• Title/Summary/Keyword: 투과 스펙트럼

Search Result 220, Processing Time 0.027 seconds

Empirical Determination of a CT X-ray Spectra by Numerical Analysis using Transmission Data (투과선량의 수치해석에 의한 전산화단층영상장치 X선의 에너지 분포결정)

  • 최태진;김옥배;서수지
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.35-43
    • /
    • 1997
  • The knowledge of x-ray spectra is highly desirable in some investigation involves the differential penetrating power and absorption coefficient correction of various photon beam. The transmission data were obtained from the 80 kVp and 120 kVp of CT x-ray beam with the aluminium filter which is designed in a 30 cm of diameter and pipe-typed filter was prepared from 5.0 mm upto 92.3 mm of thickness. To obtain the reconstructed spectra of CT x-ray, the investigator used the iterative numerical analysis which has been extended to include the tungsten characteristics from experimental transmission data with energy interval of 2 keV. Comparison of the calculated transmission data from the reconstructed spectra with that of measurement shows good agreement in both 80 kVp and 120 kVp x-ray beams. This numerical analysis based on iteratively calculation of fractional exposure per energy interval shows the high potential of usefulness of determination the x-ray spectra from the attenuated beam in diagnostic energy range.

  • PDF

Scattering Wave Spectrum by a Pile Breakwater in Directional Irregular Waves (다방향 불규칙 파랑중 파일 방파제에 의한 산란파 스펙트럼)

  • Cho, Il-Hyoung
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.6
    • /
    • pp.586-595
    • /
    • 2007
  • The analytic solution of wave scattering of monochromatic waves on a pile breakwater by an eigenfunction expansion method is extended to the case of directional irregular waves. The scattering wave spectrum and the force spectrum can be expressed from the reflection coefficient, transmission coefficient and the wave forces obtained from changing frequencies and incident angles in monochromatic waves. By numerical integration of 2-dimensional spectrum which is function of frequencies and incident angles, the representative values for the scattered waves and wave forces are obtained and the dependence of the transmission coefficients and wave forces on the directional distribution function, the principal wave direction, the submergence depth, and porosity is analyzed.

Optical properties of ink color filters (잉크 색상 필터의 광학적 특성)

  • Lee, Chan-Ku;Lee, Su-Dae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.23-28
    • /
    • 2003
  • We report a switchable RGB color filters for Lab on a chip. Ink color filter devices are fabricated by PDMS patterning process. The optical transmission in the ultra-violet and visible wavelengths of color filters have been investigated. The ink color filters are characterised by the slope and shape of the spectrum. The transmission of red/yellow filter consists of curves with a sharp cut-off spectrum at 600 and 500 nm. The blue output of the ink filter has 80% peak transmission and weak red-leak, while the green ink filter has 48% peak transmission and red-leak.

  • PDF

Alignment of a ring laser cavity by using the cavity transmission spectrum control method (투과광 스펙트럼 측정법을 이용한 링레이저 공진기의 광학적 정렬)

  • 전형욱;최용진;이기홍;신상훈;이혁수;손정영
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.6
    • /
    • pp.456-460
    • /
    • 1997
  • Several methods of aligning ring type cavities have been investigated for long time. The measurement of cavity transmission spectrum control is somewhat effective due to aligning cavity with measuring cavity loss at the same time. In this research, four mirrors are aligned and attached by the measurement of pulse width of the transmitted light. The intracavity loss is optimized to about 0.98%, giving the calculated total reflection coefficient of about 99.02%.

  • PDF

A Study of the Wave Control Characteristics of the Permeable Submerged Breakwater using VOF Method in Irregular Wave Fields (불규칙파동장에 있어서 VOF법에 의한 투과성잠제의 파랑제어 특성에 관한 연구)

  • Kim Do Sam;Lee Kwang Ho;Yoo Hyun Sang;Kim Chang Hoon;Son Byoung Kyu
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.16 no.3
    • /
    • pp.121-129
    • /
    • 2004
  • The different types of coastal souctures have been constructed for the protection of coastal region from the incident waves. Among them. the permeable submerged breakwater has been widely used as a wave dissipater and sediment transport controller because of its excellent advantages in scenery effects, construction efficiency and environment aspects. This study numerically investigated the characteristics of wave energy variations and transmission coefficient at the rear of the permeable submerged breakwater installed in the irregular wave field. To analyze it's performance numerically, a two-dimensional numerical wave flume based on VOF method was used. A frequency spectral analysis showed that the spectral peak moved to the short-period in the one-row submerged breakwater, and the wave energy was distributed evenly for the whole period in the two-row submerged breakwater in the case of breaking on the submerged breakwater. The spectral peak was shown to be converged within the significant wave period at the rear of the permeable submerged breakwater in the case of non-breaking conditions. From the result of transmission coefficients analysis. it was confirmed that a considerable quantity of wave energy was transmitted to the rear of the permeable submerged breakwater in the case of non-breaking rather than breaking.

