• Title/Summary/Keyword: 통풍저항

Search Result 16, Processing Time 0.024 seconds

Prediction of the Occurring Time of Stall for a Booster Fan in a Power Plant Combusting Low Quality Coal through Draft Loss (저품위탄 연소시 탈황용 승압송풍기 실속시점 예측)

  • Kim, Yeong-Gyun;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.8 no.4
    • /
    • pp.34-39
    • /
    • 2012
  • This study presents how low quality coal combustion affects the desulfurizer draft system by correlating of draft loss in a coal-fired thermal power plant and predicts the stall occurrence time of a booster fan. In case of low quality coal, a lot of coal is needed to generate equivalent output power, thereby the rating of increasing draft loss was faster than designed amount of coal. We surely confirmed that draft loss affects the specific energy of a booster fan strongly. On this basis, it is possible to predict the occurring time of stall for a booster fan from current operation specific energy to stall limit specific energy. This study suggests increasing speed of draft loss in each caloric value and the impact of specific energy at a booster fan, it expects to help safe operating in a thermal power plant.

  • PDF

A Study on Operation Mode Development for Construction of Flue Gas Desulfurization System in Thermal Power Plants (화력발전소 탈황설비 설치를위한 운전모드 개발에 관한 연구)

  • 문채주;장영학;김의선
    • Journal of Energy Engineering
    • /
    • v.9 no.1
    • /
    • pp.10-18
    • /
    • 2000
  • 기존 화력발전소에 탈황설비가 추가되고, 이로 인하여 새로운 계통의 통풍저항을 상쇄시키기위하여 기존의 유인통풍기와 탈황설비 사이에 승압통풍기가 설치되고 있다 통풍저항의 증가와 새로운 통풍기의 추가는 기존 통풍특성의 변화를 나타낼것이고 , 빈번한 발저소 정지를 가져오는 심한 노내 압력변동을 보이게 될 것이다. 따라서 , 발전소를 안전하게 운전하기 위해서는 설계된 통풍계통을 기반으로 한 교정된 운전모드에 관한 지식이 요구된다. 본 논문에서는 MMS (Modular Modeling System) 소프트웨어를 사용하여 우회 댐퍼의 개방을 수반하는 유인 및 승압통풍기의 비상정지의 사례에 따른 화력발전소 노내 압력, 통풍기의 압력과 유량, 댐퍼의 개도등과 같은 해석결과를 제시하고 논의하고 있다.

  • PDF

PRESSURE DROP, RESPIRATION MODELS AND AUTOMATIC AERATION OF ROUGH RICE (벼의 압력손실 및 호흡 모델과 자동통풍에 관한 연구)

  • Chung, J.H.;Verma, Lalit R.
    • Journal of Biosystems Engineering
    • /
    • v.16 no.3
    • /
    • pp.298-311
    • /
    • 1991
  • 빈 시스템에서 적정 팬을 선정하기 위해서, 빈에서 벼를 건조 혹은 통풍시킬 때 벼의 저항에 의해 발생되는 공기의 압력손실을 예측하는 모델을 개발하였다. 또한 벼의 건물 손실을 예측하기 위하여 벼의 호흡 모델을 개발하였다. 그리고 온도 및 습도 센서들을 이용한 자동계측 시스템을 사용하여 저장된 벼의 상태를 연속적으로 측정, 분석함으로써 벼의 통풍기준을 결정하고 이를 근거로 빈의 자동통풍 시스템을 개발하여 평가하였다. 공기의 정압 손실은 공기의 속도 및 벼의 함수율의 함수로서 나타내어졌으며, 일정 곡물 깊이에서 벼의 함수율이 낮을수록 그 정압손실은 증가하였다. 벼의 호흡에 의해 발생되는 이산화탄소의 양은 저장온도, 벼의 함수율, 저장 기간의 함수로서 나타낼 수 있었다. 벼의 안전 저장을 위해 곡물의 온도 및 함수율, 평형상대습도, 벼의 품질저하지수(deterioration index)에 대한 자동통풍 기준을 결정하였으며 이들을 이용해서 퍼스널 컴퓨터로 팬, 제습기 등의 통풍 장치들을 자동제어하는 자동통풍 시스템을 개발하였다. 이 시스템은 곡물의 상태를 예측, 제어함으로써 14% 이하의 함수율과 4이하의 품질저하지수, 그리고 어떤 균류도 생성시키지 않음으로써 벼를 안전하게 저장할 수 있었다.

