• Title/Summary/Keyword: 투수속도

Search Result 165, Processing Time 0.027 seconds

Simulation of Groundwater Flow in Fractured Porous Media using a Discrete Fracture Model (불연속 파쇄모델을 이용한 파쇄 매질에서의 지하수 유동 시뮬레이션)

  • Park, Yu-Chul;Lee, Kang-Kun
    • Economic and Environmental Geology
    • /
    • v.28 no.5
    • /
    • pp.503-512
    • /
    • 1995
  • Groundwater flow in fracture networks is simulated using a discrete fracture (DF) model which assume that groundwater flows only through the fracture network. This assumption is available if the permeability of rock matrix is very low. It is almost impossible to describe fracture networks perfectly, so a stochastic approach is used. The stochastic approach assumes that the characteristic parameters in fracture network have special distribution patterns. The stochastic model generates fracture networks with some characteristic parameters. The finite element method is used to compute fracture flows. One-dimensional line element is the element type of the finite elements. The simulation results are shown by dominant flow paths in the fracture network. The dominant flow path can be found from the simulated groundwater flow field. The model developed in this study provides the tool to estimate the influences of characteristic parameters on groundwater flow in fracture networks. The influences of some characteristic parameters on the frcture flow are estimated by the Monte Carlo simulation based on 30 realizations.

  • PDF

Groundwater flow Analysis Using MODFLOW in the Tunnel (MODFLOW를 이용한 터널의 지하수 유동해석)

  • Hue, Chang-Hwan
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.1
    • /
    • pp.129-142
    • /
    • 2003
  • In this study, the conduct of underground water flow system with 3 dimensions is interpreted in order to examine closely the actual condition regarding the flow of the underground water which is forecast from the tunnel segment and the interpretation result which selects the design and the construction technique of the tunnel segment was applied. Also, an obstacle to construct that relates with the underground water flow in construction duration in advance will be able to apply with information that is necessary in order to establish the countermeasure. The objective tunnel is the BEOPGI tunnel segment that is 2 parallel tunnels that are a one-way 2 lane and the parameters of the MODFLOW model executing the boring investigation and the permeability examination were presumed. The underground water flow of the excavation tunnel inside was interpreted by the MODFLOW model using the parameters which is presumed and two values which compared with calculated value and observed value are the same almost. Also, when the underground water discharge quantify that followed in tunnel excavation tries to compare, the underground water total discharge quantity from tunnel point of start until destination was presumed as 0.0269㎥/day/$m^2$.

Manual Development for Korean Low Impact Development Factility Maintenance (한국형 저영향시설(LID) 유지관리 매뉴얼 개발)

  • Lee, Inhwa;Ahn, Jeahwang;Yu, Myungsu;Yi, Jaeeung;Kang, Jisook
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.602-602
    • /
    • 2016
  • 우리나라에서는 1960년대부터 현재까지 도시화가 급속도로 진행되고 있다. 도시화가 진행됨에 따라 대부분 농경지로 사용되었던 토지의 이용 방법이 변화하였고 포장면적이 증가하면서 불투수면적과 강우유출량 또한 증가하였다. 이러한 현상으로 인해 도심지의 유출량이 증가하여 도심홍수가 빈번해지고, 비점오염물 증가로 인한 수질악화 등의 환경 문제가 더욱 심화되고 있다. 따라서 도시화로 인한 피해를 저감시키고 물순환 체계를 효율적으로 관리하기 위한 저영향개발(LID, Low Impact Development) 기법의 필요성이 대두되고 있으며, 그로 인해 LID 기법의 가치가 재조명되고 있다. 현재 LID 기법과 관련된 많은 연구가 진행되고 있지만 LID 시설물에 대한 이해와 유지 관리 필요성에 관한 연구가 미흡한 실정이다. 따라서 본 연구에서는 LID 기법을 보다 쉽고 효율적으로 적용하기 위해 국내 9종의 매뉴얼과 국외 2종의 매뉴얼을 검토하여 국내 실정에 적합한 LID 시설 유지관리 기법을 고안하여 LID 개념을 통합적으로 정립하였으며 LID와 관련된 시설물, 모니터링 요소, 유지관리 등의 기술적인 정보를 제공하기 위한 한국형 LID 시설유지관리 매뉴얼을 작성하였다. 매뉴얼은 첫째, LID 전반적인 이해를 돕기 위해 LID 정의, LID 시설물의 종류, 설치기준 및 운영 관리기준에 대한 내용을 다루고 둘째, LID 시설물의 특징, 구성, 설치가능 지역, 설치 시 고려사항, 유지관리 기법, 설치 예에 대한 내용으로 구성하였으며 이외에도 시설물의 일반적인 점검사항, 토지이용별 고려사항 등 시설물 설치 후 점검 방법, 유의사항 등을 제시하였다. 향후 매뉴얼의 타당성을 검토하기 위해 부산대학교 양산캠퍼스에 완공된 LID 실증단지의 시범 LID 시설물에 적용하여 국내 LID 시설물에 대한 매뉴얼의 적용성을 높일 예정이다.

