• Title/Summary/Keyword: 튜브펌프

Search Result 45, Processing Time 0.03 seconds

Micro Tube Pump for an Implantable Drug Infusion Device (이식형 약물 주입 장치용 마이크로 튜브 펌프)

  • Bach, Du-Jin;Park, Jun-Woo;Lee, Duck-Hee;Lee, Chul-Han;Hong, So-Young;Jo, Yung-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.1
    • /
    • pp.40-45
    • /
    • 2008
  • This paper proposes a tube pump composed of small-sized cams and followers for an implantable intrathecal drug infusion device. Each followers is driven by a cam and liquid is discharged by a sequential reciprocal motion of the followers. The advantage of this structure is that it allows the pump to be clean and valveless. To design a small-sized, low power pump some analysis were performed to determine the design parameters of the cam, follower and the tube. To verify the feasibility of the experiment, a prototype was manufactured and its operating characteristics were investigated. Experimental results were in accordance with the expected results obtained from analysis.

Development of a New Heat Exchanger for the Super Cooling (HESC) to Enhance the Performance of the Heat Pump System for the Living Space by the Natural Energy (자연에너지를 이용한 생활공간 냉난방용 열펌프의 성능향상을 위한 과냉 촉진 신개념 열교환기(HESC) 개발)

  • Song, Heon
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.40-48
    • /
    • 2011
  • 과냉 촉진을 위한 새로운 열교환기(HESC)가 생활공간의 냉난방을 위한 공기-물 열펌프의 성능계수 향상을 위해 본 연구에서 개발되었으며 그 효과를 실험적으로 분석하였다. 이 열교환기(HESC)는 여러 단계의 셀과 튜브로 구성되어 있으며, 열펌프 시스템의 응축기와 증발기 사이에 장착되었다. 실험 조건으로, 외기온은 $7^{\circ}C$에서 $-17^{\circ}C$, 입구 물 온도는 $7{\sim}10^{\circ}C$ 그리고 제 2열전달매체로서 물의 질량 유동율은 시간당 100에서 $300{\ell}$로 변화를 주었다. 본 실험에서 이 열교환기가 장착된 열펌프의 압축기에서의 냉매 입 출구 사이의 온도 차이는 열교환기가 장착되지 않은 열펌프보다 $15^{\circ}C$ 높았다. 이에 따라 이 열교환기가 장착된 열펌프 시스템은 외기온 $-10^{\circ}C$에서 COP가 0.8 증가하였다. 따라서 이 공기-물 열펌프 시스템은 최근 한국에서 실용화되고 있는 고비용이 요구되는 지열 열펌프 시스템을 대체하여 생활공간을 위한 냉난방 시스템으로서 중요한 역할을 할 수 있을 것으로 사료된다.

Probabilistic Study on Pressure Behavior in Concrete Vacuum Tube Structures (콘크리트 진공튜브의 압력 변화에 대한 확률적 평가)

  • Park, Joonam
    • Journal of the Korean Society for Railway
    • /
    • v.17 no.3
    • /
    • pp.186-192
    • /
    • 2014
  • In this paper, a reliability analysis is performed where the pressure change inside a concrete tube is probabilistically estimated considering the uncertainties inherent in the material and the system discontinuity. A set of uncertain quantities related to the equivalent system air permeability and the atmospheric pressure, are defined as random variables with specific distribution. The pressure change inside a concrete tube is then probabilistically described using both analytical and simulation approaches. The reliability analysis confirms that the geometric configuration of a concrete tube needs to be changed from the initial configuration obtained from the deterministic analysis.

Decreasing the Turbine Power Based on the Number of Circulation Water Pumps in Nuclear Power Plants (순환수펌프의 작동수를 고려한 원전터빈 출력조정)

  • 진수환;명효형;진명길;김성준
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2002.05a
    • /
    • pp.240-247
    • /
    • 2002
  • 복수기의 원활한 열교환에 필요한 냉각수를 공급하기 위해 순환수펌프는 해수를 끌어들이는 역할을 한다. 각종 해양생물이나 이물질 등으로 인해 순환수펌프의 작동이 멈추는 경우가 간헐적으로 발생하고 있는 데, 이렇게 되면 복수기 튜브 쪽으로 유입되는 순환수 유량은 정상상태보다 줄어들게 된다. 이를 무시하고 원전터빈을 계속 고출력으로 가동시키면 복수기 내부의 전공도가 악화되어 작동이 정지되는 상황을 맞을 수 있으므로 터빈출력을 적정한 수준으로 낮추는 작업이 필요하다. 본 연구는 순환수펌프의 작동수 및 해수온도를 고려하여 터빈의 적정출력을 산정하고 이를 도표화하여 제시하였다. 분석결과를 기존의 운전데이터와 비교검토한 결과 대체로 일치하고 있어 운전조건을 안정적으로 유지하는 데 도움이 될 전망이다.

