• Title/Summary/Keyword: 티타늄

Search Result 1,160, Processing Time 0.024 seconds

Characterization of Hydrogel Tinted Contact Lens Containing 4-iodoaniline using Titanium Silicon Oxide Nanoparticles as Additive (티타늄 실리콘 옥사이드 나노입자를 첨가제로 사용한 4-iodoaniline을 포함한 하이드로젤 착색 콘택트렌즈의 특성)

  • Cho, Seon-Ahr;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.315-322
    • /
    • 2014
  • Purpose: The physical and optical characteristics of hydrophilic tinted contact lens containing titanium silicon oxide nanoparticles and the basic hydrogel contact lens material containing 4-iodoaniline were examined. In this study, the utility of titanium silicon oxide nanoparticles as a UV-blocking material for ophthalmologic devices were investigated by measuring the UV transmittance of the produced polymer. Also, titanium silicon oxide nanoparticles only without the addition of 4-iodoaniline in primary contact lens materials by copolymerizing two groups were compared. Methods: For manufacturing hydrogel lens, HEMA, MA, MMA, 4-iodoaniline and a cross-linker EGDMA were copolymerized in the presence of AIBN as an initiator. Also, the titanium silicon oxide nanoparticles was used as additive. After polymerization the physical properties such as water content, refractive index, contact angle and spectral transmittance of produced contact lenses were measured. Results: Measurement of the physical properties of the copolymerized material showed that the water content, refractive index, UV-B transmittance and contact angle were in the range of 35.01~38.60%, 1.4350~1.4418, $34.15{\sim}57.25^{\circ}$ and 1.0~10.0%, respectively. Titanium silicon oxide nanoparticles is not used as an additive in the experimental group, the results of the measurement showed that the water content, refractive index, contan angle and UV-B transmittance of the hydrogel lens polymer was 34.00~36.80%, 1.4378~1.4420, $40.15{\sim}60.16^{\circ}$ and 1.8~25.0%, respectively. Conclusions: Also, the transmittance for UV light was reduced significantly in combinations containing titanium oxide nanoparticles.

Study of the Effect of Hydrazine Form and Titanium Electrode Condition on Reduction of Uranium(VI) n Nitric Acid (질산중의 우라늄(VI) 환원에 대한 하이드라이진 형태와 티타늄 전극상태의 영향연구)

  • Kim, K.W.;Lee, E.H.;Y.J. Shin;J.H. Yoo;Park, H.S.;Kim, Jong-Duk
    • Nuclear Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.425-432
    • /
    • 1994
  • Voltammogram analysis of U(VI) reduction at electrochemically non-pretreated/pretreated Ti electrodes in nitric acid and hydrazine($N_2$H$_4$)/protonated hydrazine($N_2$H$_{5}$$^{+}$) media was done in order to determine the effect of hydrazine form and Ti electrode condition on the reduction of U(VI) in nitric acid. In the case of non-pretreated Ti electrode, the reduction in nitric acid and hydrazine mono-hydrate solution needed a high activation overpotential and was affected by the ratio of hydrazine to nitric acid rather than by only absolute amount of hydrazine because of the decrease of solution conductivity and increase of iR drop, which were caused by proton consumption in the solution by the hydrazine. In the case of pretreated Ti electrode in nitric acid and protonated hydrazine solution, the reduction current peaks of U(VI) were clearer and higher enough to perform a kinetic analysis, compared with the case with the non-pretreated Ti electrode at the same potential, and the behavior was strongly affected by nitric acid. The presence of hydrazine was important in the reduction of U(VI) at the pretreated Ti electrode for preventing the reoxidation of U(IV), but the concentration of protonated hydrazine was not.t.

  • PDF

Changes in frictional resistance between stainless steel bracket and various orthodontic wires according to a change in moment (모멘트 변화에 따른 브라켓과 교정용 선재 사이의 마찰력 변화)