  • PDF

Sensitivity analysis of hydrogeologic characteristics for recharge and discharge rates assessment in the artificial recharge site (인공함양 주입량-양수량 평가를 위한 수리지질특성 민감도 분석)

  • Kang, Dong-hwan;So, Yoon-hwan;Park, Ho-seon;Kim, Byung-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.387-387
    • /
    • 2017
  • 인공함양 시설을 설계 및 운영하는 단계에서 설치 예정부지의 자연적 특성(지형, 지질, 기후 등)과 인공적 특성(주입정과 양수정의 거리, 주입량, 양수량 등)은 중요한 인자라고 볼 수 있다. 인공함양 예정 부지의 개념모델을 설정하고 수리전도도와 이격거리(주입정과 양수정의 직선거리)에 대한 민감도 분석을 수행하였다. 인공함양 예정 부지는 충적대수층이며, 인공함양 주입량과 양수량은 $150m^3/day$로 동일하게 설정하였다. HydroGeoSphere 모델링을 통한 민감도 분석은 수리전도도($10^{-1}cm/sec$, $10^{-2}cm/sec$, $10^{-3}cm/sec$, $10^{-4}cm/sec$)와 이격거리(10 m, 50 m, 100 m) 조건에 대해 총 12회 수행하였다. 수리전도도가 $10^{-1}cm/sec$$10^{-2}cm/sec$인 경우의 모델링 결과, 이격거리가 100 m 범위 이내에서는 지하수위 변동이 발생하지 않았다. 수리전도도가 $10^{-3}cm/sec$인 경우의 모델링 결과, 이격거리가 10 m일 때 5 m 이내의 수위하강이 발생하고 영향반경은 약 14 m 정도로 나타났고, 이격거리가 50 m일 때 5 m 이내의 수위하강이 발생하고 영향반경은 약 31 m 정도로 나타났고, 이격거리가 100 m일 때 5 m 이내의 수위하강이 발생하고 영향반경은 약 34 m 정도로 나타났다. 수리전도도가 $10^{-4}cm/sec$인 경우의 모델링 결과, 이격거리가 증가할수록 양수에 의한 수위하강과 영향반경이 증가하였으며, 낮은 수리전도도로 인해 양수로 인한 수두손실을 회복할 수 없었기에 양수정 주변에서 반경 수십 m 이상의 수두하강 영역을 형성하고 주입정 근처에서는 주입속도가 대수층의 투수능력에 비해 상당히 높기 때문에 5 m 정도의 수위상승이 나타났다. 모델링 결과를 분석하여, 수리전도도가 $10^{-3}cm/sec$ 이하이고 이격거리가 10 m 범위 이상인 충적대수층에 $150m^3/day$를 주입하면서 동시에 $150m^3/day$를 양수하는 시스템에서는 지하수위변동이 발생하므로 주입량과 양수량의 조절이 필요하다는 것을 확인하였다.

