• Title/Summary/Keyword: 파단 강도

Search Result 588, Processing Time 0.024 seconds

Properties in Strength of Raschel Netting (랏쉘그물감의 강도)

  • KIM Dai An
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.11 no.1
    • /
    • pp.39-48
    • /
    • 1978
  • 1) The decrease in strength of Raschel twines at Raschel joints is regarded to be due mainly to the frictional force between yarns and the unbalanced tensile distribution by the deformation of the joints. The rate of the decrease is about $13\%$ in lengthwise pull and 22 to $26\%$ in breadthwise pull. 2) The 3-course joint is less in deformation and stronger than the 2-course joint in all cases of pulls. 3) The variation of Raschel joint strength $T_R$ with the angle $\varphi$ between the adjacent bars is expressed as $T_R=T_{R0}-k\varphi$ where $T_{R0}$ is the strength at $\varphi=0^{\circ}$ and K is a constant. 4) The tensile strength ${\sigma}R$ and tile breaking energy $E_R$ of Raschel netting are given by $${\sigma}R=KN\;or\;${\sigma}R=T_RN$$ and $$E_R=AN$$ respectively, where N is the number of meshes at the pulling side, and K and A are constants. But the breaking energy of the netting is almost constant independent of tile variation of N. 5) The Raschel netting with some bars cut already breaks from tile joints of the bars next to the cut bars and its tensile strength, breaking energy, and breaking elongation decrease largily even if only one bar is in already cut state. 6) The tearing strength of Raschel netting is almost equal to the tensile strength of its single joint pulled by two bars. 7) The twisted joint is much more excellent in strength than the knot or the Raschel joint. The knot strength is 69 to $76\%$, and the Raschel joint strength is 71 to $74\%$ in lengthwise pull and 62 to $67\%$ in breadthwise pull, respectively, of the twisted joint strength.

  • PDF

Evaluation of Bending Strength for Ceramic Honeycomb Using Design of Experiments (실험계획법을 이용한 세라믹 허니컴의 굽힘강도평가)

  • Kim, Jong-Kyu;Baek, Seok-Heum;Cho, Seok-swoo;Shin, Soon-Ki;Joo, Won-Sik
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.379-384
    • /
    • 2006
  • Since the monolithic ceramic substrate was introduced for automotive catalytic converters, the durability of the substrate has been a continuing requirement to reduce the emission gas of vehicle. The substrate can occupy a volume as small as 82 $cm^3$ and as large as 8200 $cm^3$ to provide the required substrate for catalytic activity. The long-term durability varies with the size of the substrate from manufacture's point of view. Therefore This study presents that the response surface model using central composite design can explain size effect on the modulus of rupture in a cordierite ceramic monolithic substrate.

  • PDF

Energy-Based Seismic Evaluation of Reinforced Concrete Structures I - Flexural Components (에너지에 근거한 철근콘크리트 구조물의 내진성능 평가 I - 휨요소)

  • 김장훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.3
    • /
    • pp.33-44
    • /
    • 1999
  • An energy balance procedure is developed to incorporate the effects of earthquake duration which involves the effect of cyclic loading and the corresponding cumulative plastic deformation. Particular emphasis is given to the flexural failure of non-seismically designed columns of reinforced concrete frames. For this, conceptual strength deterioration models for columns, governed by concrete, anchorage failure and longitudinal steel fracture due to low-cycle fatigue, are proposed. It is evident that the energy-based method has good agreement with the experimental data and is able to predict the failure mode.

  • PDF

Hydrogen Delayed Fracture of Automotive Multi-Phase Sheet Steels by Hydrogen Charging Condition (수소주입에 따른 자동차용 복합조직강판의 지연파괴 거동)

  • Park, Jae-U;Gang, Gye-Myeong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2013.05a
    • /
    • pp.87-87
    • /
    • 2013
  • 복합조직강의 미세조직제어를 통한 자동차용 고강도 강판재의 개발이 주요 연구과제로 있다. 하지만 고강도화에 따라 수소에 의한 지연파괴의 문제점이 있어, 이를 규명하고 해결하기 위한 많은 연구가 함께 이루어지고 있다. 본 연구에서는 연구, 개발되고 있는 복합조직강 중 DP강과 TRIP강의 수소취성에 미치는 미세조직의 영향을 분석하고, 수소주입조건에 따른 수소취성 및 지연파괴 거동에 대하여 조사하고자 하였다. 이를 위해 음극전기분해법을 이용, 주입수소량을 달리하여 주입수소가 복합조직강의 지연파괴에 미치는 영향을 분석하였다. Hydrogen determinator를 통해 시편 내 수소량을 측정하였고, 소형펀치시험에 의한 기계적물성 변화를 조사하였다. 또한 파단부위의 넓이와 깊이를 비교측정하였고, 파단면을 SEM으로 관찰하여 수소지연파괴 거동을 평가하고자 하였다.

