Im, El;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.3
    • /
    • pp.345-351
    • /
    • 2010
  • The purpose of this study is to compare microleakage and penetration depths of sealants applied in carious and sound fissures. Extracted premolars(n=80) were divided into 4 groups according to caries status. 1; sound, 2; stained, 3; initial caries, 4; enamel caries. Sealants were applied to the occlusal groove as per manufacturers' instructions, and specimens were thermocycled, stained, sectioned, and examined for microleakage and penetration ability. The results of the present study are as follow: 1. It showed significantly higher microleakage scores in group I than group Two, Three, Four(p<0.05), but no significant difference was found between group Two, Three, and IV(p>0.05). 2. It showed significantly higher penetration scores in group Four (p<0.05), followed by group One, Two, Three, but no significant difference was found between group One, Two, and Three(p>0.05). Based on the results of present study, when the borders of the fissure sealant are on carious enamel, a significantly higher microleakage must be expected. It is considered that depth of enamel caries in the fissure should be taken into account when applying a fissure sealant.

Marginal Fidelity and Fracture Strength of OPTIMAL PRESSABLE CERAMIC Crown according to Margin Types (OPTIMAL PRESSABLE CERAMIC 금관의 변연형태에 따른 변연적합도와 파절강도에 관한 연구)

  • Lee, Ju-Seog;Kim, Ki-Suk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.1
    • /
    • pp.13-25
    • /
    • 2000
  • Optimal Pressable Ceramic is one of the all-ceramic restorations with a shaded translucent pressed core and layering porcelains. The purpose of this study was to evaluate the marginal fidelity according to margin types and measurement sites, and to evaluate fracture strength according to margin types. Twenty seven OPC crowns made according to 3 types of cervical finishing lines were used in this study. Marginal gaps were measured before and after cementation. A Steromicroscope(SZ-ST(R), Olympus, Japan) was used to measure the space between the margin of OPC crown and the finishing line of metal model. Marginal gaps were measured at the labial, mesial, lingual and distal site, which were demonstrated in advance. Fracture strength testing was carried out using an Instron(Model M100EC, Mecmesin, England) at a cross head speed of 5 mm/min. All crowns were loaded until catastrophic failures occurred. The result were as follow: 1. In comparison according to variable margin before cementation, the marginal gap were increased in chamfer margin($47.50{\pm}18.39{\mu}m$), $120^{\circ}$shoulder margin ($55.21{\pm}14.4{\mu}m$) and $90^{\circ}$shoulder margin($71.18{\pm}13.30{\mu}m$) in ascending order, and there were significant differences between chamfer margin and $90^{\circ}$shoulder margin, $120^{\circ}$shoulder margin and between $120^{\circ}$shoulder margin and $90^{\circ}$shoulder margin respectively(p<0.05). 2. In comparison according to variable margin after cementation, the gap discrepancies were increased in chamfer margin($60.78{\pm}30.37{\mu}m$), $120^{\circ}$shoulder margin($66.67{\pm}11.18{\mu}m$) and $90^{\circ}$shoulder margin($85.78{\pm}17.23{\mu}m$) in ascending order, but there was significant difference only between chamfer margin and $90^{\circ}$shoulder margin(p<0.05). 3. Labio-lingual points showed a better marginal fidelity than that of proximal point(p<0.05). 4. Chamfer margin($48.76{\pm}8.45kgf$) showed higher fracture strength than $120^{\circ}$ shoulder margin($40.57{\pm}7.90kgf$) and $90^{\circ}$ shoulder margin(32.7.90kgf) (p<0.05), but there was significant difference only between chamfer margin and $90^{\circ}$ shoulder margin(p<0.05).

  • PDF

A Literature Review on Implant Assisted Removable Partial Denture (임플란트를 이용한 국소의치에 관한 문헌고찰)

  • Lee, Ji-Hye;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.179-190
    • /
    • 2012
  • The installation of an implant in the distal extension area to assist a partial dentrue (IARPD) was used carefully in clinical situations. The purpose of this review on the IARPD is describing the concept, clinical results and guidelines of IARPD. For the review, a literature search was performed using the PubMed. The data from the literature suggest that the placement of the implants could improve function and patient satisfaction. In addition, IARPD reduced the residual ridge resorption. Longer and wider implant should be placed. Less than $15^{\circ}$ angulation may be not harmful. To prevent the loosening of the abutment, modified abutment or resilient attachment should be used. However, the connection method between the clasp retention and IARPD should be considered for long time success. Moreover, longitudinal clinical studies are required for evaluation of IARPD.