• Title/Summary/Keyword: 파브리-페로 공진기

Search Result 4, Processing Time 0.021 seconds

Integrated Cavity Output Spectroscopy Using an External Cavity Diode Laser for the Density Absorption Measurement of Trace Gases (미량 기체의 밀도 측정을 위한 외부 공진기 반도체 레이저 광학공동 적분 투과 분광법)

  • Ryoo Hoon Chul;Yoo Yong Shin;Lee Jae Yong;Hahn Jae Won
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.1
    • /
    • pp.24-30
    • /
    • 2006
  • Integrated cavity output spectroscopy(ICOS) is a simple, non-intrusive absorption measurement technique that can detect and quantify trace-level gas species. The spectral absorbance of a gas is quantified from the integrated optical output of the modulated high-finesse cavity containing the sample which is irradiated by a wavelength-swept laser source. We constructed an experimental setup by using a tunable single mode external cavity diode laser operating at the wavelength near 765 nm and a Fabry-Perot cavity with length modulation achieved by a piezoelectric transducer where one of the cavity mirrors sat on. In the experiment performed on minute oxygen gas at the wave-length near 764.5nm, we demonstrated the minimum detectable absorption of $8.45\times10^{-8}cm^{-1}$.

Optical Phase-looking of Semiconductor Lasers (반도체 레이저의 광 위상 동기)

  • 신철호
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1991.07a
    • /
    • pp.141-146
    • /
    • 1991
  • 최근 고분해능 분광, 코히어런트 광통신 등의 중요한 기반 기술인 레이저간의 위상 동기에 관한 연구와 이의 시스템에의 응용이 활발히 전개되고 있다. 이 논문에서는 레이저에 의한 광 위상 동기 루우프의 기본 동작 원리, 구성법, 특징, 응용 범위 및 위상 오차를 종합 분석하고, 공촛점 파브리 페로 공진기 결합 광귀환형 반도체 레이저에 의한 헤테로다인 및 호모다인 광 위상 동기 루우프의 최근 실험 결과를 소개한다.

  • PDF

Precise Temperature Control by Locking on the Fixed point of Gallium (갈륨의 고정점을 이용한 정밀 온도제어)

  • 김태호;김승우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.351-354
    • /
    • 2002
  • The new enhanced method of temperature control need not any reference temperature, the system itself can find the melting temperature of gallium as a reference point by dithering input heat flux. If gallium is in melting state, the latent heat of fusion works, so gallium temperature does not change on dithering input heat flux. Also, the control method can determine the state of gallium; solid, liquid, or melting state by investigating the temperature in gallium. We apply this new temperature stabilization method to stabilize a Fabry-Perot cavity, which serves as a ultimate length measurement technique. We achieved 1 mK-temperature stability and 1.5426 nm/ 95 mm-length stability over 10 hours.

  • PDF

1.3μm Waveband Al2O3/a-Si Thin-Film Etalon and Measurements of Optical Constants (1.3μm 파장 Al2O3/a-Si 박막 에탈론과 광학 상수 측정)

  • Song, H.W.;Kim, J.H.;Han, W.S.
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.5
    • /
    • pp.476-478
    • /
    • 2005
  • We have fabricated a Fabry-Perot etalon around $1.3\;{\mu}m$ wavelength utilizing $Al_{2}O_3$ and a-Si thin films. A full width at half maximum of ${\sim}12.1nm$ and a finesse value of 53 were found from the measured resonant transmission spectra. Single thin film of $Al_{2}O_3$ was analyzed by spectroscopic ellipsometry. A refractive index of a-Si thin film was measured as 3.120 in the real part and 0.002 in the imaginary part, respectively. The thin-film pairs of $Al_{2}O_3$ and a-Si are applicable to output mirrors of vertical-cavity surface-emitting lasers at $1.3{\mu}m$ waveband.