  • PDF

Evaluation of Impact Characteristics for High Strength Structural Steel at Low Temperature (고강도 구조용강의 저온 충격특성 평가)

  • 김재훈;김덕회;김후식;조성석;전병완;심인옥
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.5 no.3
    • /
    • pp.1-9
    • /
    • 2001
  • Impact tests are performed on the high strength structural steel that is being developed for the submarine material. Especially, the impact characteristics of this structural steels at low temperatures are investigated by charpy impact testing. Hyperbolic tangent curve fitting method is used to evaluate the LSE(lower shelf energy), USE(upper shelf energy) and DBTT(ductile-brittle transition temperature). Proportional equations between charpy impact energy and lateral expansion are obtained using the test results. Effect of temperature on the fracture appearance is investigated by using SEM.

  • PDF

Creep Rupture Due to Molybdenum Rich $M_6C$ Carbide in 1.0Cr-1.0Mo-0.25V Steel Weldment (1.0Cr-1.0Mo-0.25V강 용접부의 $M_6C$ 탄화물에 의한 크립 파단)

  • O, Yeong-Geun;Kim, Byeong-Cheol;Gang, Gye-Myeong;Min, Tae-Guk
    • Korean Journal of Materials Research
    • /
    • v.6 no.12
    • /
    • pp.1257-1262
    • /
    • 1996
  • 1.0Cr-1.0Mo-0.25V강 용접부의 크립 파단 시험시 파단 발생 원인에 관한 연구가 시행되었다. 파괴는 Intercritical Heat Affected Zone에서 발생하였으며 파단면에서 구상의조대한 M6C탄화물이 발견되었다. 모재는 molybdenum 주성분의 M2C, vanadium 주성분의 M4C3 및 chromium 주성분의 M23C6와 M7C3 탄화물이 존재하였다. 모의 실험 결과 준안정 상태인 M2C 탄화물은 85$0^{\circ}C$, 10oh에서 안정한 M6C탄화물로 변태하였다. M6C 탄화물은 주변의 molybdenum 농도를 떨어뜨려 강도의 저하를 가져오며 크립 기공의 발생 원인을 제공하였다.

  • PDF

Flexural Strength Evaluation of PSC Beam with Loss of PS Tendon Area (PS강재의 단면적 감소에 따른 PSC보의 휨강도 평가)

  • Park, Soon-Hyung;Kim, Yong-Tae;Youn, Seok-Goo;Kim, Eun-Kyum
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.309-312
    • /
    • 2008
  • This paper describes ultimate load tests which were performed to show the effects of prestress loss and tendon corrosion on the flexural strength of post-tensioned concrete beams and the occurrence of wire fracture. Five test specimens were fabricated in laboratory with the variations of the prestress of tendons and the loss of tendon area. For two specimens, small area of tendon at the center of the beam was exposed by using diameter 25mm drill and the exposed tendon was corroded using accelerated corrosion equipment. During the tests, deflections, crack width, and strain changes were measured and acoustic events were monitored with two acoustic sensors. Tests results show that the ultimate flexural strength of test specimens with corroded tendons is smaller than the predicted flexural strength which is calculated considering the loss of tendon area. It is considered that estimation of flexural strength of PSC beams with corroded tendons is very complicated just based on the loss of tendon area obtained by one-side visual inspection.

  • PDF

Characteristics of microstructure and mechanical strength of ASTM A387-Gr.91 Steel deteriorated under high-temperature (고온 열화된 ASTM A387-Gr. 91 강의 미세 조직 및 기계적 강도 특성)

