• Title/Summary/Keyword: 파절

Search Result 575, Processing Time 0.025 seconds

Literature review on fractography of dental ceramics (치과용 세라믹의 파단면분석(fractography)에 대한 문헌고찰)

  • Song, Min-Gyu;Cha, Min-Sang;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.3
    • /
    • pp.138-149
    • /
    • 2022
  • The clinical applicability of ceramics can be increased by analyzing the causes of fractures after fracture testing of dental ceramics. Fractography to analyze the cause of fracture of dental ceramics is being widely applied with the development of imaging technologies such as scanning electron microscopy. Setting the experimental conditions is important for accurate interpretation. The fractured specimens should be stored and cleaned to avoid contamination, and metal pretreatment is required for better observation. Depending on the type of fracture, there are dimple rupture, cleavage, and decohesive rupture mainly observed in metals, and fatigue fractures and conchoidal fractures observed in ceramics. In order to reproduce fatigue fracture in the laboratory, which is the main cause of fracture of ceramics, a dynamic loading for observing slow crack growth is essential, and the load conditions and number of loads must be appropriately set. A typical characteristic of a fracture surface of ceramic is a hackle, and the causes of fracture vary depending on the shape of hackle. Fractography is a useful method for in-depth understanding of fractures of dental ceramics, so it is necessary to follow the exact experimental procedure and interpret the results with caution.

CONSERVATIVE APPROACH ON THE SEVERELY DISPLACED ROOT FRACTURE OF PRIMARY INCISORS : CASE REPORT (심하게 변위된 유전치 치근파절의 보존적 접근)

  • Kim, Jee-Young;Lee, Kwang-Hee;Kim, Dae-Eop;Ra, Ji-Young;Lee, Dong-Jin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.3
    • /
    • pp.571-577
    • /
    • 2008
  • Root fracture of primary teeth is relatively uncommon because the more pliable alveolar bone allows displacement of the tooth. Root fracture of primary teeth is occupied $2{\sim}7%$ in trauma pattern of primary teeth. A horizontal root fracture is classified based on the location of the fracture in relation to the root tip : the apical third, middle third, or cervical third of the root. The prognosis worsens the further cervically the fracture has occurrer. Root fracture of primary teeth should be treated by splinting the incisor to the adjacent normal teeth with a resin-wire splint for $8{\sim}12$ weeks. However, if a portion of the root is abscessed or extremely mobile, it can be extracted, and the remaining root fragment will resorb normally. For coronal third fracture in primary teeth, the coronal third is extracted, leaving the apical portion of the root to resorb normally. These root fracture cases of primary teeth were treated by resin-wire splinting despite extremely mobile coronal fragment. Even though they seems like healing well, They need to be monitored regularly until their successors erupt.

  • PDF

INTENTIONAL REPLANTATION OF THE CROWN-ROOT FRACTURED TOOTH: A CASE REPORT (치관-치근 파절된 치아의 의도적 재식술 치험례)

  • Kim, Soo-Kyoung;Ahn, Seung-Tae;Choi, Sung-Chul;Kim, Kwang-Chul;Park, Jae-Hong
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.3
    • /
    • pp.381-386
    • /
    • 2010
  • As the vertical fracture occurs at the various locations following the long axis of a root, treatment method of crown-root fractured anterior teeth is decided according to the depth. If the fracture line is close to the crown, gingivectomy, orthodontic - forced eruption or surgical extrusion of apical fragment could be done. If the line is over 1/3 length of the root, the prognosis is poor and extraction is usually undertaken. However, extraction of maxillary incisor at growing children causes many complications such as esthetic, phonetic problem and alveolar bone resorption. Therefore, preservation of tooth is the highest priority. Recently, intentional replantation with composite resin could be considered as alternative treatment of crown-root fractured anterior tooth. This report presents a patient in mixed dentition with deep vertical crown-root fracture of the maxillary permanent central incisors by trauma. Intentional replantation of the fractured teeth was performed using composite resin. After 2 years, specific clinical symptom has not been found and the patient was satisfied of esthetic result. This method suggests the new technique to preserve a tooth as an alternative to extraction, although it is technically sensitive and the reports of long-term prognosis is insufficient.

TREATMENT OF CROWN-ROOT FRACTURE BY INTENTIONAL REPLANTATION : CASE REPORT (의도적 재식술을 이용한 치관-치근 파절의 치험례)

  • Son, Ju-Hyo;Choi, Hyung-Jun;Sohn, Heung-Kyu
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.2
    • /
    • pp.256-261
    • /
    • 2000
  • Trauma to the tooth is the most common accidents in pediatric dentistry and tooth fracture occurs frequently. Fracture is classified into crown fracture, root fracture, and crown-root fracture which involves both. Also, it is classified into simple or complicated fracture depending on whether the pulp is exposed or not. When the fracture is extended down to the subgingival level following the long axis of the root, or when more than 1/3 of the root is involved, extraction is the primary treatment. But alternative treatment such as extruding the root fragment with orthodontic force and restoring it, or intentionally extracting the tooth and replanting it to a position which it can be restored. This is a case report on intentional replantation of a traumatized maxillary central incisor with crown-root fracture of a patient with mixed dentition. The teeth was extracted and immediate endodontic treatment, retrograde filling and resin restoration were carried out.

