• Title/Summary/Keyword: 파울

Search Result 182, Processing Time 0.03 seconds

Study on the Fouling Reduction of the RO Membrane by the Coating with an Anionic Polymer (역삼투막 표면에 음이온 고분자 코팅을 통한 파울링 현상 감소연구)

  • Cho, Eun Hye;Cheong, Seong Ihl;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.22 no.6
    • /
    • pp.481-488
    • /
    • 2012
  • The anionic exchange polymer, poly(vinyl amine)(PVAm), was coated onto polyamide (PA) reverse osmosis (RO) membranes by using 'salting-out' method. The effects of the fouling phenomena for these PVAm coated membranes were investigated using the model foulants, bovine serum albumin (BSA), humic acid (HA), and sodium alginate (SA). The surface coating and the fouling phenomena were observed by the scanning electron microscopy. And the flux was measured for each 100 ppm of above foulant aqueous solution at the operating pressure, 2, 4, 8 bar. The PVAm-coated PA membranes showed somewhat fouling improvements and the fouling reduction was shown in the order of HA > SA > BSA, particularly HA case was distinct.

Effect of Inorganic Particles on Organic Fouling in Pressurized Membrane Filtration (가압식 분리막 여과에서 무기입자의 존재가 유기파울링에 미치는 영향)

  • Jang, Hoseok;Kim, Jeonghwan
    • Membrane Journal
    • /
    • v.30 no.2
    • /
    • pp.131-137
    • /
    • 2020
  • In this study, effect of inorganic particles on organic fouling was investigated by a laboratory-scaled pressurized membrane filtration. In order to cause organic fouling, sodium alginate (SA) was used as a feed solution. Regardless of the presence of inorganic SiO2 particles, the complete pore blocking played an important role in determining the fouling rate during the initial period of membrane filtration. However, the formation of cake layer resulted in the membrane fouling more dominantly as filtration time progressed. In the presence of inorganic particles, both specific cake resistance and compressibility associated with the membrane fouling formed were relatively lower than that without SiO2 particles. Membrane fouling was more severe at constant flux mode of filtration than that observed at constant pressure mode probably due to the concomitant increase of compressibility of fouling layer with transmembrane pressure (TMP). It was found that the presence of SA and SiO2 particles in feed solution provided the synergistic effect on the hydraulic backwashing to reduce membrane fouling as compared to the SA solution alone without the inorganic particles.

Studies on the Fouling Reduction through the Coating of Poly (vinyl alcohol) on Polyamide Reverse Osmosis Membrane Surfaces (역삼투막 표면에 폴리비닐알코올 코팅을 통한 파울링 현상 감소연구)

  • Kim, Il Hyoung;Ji, Eun Hee;Rhim, Ji Won;Cheong, Seong Ihl
    • Membrane Journal
    • /
    • v.22 no.4
    • /
    • pp.272-279
    • /
    • 2012
  • The neutral polymer, poly (vinyl alcohol) (PVA), was coated onto polyamide (PA) thin film composite reverse osmosis (RO) membranes. And then these membranes were investigated for the model foulants, bovine serum albumin (BSA), humic acid (HA), and sodium alginate (SA) whether there are aome improvement. As the operating pressure increased with 2, 4, 8 atm for BSA, HA and SA 100 ppm in feed solution, the fouling phenomena was worse for both none and PSSA coated membranes. The fouling occurred in the sequence of BSA > HA > SA due to the interactions between PVA snd functional groups of foulants, and on the other hand the fouling reduction was observed in the order of HA > BSA > SA. The observation of scanning electron microscopy photographs showed the same trend. As a result, there should be the improvement of fouling phenomena for the PVA coated RO membranes and the case of HA was shown distinct.