  • Jeong, Hye-Jin;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.37 no.2 s.121
    • /
    • pp.137-149
    • /
    • 2007
  • Objective: The purpose of this study was to compare changes in frictional resistance between the bracket and wire under dry and wet conditions according to a change in moment. Methods: A stainless steel bracket of $0.022"{\times}0.028"$ slot, and $0.019"{\times}0.025"$ stainless steel, beta-titanium, and nickel-titanium wires were used. A 10 mm length lever was attached to the test (sliding) brackets to generate a moment. The experimental model was designed to allow tipping until contacts were established between the wire and the mesiodistal edges of the bracket slot. The moment was generated by suspending a 100 g or 200 g weight on the end of the lever. The moments applied were $1000g{\cdot}mm\;(100g{\times}10mm)\;and\;2000g{\cdot}mm\;(200g{\times}10mm)$. The test brackets were ligated with elastomeric ligature for a constant ligation force and the fixed brackets were ligated with stainless steel ligature. Brackets were moved along the wire by means of an universal testing machine, and maximum frictional resistances were recorded. Results: Stainless steel wire showed least frictional resistance and there was no significant difference between beta-titanium and nickel-titanium except at $2000g{\cdot}mm$ moment in wet conditions. Frictional resistance of all wires increased as the moment increased from $1000g{\cdot}mm\;to\;2000g{\cdot}mm$. Under wet conditions, the frictional resistance of stainless steel wires increased in both $1000g{\cdot}mm\;and\;2000g{\cdot}mm$ moment conditions, but frictional resistance of nickel-titanium and beta-titanium increased only in $2000g{\cdot}mm$ conditions. Conclusion: These results indicated that various conditions influence on frictional resistance. Therefore, laboratory studies of frictional resistance should simulate clinical situation.

The Effect of Types of Abutment and Dynamic Loading on Microgap between Implant Fixture and Abutment (임플란트 지대주 종류와 동적하중이 고정체와 지대주의 미세간극에 미치는 영향)

  • Oh, Byung-Doo;Choi, Yu-Sung;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.389-403
    • /
    • 2010
  • Titanium and gold-alloy abutments have been used for a long-time in the clinical situations, but the use of zirconia abutments also increased. This study was designed to compare and evaluate the microgap differences according to types of abutment and dynamic loading. Titanium abutment, zirconia abutment and gold-alloy abutment (UCLA plastic) were connected into titanium implants of external hexagonal structure US II ${\phi}$ $3.75{\times}11.5$ mm (Osstem Co., Seoul, Korea) with the tightening torque of 30 Ncm. A sine type dynamic loading of 25-250 N and $30^{\circ}$ inclination from long axis was applied for $10^5$ times. Using the SEM both before and after the loadings, implant-abutment interfaces were analyzed on the labial, palatal, mesial and distal surface. The microgaps before and after the loading were compared, no statistically significant difference was observed caused by the dynamic loading on the labial, palatal, mesial or distal surface. Statistically significant difference was observed between UCLA and titanium group and between UCLA and zirconia group on both before and after the loading(p<0.05). No statistically significant difference was found between titanium and zirconia group. Loadings for $10^5$ times did not show significant effect to the microgaps between implants and abutments.

The Effects of Composition, Solvent Selectivity, and Additive on the Morphology of Hybrid Nano Thin Films Composed of Self-Assembled Block Copolymer and Titanium Dioxide (자기조립 블록공중합체와 이산화티타늄으로 구성된 하이브리드 나노 박막의 모폴로지에 미치는 고분자의 조성, 용매의 선택성 및 첨가제의 영향)

  • Jang, Yoon-Hee;Cha, Min-Ah;Kim, Dong-Ha
    • Polymer(Korea)
    • /
    • v.32 no.5
    • /
    • pp.465-469
    • /
    • 2008
  • Hybrid thin films composed of block copolymer(BCP) and $TiO_2$ with various morphologies on the nanoscale were fabricated using self-assembly of block copolymer combined with sol-gel process. The factors governing morphology changes considered in this study are block copolymer composition, selectivity of solvent and the inclusion of an additive. We also investigated the efficiency of photoluminescence for selected films with different morphologies. Micelle or nanowire structure can be derived from the self-assembly of poly (styrene-block-4-vinyl pyridine) (PS-b-P4VP) depending on the relative selectivity of the solvent for the two blocks, and the titanium tetraisopropoxide ($Ti{OCH (CH_3)_2}_4$, TTIP) is coordinated with nitrogen in P4VP block. Addition of a third component 3-pentadecylphenol into the BCP/sol-gel mixture solution induces morphology change as a result of the change of relative volume fraction of the BCP. We confirmed that the efficiency of $TiO_2$ fluorescence changes for films depending on morphologies.

