• Title/Summary/Keyword: 파울

Search Result 182, Processing Time 0.029 seconds

A Study on Optimization of Manufacture Conditions for Water Treatment Membrane by Using Electrospinning Method (전기방사법을 이용한 수처리용 막 제조 조건 최적화 연구)

  • Lee, Sang Hyun;Choi, Sung Yeol;Chang, Soon Woong;Kim, Sung Su
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.8
    • /
    • pp.456-461
    • /
    • 2017
  • In this study, nano fibers with various physical properties were materialized by using a variety of polymers [PAN (Polyacrylonitrile), PU (Polyuretane), PSU (Polysulfone)] which are raw materials of dope solution manufactured for electrospinning and solvents [NMP (N-methyl-2 pyrrolidone), DMF (Dimethylformamide)] and evaluated characteristics of their flux and SS (Suspended Solids) separation and then ascertained application of manufactured fibers as separation membrane for water treatment. In this study, analysis of surface of manufactured material was carried out through SEM analysis to ascertain the cause of flux and SS separation performance by checking diameter, uniformity and straightness of fiber. If additive is used in manufacturing nano fiber water treatment separation membrane, it is expected to solve problems such as membrane fouling and mechanical strength and to be used as basic factor for manufacturing separation membrane with catalyst function added.

Effect of Pre-ozonation on the Trans-membrane Pressure of Ceramic Membrane (전오존이 세라믹 막의 차압에 미치는 영향)

  • Bae, Byung-Uk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.9
    • /
    • pp.656-661
    • /
    • 2011
  • The performance of a domestic ceramic membrane with pore size of $0.1{\mu}m$ was evaluated to produce drinking water. A pilot-scale ceramic membrane filtration plant with a capacity of $1m^3/d$ was operated at the filtration flux of $3.0m^3/m^2{\cdot}d$ to investigate the effect of both backwash interval and pre-ozonation on TMP (trans-membrane pressure) increasing rate. The TMP increased with increasing the backwash interval. However, the application of pre-ozonation reduced the TMP increasing rate remarkably. When 1 mg/L of ozone was dosed with contact time of 5 min, TMP increasing rate at the backwash interval of 1 hr was reduced by 30%. This result indicated that pre-ozonation was very effective in reducing membrane fouling. There was almost no change in TMP increasing rate when the ozone contact time was maintained in the range of 5 to 15 min. Increasing ozone concentration up to 3 mg/L showed beneficial effect on TMP increasing rate.

Predictions of Fouling Phenomena in the Axial Compressor of Gas Turbine Using an Analytic Method (해석적 방법을 이용한 가스터빈 축류 압축기의 파울링 현상 해석)

  • Song, Tae-Won;Kim, Dong-Seop;Kim, Jae-Hwan;Son, Jeong-Rak;No, Seung-Tak
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1721-1729
    • /
    • 2001
  • The performance of gas turbines is decreased as their operating hours increase. Fouling in the axial compressor is one of main reasons for the performance degradation of gas turbine. Airborne particles entering with air at the inlet into compressor adhere to the blade surface and result in the change of the blade shape, which is closely and sensitively related to the compressor performance. It is difficult to exactly analyze the mechanism of the compressor fouling because the growing process of the fouling is very slow and the dimension of the fouled depth on the blade surface is very small compared with blade dimensions. In this study, an improved analytic method to predict the motion of particles in compressor cascades and their deposition onto blade is proposed. Simulations using proposed method and their comparison with field data demonstrate the feasibility of the model. It if found that some important parameters such as chord length, solidity and number of stages, which represent the characteristics of compressor geometry, are closely related to the fouling phenomena. And, the particle sloe and patterns of their distributions are also Important factors to predict the fouling phenomena in the axial compressor of the gas turbine.

