• Title/Summary/Keyword: 투과 스펙트럼

Search Result 220, Processing Time 0.031 seconds

Estimated spectrum of a 6MV X-ray (Laplace transform 방법에 의한 x-ray의 에너지 스펙트럼 추정)

  • Yoo, Myung-Jin
    • Progress in Medical Physics
    • /
    • v.4 no.2
    • /
    • pp.37-47
    • /
    • 1993
  • The quality of radiation for a high energy x-ray beam can be specified by its attenuation curve in a selected material. The inverse Laplace transform of the attenuation curve can be used as an approximate indication of the energy spectrum of the beam. We have made a comparative investigation of the estimated spectrum obtained by the Laplace transform analysis of the transmitted exposure data measured in an absorption study of a 6MV x-ray beam. Two of existing transform pair models have been investicated and discussed.

  • PDF

Determination of the complex refractive index and thickness of MNA/PMMA thin film (MNA/PMMA 고분자박막의 복소굴절율 및 두께결정)

  • 김상열
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.357-362
    • /
    • 1996
  • The thickness and the spectrum of the complex refractive index in the region 1.5~4.5 eV, of an MNA/PMMA thin film fabricated by spin casting are determined. The film thickness and the refractive index in its transparent region is calculated by modeling the spectroscopic ellipsometry data. The extinction coefficient spectrum is obtained from the absorption spectrum in its non-transparent region. The best fit oscillator parameters of the classical Lorentz oscillator and a quantum mechanical oscillator are found. The complex refractive index spectrum by these oscillators are compared. The present technique can be applied to get the thickness and the complex refractive index of unknown polymer films and thus it will be useful in optical characterization of those films.

  • PDF

Analysis of Sound Attenuation by Chambers in Duct Systems by the Finite Element Method (유한요소법에 의한 소음기의 감음특성해석)

  • 최석주
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.23-27
    • /
    • 1991
  • 각종 홀 (음악홀, 극장, 사무실건물)의 공조 덕트계에는 미로형소음챔버가 설 치되는 경우가 많다. 이러한 소음장치를 건물내부에 설치하는 경우에는 건물 설계단계에서부터 소음챔버로 인한 감음양(투과손실 : Transmission Loss)의 예측계산이 중요하다. 그렇지만, 일반적인 소음장치는 그 형상이나 내표면의 흡음조건이 아주 복잡하기 때문에, 현단계에서는 간단한 이론만으로 투과손 실예측이 거의 불가능하다. 지금까지 이 문제에 대해서 유한요소법(Finite Element Method : FEM)을 이용해 검토한 예가 종종 소개되었으나, 대부분 소음챔버의 입구와 출구에서의 임의의 점에 대한 음압비를 투과손실로서 구 하고 있다. 그러나, 소음기자체의 실질적인 투과손실특성을 알기 위해서는 소음기의 입력 파워에 대한 출력파워의 비로서 구하지 않으면 안된다. 따라 서, 본 연구에서는 유한요소법에 의한 복소음향인텐시티(Complex sound intensity)의 수치계산법을 각종소음기 (팽창형, 미로형)의 투과손실해석에 적 용하기 위하여 이론적인 면에서 고찰했으며, 프로그램도 개발하여 모델해석 에 적용하였다. 또한, 위에서 언급된 수치해석법의 타당성의 검증을 위하여, 측정에 의한 투과손실예측방법으로서 크로스스펙트럼(Cross Spectrum)법에 의한 음향인텐시티계측법의 이용에 대해서 이론적으로 고찰했으며, 그 이론 을 기초로 한 축척 모형실험을 병행하였다.

  • PDF

Evaluation of Crack-Repairing Performance in Concrete Using Surface Waves (표면탄성파를 활용한 콘크리트 균열 보수 성능 평가 기법)

  • Ahn, Eunjong;Kim, Hyunjun;Gwon, Seongwoo;Sim, Sung-Han;Lee, Kwang Myong;Shin, Myoungsu
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.4
    • /
    • pp.496-502
    • /
    • 2017
  • The purpose of this study is to investigate the applicability of surface-wave techniques for the evaluation of the crack-repairing performance of an epoxy injection method in concrete. In this study, box-shaped concrete specimens with four different crack depths were made with identical mix proportions. The specimens with different crack depths were completely repaired using the same epoxy injection method. The spectral energy transmission ratio of surface waves is used as an index to differentiate the effects of crack depth and crack-repairing performance. The decrease of spectral energy transmission ratio in accordance with the increase of crack depth was identified before repairing. Furthermore, the spectral energy transmission ratio increased after the crack-repairing process in all specimens. The spectral energy transmission ratio is considered as a great indicator for estimating the crack-repairing performance of the epoxy injection method; the ratio was recovered up to almost 95% of the uncracked condition.

