• Title/Summary/Keyword: 파라미터

Search Result 7,046, Processing Time 0.035 seconds

Dynamic Characteristic Analysis Procedure of Helicopter-mounted Electronic Equipment (헬기 탑재용 전자장비의 동특성 분석 절차)

  • Lee, Jong-Hak;Kwon, Byunghyun;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.8
    • /
    • pp.759-769
    • /
    • 2013
  • Electronic equipment has been applied to virtually every area associated with commercial, industrial, and military applications. Specifically, electronics have been incorporated into avionics components installed in aircraft. This equipment is exposed to dynamic loads such as vibration, shock, and acceleration. Especially, avionics components installed in a helicopter are subjected to simultaneous sine and random base excitations. These are denoted as sine on random vibrations according to MIL-STD-810F, Method 514.5. In the past, isolators have been applied to avionics components to reduce vibration and shock. However, an isolator applied to an avionics component installed in a helicopter can amplify the vibration magnitude, and damage the chassis, circuit card assembly, and the isolator itself via resonance at low-frequency sinusoidal vibrations. The objective of this study is to investigate the dynamic characteristics of an avionics component installed in a helicopter and the structural dynamic modification of its tray plate without an isolator using both a finite element analysis and experiments. The structure is optimized by dynamic loads that are selected by comparing the vibration, shock, and acceleration loads using vibration and shock response spectra. A finite element model(FEM) was constructed using a simplified geometry and valid element types that reflect the dynamic characteristics. The FEM was verified by an experimental modal analysis. Design parameters were extracted and selected to modify the structural dynamics using topology optimization, and design of experiments(DOE). A prototype of a modified model was constructed and its feasibility was evaluated using an FEM and a performance test.

A Performance Comparison of the Mobile Agent Model with the Client-Server Model under Security Conditions (보안 서비스를 고려한 이동 에이전트 모델과 클라이언트-서버 모델의 성능 비교)

  • Han, Seung-Wan;Jeong, Ki-Moon;Park, Seung-Bae;Lim, Hyeong-Seok
    • Journal of KIISE:Information Networking
    • /
    • v.29 no.3
    • /
    • pp.286-298
    • /
    • 2002
  • The Remote Procedure Call(RPC) has been traditionally used for Inter Process Communication(IPC) among precesses in distributed computing environment. As distributed applications have been complicated more and more, the Mobile Agent paradigm for IPC is emerged. Because there are some paradigms for IPC, researches to evaluate and compare the performance of each paradigm are issued recently. But the performance models used in the previous research did not reflect real distributed computing environment correctly, because they did not consider the evacuation elements for providing security services. Since real distributed environment is open, it is very vulnerable to a variety of attacks. In order to execute applications securely in distributed computing environment, security services which protect applications and information against the attacks must be considered. In this paper, we evaluate and compare the performance of the Remote Procedure Call with that of the Mobile Agent in IPC paradigms. We examine security services to execute applications securely, and propose new performance models considering those services. We design performance models, which describe information retrieval system through N database services, using Petri Net. We compare the performance of two paradigms by assigning numerical values to parameters and measuring the execution time of two paradigms. In this paper, the comparison of two performance models with security services for secure communication shows the results that the execution time of the Remote Procedure Call performance model is sharply increased because of many communications with the high cryptography mechanism between hosts, and that the execution time of the Mobile Agent model is gradually increased because the Mobile Agent paradigm can reduce the quantity of the communications between hosts.