고 분산성 자성 나노유체의 열전도도 및 점성

  • Seo, Yong-Jae;Lee, Hyo-Suk;Jo, Guk;Gil, Dae-Seop;Jeong, Gyeong-U;Ju, Myeong-Eun
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.4.2-4.2
    • /
    • 2010
  • 최근 열전달율을 획기적으로 향상시킬 수 있는 고 열전도성 나노유체가 주목을 받고 있다. 고 열전도성 나노유체는 액상보다 열전도도가 수백~수만 배 높은 고상의 금속 또는 비금속 나노입자를 물이나 오일 등에 미량 균일하게 분산시킴으로써 기존의 유체가 가지지 못한 높은 열전도율과 분산안정성을 갖는 기능성유체를 말한다. 고 열전도성 나노유체는 기존 냉각시스템에서 냉각유체만 교체할 경우에도 열전달 효율을 20% 이상 향상시킬 수 있는 저비용 고효율작동 유체이다. 이 나노유체는 발전설비, 공조설비, 에너지 산업, 석유화학, 화학공업, 제철산업, 가정용 냉난방설비, 자동차 등 산업 전 분야의 열교환시스템에 활용이 가능하다. 따라서 고 열전도성 나노유체는 종래 열효율의 한계를 돌파할 수 있는 에너지 이용 효율 향상 기술의 패러다임을 바꿀 혁신적인 신소재로 여겨지고 있다. 그러나 현재까지 개발된 나노유체는 초기 열전도 특성은 우수하나 장기간 분산안정성이 확보되지 않아 시간이 경과함에 따라 열전도도가 점점 감소하는 경향을 보인다. 또한 탄소나노튜브를 분산한 나노유체의 경우와 같이 유체의 점도가 크게 증가하여 실제 산업에 적용 시 커다란 동력손실을 초래할 수 있으며 열교환시스템에 파울링이 발생할 소지가 크다. 이러한 문제점을 해결하기 위해서는 나노유체에서 열전달이 일어나는 메커니즘이 규명되어야 하지만 아직 명확한 이론이나 가설이 정립되어 있지 않다. 이 논문에서는 나노유체가 높은 열전도율을 보이는 현상을 설명할 수 있는 몇 가지 이론을 살펴 보고 지금까지 개발된 안정성이 아주 높은 나노유체의 열전도 특성을 비교 분석하여 획기적인 열전도성 나노유체 개발 가능성을 살펴보고자 한다. 이를 위해 나노입자의 조성, 유체 내 농도 및 자기장 등이 나노유체의 열전도율에 미치는 영향을 연구하였다.

  • PDF

Forward Osmosis Membrane to Treat Effluent from Anaerobic Fluidized Bed Bioreactor for Wastewater Reuse Applications (하수재이용을 위한 혐기성 유동상 생물반응기 처리수의 정삼투 여과막의 적용)

  • Kwon, Dae-eun;Kim, Jeonghwan
    • Membrane Journal
    • /
    • v.28 no.3
    • /
    • pp.196-204
    • /
    • 2018
  • The anaerobic fluidized bed bioreactor (AFBR) treating synthetic wastewater to simulate domestic sewage was operated under GAC fluidization to provide high surface area for biofilm formation. Although the AFBR achieves excellent COD removal efficiency due to biological activities, concerns are still made with nutrient such as nitrogen remaining in the effluent produced by AFBR. In this study, forward osmosis membrane was applied to treat the effluent produced by AFBR to investigate removal efficiency of total nitrogen (TN) with respect to the draw solution (DS) such as NaCl and glucose. Permeability of FO membrane increased with increasing DS concentration. About 55% of TN removal efficiency was observed with the FO membrane using 1 M of NaCl of draw solution, but almost complete TN removal efficiency was achieved with 1 M of glucose of draw solution. During 24 h of filtration, there was no permeate flux decline with the FO membrane regardless of draw solution applied.

A Study on Fouling Phenomena of in Petroleum Chemical Process (석유화학공정내에서 원유의 파울링 현상에 관한 연구)

  • Lee, Dong Rak;Ryu, Sang Ryoun;Park, Sang Jin;Cho, Wook Sang;Kim, Sang Wook
    • Applied Chemistry for Engineering
    • /
    • v.7 no.3
    • /
    • pp.443-452
    • /
    • 1996
  • Fouling is caused by sedimentation and corrosion of polymer, heavy paraffine, chemicals, heavy organics, asphaltene, etc. in the entire chemical process of heat exchanger, boiler, desalter, etc. Fouling phenomena remains a serious operating problem which results in increased energy consumption, increased pressure drops, reduction or complete loss of products yield, and increased maintenance costs. In order to calculate the separated amounts of foulants and to control the fouling process, the predictive model is developed which is based on Scott & Magat polymer solution theory, Peng-Robinson EOS, BWR EOS, and continuous and multicomponent thermodynamics.

  • PDF

A Study of the Current State of Korean Restaurants in São Paulo in Brazil (브라질 상파울루시의 한식당 현황 및 만족도 조사)