Analysis of the Propagation Characteristics of Two Dimensional Ultrasonic Fields in Layered Media (층상매질에서의 이차원 초음파음장 전파특성해석)

  • 윤혁준
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06c
    • /
    • pp.445-448
    • /
    • 1998
  • 고유음향 임피던스가 다른 물질이 층상구조를 이루고 있는 매질내에서 임의의 한 층에 형성된 이차원 초음파 음장이 다른 매질로 전파될 때에의 특성을 각스펙트럼법에 의해 해석하였다. 음원으로서는 baffle된 원형 트랜스듀서를, 층상구조를 매질로서는 물과 생체조직(지방)의 경계를 각각 고려하였다. 해석에 있어서는 먼저 각스펙트럼 분해요소, 즉, 음원의 크기 및 거리에 의존하는 기준음장의 최적 크기와 샘플링 간격을 균질매질을 이용하여 결정한 다음, 그 요소를 층상매질에 적용하였다. 그 결과, 경계면에서의 입사각(공간주파수)의 의존하는 투과계수에 입사음장의 곱으로 나타내어지는 투과음장은 각스펙트럼법에 의해 짧은 시간내에 정도 높게 산출될 수 있음을 보인다.

  • PDF

Comparison of Sensing Ability of Extraordinary Optical Transmission Sensor for Diverse Configurations of Substrate Hole Array (다양한 홀 어레이 기판에서 측정한 특이 광 투과 센서의 센싱 성능 비교)

  • Lee, Yeji;Song, Hyerin;Ahn, Heesang;Kim, Kyujung
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.2
    • /
    • pp.67-73
    • /
    • 2019
  • In this paper, we investigated the sensing ability of an extraordinary optical transmission sensor, which is based on the diverse configurations of highly ordered structures. The diverse nanostructures of subwavelength hole array were designed to have different periods and lattice configurations of the array. To verify the sensing ability of the sensor, we measured the transmittance spectra of samples (n = 1.333, 1.363) for diverse configurations of substrates. The measured transmittance spectra of diverse materials with different refractive indices show that the sensitivity increased as the period of the structures increased. Also, improved sensing performance of the sensor was achieved for the square array, compared to the hexagonal array.

Time Resolution of Fourier Cutoff Probe for Electron Density Measurement

  • Na, Byeong-Geun;Yu, Gwang-Ho;Kim, Dae-Ung;Yu, Dae-Ho;Yu, Sin-Jae;Kim, Jeong-Hyeong;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.273-273
    • /
    • 2012
  • 컷오프 진단법은 두 개의 탐침 형태로 제작된 마이크로 웨이브 진단법으로, 간단한 수식을 통해 전자밀도, 전자온도 등을 측정할 수 있다. 컷오프 탐침은 방사 안테나, 측정 안테나와 네트워크 분석기로 구성되어 있다. 네트워크 분석기는 두 안테나 사이의 플라즈마 투과 스펙트럼을 만드는데 쓰이며, 스펙트럼 분석을 통해 플라즈마 변수들을 측정할 수 있다. 이 진단법은 장치나 분석방법이 매우 간단한 장점을 지니며, 약 1 mW 정도의 적은 파워를 사용하여 플라즈마 상태를 거의 변화시키지 않는 측정이 가능하다. 또한 CF4와 같은 공정 가스를 이용한 플라즈마에서도 사용이 가능하다. 그러나 컷오프 진단법을 사용한 측정은 다른 종류의 진단법과 마찬가지로, 약 1초 정도의 긴 시간을 필요로 하는 단점이 있어, 펄스 플라즈마나 토카막과 같이 빠르게 변하는 플라즈마를 측정하기에는 무리가 있다. 최근에 개발된 푸리에 컷오프 탐침(Fourier Cutoff Probe, FCP)는 기존의 컷오프 탐침의 느린 시간분해능을 개선하기 위해 개발되었다. [1] 펄스 형태의 단일신호를 플라즈마를 투과하기 전후로 비교하면 투과 스펙트럼 및 플라즈마 변수들을 얻을 수 있으며, 기존 연구에서 구한 시간 분해능은 약 15 나노초였다. 이 값은 펄스 발생장치의 스펙에 따라 변하게 된다. 펄스폭이 짧을수록 시간분해능이 좋아지지만, 무한정 좋아질 수는 없다. 이 논문에서는 FCP 측정의 시간 분해능을 이론적으로 구하고, 시간 분해능의 이론적 한계를 구했다.

  • PDF

The Characteristics of Wave Energy Variations by Impermeable Submerged Breakwater Using VOF Method in Irregular Wave Fields (VOF 법에 의한 불규칙파동장에 있어서 불투과잠제에 의한 파랑에너지 변형특성)

  • 허동수;김도삼
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.15 no.4
    • /
    • pp.207-213
    • /
    • 2003
  • This study is to numerically investigate the characteristics of wave energy variations propagating over impermeable submerged breakwaters with irregular waves. Two-dimensional numerical wave flume based on the VOF method was used. VOF method is the most efficient capable of simulating free surfaces including wave breaking. From the computed frequency spectrum results, wave breaking play important role in ability of the submerged breakwaters to dissipate incident wave energy. In case of occurring wave breaking, our analysis shows that wave energy moves to short wave period on one-row impermeable submerged breakwater's lee side and is widely distributed not having peak period on two- row impermeable submerged breakwater's lee side.

Determination of optical constants for cholesteric liquid crystal films by using transmittance and reflectance spectra (투과 및 반사 스펙트럼을 이용한 콜레스테릭 액정 필름의 광학 상수 결정)

  • 박종락;류기한
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.1
    • /
    • pp.63-67
    • /
    • 2004
  • We have obtained optical constants for cholesteric liquid crystal (CLC) films by fitting theoretical spectra of transmittance and reflectance with measured ones. Berreman's 4${\times}$4 matrix approach was used for the calculation of theoretical spectra. The fitting method was applied to three samples with different reflection bands and fitted results of refractive indices for CLC samples were compared with measured ones for a parallel-aligned LC sample. It was found that the two results were in fairly good agreement within the error of the fitted results for the three CLC samples.