컷오프 진단법을 이용한 고속 측정법

  • Na, Byeong-Geun;Yu, Gwang-Ho;Lee, Yun-Seong;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.201-201
    • /
    • 2011
  • 컷오프 진단법은 프로브 형태로 제작된 마이크로 웨이브 진단법으로, 간단한 수식을 통해 전자밀도, 전자온도 등의 측정이 가능하며, 장치나 분석방법이 매우 간단한 장점을 지닌다. 또한, 측정에 약 1 mW 정도의 적은 파워를 사용하여 플라즈마 상태를 거의 변화시키지 않으며, 공정 플라즈마에서도 사용이 가능하다. 그러나 컷오프 진단법을 사용한 측정은 다른 종류의 프로브와 마찬가지로, 약 1초 정도의 긴 시간이 필요로 하는 단점이 있다. 따라서 기존의 컷오프 진단법은 펄스 플라즈마나 토카막과 같이 빠르게 변하는 플라즈마를 측정하기에는 무리가 있다. 본 발표에서는 컷오프 진단법을 새로운 방법으로 구현하여 더욱 빠르게 측정할 수 있는 방법을 소개하고자 한다. 컷오프 프로브는 방사 안테나, 측정 안테나와 네트워크 분석기로 구성되어 있다. 네트워크 분석기는 두 안테나 사이의 플라즈마 투과 스펙트럼을 만드는데 쓰이며, 주파수 스캔 방법을 사용하여 스펙트럼을 만든다. 컷오프 진단법의 측정시간은 주파수 스캔에 걸리는 시간에 의해 결정된다. 본 발표에서는 측정을 빠르게 하고자 전혀 새로운 방법을 도입하였다. 펄스 형태의 단일신호를 플라즈마 투과 특성을 살피는데 이용하면 측정을 매우 빠르게 할 수 있다. 그래서 펄스제조기와 오실로스코프를 이용하여 스펙트럼을 얻는데 사용하였다. 이론적으로는 이 방법을 통해 측정시간을 수 nano second 수준으로 줄일 수 있다. 실험적으로는 micro second 정도의 시간으로 측정을 할 수가 있었으며, 동일한 스펙트럼 및 측정결과를 얻을 수 있었다. 또한 이 방법을 펄스플라즈마에 적용할 경우 수십 nano second 수준의 시간분해능으로 측정을 할 수가 있었다. 이 방법을 응용하면 토카막 언저리와 같이 매우 빠르게 변하며 반복되지 않는 플라즈마의 측정도 가능할 것으로 예상된다.

  • PDF

Spectral Energy Transmission Method for Crack Depth Estimation in Concrete Structures (콘크리트 구조물의 균열 깊이 추정을 위한 스펙트럼 에너지 기법)

  • Shin, Sung-Woo;Min, Ji-Young;Yun, Chung-Bang;Popovics, John S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.2
    • /
    • pp.164-172
    • /
    • 2007
  • Surface cracks in concrete are common defects that can cause significant deterioration and failure of concrete structures. Therefore, the early detection, assessment, and repair of the cracks in concrete are very important for the structural health. Among studies for crack depth assessment, self-calibrating surface wave transmission method seems to be a promising nondestructive technique, though it is still difficult in determination of the crack depth due to the variation of the experimentally obtained transmission functions. In this paper, the spectral energy transmission method is proposed for the crack depth estimation in concrete structures. To verify this method, an experimental study was carried out on a concrete slab with various surface-opening crack depths. Finally, effectiveness of the proposed method is validated by comparing the conventional time-of-flight and cutting frequency based methods. The results show an excellent potential as a practical and reliable in-situ nondestructive method for the crack depth estimation in concrete structures.