Analysis of $^{99m}Tc-ECD$ Brain SPECT Images for ADHD in Children Using Statistical Parametric Mapping (SPM) (주의력 결핍 과잉행동장애(ADHD) 어린이 $^{99m}Tc-ECD$ Brain SPECT Image의 SPM을 이용한 분석)

  • 박성옥;신동호;권수일;이명훈;조철우;윤석남;오은영
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.141-148
    • /
    • 2003
  • The purpose of this study is to evaluate the distribution of clusters and blood flow rate in ADHD SPECT brain blood flow images of children using statistical parametric mapping (SPM99). We studied 64 ADHD children (4-15 y, $8.03{\pm}2.57$ y. male/female:52/12) and compared them with a control group of 12 children (6-l7 y, $9.42{\pm}3.37$ y, male/female:8/4). We injected blood flow tracer $^{99m}Tc$-ethylcysteinate dimer (ECD) as a rCBF agent and took blood flow images after 30 min. by SPECT camera. In the case of hyperperfusion of rCBF in the ADHD group, we found 3 clusters clearly separated at the cingulate gyrus, Rt.cerebral occipital lobe and Lt.cerebellar post. lobe, on probability level 0.05 (P<0.05). Thirty-six ADHD patients with average hyperfusion rates between 18.72-19.30% in each cluster had more increase in blood flow than the average perfusion rate at the Rt. cerebral occipital lobe. These levels were influenced by P-value. In the case of hypoperfusion in the ADHD children, 4 decreased clusters on Lt. and Rt. cerebral frontal lobe, Lt. cerebral claustrum and Rt. cerebral, sup. temporal gyrus at P<0.01 can be seen. The average hypoperfusion rates for the ADHD children were 18.41-18.69% in each cluster, which showed more hypopefusion than the average perfusion rate at the Lt. Cerebrum inf. Frontal gyrus. The perfusion rates and the number of patients were not affected by P-value. The result of this study shows significant hyperpefusion clusters at the probability level of P:0.05 and hypoperfusion clusters at P:0.01. The number of ADHD patients in each clusters and the perfusion rate were not affected by P-value.

  • PDF

Different Metabolic Patterns of Parkinsonism: Analysed by Statistical Parametric Mapping (통계적 파라미터를 이용한 Parkinsonism의 Metabolic pattern 분석)

  • 주라형;김재승;최보영;문대혁;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.108-123
    • /
    • 2003
  • The purpose of this study is to evaluate the contribution of $^{18}$ F-FDG brain PET in the differentiating Idiopathic parkinson's diesease (IPD), progressive supranuclear palsy (PSP), and multiple system atrophy (MSA). We studied 24 patients with parkinsonism : 8 patients (mean age 67.9$\pm$10.7 y: M/F : 3/5) with IPD, 9 patients (57.9$\pm$9.2 y : M/F : 4/5) with MSA and 7 patients (67.6$\pm$4.8 y : M/F 3/4) with PSP. All patients with parkinsonism and 22 age-matched normal controls underwent $^{18}$ F FDG PET in 3D mode after the injection of 370 MBq $^{118}$ F FDG. The patients with IPD, MSh and PSP were compared with a normal control group by a two-sided t-test of SPM99 (uncorrected P<0.001, extent threshold>100 voxel). All three parkinsonism groups, showed significant hypometabolism in the cerebral neocortex compared to the normal control group. However, the three groups displayed different metabolism in the subcortical structure, brain stem, and cerebellum. In IPD, there was no significant hypometabolism in the putamen, brain stem and cerebellum. However, MSA patients showed significant hypometabolism in the striatum, pons, and cerebellum compared to the normal controls and IPD patients. In addition, PSP showed significant hypometabolism in the caudate nuclei, the thalamus, midbrain, and the cingulate gyrus compared to the normal controls, the IPD, and MSA groups (IPD vs Normal sensitivity/specificity : 75%/l00%, MSA vs Normal sensitivity/specificity :100%/87%, PSP vs Normal sensitivity/specificity : 86%/94%). Our results show that the regional metabolism of IPD, MSA, and PSP is different mainly in the striatum, thalamus, brain stem and cerebellum. An assessment of the $^{18}$ F-FDG PET scan images using SPM may be a useful adjunct to a clinical examination in making a differential diagnosis of Parkinsonism.