  • PDF

Evaluation of Dissipation Behavior of Excess Pore Pressure in Liquefied Sand Deposit Using Centrifuge Tests (원심모형실험을 이용한 액상화 모래지반의 과잉간극수압 소산거동 분석)

  • Kim Sung-Ryul;Ko Hon-Yim;Kim Myoung-Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.1
    • /
    • pp.53-61
    • /
    • 2006
  • Soil liquefaction occurs by complex dynamic interaction between soil particles and pore fluid. Therefore, experimental researches have been widely performed to analyze liquefaction phenomena. In this research, centrifuge tests were performed to analyze the liquefaction behavior of horizontal sand ground. Centrifugal acceleration was 40g and the thickness of model ground was 25cm, which simulates 10m thickness in prototype scale. Viscous fluid was used as pore fluid to remove the time scaling difference between dissipation and dynamic shaking. Test results showed that the dissipation of excess pore pressure is the combined behavior of solidification and consolidation. In addition, the solidification rate, the ground acceleration amplitude, and the dynamic permeability during solidification were influenced by the confining pressure.

Behaviour of the Excess Pore Pressure Induced by Sand Mat on the Soft Clay (점토지반 샌드매트의 간극수압 거동)

  • Kim, Hyeong-Joo;Lee, Min-Sun;Paek, Pil-Soon;Jeon, Hye-Sun
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.8
    • /
    • pp.55-62
    • /
    • 2006
  • The design of sand mat should be reviewed by the behaviour of excess pore pressure which is obtained by combining characteristics of soft ground with the permeability of sand mat. In this paper, in order to investigate the distribution of hydraulic gradient of sand mat, a banking model test was performed using dredged sand as materials of sand mat, and these results were compared by the numerical analysis results utilizing Terzaghi's consolidation equation. The results show that the pore pressure was influenced by the settlement increasing in the central area of sand mat as the height of embankment increases, and uprising speed of excess pore pressure due to residing water pressure is delayed compared with the results of numerical analysis. Finally, the construction of sand mat should be spreaded to reduce the increased hydraulic gradient at the central area of embankment.

Analysis of the Correlation between Geological Characteristics and Water Withdrawals in the Laterals of Radial Collector Well (방사형집수정의 수평집수관에서 지질특성과 취수량의 상관관계 분석)

  • Kim, Tae-Hyung;Jeong, Jae-Hoon;Kim, Min;OH, Se-Hyoung;Lee, Jae-Sung
    • The Journal of Engineering Geology
    • /
    • v.24 no.2
    • /
    • pp.201-215
    • /
    • 2014
  • This study was performed to investigate the correlation between hydraulic conductivity and the flow rate of an aquifer, with the flow rate calculated from the laterals of the radial collector well using data obtained by the development project of riverbank filtration (Second Phase) in Changwon City. The hydraulic conductivity was empirically calculated from unconsolidated sediments collected from a sandy gravel layer along the middle-to-downstream sections of the Nakdong River. The Beyer equation produced the most suitable hydraulic conductivity from the various empirical formulas employed. The calculated hydraulic conductivity ranged from 0.083 to 0.264 cm/s, with an average value of 0.159 cm/s, suggesting that the aquifer in the study area possesses a high permeability with a good distribution of sandy gravel. The relationship between the calculated hydraulic conductivity in the aquifer and the entrance velocity into the screen, the flow rate was analyzed through the linear regression analysis. From the result of regression analysis, it showed that the hydraulic conductivity and the entrance velocity into the screen and the flow rate have a linear regression equation having about 72% of the high correlation. The result of verification in the measured data between each variable showed a high suitability from being consistent with the approximately 72% in the linear regression analysis. This study demonstrates that the groundwater flow rate can be estimated within the laterals of the radial collector well using a linear regression equation, if the hydraulic conductivity of the aquifer is known. This methodology could thus be applicable to other aquifers with hydraulic conductivity and permeability parameters similar to those in the present study area.