  • PDF

Evaporation Heat Transfer and Pressure Drop of R-410A in a 7.0 mm O.D. Microfin Tube at Low Flow Rates (낮은 유량에서 외경 7.0 mm 마이크로핀 튜브 내 R-410A 증발 열전달 및 압력 손실)

  • Kim, Nae-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.9
    • /
    • pp.761-772
    • /
    • 2015
  • Microfin tubes having an outside diameter (O.D.) of 7.0 mm are widely used in residential air conditioning systems and heat pumps. It is known that the mass fluxes for air conditioners and heat pumps under partial load conditions are several tens of $kg/m^2s$. However, literature surveys reveal that previous investigations were limited to mass flux over $100kg/m^2s$. In this study, we conduct R-410A evaporation heat-transfer tests at low mass fluxes ($50-250kg/m^2s$) using a 7.0 mm O.D. microfin tube. During the test, the saturation temperature was maintained at $8^{\circ}C$, and the heat flux was maintained at $4.0kW/m^2$. For comparison purposes, we also test a smooth tube with a 7.0 mm O.D. The results showed that the heat-transfer enhancement factor of the microfin tube increased as the mass flux decreased up to $150kg/m^2s$, which decreased as the mass flux further decreased. The reason for this was attributed to the change of the flow pattern from an annular flow to a stratified flow. Within the test range, the frictional pressure drops of the microfin tube were approximately the same as those of the smooth tube. We then compare experimental data obtained with the predictions obtained for the existing correlations.

Air-tightness Evaluation of Tube Structures for Super-speed Tube Railway Systems: I. Analytical Modeling and Material Test (초고속 튜브철도 시스템을 위한 튜브 구조물의 기밀성 평가 : I. 해석모델 수립 및 재료 기밀성)

  • Park, Joo-Nam;Nam, Seong-Won;Kim, Lee-Hyeon;Yeo, In-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.2
    • /
    • pp.143-150
    • /
    • 2011
  • This paper presents a preliminary study for air-tightness evaluation of vacuum tube structures for super-speed tube railway systems. The formula for flow rate of the air caused by the pressure difference of the inside and outside of the tube structure is derived based on Darcy's law. A test is then performed to measure the air-permeability of concrete with various compressive strengths, the result of which is used for analytical simulation of the air intrusion for a tube structure with a preliminarily defined section. It has been shown that concrete with the compressive strength of at least more than 50MPa is recommended for effective operation and maintenance of the vacuum pump systems, as the air-permeability of concrete is inversely proportional to the exponent of its compressive strength.

초고진공 펌프개발 -크라이오 펌프와 진공 브레이징의 이해-

  • Yu, Jae-Gyeong;Gang, Min-Jeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.13-13
    • /
    • 2010
  • 개요- 반도체 시장의 확대 및 소자의 고집적화와 장비의 초정밀화 등 고정도 생산성을 요구하는 현대 진공산업 시장에서는 정밀한 제품을 대량으로 생산할 수 있도록 지원할 수 있는 대용량 장비의 수요가 급증하고 있다. 서론- 하루가 다르게 발전하는 기술 경쟁 사회에서는 보다 성능이 좋은 제품을 다른 국가 또는 다른 업체와 차별화된 기술적 우위를 선점해야 한다. 본문-이에따라, 고신뢰도, 고생산성이 요구되는 진공산업 시장에 발맞추기 위한 일환으로 크라이오 펌프의 재생시간을 단축시켜 생산성 향상을 높이고, 기존의 제품에서 소비자가 느꼈던 진동을 최소로 줄일 수 있도록 저진동 제품의 설계를 통한 고객 만족의 제품을 개발함과 동시에, 맥동관 냉동기의 기술상업화를 꾀한 극저온기술 영역의 발전을 함께 도모하고자 한다. 현재까지는 국내의 일부 정부출연 연구소와 학교, 일부 특수산업 분야에서만 크라이오 펌프를 사용하고 있으나, 상업적인 설계 및 생산은 완전히 전무한 상태이다. 이는 진공시장의 잠재적인 성장을 고려할 때 국산화가 시급한 상황이다. 이러한, 상황을 고려하여 현재 기계연구원과 우성진공, 국민대학교가 맥동관 냉동기를 접목시킨 급속재생형 저진동 크라이오 펌프를 지난 2008년부터 산학연 협동으로 개발 진행 중에 있다. 크라이오 펌프의 핵심 기술은 냉동기의 효율에 있다고 볼 수 있으며, 이러한 냉동기의 효과를 높이기 위하여, 제작 공정에 진공 브레이징을 사용하여, 열교환기와 교환기 내의 충진재들과의 정확한 간극을 유지하면서 접합을 할 수 있는 환경요건을 지속적인 실험을 통해 지식을 습득하고 있다. 진공 브레이징은 외관을 아름답고 정교하게 접합할 수 있으므로, 추후 상품으로의 가치를 높일 수 있으며, 서로 다른 이종금속 간의 접합이 가능하여 열교환기의 무산소동과 스테인레스 튜브와의 접합을 가능하게 할 수 있었다. 진공브레이징에 쓰이는 모재는 여러가지가 있으며, 접합의 환경 또한 일반 용접보다 다양하므로 여러번의 실험을 통한다면, 성능은 우수하면서 외관으로 손색이 없는 개발품이 나올수 있겠다는 의견이 모아지고 있는 중이다. 본론- 아직까지는 미국의 CTI사나 일본의 ULVAC 등의 크라이오 펌프의 선진 기업에 비해 기술력이 많이 부족하기는 하지만, 아직 많은 부분이 미개발된 분야이고, 향후 후발국과의 차별을 두어 선진기술을 확보하기 위해서는 기존의 방식을 단순히 따라하는 것이 아닌 남들과 다른 원천기술의 확보가 더 필요하며, 이를 위해 부단한 노력과 시행착오를 거쳐 맥동관 냉동기형 크라이오 펌프라는 기술을 확보할 예정이다.

  • PDF