• Title/Summary/Keyword: 튜브간격

Search Result 66, Processing Time 0.028 seconds

Installation Technology and Behavior of Silty Clay Filled Geotextile Tube (실트질 점토 채움 시 지오텍스타일 튜브의 거동 및 시공 방법에 관한 연구)

  • Shin, Eun-Chul;Oh, Young-In
    • Journal of the Korean Geosynthetics Society
    • /
    • v.1 no.1
    • /
    • pp.13-21
    • /
    • 2002
  • Geotextile tubes hydraulically or mechanically filled with dredged materials have been applied in hydraulic and coastal engineering in recent years(detached breakwater, groins and jetty). The geotextile tubes are made of sewn geosynthetics sheets. If the sandy soil is use to fill material, these inlets should be spaced closely to assure uniform filling of the tubes because sandy soil and geosynthetic is very pervious. However, the clayey soil or contaminated slurry is used, the inlets can be located relatively long distance. The fine clayey particles tend to rapidly blind the fabric slowing down water escape through the geotextile. This paper presents a field test result of a geotextile tube in the land reclamation project for the Songdo New City construction site. The dredged silty clay was dredged by the dredging ship and hydraulically pumped into the geotextile tube. The height of geotextile tube was measured at every filling stage and also measured width and diameter of geotextile tube with the elapsed time. Based on the test results, if the clayey filling material is used, the pumping step must be divided 3~4 stages for drainage and sediment. After complete drainage, the height of the geotextile tube reduces by approximately 50%.

  • PDF

Development of Numerical Computation Techniques for the Free-Surface of U-Tube Type Anti-roll Tank (U-튜브형 횡동요 감쇄 탱크의 자유수면 해석기법 개발에 관한 연구)

  • Sang-Eui Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.7
    • /
    • pp.1244-1251
    • /
    • 2022
  • Marine accidents due to a loss of stability, have been gradually increasing over the last decade. Measures must be taken on the roll reduction of a ship. Amongst the measures, building an anti-roll tank in a ship is recognized as the most simple and effective way to reduce the roll motion. Therefore, this study aims to develop a computational model for a U-tube type anti-roll tank and to validate it by experiment. In particular, to validate the developed computational model, the height of the free surface in the tank was measured in the experiment. To develop a computational model, the mesh dependency test was carried out. Further, the effects of a turbulence model, time step size, and the number of iterations on the numerical solution were analyzed. In summary, a U-tube type anti-roll tank simulation had to be performed accurately with conditions of a realizable k-𝜖 turbulence model, 10-2s time step size, and 15 iterations. In validation, the two cases of measured data from the experiment were compared with the numerical results. In the present study, STAR-CCM+ (ver. 17.02), a RANS-based commercial solver was used.

Comparison of Heat Transfer Performance and Pressure Drop of Fin-Tube and Aluminum Heat Exchangers (핀-튜브 열교환기와 알루미늄 열교환기의 전열성능과 압력강하 특성비교)

  • Chang, Keun-Sun;Lee, Hyun-Su;Kim, Jae-Duck
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.2
    • /
    • pp.222-229
    • /
    • 2009
  • This study presents comparison of heat transfer and air side friction characteristics in a condenser condition of air conditioner between Louver fin-tube heat exchangers and aluminum parallel heat exchangers. All experiments are performed using an air-enthalpy type calorimeter, which is designed based on the method described in ASHRAE standards. The air velocities crossing the heat exchanger tubes are varied from 0.7 to 1.6 m/s with 0.3 m/s interval, maintaining air dry temperature and relative humidity at $20^{\circ}C$ and 60% respectively. Water temperature and flow rate inside the tube are $70^{\circ}C$ and 10 LPM, respectively. Experimental results show that the heat transfer performances of aluminum heat exchangers are 17-163% higher than those of Louver fin-tube heat exchangers based on the data per unit volume, mass, and heat transfer area, whereas air side pressure drops of aluminum heat exchangers are 19-81% lower.

