• Title/Summary/Keyword: 투과 소음

Search Result 259, Processing Time 0.029 seconds

Experimental Study on Acoustic Characteristics of Perforated Tube and Perforated Tube Muffler (다공관 및 다공형 소음기의 음향학적 특성에 대한 실험적 연구)

  • Yoon, Doo-Byung;Kim, Yang-Hann
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.62-72
    • /
    • 1995
  • The acoustic characteristics of perforated tube muffler are studied in terms of non-dimensional wavenumber ka and admittance-ratio AZ. This study includes not only the case of perforated tubes having uniform hole distribution along the length but also the case of having non-uniform hole distributions. The acoustic hole impedance and transmission loss of perforated tube of which has various hole distributions were measured. The experimental results demonstrated that the transmission loss of perforated tube is a function of non-dimensional wave number ka and admittance-ratio AZ. The transmission loss of perforated tube muffler is predicted by the numerical method which is based on Sullivans and compared with the experimental ones.

  • PDF

Level Set Based Topological Shape Optimization of Phononic Crystals (음향결정 구조의 레벨셋 기반 위상 및 형상 최적설계)

  • Kim, Min-Geun;Cho, Seon-Ho;Hashimoto, Hiroshi;Abe, Kazuhisa
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.693-696
    • /
    • 2011
  • 본 논문에서는 레벨셋 방법을 이용하여, 소음을 차단하기 위한 음향 구조물의 형상 최적 설계를 수행하였다. 음향 결정 구조에서는 음향이 흩어져 있는 결정 구조에 의해서 굴절되기 때문에 결정 모양을 조정함으로써, 음향 거동을 제어 할 수 있다. 형상 최적 설계의 목적은 특정한 각도와 각속도로 입사되는 입사파에 대해서 음향 투과율(acoustic transmittance)이 최소가 되도록 음향 결정의 형상(inclusion shape)을 결정하는 것이다. 음향 압력(acoustic pressure)은 주기성을 갖는 음향 결정에 대해서 헬몰츠(Helmoltz)형태의 지배 방정식을 풀어서 얻을 수 있다. 본 연구에서는 음향 구조물로 결정이 수평 방향으로는 주기적으로 무한히 분포하고 수직방향으로는 유한한 층간 구조를 가지고 있는 소음 방어벽 (Noise barrier)을 고려한다. 결정의 위치는 고정되어 있고, 결정의 형상을 설계 변수로서 음파의 거동을 제어할 수 있도록 하였다. 주기적 구조물을 고려하기 때문에 결정의 좌와 우에 Bloch 이론을 적용해 주기적 경계조건을 부과하였고, 소음 방어벽 위와 아래에는 임피던스 행렬(impedance matrix)를 이용하여, 무한 균질 영역과 소음 방어벽사이의 음파 투과를 모사하였다. 복잡한 형상 변화를 표현하기 위해 임시적 경계를 이용한 레벨셋 방법을 사용하였다. 설계 민감도 해석을 통해 목적함수가 감소하는 방향으로 경계에서의 수직 벡터를 계산하고, 이를 헤밀턴-자코비(Hamilton-Jacob) 방정식에 대입하여, 최적의 형상을 나타내는 레벨셋 함수를 구하였다.

  • PDF

Transmission Loss Prediction of KHST's Wall Section (KHST 차량 벽면의 투과손실값 예측)

  • Kim, Kwan-Ju;Yoon, Tae-Jung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.104-109
    • /
    • 2002
  • The purpose of this study is to calculate transmission loss of KHST passenger vehicle's wall section accurately Typical transmission loss measurement of wall in the laboratory condition was carried out in advance, which is easier than KHST. Transmission loss results were compared with those by statistical acoustic method. Transmission loss values of KHST calculated by experimental method are compared with those from closed form solution.

  • PDF

Transmission Loss Prediction of KHST′s Wall (KHST 차량 벽면의 투과손실값 예측)

  • Kim, Kwanju;Taejung Yoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.317.2-317
    • /
    • 2002
  • Transmission loss of KHST passenger vehicle was calculated using measured acoustic data: In order to verify the transmission loss results for KHST case, similar experiment was carried out in laboratory condition, which result was compared those by geometric acoustic method. The computational results shows good agreement with the transmission loss magnitude from experiments. This paper also mentions items to obtain more accurate transmission loss values, i. e. how to assure reverberant field condition, the selection of source speaker' location.