  • Chung, Hae-Kyung;Woo, Na-Riyah;Kim, Mi-Hye
    • Journal of the Korean Society of Food Culture
    • /
    • v.27 no.3
    • /
    • pp.261-273
    • /
    • 2012
  • To find an efficient solution for the globalization of Korean food in Brazil, we conducted a survey about the satisfaction of Brazilian natives who had visited a Korean restaurant, and possible suggestions for improvement. We also conducted indepth interviews with 13 owners of Korean restaurants in Seo Paulo, Brazil, about their plans to improve Korean food to be more appealing to the Brazilian palate. Our research shows that Korean restaurants had a below average reputation for employee kindness, menu taste and variety, interior, mood, and accessibility. As a result of the survey, we found that Korean restaurants were considered in general to be below average. The survey also showed that the higher the level of a person's economic standing, the less satisfaction they had with Korean food restaurants. We also found that the most common pieces of advice that Brazilian women had regarding Korean restaurants were to offer more variety in the menu, maintain a cleaner restaurant, and to actively engage in public relations. The general concerns of everyone surveyed focused on cleanliness and public relations of the restaurant. However, food-related people focused more on the taste and quality of the food. Sao Paulo is currently the most well-developed economic center in South America, so the world's food service industry is pushed to the front of its ongoing development. For Korean food to make inroads into Brazil, Korean restaurants need to change the niche that they occupy. First-generation family businesses and second-generation specialized family businesses coexist in that city. So first of all, to localize the Korean food for Brazilian tastes, a menu system that will easily allow natives to access Korean food must be established. And second of all, it must support the total food culture by improving distribution, sanitation management, and marketing methods that can get the natives to like Korean food ingredients.

Effects of Alkali Metals and Chlorine on Corrosion of Super Heater Tube in Biomass Circulating Fluidized Bed Boiler (순환유동층보일러의 과열기 튜브 부식에 알칼리 금속과 염소가 미치는 영향)

  • Back, Seung-Ki;Yoo, Heung-Min;Jang, Ha-Na;Joung, Hyun-Tae;Seo, Yong-Chil
    • Applied Chemistry for Engineering
    • /
    • v.28 no.1
    • /
    • pp.29-34
    • /
    • 2017
  • This study provides the identification of corrosion cause substances in super heater tube from a commercial scale circulating fluidized bed boiler. Electricity is produced by the combustion of biomass mainly wood waste. The biomass, super heater tube, super heater tube ash, and boiler ash were collected and components associated with corrosion were analyzed. A large amount of oxygen-containing material was found due to oxidation. The chlorine content was analyzed as 6.1% and 4.3% in super heater tube ash and boiler ash respectively which were approximately 20 and 14 times higher than those of designed values. Also, alkaline metal contents (K, Na, Ca) were very high in ash samples collected from super heater tube and boiler. The tendency of slagging and fouling was predicted based on X-Ray Fluorescence (XRF) results. Basicity that can lead to slagging was estimated as 3.62 and 2.72 in super heater tube and boiler ash, respectively. Slagging would occur with ash content when considering the designed value as 0.35.

Studies on the Analytical Methods of Coal Ash (석탄회 분석 방법에 관한 연구)

  • Park, Hyun Joo;Kim, Kyeong Sook;Yang, Seug Ran;Lee, Gae Ho
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.6
    • /
    • pp.563-572
    • /
    • 2000
  • The analysis of coal ash is very important to predict some factors, such as slagging and fouling in the boiler, and to determine optimum mixing ratios of the each coals used. In ASTM, the analysis of coal ash is clarified to use lithium metaborate (LiBO$_2$) as a fluxing agent and then to analyze the pre-treated samples using AAS. However, it takes too much time and efforts to analyze many samples by ASTM method, as a result, this method is not proper in our laboratory in charge of analyses of all power plants. So we tried to establish more convenient and accurate analytical method of coal ash by 3 different methods which are 2 different pre-treatment methods (fusion dissolution and microwave digestion) and XRF analysis method using a clear pellet. Although all 3 methods can be utilized to analyze the major elements of coal ash, each method has its own characteristics, therefore, each method should be chosen according to its own purpose.

  • PDF

High Lift Device Design Optimization and Wind Tunnel Tests (고양력장치 설계 최적화 및 풍동시험)

  • Lee, Yung-Gyo;Kim, Cheol-Wan;Cho, Tae-Hwan
    • Aerospace Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.78-83
    • /
    • 2010
  • In the present paper, a flap was optimized to maximize the lift. A 2-element fowler flap system was utilized for optimization with an initial shape of general aviation airfoil and a flap shape designed by Wentz. Response surface method and Hicks-Henne shape function were implemented for optimization. 2-D Navier-Stokes method was used to solve flow field around aGA(W)-1 airfoil with a fowler flap. Commercial programs including Visual-Doc, Gambit/Tgridand Fluent were used. Upper surface shape and the flap gap were optimized and lift for landing condition was improved considerably. The original and optimized flaps were tested in the KARI's 1-m low speed wind tunnel to examine changes in aerodynamic characteristics. For optimized flap tests, the similar trend to prediction could be seen but stall angle of attack was lower than what was expected. Also, less gap than optimized design delayed stall and produced better lift characteristics. This is believed to be the effect of turbulence model.