Application of Silicon Sludge from Semiconductor Manufacturing Process as Pigments and Paints through Titanium Dioxide Coating (반도체 제조공정에서 발생하는 실리콘 슬러지의 이산화티타늄 코팅을 통한 안료 및 도료 소재로의 응용)

  • Yeon-Ryong Chu;Minki Sa;Jiwon Kim;Suk Jekal;Chan-Gyo Kim;Ha-Yeong Kim;Song Lee;Hyung Sub Sim;Chang-Min Yoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.3
    • /
    • pp.35-41
    • /
    • 2023
  • In this study, silicon sludge generated in semiconductor manufacturing process is recycled and applied as materials for pigments and paints. In detail, metallic impurities are removed from silicon sludge to obtain plate-like silicon sludge powder (SW-sludge), which is then coated with titanium dioxide via sol-gel method (TCS-sludge). SW-sludge and TCS-sludge are dispersed in hydrophilic transparent varnish and sprayed onto glass substrates to observe the possibility for the application as materials for pigments and paints. Notably, the applicability of TCS-sludge-based paint is improved compared to SW-sludge-based paint after the titanium dioxide coating. Moreover, the color of TCS-sludge-based paint turns into white. Accordingly, it is confirmed that the applicability and hydrophilicity are improved by the presence of outer titanium dioxide layer. In this regard, it is expected that the recycled TCS-sludge may be a future material for the application as pigments and paints.

Generation of high-power sub-10-fs optical pulses at 1-kHz repetition rate (1 kHz로 동작하는 10 펨토초 미만의 고출력 펄스의 발생)

  • 성재희;홍경한;남창희
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.226-227
    • /
    • 2002
  • 처프펄스증폭(CPA) 개념을 이용한 티타늄 사파이어 레이저는 고출력 펨토초 펄스 생성에서 표준적인 시스템이며, 현재 수 kHz의 반복률에서 TW 급의 출력을 가지는 시스템들이 개발되어 사용 중이다.(1) 그러나 증폭시에 나타나는 티타늄 사파이어 레이저 매질에서의 이득 좁아짐 효과 때문에 얻어지는 최소 펄스폭은 20 펨토초 수준으로 제한된다. 이러한 스펙트럼폭의 한계를 극복하기 위하여 hollow-fiber에서의 자체위상변조(SPM) 현상을 이용하여 500 nm 이상의 파장 영역에 걸친 continuum을 발생시키는 기술이 제안되었다. (중략)

  • PDF

Tool wear monitoring of end mill in slot machining of titanium alloy (티타늄 합금의 슬롯가공에서 엔드밀 공구마멸 감시)

  • 하건호;구세진;김정석;양순철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.101-104
    • /
    • 1995
  • A acoustic emission (AE) sensor has been used to monitor tool were during milling process. The relation between tool wear and AE RMS (Root mean Square) signal was investigated experimentally. A avaliable monitoring index for monitoring toolwear was newly extracted form AE RMS. And on-line monitoring program was developed. The proposed monitoring system has verified experimentally by roughing end milling titanium alloy with TIN coated HSS tool.

  • PDF

형상기억합금의 특성 및 응용

  • Lee, In;Yang, Seung-Man
    • Journal of the KSME
    • /
    • v.44 no.6
    • /
    • pp.34-39
    • /
    • 2004
  • 형상기억합금(SMA : Shape Memory Alloy)은 일반적인 금속이나 합금에서는 찾아볼 수 없는 형상기억효과(shape memory effect)와 초탄성 (superelasticity) 거동을 보이고 있다. 이러한 특성은 1951년에 금-카드뮴(Au-Cd) 합금에서 처음으로 발견되었으며, 1963년에 미국 해군병기연구소(Naval Ordnance Laboratory)에서 니켈-티타늄 (Ni-Ti) 합금에서 형상기억효과를 발견한 후로 널리 상용화되었다. 니티놀(nitinol)이라고 불려지는 니켈-티타늄 계열의 형상기억합금은 단위 부피당 많은 에너지를 낼 수 있고, 내 부식성(corrosion resistance)과 생화학적 적합성(bio-compatibility)이 뛰어나다. 또한 100,000사이클 이상의 긴 사용수명을 갖기 때문에 작동기(actuator)로서 우수한 특징을 갖는다. (중략)

  • PDF

보급형 He-Ne 타원해석기의 제작과 $TiO_2$ 박막 유효밀도 변화의 in situ 측정

  • 김상준;방현용;김상열
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.101-101
    • /
    • 1999
  • 실시간으로 변화하는 시료를 측정하고 분석할 수 있도록 비접촉시이며, 광학방식인 단파장 in situ 타원해석기를 제작하였다. He-Ne 레이저를 광원으로 사용하였고 회전편광자형 광량 측정방식을 채택하였다. 기존의 진공챔버 등에 쉽게 장착할 수 있도록 동축 구조를 사용하였으므로 소형이며 단순한 설계가 가능하였다. 전자빔 증착방법으로 성장시킨 조밀도가 82%인 이산화티타늄 박막의 분석에 이 타원해석기를 사용하여 수분탈착에 따르는 이산화티타늄 박막의 유효밀도 변화를 박막의 온도 변화와 시간 변화에 따라 실시간 in, situ방식으로 관측하였다.

  • PDF