• Title/Summary/Keyword: 파괴간섭

Search Result 56, Processing Time 0.023 seconds

Shake Table Response and Analysis of RC Bridge Piers with Lap-Spliced Steel under NFGM (주철근 겹침이음된 RC교각의 근단층지반운동에 대한 진동대 응답과 분석)

  • Chung, Young-Soo;Park, Chang-Young;Hong, Hyun-Ki;Park, Ji-Ho;Shim, Chang-Su
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.4
    • /
    • pp.451-458
    • /
    • 2008
  • The near-fault ground motion (NFGM) is characterized by a single long period velocity pulse of large magnitude. NFGM's have been observed in recent strong earthquakes, Izmit Turkey (1999), Kobe Japan (1995), Northridge USA (1994), etc. These strong earthquakes have caused considerable damage to infrastructures because the epicenter was close to the urban area, called as NFGM. Extensive research for the near-fault ground motion (NFGM) have been carried out in strong seismic region, but limited research have been done for NFGM in low or moderate seismic regions because of very few records. The purpose of this study is to investigate and analyze the effect of near-fault ground motions on reinforced concrete (RC) bridge piers with lap-spliced longitudinal reinforcing steels. The seismic performance of four RC bridge piers under near-fault ground motions was investigated on the shake table. In addition, a RC bridge pier is subjected to pseudo-dynamic loadings. Test results showed that large residual displacements were observed in RC bridge piers under NFGM. RC specimens on the shake table failed at relatively low displacement ductility, compared with the displacement ductility of RC bridge pier subjected to pseudo-dynamic loadings.

Landscape Value Analysis of Hallyǒ Haesang Sea National Park (한려해상국립공원(閑麗海上國立公園)의 경관자원(景觀資源) 가치분석(價値分析))

  • Kim, Sei-Cheon
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.2
    • /
    • pp.145-160
    • /
    • 2000
  • This study is focused to the national park of Korean typical Sea Hally$\check{o}$ Haesang, and its visual resources and practiced inspect course by the way of suppositions and tests, to show the visual resource management objectively, and that of qualitative basic data. Accordingly by measuring the physical amount spatial structure with the visual amount originated from the Mesh Analyzing Method and the Visual Preference from the Scenic Beauty Estimation(S.B.E.) method and analyzed the valuation of the visual resource by Iverson method. Spatial image structure measured by Semantic Differential(S.D.) Scale was shown through the factor analysis algorithm for the analyzing psychological amount and examined the flowing out of decisive factor and the objective importance related to the mutual factors by appling the measurement of the visual quality. As a national Park, the visual factors that have natural landscape harmonized with forest, sky, surface of the water, curious stones and rocks, and temples should be escalated their values affirmatively so as to be the scenery of pointed direction and enjoyable, and it is of more needed for visual resource and its' controlling technique to make artificial structures more intentional planning and systemical setting. When we are viewing the improvement for the national park along with the visual resource management, reasonable level of development is needed, because when men interference surpass plantations and leasts will be damaged and the quality of natural landscape can be lowered, so it is needed to set up a management end, tangibly or clearly; and it is permitted limit coming and going ablably by accounting the suitable number for availing. But the controling end should be set in every level, positive management, very actively within the permissive varcability. It is the main business for the national park to prevent the damage from human for their gay life or to prevent the damage of a land carpet, and to restorate for the visual resource management.

  • PDF

A Study on the Error Rate of Non-destructive Rebar Detection Under Different Environmental Factors (환경적 요인에 따른 비파괴 철근 탐사의 오차율에 관한 연구)

  • Kang, Beom-Ju;Kim, Young-Hwan;Kim, Young-Min;Park, Kyung-Han;Oh, Hong-Seob
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.506-513
    • /
    • 2021
  • The durability and safety of reinforced concrete structures significantly depend on the reinforcement conditions, concrete cover thickness, cracks, and concrete strength. There are two ways to accurately determine the information on reinforcing bars embedded in concrete - the local destructive method and the non-destructive rebar detection test. In general, the non-destructive rebar detection tests, such as the electromagnetic wave radar method, electromagnetic induction method, and radiation method, are adopted to avoid damage to the structural elements. The moisture content and temperature of concrete affect the dielectric constant, which is the electrical property of concrete, and cause interference in the non-destructive rebar detection test results. Therefore, in this study, the effects of the electromagnetic wave radar method and electromagnetic induction method have been analyzed according to the temperature and surface moisture content of concrete. Due to the technological advancement and development of equipment, the average error rate was less than 5% in the specimens at 24℃, irrespective of their operating principles. Among the tested methods, the electromagnetic induction method showed very high accuracy. The electromagnetic wave radar method indicated a relatively small error rate in the dry state than in the wet state, and exhibited a relatively high error rate at high temperatures. It was confirmed that the error could be reduced by applying the electromagnetic wave radar method when the temperature of the probe was low and in a dry state, and by using the electromagnetic induction method when the probe was in a wet state or at a high temperature.

