• Title/Summary/Keyword: 파이프 설치

Search Result 156, Processing Time 0.027 seconds

Experimental Study on Improvement of Pipe-rack Joint (Pipe-rack접합부 개선방법에 관한 실험적 연구)

  • Lee, Jong-Kun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.1-9
    • /
    • 2018
  • The development of new technology and process in industrial Plant which builds integrated structures, facilities and systems. Has become a key element for strengthening its competitiveness. Although domestic industrial Plant has demonstrated excellence in technology with a persistent increase in order quantity and orders received, the technology gap between countries has narrowed due to global construction trend. Therefore, it is necessary to develop new technology that could help overcome constraints and limitations of the current one to follow the trend in the age of unlimited competition. This study has focused on assembly technology of Pipe-rack joint connection in an effort to strengthen technological competitiveness in industrial Plant. Through an analysis of earlier studies on Pipe-rack and a coMParative analysis of strengths and weaknesses of current assembly technology of it, a new design plan has been made to improve it efficiently. In doing this, standards for design factors of both structural and performance features have been drawn, and value of stress, strain, moment and rotation has been calculated using finite element analysis. As a result, installation technology of modular type Pipe-rack, which has not been developed in Korea and is differentiated from the current one, has been developed. It is considered that the technology reduces work time and saves cost due to simplified joint connection of steel structure, unlike the current one. Moreover, since it is installed without a welding process in the field, industrial accidents would be reduced, which is likely to have economic competitiveness and satisfy.

Seismic Performance and Damage Prediction of Existing Fire-protection Pipe Systems Installed in RC Frame Structures (철근콘크리트 구조물 내 부착된 수계 관망시스템의 내진거동 및 손상예측)

  • Jung, Woo-Young;Ju, Bu-Seog
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.3
    • /
    • pp.37-43
    • /
    • 2011
  • Reliability of piping systems is essential to the safety of any important industrial facilities. During an earthquake, damage to the piping system can occur. It can also cause considerable economic losses and the loss of life following earthquakes. Traditionally, the study of the secondary system was less important than primary structure system, however it has recently been emerging as a key issue for the effective maintenance of the structural system and to help reduce nonstructural earthquake damage. The primary objectives of this study are to evaluate seismic design requirements and the seismic performance of gas and fire protection piping systems installed in reinforced concrete (RC) buildings. In order to characterize the seismic behavior of the existing piping system in an official building, 10 simulated earthquakes and 9 recorded real earthquakes were applied to ground level and the building system by the newmark average acceleration time history method. The results developed by this research can be used for the improvement of new seismic code/regulatory guidelines of secondary systems as well as the improvement of seismic retrofitting or the strengthening of the current piping system.

A Study of Structural Stability of HDPE Pipe during Installation (고밀도 폴리에틸렌 파이프의 설치중 구조안정성에 대한 연구)

  • Song, Hyun-Bae;Kim, Do-Kyun;Choi, Han-Suk;Park, Kyu-Sik
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.1
    • /
    • pp.59-66
    • /
    • 2015
  • In this study, structural stability of large diameter high density polyethylene (HDPE) pipe during installation was numerically investigated in order to investigate the effect of concrete collar dimension, water depth and tension (pulling force). From the numerical simulation results, the total stress of HDPE pipe with designed concrete collar was within 2.5%, so the total weight of concrete collar for sinking of HDPE is important rather than concrete collar dimension. Furthermore, the tension area for possible installation is decreased as the air filling rate is increased. Therefore, it is important to calculate the reasonable tension range before actual installation for safe installation of HDPE pipe.

The Optimal pipelining architecture for PICAM (PICAM에서의 최적 파이프라인 구조)

  • 안희일;조태원
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.6A
    • /
    • pp.1107-1116
    • /
    • 2001
  • 고속 IP 주소 룩업(lookup)은 고속 인터넷 라우터의 성능을 좌우하는 주요 요소이다. LPM(longest prefix matching) 탐색은 IP 주소 룩업에서 가장 시간이 많이 걸리는 부분이다. PICAM은 고속 LPM 탐색을 위한 파이프라인 CAM 구조로서, 기존 CAM(content addressable memory, 내용 주수화 메모리)을 이용한 방법보다 룩업 테이블의 갱신속도가 빠르면서도 LPM 탐색율이 높은 CAM 구조이다. PICAM은 3단계의 파이프라인으로 구성된다. 단계 1 및 단계 2의 키필드분할수 및 매칭점의 분포에 따라 파이프라인의 성능이 좌우되며, LPM 탐색율이 달라질 수 있다. 본 논문에서는 PICAM의 파이프라인 성능모델을 제시하고, 이산사건 시뮬레이션(discrete event simulation)을 수행하여, 최적의 PICAM 구조를 도출하였다. IP version 4인 경우 키필드분할수를 8로 하고, 부하가 많이 걸리는 키필드블록을 중복 설치하는 것이 최적구조이며, IP version 6인 경우 키필드블록의 개수를 16으로 하는 것이 최적구조다.