A study on the sound transmission through double plates installed inside an impedance tube (임피던스 튜브 내에 설치된 이중 평판의 음파투과연구)

  • Kim, Hyun-Sil;Kim, Bong-Ki;Kim, Sang-Ryul;Seo, Yun-Ho;Ma, Pyung-Sik
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.4
    • /
    • pp.253-260
    • /
    • 2016
  • In this paper, derivation of the STL (Sound Transmission Loss) of the double plates installed in an impedance tube is discussed using an analytic method, where an air cavity exists between the plates. Vibration of the plates and sound pressure field inside the tube are expressed in terms of infinite series of modal functions. Under the plane wave assumption, it is shown that consideration of the first few modes yields sufficiently accurate results, and locations of peaks and dips are investigated. It is determined that the peak frequencies of the double plates coincide with those of each single plate. When the two plates are identical, the STL of the double plates as well as that of the single plate become zero at the natural frequencies of the single plate. The location and amplitude of the dips are investigated using an approximation solution when the cavity depth is very small.

A Study on the Back Flow of Urine into the Ceca in Chicken (닭에서 맹장으로 역류하는 뇨(尿)에 관한 연구)

  • Son, Jang-Ho
    • Korean Journal of Poultry Science
    • /
    • v.30 no.4
    • /
    • pp.269-273
    • /
    • 2003
  • A cecostomy technique (surgery for inserted tube into ceca) was developed to quantify urine backflow into the ceca of fed and feed-deprived chickens. Two days post-surgery, cecostomised chickens were flushed with 20ml of warm saline solution every other day for 10 days. Excreta were collected daily from cecal tubing and cloaca by surgical attachment of polyethylene collection vessels to the chickens. Uric acid excretion was significantly increased in fed compared to feed-deprived chickens (P<0.05). Amount of determined uric acid from the ceca was 7.74% and 5.31% of total excretion for fed and ffeed-deprived chickens, respectively. Post-mortem examinations ascertained that the caeca were intact around the Latex tubing. The results of the study indicated that at least 5% of daily urine production flow retrograde into the ceca of roosters.

Field Emission Properties of Multiwalled Carbon Nanotubes Synthesized by Pin-to-Plate Type Atmospheric Pressure Plasma Enhanced Chemical Vapor Deposition (Pin-to-plate Type 대기압 PECVD 방법을 이용해 성장된 다중벽 탄소나노튜브의 전계방출 특성연구)

  • Park Jae-Beom;Kyung Se-Jin;Yeom Geun-Young
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.4
    • /
    • pp.374-379
    • /
    • 2006
  • In this study, carbon nanotubes (CNTs) were grown on glass substrates coated with Ni/Cr by an atmospheric pressure plasma enhanced chemical vapor deposition(AP-PECVD) and their structural and electrical characteristics were investigated as a possible application to the field emitter of field emission display (FED) devices. The substrate temperature ($400{\sim}500^{\circ}C$) were varied and the grown CNTs were multi wall CNTs (at $500^{\circ}C$, 15 - 20 layers of graphene sheets, distance of each layer : 0.3nm, inner diameter: 10 - 15nm, outer diameter: 30 - 40nm). The ratio of defective carbon peak to graphite carbon peak of the CNTs grown at $500^{\circ}C$ (C measured by fourier transform(FT)-Raman was 0.772 $I_D / I_G$ ratio. When field emission properties were measured, the turn-on field was $2.92V/{\mu}m$ and the emission field at $1mA/cm^2$ was $5.325V /{\mu}m$.

Effect of Centrifugal Casting Thickness on the Mechanical Properties and the Microstructure of Alloy 625 (Alloy 625의 특성과 조직에 미치는 원심주조품 두께의 영향)

  • Lee, Yu-Jung;Kim, Byung-Hoon;Joo, Yun-Kon;Jo, Chang-Yong;Lee, Je-Hyun
    • Journal of Korea Foundry Society
    • /
    • v.42 no.3
    • /
    • pp.153-160
    • /
    • 2022
  • The effect of thickness on the microstructure and the mechanical properties of centrifugal cast 625 was investigated. Centrifugal cast 625 with various thickness of 10, 17 and 50mm showed partially columnar grained structure 8, 12.3 and 18.5mm respectively from the outer surface. Secondary dendrite arm spacing in the columnar grains slightly increased with increasing casting thickness. Tensile strength of the columnar region was similar regardless of casting thickness. Solidification behavior of the columnar grained region is similar to that of directional solidification, thus solidification rate in the centrifugal cast tube was extrapolated from the secondary dendrite arm spacing data of the directionally solidified material. The equiax grained region formed interior of the thick castings. The tensile strength of the equiaxed region showed the average value of the columnar region which is presumably originated from the grain structure rather than secondary dendrite arm spacing.

