• Title/Summary/Keyword: 파라미터 가시화기법

Search Result 13, Processing Time 0.026 seconds

Dynamic Parameter Visualization and Noise Suppression Techniques for Contrast-Enhanced Ultrasonography (조영증강 초음파진단을 위한 동적 파라미터 가시화기법 및 노이즈 개선기법)

  • Kim, Ho-Joon
    • Journal of KIISE
    • /
    • v.42 no.7
    • /
    • pp.910-918
    • /
    • 2015
  • This paper presents a parameter visualization technique to overcome the limitation of the naked eye in contrast-enhanced ultrasonography. A method is also proposed to compensate for the distortion and noise in ultrasound image sequences. Meaningful parameters for diagnosing liver disease can be extracted from the dynamic patterns of the contrast enhancement in ultrasound images. The visualization technique can provide more accurate information by generating a parametric image from the dynamic data. Respiratory motions and noise from micro-bubble in ultrasound data may cause a degradation of the reliability of the diagnostic parameters. A multi-stage algorithm for respiratory motion tracking and an image enhancement technique based on the Markov Random Field are proposed. The usefulness of the proposed methods is empirically discussed through experiments by using a set of clinical data.

가시화를 이용한 SI 엔진의 연소 진단

  • 엄인용
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.115-154
    • /
    • 2005
  • SI 엔진의 연소특징은 비정상 난류 예혼합 화염이며 여기서 내부 유동은 직접 화염 전파에 영향을 미치며 난류와 거시적 유동의 패턴 모두 중요한 역할을 한다. 내연기관 연소에서 난류는 매우 중요한 역할을 하고 통상 엔진 속도($\approx$흡입유동 속도)에 비례하며 그 주요 역할은 고속 운전 시 해당 사이클 내에 연소가 완료되는 데 기여하지만 출력저하, 제어 및 측정 그리고 사이클 변동과 관련하여 실질적으로 난류 제어를 통한 엔진 성능 개선은 사실상 불가능하다. 실물 엔진의 성능 파라미터로 주로 유동의 거시적 거동이 사용되며 이 유동과 연료 분사계가 혼합기 분포 상태와 화염 전파 방향을 결정하여 최종적으로 엔진의 성능을 지배한다. 따라서 가시화를 통한 연소 진단도 이 현상에 주목할 필요가 있으며 거시적 파라미터를 성능에 연관하는 다양한 기법이 존재하고 이들은 매우 풍부한 데이터베이스를 통해 비교적 정확한 성능의 예측을 가능하게 하고 이 점에 주목한 엔진만 성공을 거두었다. 이 거시적 현상에 주목하여 가시화를 통해 성층화 현상을 실험적으로 해석한 예를 제시하였다. SI 엔진 가시화에서 기법보다 중요한 것은 현상의 이해이다. 이를 위해 성공적 가시화 진단을 위해서는 우선 현상에 대한 모델링이 필요하고 이 모델에서 가시화를 통해 규명 가능한 현상을 추출해 내는 것이다.

  • PDF

Parametric Image Generation and Enhancement in Contrast-Enhanced Ultrasonography (조영증강 초음파 진단에서 파라미터 영상 생성 및 개선 기법)

  • Kim, Shin-Hae;Lee, Eunlim;Jo, Eunbee;Kim, Ho-Joon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.10a
    • /
    • pp.708-711
    • /
    • 2016
  • 본 논문에서는 의료초음파 영상에서 진단 파라미터 데이터를 가시화 하는 방법론으로서 연속적인 픽셀 값을 갖는 전이시간 데이터의 표현과, 4가지 유형의 값으로 분류되는 병변 진단 파라미터 영상을 생성하는 방법을 제시한다. 또한 생성된 파라미터 영상에서 노이즈를 제거하기 위한 방법론으로서 MRF 모델을 이용한 영상개선 기법을 제안한다. 이러한 파라미터 영상 생성기법은 초음파 진단 데이터에서 조영증강 패턴의 동적인 변화에 대한 육안 판별의 한계를 극복할 수 있게 한다. MRF 기반 영상개선 과정에서 연속적인 픽셀 값에 대한 에너지함수를 정의하고 이를 최적화 하는 기법을 개발하였으며 실제 의료영상을 사용한 실험을 통하여 제안된 이론의 유용성을 평가하였다.