Lightning Protection System of Solar Power Generation Device (태양광발전장치의 낙뢰보호 시스템)

  • Yongho Yoon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.2
    • /
    • pp.157-162
    • /
    • 2023
  • Among the failures of photovoltaic power generation facilities, failures caused by surges account for 20% of the total failure rate, and energy emissions of tens to hundreds [A] during power generation and electrical damage to inverters and connection boards lead to electrical safety accidents. In particular, in the case of lightning, an abnormal voltage is induced in an electric circuit to destroy insulation, and the current flowing at this time causes a fire and acts as a factor that accelerates the deterioration of parts. Due to this action, the problem of electrical safety of solar power generation devices spreading from outside the city center to the inside of the city center such as houses, apartments, and government offices is emerging. Since lightning strikes cause both field-based and conducted electrical interference, this effect increases with increasing cable length or conductor loops. In addition, surge damages not only solar modules, inverters and monitoring devices, but also building facilities, which can eventually cause operational shutdown due to fire of the photovoltaic power generation system and consequent financial loss. Therefore, in this paper, a lightning protection system for solar power generation devices is studied for the purpose of reducing property damage and human casualties due to the increase in fire and electrical safety accidents caused by lightning strikes in photovoltaic power generation systems.

Pollen Analysis on Tangjeong Plains, Asan-Si, Korea (아산(牙山) 탕정평야(湯井平野)의 화분분석(花粉分析))

  • PARK, Ji-Hoon;JANG, Dong-Ho
    • Journal of The Geomorphological Association of Korea
    • /
    • v.17 no.2
    • /
    • pp.53-61
    • /
    • 2010
  • In this study, pollen analysis and a dating were performed on the alluvial deposits in the Tangjeong Plains in Asan-Si, Chungcheongnam-Do. Specimens were collected at the altitude of about 12m, which belongs to the mid-forest belt in the cool temperate zone. The followings show the results. In general, the target zone passed through TJ-I (the coniferous forest age in which the Pinus forest was dominant), TJ-II (the mixed conifer and deciduous broad-leaved forest age in which Pinus and Quercus were dominant) and TJ-III (the coniferous forest age in which the Pinus was dominant) respectively. TJ-II was subdivided into TJ-IIa and TJ-IIb. TJ-I is presumed to be between about 2,810 and 1,500yrB.P.; TJ-IIa to be between about 1,500 and 1,370yrB.P.; and TJ-IIb to be between about 1,370 and 770yrB.P. As for TJ-III, it is presumed to begin after about 770yrB.P. In comparison with the nationwide pollen zone during the Postglacial, TJ-I and TJ-II are contrasted with the R-IIIa period and also TJ-III is contrasted with RIIIb (so-called human interference age). It is also presumed that Pinus luxuriated there after about 770yrB.P. as forests began to be markedly destroyed in the Tangjeong Plains.

Landscape Changes of the Mujechi Moor, Mt. Jungjok (정족산 무제치늪의 경관발달)

  • 유호상;공우석
    • The Korean Journal of Quaternary Research
    • /
    • v.15 no.2
    • /
    • pp.101-109
    • /
    • 2001
  • The landscape changes at the Mujechi moors I and II during the last twenty two years were analysed using a tree ring analysis of pine trees, a distributional pattern of pine tree, an aerial photograph interpretation and a measurement of firebreak line. The analysis of aerial photographs(taken in 1978, 1988, 1998) indicates that the area of Mujechi moors I and II have gradually decreased. The decreased rate of moor area was relatively high, i.e.,-23.9 %(1978~1988) and -16.4 %(1998~1998) at the Mujechi moor I, but a little bit low, i.e., -2.6% (1978~1988) and -12.6 % (1998~1998) at the Mujechi moor II. However, dendrochronological analysis of pine trees at moors I and II shows that the appearance rates of pine trees per $100\textrm{m}^2$ at moor I and II were 0.28 and 0.57 respectively. And the number of younger pine trees(height is under 1.5m, DBH is less than 2.5 cm) invaded into moors are numbered eleven at the moor I, and ten at the moor II. This shows that the shift of a wetlands into a land was faster at the moor II than the moor I. The construction of a firebreak line and waterway along the moors I and II areas since the December, 1995, has diverted watershed flow and prohibited the runoff flow into the moors. The analysis of GIS suggests that the decreased watershed area were about $11,413.8\textrm{m}^2$(12.1 % of whole watershed area) at the moor I and $15,969.5\textrm{m}^2$(40.4 % of whole watershed area) at the moor II. The negative impact of firebreak line on the inflow of water into the moors I and II and destruction of vegetation along the firebreak line are noticeable from the field survey.

  • PDF