  • PDF

공조기용 열교환기

  • 윤정인
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.29 no.10
    • /
    • pp.47-51
    • /
    • 2000
  • 최근 룸에어콘이나 패키지에어콘의 에너지 절약, 쾌척성 등에 대환 사용자나 회사로부터의 요구는 더더욱 높아지고 있다. 공조기의 중요한 구성요소 중 하나인 열교환기도 이러한 요구에 대응하여 기술개발이 계속해서 진행되고 있다. 공조용 열교환기를 설계할 때 가장 중요한 과체는 비용이냐 설치성 등의 제약조건올 만족하면서 필요한 교환열량을 달성하기 위해, 요구되는 열 전달계수(K)와 전열면적(A)의 곱인 KA값을 얼마나 확보하는가 하는 점에 있다. 그러나 이 외의 과제, 예를 들어 홴입력, 소음을 억제하기 위한 공기측 통풍저항의 감소, 증발온도에 영향을 마치는 관내압력손실의 감소 등도 중요한 과제이다. KA값 증대와 통풍저항억제를 동시에 판촉하기 위해 공조용 열교환기는 전면면적을 크게 하고 두께를 작게 하여 사용하는 것이 원칙이다. 또, 전열관의 관경도 관 둘레길이와 냉매분배성능 면에서 제약이 발생한다. 이와 같은 배경으로부터 공조용 열교환기는 판경 6~10 mm정도의 전열 관을 20~25mm길이로 배치한 핀튜브형 열교환기가 주류로 되어있다. 여기에서는 공조기에 널리 사용하고 있는 핀튜브형 열교환기에 대한 최근의 기술개발 사례를 소개하고자 한다.

  • PDF

차량 에어컨용 친수-항균 표면처리 기술

  • 오승택
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.29 no.10
    • /
    • pp.28-34
    • /
    • 2000
  • 차량용 에어컨의 증발기 표면에 공기가 지나갈 때 결로로 인한 통풍저항 증대와 비산 현상을 억제하며 세균번식과 냄새가 발생하는 증발기에 항균성과 탈취효과를 주기 위해, 친수-항균재가 세계적으로 1980년대부터 적용되어 왔다. 본 고에서는 친수-항균재의 기술개발 동향과 평가기술을 소개하고자 한다.

  • PDF

A Study on the Entrance Region Fouling of Sludge Incinerator Air-preheater at IronWorks (제철슬러지 소각로의 공기예열기 입구의 파울링특성 연구)

  • 박상일;김정근
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2003.05a
    • /
    • pp.557-562
    • /
    • 2003
  • 산업체 소각로의 고온 배가스에는 소각물질의 특성에 따라 다양한 성분의 오염물질이 함유되어 있다. 고온 소각배가스의 후처리를 위하여 배가스냉각용 열교환기가 사용되고 있다. 그러나, 소각로 열교환기의 입구와 전열면에 파울링 현상이 발생하여 열교환기의 전열성능이 감소하고 또한 심한 경우, 유로면적이 줄어들어 통풍저항이 증대된다.(중략)

  • PDF

당뇨병과 비만

  • 김성래
    • The Monthly Diabetes
    • /
    • s.148
    • /
    • pp.16-17
    • /
    • 2002
  • 비만과 관련된 질환은 당뇨병, 고혈압, 고지혈증, 죽상경화증(동맥경화증), 심근경색증, 지방간, 담석증, 골 관절염, 통풍, 폐쇄성 수면 무호흡증, 대장암, 직장암, 전립선암, 유방암, 자궁내막암 등의 각종 암, 불안, 우울, 적응장애, 히스테리 등의 심리적 질환 등이 있다. 비만이 있을 때 우리 몸에서는 인슐린 자체에 대한 저항성이 생겨서 말초조직에서의 포도당 이용이 감소된다. 연구에 의하면 표준체중의 45$\%$ 이상을 초과한 비만환자는 당뇨병 발생의 위험도가 30배 증가된다고 알려져 있다. 비만이 있을 때 흔히 동반되는 질환들 중 특히 고혈압, 고지혈증, 죽상경화증 등의 질환은 당뇨가 있을 때 흔히 동반될 수 있는 질환들이고, 인슐린 저항성과 깊은 관계가 있는 질환들로 당뇨인들에게 비만은 매우 중요한 질환이라고 할 수 있겠다.