  • PDF

Effect of Substrata Surface Energy on Light Scattering of a Low Loss Mirror (기판의 표면에너지가 반사경의 산란에 미치는 영향)

  • Lee, Beom-Sik;Yu, Yeon-Serk;Lee, Jae-Cheul;Hur, Deog-Jae;Cho, Hyun-Ju
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.6
    • /
    • pp.452-460
    • /
    • 2007
  • Ultra-low loss ZERODUR and fused silica mirrors were manufactured and their light scattering characteristics were investigated. For this purpose, ZERODUR and fused silica substrates were super-polished by the bowl feed method. The surface roughness were 0.292 ${\AA}$ and 0.326 ${\AA}$ in rms for ZERODUR and fused silica, respectively. To obtain the high reflectivity, 22 thin film layers of $SiO_2$ and $Ta_2O_5$ were deposited by Ion Beam Sputtering. The measured light scattering of ZERODUR and fused silica mirror were 30.9 ppm and 4.6 ppm, respectively. This shows that the substrate surface roughness is not the only parameter which determines the light scattering of the mirror. In order to investigate the mechanism for additional light scattering of the ZERODUR mirror, the surface roughness of the mirror was measured by AFM and was found to be 2.3 times higher than that of the fused silica mirror. It is believed that there is some mismatch at the interface between the substrate and the first thin film layer which leads to the increased mirror surface roughness. To clarify this, the contact angle measurements were performed by SEO 300A, based on the Giriflaco-Good-Fowkes-Young method. The fused silica substrates with 0.46 ${\AA}$ in its physical surface roughness shows lower contact angle than that of the ZERODUR substrate with 0.31 ${\AA}$. This indicates that the thin film surface roughness is determined by not only its surface roughness but also the surface energy of the substrate, which depends on the chemical composition or crystalline orientation of the materials. The surface energy of each substrate was calculated from a contact angle measurement, and it shows that the higher the surface energy of the substrate, the better the surface roughness of the thin film.

Estimation on Population Ecological Characteristics of Crucian Carp, Carassius auratus in the Mid-Upper System of the Seomjin River (섬진강 중.상류 수계에서 붕어 개체군의 생태학적 특성치 추정)

  • Jang, Sung-Hyun;Ryu, Hui-Seong;Lee, Jung-Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.25 no.3
    • /
    • pp.318-326
    • /
    • 2011
  • The population ecological characteristics of the Crucian carp, Carassius auratus, were determined in order to estimate stock of the mid-upper system of the Seomjin River. The fish ranged in size from 95 to 288mm total length. The age was determined by counting the scale annulus. The scales displayed clear annulus that were used to estimate the age. The oldest fish observed in this study was 5 years old. Age-2 fishes were the most numerous in the sample(n=38), followed in frequency be age-3(n=22). Marginal index analysis validated the formation of a single annulus per year. The relationship between body length and body weight was BW = $0.0038BL^{3.73}$($R^2$=0.96) (p<0.01). The relationship between the scale radius and body length was BL = 2.362R+2.76($R^2$=0.89). The von Bertalanffy growth parameters estimated from a non-linear regression method were $L_{\infty}$=33.2 cm, $W_{\infty}$=1,798.4 g, $K=0.20year^{-1}$ and $t_0$=-0.51year. Therefore, Growth in length of the fish was expressed by the von Bertalanffy's growth equation as $L_t=33.23$($1-e^{-0.20(t+0.51)}$)($R^2$=0.98). The annual survival rate was estimated to be 0.427year$^{-1}$. The instantaneous coefficient of natural mortality of estimated from the Zhang and Megrey method was $0.784year^{-1}$, and instantaneous coefficient of fishing mortality was calculated $0.067year^{-1}$. From the estimates of survival rate, the instantaneous coefficient of total mortality was estimated to be $0.851year^{-1}$.