The Optical Properties of SiO2/TiO2/ZrO2 Broadband Anti-reflective Multi-layer Thin Films Prepared by RF-Magnetron Sputtering (SiO2/TiO2/ZrO2 광대역 반사방지막의 제작 및 광학적 특성 분석)

  • Kang, M.I.;Ryu, J.W.;Kim, K.W.;Kim, C.H.;Baek, Y.K.;Lee, D.H.;Lee, S.R.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.2
    • /
    • pp.138-147
    • /
    • 2008
  • $SiO_2/TiO_2/ZrO_2$ broadband anti-reflective multi-layer thin films were prepared at room temperature by RF sputtering system. Optical constants and structural properties on each layer of films were analyzed by spectroscopic ellipsometer and transmittance spectra of the films were measured by $UV-V_{is}$ spectrophotometer in the range of 300$\sim$900 nm. To evaluate the films, we compared the measured and analyzed spectra with designed spectra. We investigated influence of discrepancy of thickness and refractive indices of each layer on changes of the transmittance spectra. It was found that refractive indices and shape of dispersion of deposition materials are more contributed to changes of the transmittance spectra than thickness of layer.

Compare the Clinical Tissue Dose Distributions to the Derived from the Energy Spectrum of 15 MV X Rays Linear Accelerator by Using the Transmitted Dose of Lead Filter (연(鉛)필터의 투과선량을 이용한 15 MV X선의 에너지스펙트럼 결정과 조직선량 비교)

  • Choi, Tae-Jin;Kim, Jin-Hee;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.80-88
    • /
    • 2008
  • Recent radiotherapy dose planning system (RTPS) generally adapted the kernel beam using the convolution method for computation of tissue dose. To get a depth and profile dose in a given depth concerened a given photon beam, the energy spectrum was reconstructed from the attenuation dose of transmission of filter through iterative numerical analysis. The experiments were performed with 15 MV X rays (Oncor, Siemens) and ionization chamber (0.125 cc, PTW) for measurements of filter transmitted dose. The energy spectrum of 15MV X-rays was determined from attenuated dose of lead filter transmission from 0.51 cm to 8.04 cm with energy interval 0.25 MeV. In the results, the peak flux revealed at 3.75 MeV and mean energy of 15 MV X rays was 4.639 MeV in this experiments. The results of transmitted dose of lead filter showed within 0.6% in average but maximum 2.5% discrepancy in a 5 cm thickness of lead filter. Since the tissue dose is highly depend on the its energy, the lateral dose are delivered from the lateral spread of energy fluence through flattening filter shape as tangent 0.075 and 0.125 which showed 4.211 MeV and 3.906 MeV. In this experiments, analyzed the energy spectrum has applied to obtain the percent depth dose of RTPS (XiO, Version 4.3.1, CMS). The generated percent depth dose from $6{\times}6cm^2$ of field to $30{\times}30cm^2$ showed very close to that of experimental measurement within 1 % discrepancy in average. The computed dose profile were within 1% discrepancy to measurement in field size $10{\times}10cm$, however, the large field sizes were obtained within 2% uncertainty. The resulting algorithm produced x-ray spectrum that match both quality and quantity with small discrepancy in this experiments.

  • PDF

Preparation of Ultra-Thin Polyimide Film by Using Langmuir-Blodgett(LB) Method (Langmuir-Blodgett(LB)법을 이용한 폴리이미드 초박막의 제작)

  • Kim, Yong-Kwan
    • Journal of the Korean Applied Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.151-155
    • /
    • 1994
  • Polyamic acid alkylamine (N, N-dimethylhexadecylamine)(PAAS)염을 합성하여 그 합성여부를 확인하였으며 PAAS염의 Langmuir막의 ${\pi}-A$ 등온선 및 표면 전위 특성 등을 조사 하였다. Langmuir-Blodgett법에 의하여 PAAS염의 LB막을 여러종류의 기관에 누적하였으며 누적여부를 자외선 흡수 스펙트럼 및 적외선 투과 스펙트럼을 이용하여 조사하였다. 그리고 PAAS LB막을 열처리에 의하여 이미드(imide)화시켜 폴리이미드 LB막을 제조하였으며 그 이미드화 여부를 자외선 및 적외선 스펙트럼을 이용하여 조사하였다.