  • PDF

A Study to Estimate Transmission Loss of HST using a Small Scale Reverberation Chamber (소형잔향실을 이용한 고속철도 차량 구조재의 투과손실 연구)

  • Kim, Tae-Min;Kim, Jeung-Tae
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.1
    • /
    • pp.19-23
    • /
    • 2011
  • The method to reduce interior noise of train was being studied. To improve transmission loss of train is one of the best way to reduce interior noise. But, the estimate to transmission loss requires lots of the commercial costs. In this study, the method to estimate transmission loss of high speed train is proposed using a scale reverberation chamber. The result shows that a transmission loss estimated using small scale reverberation is similar to that using huge reverberation chamber. The transmission loss estimated based on small scale reverberation chamber can be optimal with respect to the commercial coasts.

Numerical investigation on cavitation and non-cavitation flow noise on pumpjet propulsion (펌프젯 추진기의 공동 비공동 유동소음에 대한 수치적 연구)

  • Garam Ku;Cheolung Cheong;Hanshin Seol;Hongseok Jeong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.3
    • /
    • pp.250-261
    • /
    • 2023
  • In this study, the noise contributions by the duct, stator and rotor, which are the propulsor components, are evaluated to identify the flow noise source in cavitation and non-cavitation conditions on pumpjet propulsion and the noise levels in both conditions are compared. The unsteady incompressible Reynolds averaged Navier-Stokes (RANS) equation based on the homogeneous mixture assumption is applied on the suboff submarine hull and pumpjet propeller in the cavitation tunnel, and the Volume of Fluid (VOF) method and Schnerr-Sauer cavitation model are used to describe the two-phase flow. Based on the flow simulation results, the acoustic analogy formulated by Ffowcs Williams and Hawkings (FW-H) equation is applied to predict the underwater radiated noise. The noise contributions are evaluated by using the three types of impermeable integral surface on the duct, stator and rotor, and the two types of permeable integral surface surrounding the propulsor. As a result of noise prediction, the contribution by the stator is insignificant, but it affects the generation of flow noise source due to flow separation in the duct and rotor, and the noise is predominantly radiated into the upward and right where the flow separations are. Also, the noise is radiated into the thrust direction due to pressure fluctuation between suction and pressure sides on the rotor blades, and the it can be seen that the cavitation effect into the noise can be considered through the permeable integral surface.

승용차의 실내소음 패널기여도 분석에 대하여

  • 이두호;황우석
    • Journal of KSNVE
    • /
    • v.11 no.2
    • /
    • pp.187-195
    • /
    • 2001
  • 승용차 실내소음은 소음의 전달 방법에 따라 구조기인소음(structure-borne noise)과 공기기인소음(air-borne noise)으로 구별된다. 구조기인 소음은 차체에 전달된 외력이 차체를 통하여 전달되고 전달된 차체의 진통이 최종적으로 차실을 이루는 패널의 진동을 일으켜 승객에 전달되는 소음이며 공기기인소음은 발생한 소읍이 공기를 타고 전파되어 차실을 투과하여 승객의 귀에 전달되는 소음을 말한다. 구조기인소음을 일으키는 기진력으로 엔진의 관성 및 폭발력, 노면의 입력, 구동계 진동, 풍력 등이 있다. 발생된 기진력은 엔진 마운트, 서스펜션 등을 통하여 차체에 전달되고 최종적으로 대쉬, 루프 등의 패널을 떨게 만들며 이러한 진동은 50∼500Hz 대역에서 차실 공간의 음향 특성에 따라 가감되어 저주파 실내 소음을 발생시킨다. 500Hz 이상 대역의 실내소음은 일반적으로 공기기인 소음이 대부분을 차치하게 된다.(중략)

  • PDF

An Analysis of the Sound Propagation between Rooms with Different Mediums (서로 다른 매질을 갖는 격실사이의 음파전달해석)

  • Kim, Hyun-Sil;Kim, Jae-Seung;Lee, Seong-Hyun;Seo, Yun-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.5
    • /
    • pp.402-407
    • /
    • 2013
  • In this paper, an analysis of sound propagation between two rooms with different mediums is discussed. Statistical energy analysis (SEA) is used to consider energy equilibrium among subsystems associated with the sound pressure levels in two rooms and the vibration level of the wall between rooms. Effect of the sound radiation from the structure-borne noise of the wall on sound pressure level of the receiving room is investigated. For a numerical example, sound propagation between engine room and water tank joined by a steel plate whose size is $8.4{\times}4$ m, is considered. It is found that when the critical frequency of the plate is above the frequency range of interest, the sound pressure level in the water tank is dominated by sound transmission through the plate, while sound radiation from the structure-borne noise of the plate is negligible except low frequency range below 63 Hz.