A new diagnostic method for diabetic neuropathy using $TcpO_2$ ($TcpO_2$ 이용한 당뇨병성 신경병증 환자의 조기진단)

  • Hong, Hyun-Ki;Kim, Sung-Woo;Nam, Ki-Chang;Cha, Eun-Jong;Kim, Deok-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.3
    • /
    • pp.1-8
    • /
    • 2007
  • PDiabetic neuropathy is one of the most common diabetes related complications including diabetic nephropathy and retinopahty. In clinical practices, nerve conduction velocity (NCV) has been used as a standard method for diagnosing diabetic neuropathy. However, it applies maximum current of 100mA to nerves causing stress and pain to patients. In this study, as a non-invasive method, $TcpO_2$ was utilized to investigate the difference and relationship between $TcpO_2$ and $SpO_2$ of normal and diabetic neuropathy subjects. In addition, a new method of diagnosing diabetic neuropathy using $TcpO_2$ is suggested. 50 normal subjects and 50 diabetic patients with neuropathy diagnosed by NCV participated in this study. Parameters used in this study were $TcpO_2$, $TcpCO_2$, and $SpO_2$. As a result of the $TcpO_2$ measurements, statistical significances were found from $TcpO_2$ of hands and feet from normal and patients group(p<0.01). $SpO_2$ measured from index finger of normal and patient groups showed no statistical significance(p>0.05). On the other hand, $SpO_2$ measured from great toes of normal and patient groups showed statistical significance(p<0.01). Correlation coefficient between $SpO_2$ of finger and $TcpO_2$ of hand was 0.400 (p<0.01) and $SpO_2$ of toe and $TcpO_2$ of foot was 0.471(p<0.01). Both correlation values were statistically significant. Sensitivities and specificities of the $TcpO_2$ method were found to be 66 % and 92 %, respectively. If the suggested $TcpO_2$ method is used periodically, prevention and early diagnosis of diabetic neuropathy would be possible.

Theoretical Analysis of Bragg-Reflector Type FBAR with Resonance Mode (공진 모드에 따른 Bragg-Reflector Type FBAR 의 이론적 분석)

  • 조문기;윤영섭
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.11
    • /
    • pp.9-18
    • /
    • 2003
  • Two configurations of Film Bulk Acoustic Wave Resonators with acoustic quater-wave bragg reflector layers are theoretically analyzed using equivalent circuits and the difference of their characteristics are discussed. We compare the characteristics of λ/2 mode to those of ideal FBAR with top and bottom electrode contacting air and the characteristics of λ/4 mode to those of ideal FBAR with top electrode contacting air and bottom electrode clamped. We assume that the piezoelectric film is ZnO, the electrode is A1 and the substrate is Si, ABCD parameters are extracted and input impedance is calculated by converting the equivalent circuit from Mason equivalent circuits to the simplified equivalent circuits that ABCD parameters are extracted possible, From the variation of resonance frequency due to the change of thickness of reflector layers and the variation of electrical Q due to the change of mechanical Q of reflector layers, it is confirmed that the reflector layer just under the bottom electrode have the greatest effect on the varation of resonance frequency and electrical Q. It is shown that the number of reflector layers required for the saturation of electrical Q decreases with the increase of the impedance ratio of reflector layers and electrical Q of λ/2 mode is larger than that of λ/4 mode, Electromechanical coupling factor is independent of the number of layers, The impedance ratio of reflector layers becomes larger as the electromechanical coupling factor becomes larger, The electromechanical coupling factor of the two mode are smaller than those of ideal FBARs because of the trapping of acoustic energy in the reflector layers, The insertion loss of the ladder filter decreases with the increase of the number of reflector layers but the bandwidth is not affected much by the number of reflector layers, As the impedance ratio of reflector layers becomes larger the insertion loss becomes smaller and the bandwidth becomes wider, In our analysis of the two mode, characteristics of λ/2 mode appear to be slightly more favorable than that of λ/4 mode

Influence on Intra-limb Coordination in Individuals Wearing a Knee Extension Constraint Brace during Walking (무릎 신전 제한형 보조기 착용이 보행 시 하지 내 협응에 미치는 영향)