  • PDF

Development Portable Pipe Spool Location-Confirm System Based UHF RFID (UHF RFID기반 이동형 파이프 스풀 위치 인식 시스템 개발)

  • Kim, Jinsuk;Shin, Yongtae
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.3 no.10
    • /
    • pp.329-336
    • /
    • 2014
  • Pipe spool is the most important element of plant equipment in plant construction site. Currently, the plant construction site manage the pipe spool location and usage history by handwriting. Frequently, the pipe spool is moved to unpredictable places by field workers in many construction sites and in cases like this, the pipe stool is replaced with another similar pipe spool. Since it's hard to determine the exact location of some of the pipe spools, it takes unnecessary time and labour to find the missing pipe spools, which proves that stock management is not under control. The purpose of our system is to make the identification of real-time location of the field pipes possible by attaching UHF RFID tags to the pipe spool, which will be used to connect with UHF RFID reader and antenna on vehicles. A field test conducted by the proposed system resulted in the success rate of 98% and the missing 2% was recuperated by hands-on correction, which proved that stock management through the proposed method can be 100% effective. The proposed system is expected to reduce labour costs and make stock control of assets possible, as well as applicable to similar stock management environments.

Customized unsteady analysis and minimization of damage due to unsteady flow in water distribution system (상수관망의 맞춤형 부정류해석 및 부정류피해 최소화 방안)

  • Kwon, Hyuk Jae;Yoo, Min Kyu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.287-291
    • /
    • 2015
  • 본 연구에서는 두 지역의 실제 상수관망에 대해서 부정류해석을 수행하였고 각각의 상수관망에 필요한 부정류피해 최소화방안을 제시하였다. 첫 번째 대상지역은 베트남 호치민으로 148개 절점과 162개의 파이프로 이루어진 소블럭 상수관망이며 두 번째 대상지역은 파주시 광탄면으로 512개 절점과 527개의 파이프로 이루어진 세 개의 소블럭 상수관망이다. 두지역의 상수관망은 지형적면이나 규모면에서 다른 모습을 하고 있기 때문에 부정류해석 시 발생가능한 피해유형이 틀린 것으로 나타났다. 호치민의 경우 배수지의 높이가 낮고 도시 내 표고차가 없어서 관망 내 평균수압이 $1kg/cm^2$을 약간 상회하는 수준으로 수압이 낮고 수압차 역시 작다. 따라서 상수관망에서 일어날 수 있는 소요수량의 변화나 소화전 사용과 같은 작은 변화에도 역류발생이 빈번히 일어나는 것으로 나타났으며 역류발생이 잦은 파이프를 선정할 수 있었다. 상당히 많은 파이프에서 단기간 역류가 발생하는 것을 확인할 수 있었다. 짧은 기간에 발생하는 변화에 대한 단기간 역류는 교차연결(Cross-Connection)의 문제를 야기할 수 있다. 따라서 역류발생이 빈번히 일어나는 파이프 주위에 check valve나 역지밸브등의 설치를 통해 역류로 인한 피해를 최소화할 수 있다. 파주시 광탄면 지역의 소블럭 집합으로써 고저차가 많은 지역이다. 배수지 밸브개폐 시 발생 가능한 수충격에 대한 시뮬레이션과 펌프장정지로 인해 발생할 수 있는 수충격에 발생 시뮬레이션을 수행하였고 관망내에서 자주 발생하는 밸브개폐로 인한 시뮬레이션을 수행하였다. 그 결과 광탄의 경우 수충격 발생위험 지점은 배수지 근처로 나타났고 수격압이 최대 $2.5kg/cm^2$에서 $3.0kg/cm^2$까지 발생 가능한 것으로 나타났고 밸브개폐시간이 1-2초 지연되어도 상당히 큰 수격압을 줄일 수 있는 것으로 나타났다. 수충격압이 크게 발생할 수 있는 지역에 수충격피해 최소화를 위해 surge tank와 같은 장치를 설치해야 한다. 또한 발생가능한 수격압의 크기를 통계적기법을 통해 확률밀도함수로 나타낼 수 있었다. 이 결과는 앞으로 상수관망의 설계나 운영에서 수충격피해 방지 장치 및 설비를 시공할 때 장치의 규모나 용량을 결정할 때 유용한 정보가 될 것으로 판단된다.

  • PDF

Actual Collaspe Cause and Evaluation Load Carrying Capacity of Pipe-house with the Heavy Snow (폭설에 의한 파이프하우스의 붕괴 원인 분석 및 하중지지능력 평가)

  • Choi, Jae-Hyouk;Jeong, Si-Jeong;Lee, Se-Jun
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.425-428
    • /
    • 2010
  • 시공의 용이성과 저렴한 시공비로 간단하게 설치가능한 단동형 파이프하우스는 기상이변으로 인하여 농업생산에 큰 피해를 발생시키며 동시에 농업 생산기반 자체를 위협하고 있는 실정이다. 따라서 폭설에 의한 파이프하우스의 피해를 줄이기 위해서는 실제 붕괴된 피해사례의 정확한 원인분석이 필요하다. 따라서 본 논문에서는 간략화법을 이용한 극한해석을 통해 파이프하우스의 붕괴원인 분석 방법을 개발하여 실제폭설에 의한 피해사례를 적용하여 실제 붕괴하중을 검토하였다.