Studies on the Fouling Reduction by Coating of Cationic Exchange Polymer onto Reverse Osmosis Membrane Surfaces (역삼투막 표면의 양이온 교환 고분자 코팅에 의한 파울링 감소 연구)

  • Park, Chan Jong;Kim, Sung Pyo;Cheong, Seong Ihl;Rhim, Ji Won
    • Polymer(Korea)
    • /
    • v.36 no.6
    • /
    • pp.810-815
    • /
    • 2012
  • The cation exchange polymer, poly(styrene sulfonic acid) (PSSA), was coated onto polyamide (PA) thin film composite reverse osmosis (RO) membranes. Then these membranes were investigated for the model foulants, bovine serum albumin (BSA), humic acid (HA), and sodium alginate (SA) to check whether there are some improvement. The contact angle of PSSA coated PA RO membrane showed $58^{\circ}$ from $78^{\circ}$, the value of PA RO membrane, which confirmed successful hydrophilization. As the operating pressure increased (2, 4, 8 atm for BSA, HA and SA 100 ppm in feed solution), the fouling phenomena was worse for both none- and PSSA-coated membranes. The fouling increased in the order of BSA>SA>HA due to the interactions between sulfonic acid in PSSA and functional groups of foulants. On the other hand more significant fouling reduction was observed in the order of HA>SA>BSA. The photographs of scanning electron microscopy showed the same trend. As a result, there was the improvement of fouling phenomena for the PSSA coated RO membranes, distinctly in the case of HA.

Effect of Intermittent Pressure-Assisted Forward Osmosis (I-PAFO) Operation on Colloidal Membrane Fouling and Physical Cleaning Efficiency (가압형 정삼투의 간헐적 운전이 콜로이드 파울링 및 물리세정 효율에 미치는 영향)

  • Lee, Jinwoo;Kook, Seungho;Kim, Sung-Jo;Kim, In S.
    • Membrane Journal
    • /
    • v.26 no.4
    • /
    • pp.273-280
    • /
    • 2016
  • Pressure assisted forward osmosis (PAFO) is recently introduced because of its improved process efficiency to overcome drawbacks of forward osmosis (FO) such as low water flux and reverse solute diffusion. However, it is known that membrane fouling becomes deteriorated by additional hydraulic pressure applied in PAFO compared to FO. This study was performed to investigate possibility of intermittent pressure-assisted forward osmosis (I-PAFO) operation for fouling mitigation using colloidal silica particles as model foulants. FO, PAFO were operated as well to compare with. Two different solution pH conditions (pH 3, 10) were applied to see the effect of electrostatic interactions between the membrane and silica particles on fouling tendency. In the results, higher water flux was observed during pressurization and pressure relaxation periods in I-PAFO than water flux of PAFO, and FO on both pH conditions. Water flux decreased less in I-PAFO than PAFO after fouling. It resulted in higher water flux recovery in I-PAFO than PAFO after physical cleaning.

Feasibility of Pyrophyllite Ceramic Membrane for Wastewater Treatment and Membrane Fouling (국내산 납석기반 세라믹 멤브레인 수처리 적용 가능성 평가 및 파울링 현상관찰)

  • Park, Eunyoung;Jang, Hoseok;Choi, Nakcheol;Lee, Sungjae;Kim, Jeonghwan
    • Membrane Journal
    • /
    • v.26 no.3
    • /
    • pp.205-211
    • /
    • 2016
  • Performance of pyrophyllite-based ceramic membranes newly developed were investigated. Membrane fouling caused by microbial suspensions taken from a full-scaled MBR system at domestic wastewater treatment plant was observed at different airflow rate and distance between each membrane. For the pyrophyllite support, pore size was about $1.0{\mu}m$, but surface coating with $Al_2O_3$ solution decreased the pore size with the reduction of the pure water permeability. With the MLSS taken from the full-scaled MBR system (6 g/L), the fouling rate was decreased by increasing airflow rate under $20L/m^2{\cdot}hr$ of setpoint flux. However, the effectiveness of the airflow rate on the fouling control depends strongly upon the gap between each membrane. At fixed airflow rate, the fouling rate was decreased by increasing the gap between each pyrophyllite membrane. Nevertheless, further increasing the membrane distance from 3.5 to 5.4 cm resulted in higher fouling rate. Similar result was observed with the $Al_2O_3$ coated-pyrophyllite membrane. Nevertheless, the fouling rate was lower with the coated membrane than that observed with the uncoated pyrophyllite support. Regardless of surface coating, the suspended solids were removed almost completely and the surface coating on the pyrophyllite support improved organic rejection with PEG solution (MW : 8000 kDa) tested.