  • PDF

MANAGEMENT OF SEPARATED FILE IN THE ROOT CANAL (근관 내 File의 파절 시 대처 방안)

  • Kim, Hye-Jeong;Jang, Hoon-Sang;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.3
    • /
    • pp.161-168
    • /
    • 2006
  • During root canal preparation procedures, the potential for instrument separation is always present. Files, a lentulo, a Gates-Glidden (GG) bur or any manufactured obstruction can be left behind in the canal Nickel-titanium (NiTi) rotary files are in common usage in these days. Despite their undeniable advantages, there is a potential risk of separation within the canals. It is very rapid, unpredictable, and creates a great deal of stress for the practitioner. When an endodontic instrument separates, the best option is to remove it. Ultrasonic instruments and microscopes have improved the success rate for removing separated instruments. But It is difficult and not always possible. Therefore prevention is the key. In this case report, several management methods of separated file in the canal are presented.

Effect of location of glass fiber pre-impregnated with light-curing resin on the fracture strength and fracture modes of a maxillary complete denture (광중합형 레진에 함침시킨 유리섬유의 위치가 상악 총의치의 파절강도와 파절양상에 미치는 영향)

  • Yoo, Hyun-Sang;Sung, Su-Jin;Jo, Jae-Young;Lee, Do-Chan;Huh, Jung-Bo;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.279-284
    • /
    • 2012
  • Purpose: This study evaluated the effect of glass fiber pre-impregnated with light-curing resin on the fracture strength and fracture modes of a maxillary complete denture. Materials and methods: Maxillary acrylic resin complete dentures reinforced with glass fiber pre-impregnated with light-curing resin (SES MESH, INNO Dental Co., Yeoncheongun, Korea) and without reinforcement were tested. The reinforcing material was embedded in the denture base resin and placed different regions (Control, without reinforcement; Group A, center of anterior ridge; Group B, rugae area; Group C, center of palate; Group D, full coverage of denture base). The fracture strength and fracture modes of a maxillary complete denture were tested using Instron test machine (Instron Co., Canton, MA, USA) at a 5.0 mm/min crosshead speed. The flexure load was applied to center of denture with a 20 mm diameter ball attachment. When fracture occurred, the fracture mode was classified based on fracture lines. The data were analyzed with one-way ANOVA at the significance level of 0.05. Results: There were non-significant differences (P>.05) in the fracture strength among test groups. Group A showed anteroposterior fracture and posterior fracture mainly, group B, C and control group showed partial fracture on center area mostly. Most specimen of group D showed posterior fracture. Conclusion: The location and presence of the fiber reinforcement did not affect the fracture strength of maxillary complete denture. However, reinforcing acrylic resin denture with glass fiber has a tendency to suppress the crack.

Management of peri-implantitis associated with tear-like implant fracture: case reports (열리형 임플란트 파절과 연관된 임플란트 주위염의 관리: 증례 보고)

  • Kim, Yeon-Tae;Lee, Jae-Hong;Jeong, Seong-Nyum
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.138-144
    • /
    • 2020
  • Implant fracture is rare, but one of the most serious problem in implantation. Treatment of implant fracture can be different according to the extent of the fracture and on the state of the surrounding prosthetic restoration. Maintaining or submerging implant after treatment of peri-implantitis can be useful options for cases of tear-like fracture on the coronal area of an implant.

HEALING OF HORIZONTAL ROOT FRACTURE : TWO CLINICAL CASES (수평치근파절의 두 가지 치험례)

  • Ki-Ok Kim;Sung-Kyo Kim
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.5
    • /
    • pp.443-446
    • /
    • 2001
  • 급격한 치아외상은 치아 경조직에 손상을 주기도 하지만 치수와 치주조직에도 손상을 입힌다. 탈구(luxation)의 경우, 외상에 의해 치근단공 부위에서 신경혈관계의 파괴가 초래되지만 치근파절의 경우에는 파절전 부위에서 이와 유사한 손상이 나타난다. 그러므로 치근파절을 파절선 상부의 치관부에 대한 일종의 탈구로 보기도 한다. 본 증례보고는 외상에 의한 치근파절의 두 가지 치유양상을 비교한 것으로, 한 증례는 특정한 치과적 처치없이 스스로 치유된 경우이고 다른 한 증례는 치아고정 및 근관치료를 포함한 치과치료후에 치유된 경우이다. 수평치근파절의 치유에는 여러 가지 요인이 관여하지만 특히 치아동요도 및 치수생활력이 큰 영향을 미친다. 본 증례에서와 같이 치아의 동요도가 있는 경우에는 고정을 통해서 치유를 촉진하고 치수의 괴사가 초래된 경우에는 근관치료를 포함한 적절한 치과치료를 통해서 치유가 일어날 수 있다. 따라서 치근이 파절된 경우에는 장기간의 관찰을 통해 파절부 치유 및 치수손상 여부를 관찰, 진단하고 그에 따른 적절한 처치를 시행해야 할 것이다.