  • Chang, Yoonhee;Jeong, Bora;Kang, Sungjae;Ryu, Jeicheong;Kim, Gyu Seok;Mun, Museong;Ko, Chang-Yong
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.3
    • /
    • pp.207-214
    • /
    • 2016
  • The aim of this study was to evaluate Influence on intra-limb coordination in individuals wearing knee brace during walking. Seven healthy male adults ($32.3{\pm}2.7$ years old, $175.2{\pm}3.8cm$, $76.2{\pm}8.7kg$) participated. They wore knee brace or didn't wear any knee brace and were asked to walk along a 10 m long walkway. Spatiotemporal parameters, angles of the lower limbs, and intra-limb continuous relative phase (CRP) were measured and calculated. No differences of spatiotemporal parameters were shown (all p > 0.05). There were no changes in the angle and its range of motion (ROM) in the hip for the subjects as wearing knee brace, while ROM ($65.5{\pm}3.7^{\circ}$ vs. $60.5{\pm}3.5^{\circ}$, p < 0.05) of the angle and maximum flexion angles (stance: $31.9{\pm}4.6$ vs. $25.6{\pm}5.5$, swing: $76.7{\pm}3.1$ vs. $68.9{\pm}3.4$, all p < 0.05) in the knee significantly decreased. No changes in ROM of angle in the ankle were shown, whereas maximum dorsiflexion decreased ($22.4{\pm}2.6$ vs. $19.2{\pm}2.1$, p < 0.05) and maximum plantarflexion increased ($9.5{\pm}3.0$ vs. $15.7{\pm}2.2$, p<0.05). There were no changes in most of CRP between joints. CRP between the hip and knee joints decreased ($93.0{\pm}7.8$ vs, $84.7{\pm}4.9$, p < 0.05). Most of CRP standard deviation increased (between the hip and ankle joint during swing: $25.1{\pm}6.7$ vs. $32.4{\pm}1.9$, between the knee and ankle joint during stance: $46.0{\pm}12.9$ vs. $80.1{\pm}31.1$, between the knee and ankle joint during swing: $34.5{\pm}4.1$ vs. $37.6{\pm}3.1$, all p < 0.05). These results indicated that wearing knee brace affected joint angle and intra-limb coordination, but less affected gait features.

Electrochemical Generation of Chlorine Dioxide from Sodium Chlorite Using Un-Divided Electrochemical Cell: Effect of Anode Materials (아염소산나트륨의 무격막 전기분해에 의한 이산화염소 생성: 양전극 재질에 따른 영향)

  • Kwon, Tae Ok;Park, Bo Bae;Roh, Hyun Cheul;Moon, Il Shik
    • Korean Chemical Engineering Research
    • /
    • v.48 no.2
    • /
    • pp.275-282
    • /
    • 2010
  • A characteristic study of aqueous chlorine dioxide generation from sodium chlorite($NaClO_2$) by an undivided electrochemical cell with different anode materials were performed. $IrO_2$-coated Ti, $RuO_2$-coated Ti and DSA were used as anode materials and Pt-coated Ti electrode was used as cathode. Various electrochemical cell operating parameters such as cell residence time($t_R$), initial feed solution pH, sodium chlorite and sodium chloride(NaCl) concentration and applied current for the generation of chlorine dioxide in an un-divided cell were investigated and optimized. Estimated optimal cell residence times in $IrO_2$-coated Ti, $RuO_2$-coated Ti and DSA anode material systems were around 2.27, 1.52 and 1.52 sec, respectively. Observed optimum initial feed solution pH was around 2.3 in all anode material systems. Optimum sodium chlorite concentrations in $IrO_2$-coated Ti, $RuO_2$-coated Ti and DSA anode systems were around 0.43, 0.43 and 0.32 g/L, respectively. Optimum electrolyte concentration and applied current were around 5.85 g/L and 0.6 A in all anode systems. Current efficiencies of $IrO_2$-coated Ti, $RuO_2$-coated Ti and DSA anode systems under optimum conditions were 79.80, 114.70 and 70.99%, respectively. Obtained energy consumptions for the optimum generation of chlorine dioxide were 1.38, 1.03 and $1.61W{\cdot}hr/g-ClO_2$, respectively.