  • PDF

Estimation of Plastic Bending Moment of Offshore Pipelines (해저관로의 대 변형 굽힘에 의한 소성 모멘트 추정)

  • Lee, Jong-Hyun;Choi, Han-Suk
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.20-25
    • /
    • 2002
  • 본 논문은 대 변형 굽힘에 의한 소성 모멘트의 계산시 ovality를 고려한 파이프의 중립축에 대한 모멘트에 관해 논한다. 기존의 계산방법에 의한 중립축에 대한 모멘트 계산결과와 새로운 방법에 의한 계산결과를 비교해 보았다. 파이프가 길이방향의 모멘트에 의하여 굽어질 때, 증가하는 모멘트에 따른 ovality 변화를 고려하여 중립축에 대한 모멘트 계산에 적용해 보았다. 모멘트 계산은 타원형의 파이프 단면을 미세한 단면으로 나누어서 각 단면에 대한 응력을 비선형 strain-stress 식을 이용하여 구한 다음 중립축에 대해 계산을 수행하였다. 대 변형 굽힘에서 일어나는 실제현상 중 하나인 ovality를 파이프의 계산에 적용함으로써 좀 더 정확한 중립축에 대한 모멘트를 계산할 수 있었다. 이 방법을 reel에 의한 해저배관의 설치 공법에서 사용되는 reverse bending radius 계산에 적용해 보았다.

  • PDF

Thermal characteristics of energy textile by performing in-situ thermal response test (현장 열응답시험을 통한 에너지 텍스타일의 열적 거동 평가)

  • Lee, Chulho;Yoon, Sangbong;Han, Eunseon;Jeoung, Jae-Hyeung;Choi, Hangseok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.167.2-167.2
    • /
    • 2010
  • 본 연구에서는 지열 에너지원으로써 터널 내부 벽면의 항온성을 이용하여 터널 외벽에 텍스타일 형태의 열교환기를 설치하고 열적 거동을 평가하였다. 터널의 라이닝 부분에서는 여러 가지 요인에 의해 지하수가 터널 내부로 유입하게 되므로 지하수의 유무에 대한 열적 거동 및 유동액의 순환 속도에 따른 영향, 열교환 파이프 배열 형태에 따른 영향을 현장 시험 시공과 현장 열응답시험을 통하여 평가하고자 하였다. 또한 3-D 유한체적해석 프로그램(FLUENT)을 이용하여 숏크리트와 라이닝의 열전도도를 고려한 열교환기의 성능을 분석하였다. 수치해석 결과 열교환 파이프 주변에 지하수의 흐름이 존재할 경우 열전달이 상대적으로 더 원활히 이루어졌으며 순환속도가 빠를 때 보다 느릴수록 효율이 높게 나타났다. 또한, 파이프의 간격이 넓을수록, 파이프의 길이가 길수록 효율이 높게 나타났다. 라이닝 및 숏크리트의 열전도도가 증가함에 따라 에너지 텍스타일의 열전달 효율이 높게 나타났다. 현장 시험을 통해 비슷한 길이의 파이프가 사용된 경우, 파이프 배열 형태에 따라 수평형보다는 수직형 배열의 효율이 높게 측정되었다.

  • PDF

Change of Tensile Strength for Rafter Pipes of Plastic Greenhouse according to Elapsed Period (경과년에 따른 비닐하우스 서까래 파이프 인장 강도 변화)

  • Song, Hosung;Lim, Seong-Yoon;Ryu, Hee-Ryong
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.130-130
    • /
    • 2017
  • 비닐하우스의 골조를 구성하는 파이프는 부식을 방지할 목적으로 아연도강관을 사용한다. 그러나 시간이 지남에 따라 아연도금량 감소와 여러 외부 환경인자 등에 의하여 부식이나 침식이 진행되어, 외관상 녹이 생기고 강도와 연신율 등이 감소하게 된다. 이는 비닐하우스 전체의 내구성을 저하시키는 요인으로 작용하게 되는데, 이를 평가하기 위한 방법이나 기준은 미비한 실정이다. 이에 본 연구에서는 농업시설의 내구성을 평가하기 위한 방법의 하나로 각기 다른 경과년수를 갖는 비닐하우스로부터 채취한 서까래 파이프의 인장 시험을 실시하였다. 인장 시험에 사용된 서까래 파이프는 (구)시설원예시험장에 설치되어 있는 비닐하우스에서 경과년별로 채취하였으며, 지중매설부와 지상노출부로 구분하여 시편을 제작하였다. 인장 실험 결과 서까래 파이프의 경과년이 오래될수록 시편의 인장 강도는 작아지는 경향을 보이고 있으나, 파단연신율은 경과년과 연관성을 찾아보기 어려운 것으로 나타났다. 그리고 동일한 경과년을 갖는 서까래 파이프 시편에서 지중매설부의 인장 강도와 파단연신율이 지상노출부에 비해 대체로 작게 측정되었으며, 경과년이 증가할수록 인장 강도의 감소폭이 커지는 경향을 보이는 것으로 나타났다.

  • PDF