Development of Conductivity Cell and Suppressor for Capillary Column Ion Chromatography (모세관 컬럼 이온 크로마토그래피를 위한 Conductivity Cell과 Suppressor의 개발)

  • Pyo, Dongjin;Kim, Hohyun
    • Analytical Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.89-93
    • /
    • 1999
  • In this study, conductivity cell and suppressor for micro-column ion chromatography were developed to analyze ions in small columns of samples. With a capillary column, the flow rate of the mobile phase is so small (usually $5{\sim}20{\mu}L/min$) that the usual conductivity cell can not be used. Therefore, we developed a new type of conductivity cell and suppressor which have small inner volumes. The conductivity cell was made with two Pt hypodermic needles (i.d. 0.010 mm) which are slightly separated (about $2{\mu}m$), and the suppressor was made of Nafion tubings. When several anions(fluoride, nitrite, nitrate, chlorate) were analyzed using developed conductivity cell and suppressor, a good chromatogram was obtained.

  • PDF

Field effect and temperature dependence on the conductance of the carbon nanotube network (홑겹 탄소 나노튜브 네트워크의 게이트 의존성과 온도 의존성)

  • Oh, Dong-Jin;Won, Boo-Ne;Kim, Kang-Hyun;Kang, Hae-Yong;Kim, Hye-Young;Kim, Gyu-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.147-150
    • /
    • 2004
  • Back gate가 있는 $SiO_2$ 기판에 SWCNT(Single Walled Carbon Nanotube) 분산액을 도포하여 SWCNT 네트워크를 형성하였다. 금선을 shadow mask로 사용하여 $10{\mu}m$ 간격의 2단자 금 전극을 열 증착을 통해 형성하였다. 현미경 포토리소그래피를 통하여 시료의 가장자리를 Photoresist로 남겨두어 시료 가장자리의 나노튜브를 통한 단락을 방지하였다. 전류-전압 특성, 게이트 특성과 온도 의존성은 DAQ(Data Aquisition) 보드와 Keithley 2400을 사용하여 측정하였고, Labview 기반 프로그램을 통해 제어하였다. 음의 게이트 전압에서의 저항 감소를 관측함으로써 네트워크 상태에서의 게이트 의존성이 P 형 반도체 성질을 보여줌을 알 수 있었으며, 온도가 올라감에 따라 저항이 지수 함수적으로 증가하는 것으로부터 네트워크의 온도 의존성이 금속성 온도 의존성을 가지는 것을 확인하였다.

  • PDF

Experimental Study on the Heat Transfer Characteristics of Spiral Fin-Tube Heat Exchangers (나선형 핀튜브 열교환기의 열전달 특성에 관한 실험적 연구)

  • Yun Rin;Kim Yongchan;Kim Sru;Choi Jong Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.6
    • /
    • pp.529-535
    • /
    • 2005
  • This study experimentally examines the air-side performance of spiral finned tube heat exchangers. The effects of fin spacing, fin height, and tube alignment were investigated. Reduction of fin spacing decreased the Colburn j factor. However, the effect of fin height on the Colburn j factor was negligible. An increase of tube row decreased the Nusselt number for both staggered and in-line tube alignments. However, the decrease of the Nusselt number for the in-line tube alignment was much more significant than that of the staggered tube alignment. The average Nusselt number of the staggered tube alignment was larger than that of the in-line tube alignment by $10\%$ when the Reynolds number ranged from 300 to 1700. An empirical correlation of the Nusselt number was developed by using geometric parameters of heat exchanger and correction factors. The correction factor considered the effects of tube alignment and number of tube rows on the heat transfer. The proposed correlation yielded a mean deviation of $4\%$ from the present data.