Analysis of runoff speed depending on the structure of stormwater pipe networks (우수관망 구조에 따른 유출 속도 분석)

  • Lee, Jinwoo;Chung, Gunhui
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.2
    • /
    • pp.121-129
    • /
    • 2018
  • Rainfall falling in the impervious area of the cities flows over the surface and into the stormwater pipe networks to be discharged from the catchment. Therefore, it is very important to determine the size of stormwater pipes based on the peak discharge to mitigate urban flood. Climate change causes the severe rainfall in the small area, then the peak rainfall can not be discharged due to the capacity of the stormwater pipes and causes the urban flood for the short time periods. To mitigate these type of flood, the large stormwater pipes have to be constructed. However, the economic factor is also very important to design the stormwater pipe networks. In this study, 4 urban catchments were selected from the frequently flooded cities. Rainfall data from Seoul and Busan weather stations were applied to calculate runoff from the catchments using SWMM model. The characteristics of the peak runoff were analyzed using linear regression model and the 95% confidence interval and the coefficient of variation was calculated. The drainage density was calculated and the runoff characteristics were analyzed. As a result, the drainage density were depended on the structure of stormwater pipe network whether the structures are dendritic or looped. As the drainage density become higher, the runoff could be predicted more accurately. it is because the possibility of flooding caused by the capacity of stormwater pipes is decreased when the drainage density is high. It would be very efficient if the structure of stormwater pipe network is considered when the network is designed.

Study on the Characteristics of Shear Strength on the Weathered Granite Soil Slope in Accordance with the Rainfall (강우에 따른 화강암질 풍화토 사면의 전단강도 특성에 관한 연구)

  • Shim Tae-Sup;Kim Sun-Hak;Ki Wan-Seo;Joo Seung-Wan
    • The Journal of Engineering Geology
    • /
    • v.14 no.4 s.41
    • /
    • pp.349-360
    • /
    • 2004
  • This study calculated the pore water pressure, the depth of seepage, the constant of the strength in accordance with the slope inclination and the rainfall intensity over the slope built by the weathered granite soil (SP, SM). And, the change of the shear strength in accordance with the rainfall has been compared and analyzed by applying the shear strength formula of the unsaturated soil. As a result, the rainfall intensity is stronger and the slope inclination is gentler the seepage speed in accordance with the rainfall became faster proportionally. As a result of comparing and analyzing both the theoretical value of Lumb and the actual value of the model, it can be said that the actual value is faster. Since SM shows the bigger shear strength than SP, it can also be said that as the granules increase, the coefficient of permeability becomes smaller; and as the seepage rate became smaller, it affects the seepage speed. Likewise, the shear strength within the slope displays the smallest shear strength at the inclination of 1:1.5 the reason of its decrease turned out that it was due to the increase of the pore water pressure.

Sea Level Rise Around Jeju Island due to Global Warming and Movement of Groundwater/seawater Interface in the Eastern Part of Jeju Island (지구온난화에 따른 제주도 근해의 해수면 상승과 제주도 동부 지역 지하수의 염수대 변화)

  • Kim, Kyung-Ho;Shin, Ji-Youn;Koh, Eun-Heui;Koh, Gi-Won;Lee, Kang-Kun
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.3
    • /
    • pp.68-79
    • /
    • 2009
  • Groundwater is the main water resource in Jeju Island because storage of surface water in reservoir is difficult in the island due to the permeable volcanic rocks. Because of this reason, the groundwater is expected to be very vulnerable to seawater intrusion by global warming, which will cause sea level rise. The long term change of mean sea level around the Korean Peninsula including Jeju Island was analyzed for this study. The sea level rise over the past 40 years was estimated to be of $2.16\;{\pm}\;1.71\;mm/yr$ around the Korean Peninsula. However, the rising trend around the eastern part of Jeju Island was more remarkable. In addition, the groundwater/seawater intrusion monitoring network operated by the Jeju Special Self-Governing Province shows that seawater intrusion becomes more prominent during dry 4-5 months in a year when the sea level increases. This implies that the fresh groundwater lens in the eastern part of Jeju Island is influenced by the sea level rise due to global warming in the long term scale.