  • PDF

Comparison of fatigue fracture strength by fixture diameter of mini implants (미니 임플란트 직경에 따른 피로파절강도의 비교 연구)

  • Heo, Yu-Ri;Son, Mee-Kyoung;Kim, Hee-Jung;Choe, Han-Cheol;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.156-161
    • /
    • 2012
  • Purpose: This study was conducted to obtain difference in fracture strength according to the diameter of one-body O-ring-type of mini implant fixture, to determine the resistance of mini implant to masticatory pressure, and to examine whether overdenture using O-ring type mini implant is clinically usable to maxillary and mandibular edentulous patients. Materials and methods: For this study, 13 mm long one body O-ring-type mini implants of different diameters (2.0 mm, 2.5 mm and 3.0 mm) (Dentis, Daegu, Korea) were prepared, 5 for each diameter. The sample was placed at $30^{\circ}$ from the horizontal surface on the universal testing machine, and off-axis loading was applied until permanent deformation occurred and the load was taken as maximum compressive strength. The mean value of the 5 samples was calculated, and the compressive strength of implant fixture was compared according to diameter. In addition, we prepared 3 samples for each diameter, and applied loading equal to 80%, 60% and 40% of the compressive strength until fracture occurred. Then, we measured the cycle number on fracture and analyzed fatigue fracture for each diameter. Additionally, we measured the cycle number on fracture that occurred when a load of 43 N, which is the average masticatory force of complete denture, was applied. The difference on compressive strength between each group was tested statistically using one-way ANOVA test. Results: Compressive strength according to the diameter of mini implant was $101.5{\pm}14.6N$, $149{\pm}6.1N$ and $276.0{\pm}13.4N$, respectively, for diameters 2.0 mm, 2.5 mm and 3.0 mm. In the results of fatigue fracture test at 43 N, fracture did not occur until $2{\times}10^6$ cycles at diameter 2.0 mm, and until $5{\times}10^6$ cycles at 2.5 mm and 3.0 mm. Conclusion: Compressive strength increased significantly with increasing diameter of mini implant. In the results of fatigue fracture test conducted under the average masticatory force of complete denture, fracture did not occur at any of the three diameters. All of the three diameters are usable for supporting overdenture in maxillary and mandibular edentulous patients, but considering that the highest masticatory force of complete denture is 157 N, caution should be used in case diameter 2.0 mm or 2.5 mm is used.

The Effect of Surface Defects on the Cyclic Fatigue Fracture of HEROShaper Ni-Ti rotary files in a Dynamic Model: A Fractographic Analysis (Fractographic 분석을 통한 HEROShaper 니켈티타늄 전동 파일의 피로파절에 미치는 표면결함의 역할)

  • Lee, Jung-Kyu;Kim, Eui-Sung;Kang, Myoung-Whai;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.2
    • /
    • pp.130-137
    • /
    • 2007
  • This in vitro study examined the effect of surface defects on cutting blades on the extent of the cyclic fatigue fracture of HEROShaper Ni-Ti rotary files using fractographic analysis of the fractured surfaces. A total of 45 HEROShaper (MicroMega) Ni-Ti rotary flies with a #30/.04 taper were divided into three groups of 15 each. Group 1 contained new HEROShapers without any surface defects. Group 2 contained HEROShapers with manufacturing defects such as metal rollover and machining marks. Croup 3 contained HEROShapers that had been clinically used for the canal preparation of 4-6 molars A fatigue-testing device was designed to allow cyclic tension and compressive stress on the tip of the instrument whilst maintaining similar conditions to those experienced in a clinic. The level of fatigue fracture time was measured using a computer connected the system. Statistical analysis was performed using a Tukey's test. Scanning electron microscopy (SEM) was used for fractographic analysis of the fractured surfaces. The fatigue fracture time between groups 1 and 2, and between groups 1 and 3 was significantly different (p<0.05) but there was no significant difference between groups 2 and 3 (p>0.05). A low magnification SEM views show brittle fracture as the main initial failure mode At higher magnification, the brittle fracture region showed clusters of fatigue striations and a large number of secondary cracks. These fractures typically led to a central region of catastrophic ductile failure. Qualitatively, the ductile fracture region was characterized by the formation of microvoids and dimpling. The fractured surfaces of the HEROShapers in groups 2 and 3 were always associated with pre-existing surface defects. Typically, the fractured surface in the brittle fracture region showed evidence of cleavage (transgranular) facets across the grains, as well as intergranular facets along the grain boundaries. These results show that surface defects on cutting blades of Ni-Ti rotary files might be the preferred sites for the origin of fatigue fracture under experimental conditions. Furthermore this work demonstrates the utility of fractography in evaluating the failure of Ni-Ti rotary flies.