  • Jeong, Gwang-Hu;Han, Min-Su;Kim, Seong-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.111-111
    • /
    • 2018
  • ASTM A387-Gr.91 강은 우수한 고온 강도, 크리이프 저항성 그리고 내산화성 등으로 인해 화력 및 바이오매스 발전 시설과 같은 고온 설비의 구조재료로 널리 사용되고 있다. 고온 환경에서 높은 강도는 탄화물과 탄질화물에 의한 석출강화가 주 요인으로 작용한다. 열처리 과정에서 Mo, Cr, Mn, 그리고 Fe는 구-오스테나이트 및 마르텐사이트 라스 입계에 $M_{23}C_6$ 탄화물로 석출되며, V, Nb, 및 N은 조직 내부에 미세한 MX 탄질화물로 석출된다. 따라서 합금의 고온 강도는 조직 내 석출물의 개수밀도와 크기에 크게 의존한다. 그러나 적용 환경의 특성 상 고온 노출에 따른 2차상 석출 및 조대화의 조직열화 현상이 발생하며, 이는 재료의 강도를 저하시킨다. 본 연구에서는 ASTM A387-Gr.91 강의 미세조직 열화에 따른 강도저하 및 파괴 양상을 고찰하는데 그 목적을 두었다. 본 연구에서 사용된 ASTM A387-Gr.91 강의 화학성분(wt, %)은 0.1 C, 0.38 Si, 0.46 Mn, 0.25 Ni, 8.38 Cr, 0.93 Mo, 0.18 V, 0.09 Nb, 그리고 나머지는 Fe 이다. 조직열화 및 기계적 강도저하 특성을 평가하기 위한 등온열화는 $650^{\circ}C$의 대기 환경에서 최대 1000시간동안 실시하였다. 열화된 시험편의 미세조직 및 탄화물에 대한 분석은 SEM과 EDS를 이용하여 실시하였다. 그리고 기계적 강도 평가는 인장실험과 비커스 경도시험을 통해 실시하였다. 또한 열화 시간에 따른 파단양상의 변화를 관찰하기 위해 인장시험편의 파단면을 SEM과 EDS를 이용하여 분석하였다. 그 결과, 열화에 따른 마르텐사이트 라스의 소실, 탄화물의 조대화, 그리고 2차상 석출의 조직 열화현상이 나타났다. 또한 기계적 강도는 조직 열화에 따라 저하되는 경향을 나타냈다.

  • PDF

A Study on Shear-Fatigue Behavior of New Polymer Reinforced Concrete Beams (신(新)폴리머 철근(鐵筋)콘크리트보의 전단피로(剪斷疲勞) 거동(擧動)에 관(關)한 연구(研究))

  • Kwak, Kae Hwan;Park, Jong Gun;Jang, Ki Woong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.3
    • /
    • pp.35-44
    • /
    • 1993
  • The objective of this study is aimed at developing a new class of polymer concrete, in which hydration of cement and curing of a thermosetting resin can take place simultaneously during the mixing of concrete components. For the selected mix-proportion of the new polymer, the physical and mechanical properties needed for designs are presented. These important properties are compressive strength, flexural strength, split tensile strength, direct strength, fatigue characteristics and fracture parameters. The observed properties are always compared with conventional concrete to serve as reference for engineer in deciding or selecting the proper materials for their projects, and shore protecting structure.

  • PDF

Axial Behavior of Concrete Cylinders Confined with FRP Wires (FRP 와이어 보강 콘크리트 공시체의 압축거동)

  • Cho, Baiksoon;Lee, Jong-Han;Choi, Eunsoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.5
    • /
    • pp.1765-1775
    • /
    • 2013
  • The application of FRP wire as a mean of improving strength and ductility capacity of concrete cylinders under axial compressive load through confinement is investigated experimentally in this study. An experimental investigation involves axial compressive test of three confining amounts of FRP wire and three concrete compressive strengths. The effectiveness of FRP wire confinement on the concrete microstructure were examined by evaluating the internal concrete damage using axial, circumferential, and volumetric strains. The axial stress-strain relations of FRP wire confined concrete showed bilinear behavior with transition region. It showed strain-hardening behavior in the post-cracking region. The load carrying capacity was linearly increased with increasing of the amount of FRP wire. The ultimate strength of the 35 MPa specimen confined with 3 layer of FRP wire was increased by 286% compared to control one. When the concrete were effectively confined with FRP wire, horizontal cracks were formed by shearing. It was developed from sudden expansion of the concrete due to confinement ruptures at one side while the FRP wire was still working in hindering expansion of concrete at the other side of the crack. The FRP wire failure strains obtained from FRP wire confined concrete tests were 55~90%, average 69.5%, of the FRP wire ultimate uniaxial tensile strain. It was as high as any other FRP confined method. The magnitude of FRP wire failure strain was related to the FRP wire effectiveness.