Characteristics of Heat Recovery Rate and Fouling according to Structures and Materials in Heat Exchangers (열교환장치의 구조 및 재질에 따른 열회수율과 파울링의 발생 특성)

  • Kim, Hyun-Sang;Kim, Yong-Gu;Bong, Choon-Keun;Lee, Myong-Hwa
    • Resources Recycling
    • /
    • v.24 no.2
    • /
    • pp.3-12
    • /
    • 2015
  • We researched characteristics of heat recovery rate and fouling according to structures and materials in heat exchangers like water preheater and air preheater. Economizer and air preheater have used in thermal electric power plant. we made small incinerator and heat exchangers to carry out simulated experiment. We observed fouling formation and change of heat recovery rate, combusting powdered coal for 24 hr. In economizer, fin tube type had the largest amount of fouling formation, followed by tube line type > pipe type > auto washing type according to structures. As heat recovery rate, fin tube showed highest recovery rate, followed by auto washing type > pipe type > tube line type. In air preheater, fin tube type had the largest amount of fouling formation, followed by fin plate type > pipe type > pipe type coated by teflon > pipe type coated by ceramic according to structures. And then, heat recovery rate showed the same oder.

Effect of Cross-flow Velocity and TMP on Membrane Fouling in Thermophilic Anaerobic Membrane Bioreactor Treating Food Waste Leachate (음식물 침출수를 처리하는 막결합 고온혐기성 소화시스템에서 교차여과와 막간압력이 파울링에 미치는 영향)

  • Kim, Young-O;Jun, Duk-Woo;Yoon, Seong-Kyu;Chang, Chung-Hee;Bae, Jae-Ho;Yoo, Kwan-Sun;Kim, Jeong-Hwan
    • Membrane Journal
    • /
    • v.21 no.4
    • /
    • pp.360-366
    • /
    • 2011
  • The effect of cross-flow velocity and transmembrane pressure (TMP) on membrane fouling was observed from pilot-scale operation of thermophilic anaerobic membrane bioreactor (AnMBR) treating food waste leachate. It was found that fouling rate was reduced significantly as cross-flow velocity increased at constant TMP mode of operation while this effectiveness was more pronounced at lower TMP. Higher TMP resulted in less permeable fouling layer possibly due to compressibility of foulant material on membrane surface. Particle sizes of membrane concentrate ranged from 10 to $100{\mu}m$, implying that shear-induced diffusion enhance back transport of these particle sizes away from the membrane effectively. From the continuous operation of AnMBR, it was confirmed that shear rate played an important role in the reduction of membrane fouling. Membrane autopsy works at the end of operation of AnMBR showed clearly that both organic and inorganic fouling were significant on membrane surface. Surface shear by cross-flow velocity was expected to be less effective to remove irreversible fouling which can be mainly caused by the adsorption of organic colloidal materials into membrane pores.

A Study on the Heat Exchanger Fouling Characteristics of Sludge Incinerator at the IronWorks (제철슬러지 소각로 열교환기에서의 파울링특성 연구)

  • 박상일;김정근;김기홍;박용준;조성문
    • Journal of Energy Engineering
    • /
    • v.12 no.3
    • /
    • pp.223-230
    • /
    • 2003
  • A study was performed to measure and analyze the gas-side fouling of heat exchanger to cool the exhaust gas from sludge incinerator at ironworks. The incinerator gas passes through inside of the vertical tubes of heat exchanger to preheat the combustion air. This kind of fouling occurs at the entrance region of the heat exchanger and thus the perforated fouling plate was designed to measure the gas-side fouling and to analyze the particulate deposit. As a result of analysis, the particulate deposition rate was influenced by temperature, particulate composition and size and also the deposition patterns were different according to the location of perforated fouling plate. The computational analysis was performed to obtain the deposition rates at the perforated fouling plate and the calculation showed that the deposition rate was varied with the hole size and particulate size. It was proved that the fouling at the entrance region of heat exchanger could be measured by the perforated fouling plate designed in this study.