Topographic Non-negative Matrix Factorization for Topic Visualization from Text Documents (Topographic non-negative matrix factorization에 기반한 텍스트 문서로부터의 토픽 가시화)

  • Chang, Jeong-Ho;Eom, Jae-Hong;Zhang, Byoung-Tak
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2006.10b
    • /
    • pp.324-329
    • /
    • 2006
  • Non-negative matrix factorization(NMF) 기법은 음이 아닌 값으로 구성된 데이터를 두 종류의 양의 행렬의 곱의 형식으로 분할하는 데이터 분석기법으로서, 텍스트마이닝, 바이오인포매틱스, 멀티미디어 데이터 분석 등에 활용되었다. 본 연구에서는 기본 NMF 기법에 기반하여 텍스트 문서로부터 토픽을 추출하고 동시에 이를 가시적으로 도시하기 위한 Topographic NMF (TNMF) 기법을 제안한다. TNMF에 의한 토픽 가시화는 데이터를 전체적인 관점에서 보다 직관적으로 파악하는데 도움이 될 수 있다. TNMF는 생성모델 관점에서 볼 때, 2개의 은닉층을 갖는 계층적 모델로 표현할 수 있으며, 상위 은닉층에서 하위 은닉층으로의 연결은 토픽공간상에서 토픽간의 전이확률 또는 이웃함수를 정의한다. TNMF에서의 학습은 전이확률값의 연속적 스케줄링 과정 속에서 반복적 파리미터 갱신 과정을 통해 학습이 이루어지는데, 파라미터 갱신은 기본 NMF 기반 학습 과정으로부터 유사한 형태로 유도될 수 있음을 보인다. 추가적으로 Probabilistic LSA에 기초한 토픽 가시화 기법 및 희소(sparse)한 해(解) 도출을 목적으로 한 non-smooth NMF 기법과의 연관성을 분석, 제시한다. NIPS 학회 논문 데이터에 대한 실험을 통해 제안된 방법론이 문서 내에 내재된 토픽들을 효과적으로 가시화 할 수 있음을 제시한다.

  • PDF

Parametric Image Generation and Enhancement in Contrast-Enhanced Ultrasonography (조영증강 초음파 진단에서 파라미터 영상 생성 및 개선 기법)

  • Kim, Shin-Hae;Lee, Eun-Lim;Jo, Eun-Bee;Kim, Ho-Joon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.6 no.4
    • /
    • pp.211-216
    • /
    • 2017
  • This paper proposes image processing techniques that improve usability and performance in a diagnostic system of the contrast-enhanced ultrasonography. For a methodology for visualizing diagnostic parameter data in an ultrasonic medical image, an expression of transition time data with successive pixel values and a method of generating a lesion diagnostic parameter image with four categorized values are presented. We also introduce a MRF-based image enhancement technique to eliminate noises from generated parametric images. Such parametric image generation technique can overcome the difficulty of discriminating dynamic change in patterns in the ultrasonography. The technique clarifies the contour of the region in the original image and facilitates visual determination of the characteristics of the lesion through four colors. With regard to this MRF-based image enhancement, we define the energy function of consecutive pixel values and develop a technique to optimize it, and the usability of the proposed theory is examined through experiments with medical images.

Parametric Imaging with Respiratory Motion Correction for Contrast-Enhanced Ultrasonography (조영증강 초음파 진단에서 호흡에 의한 흔들림을 보정한 파라미터 영상 생성 기법)

  • Kim, Ho-Joon;Cho, Yun-Seok
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.9 no.2
    • /
    • pp.69-76
    • /
    • 2020
  • In this paper, we introduce a method to visualize the contrast diffusion patterns and the dynamic vascular patterns in a contrast-enhanced ultrasound image sequence. We present an imaging technique to visualize parameters such as contrast arrival time, peak intensity time, and contrast decay time in contrast-enhanced ultrasound data. The contrast flow pattern and its velocity are important for characterizing focal liver lesions. We propose a method for representing the contrast diffusion patterns as an image. In the methods, respiratory motion may degrade the accuracy of the parametric images. Therefore, we present a respiratory motion tracking technique that uses dynamic weights and a momentum factor with respect to the respiration cycle. Through the experiment using 72 CEUS data sets, we show that the proposed method makes it possible to overcome the limitation of analysis by the naked eye and improves the reliability of the parametric images by compensating for respiratory motion in contrast-enhanced ultrasonography.

Scale Space Filtering based Parameters Estimation for Image Region Segmentation (영상 영역 분할을 위한 스케일 스페이스 필터링 기반 파라미터 추정)

  • Im, Jee-Young;Kim, Myoung-Hee
    • Journal of the Korea Computer Graphics Society
    • /
    • v.2 no.2
    • /
    • pp.21-28
    • /
    • 1996
  • The nature of complexity of medical images makes them difficult to segment using standard techniques. Therefore the usual approaches to segment images continue to predominantly involve manual interaction. But it tediously consumes a good deal of time and efforts of the experts. Hereby a nonmanual parameters estimation which can replace the manual interaction is needed to solve the problem of redundant manual works for an image segmentation. This paper attempts to estimate parameters for an image region segmentation using Scale Space Filtering. This attempt results in estimating the number of regions, their boundary and each representatives to be segmented 2-dimensionally and 3-dimensionally. Using this algorithm, we may diminish the problem of wasted time and efforts for finding prerequisite segmentation parameters, and lead the relatively reasonable result of region segmentation.

  • PDF

Visualization of Contrast Enhancement Patterns in Ultrasound Images (의료 초음파 영상에서 조영증강 패턴의 가시화 기법)

  • Lee, Jun-Yong;Jung, Joong-Eun;Kim, Ho-Joon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.04a
    • /
    • pp.862-863
    • /
    • 2015
  • 본 연구에서는 조영증강 초음파 진단에서 혈류의 패턴을 효과적으로 판단할 수 있게 하기 위하여 조영제의 확산패턴을 영상으로 표현하는 방법론을 제안한다. 초음파 영상에서 조영제의 전이 시간에 대한 파라미터의 가시화 기법과, 단계별 전이패턴을 단일 영상으로 표현하는 방법을 제시함으로써, 병변의 진단 및 분석과정에서 대상 영역 내 혈류의 형태와 속도를 효과적으로 판별할 수 있게 한다. 분석과정의 필요에 따라 영상에서 정밀도를 선택적으로 적용할 수 있도록 하였으며, 노이즈 제거를 위한 필터링 과정과 단계별 전이 시점의 위치에 대한 영역 분할 과정을 거쳐 영상 생성결과를 개선할 수 있도록 하였다.

Transfer Function Optimization Using Crowd Sourcing (크라우드 소싱을 이용한 변환함수 최적화)

  • Nam, Jinhyun;Nam, Doohee
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.4
    • /
    • pp.107-112
    • /
    • 2014
  • This Study is Transfer function optimization plan of volume rendering of multi user environment. Each volume data, for appropriate transfer function, they should be adjusted parameter many times. To prevent this, we propose transfer function optimization plan using crowd sourcing. In multi user environment, we use weight value for reliability level for each user. Because transfer function parameter used previous users is provided next users, they can be used effectively optimized transfer function and can reduce attempts.

Parametric Shape Modeling of Femurs Using Statistical Shape Analysis (통계적 형상 분석을 이용한 대퇴골의 파라메트릭 형상 모델링)

  • Choi, Myung Hwan;Koo, Bon Yeol;Chae, Je Wook;Kim, Jay Jung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.10
    • /
    • pp.1139-1145
    • /
    • 2014
  • Creation of a human skeleton model and characterization of the variation in the bone shape are fundamentally important in many applications of biomechanics. In this paper, we present a parametric shape modeling method for femurs that is based on extracting the main parameter of variations of the femur shape from a 3D model database by using statistical shape analysis. For this shape analysis, principal component analysis (PCA) is used. Application of the PCA to 3D data requires bringing all the models in correspondence to each other. For this reason, anatomical landmarks are used for guiding the deformation of the template model to fit the 3D model data. After subsequent application of PCA to a set of femur models, we calculate the correlation between the dominant components of shape variability for a target population and the anatomical parameters of the femur shape. Finally, we provide tools for visualizing and creating the femur shape using the main parameter of femur shape variation.