  • PDF

A Study for Aerodynamic Drag Reduction on Variable Message Sign using Flow Analysis (유동해석 기반 도로전광표지 공기저항 저감 구조 연구)

  • Lim, Se-Mi;Song, Dae-Young;Park, Kyeung-U;Park, Jun-Seok
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.6
    • /
    • pp.140-146
    • /
    • 2011
  • As the demand of Variable Message Sign(VMS) has become pervasive in fulfilling the ITS policy, the costs of maintaining the Variable Message Sign operation have also increased. This paper proposes the U-curved figure, the C-curved figure and the ventilated figure type for aerodynamic drag reduction on Variable Message Sign and shows the analysis of aerodynamic drag effects using Flow Analysis. As a results of the flow analysis for right-angled, 45 degrees from side to side and 45 degrees from up or down, the C-curved figure and the ventilated figure type show about 30% aerodynamic drag reduction in all direction. And the U-curved figure type shows vivid aerodynamic drag reduction for right-angled and 45 degree from side to side, but trivial aerodynamic drag reduction for 45 degree from up or down. It is possible to reduce not only the damage on Variable Message Sign due to typhoon because of the aerodynamic drag reduction, but also installation constraints because of lighter Variable Message Sign support structure by appling the proposed structure and analysis in this paper.

Study of Pressure Cooling of Agricultural Products Using a Pallet Bin (팔레트 빈(pallet bin)을 이용한 농산물의 차압통풍 냉각 연구)

  • Jeong, Hoon;Yun, Hong-Sun;Lee, Hyun-Dong;Kim, Young-Keun;Lee, Won-Ok
    • Food Science and Preservation
    • /
    • v.15 no.6
    • /
    • pp.847-851
    • /
    • 2008
  • The handling and processing of agricultural products in Korea is done manually. Small plastic boxes, nets, and corrugated cardboard boxes are used as containers during harvesting, sorting and other product handling operations. However, these practices are labor-intensive, time-consuming, require various kinds of packing materials, and are expensive because of high operating costs. To overcome these problems, the use of pallet bins with pre-cooling and storage features for handling and processing bulk farm products was investigated. The airflow resistances through bulk potato, onion and mandarin stocks were measured, and the pallet bins and a pressure pre-cooling device were manufactured. The opening ratio, bed depth and airflow rate through bulk potato, onion and mandarin in the pallet bin were defined with regression equations. The cooling rates of bulk potato, onion and mandarin were 0.8C/h ($21.7{\rightarrow}0C$, 14.5 h), 0.4C/h ($15.4{\rightarrow}.0C$, 32.2 h) and 0.7C/h ($13.7{\rightarrow}C$, 18.8 h), respectively, with the pressure pre-cooling system. Temperature deviances for storage of bulk potato, onion and mandarin were 0.12C, 0.12C and 0.17C, respectively.

The Influence of Ventilation and Shade on the Mean Radiant Temperature of Summer Outdoor (통풍과 차양이 하절기 옥외공간의 평균복사온도에 미치는 영향)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.100-108
    • /
    • 2012
  • The purpose of the study was to evaluate the influence of shading and ventilation on Mean Radiant Temperature(MRT) of the outdoor space at a summer outdoor. The Wind Speed(WS), Air Temperature(AT) and Globe Temperature(GT) were recorded every minute from $1^{st}$ of May to the $30^{th}$ of September 2011 at a height of 1.2m above in four experimental plots with different shading and ventilating conditions, with a measuring system consisting of a vane type anemometer(Barini Design's BDTH), Resistance Temperature Detector(RTD, Pt-100), standard black globe(${\O}$ 150mm) and data acquisition systems(National Instrument's Labview and Compfile Techs' Moacon). To implement four different ventilating and shading conditions, three hexahedral steel frames, and one natural plot were established in the open grass field. Two of the steel frames had a dimension of $3m(W){\times}3m(L){\times}1.5m(H)$ and every vertical side covered with transparent polyethylene film to prevent lateral ventilation(Ventilation Blocking Plot: VP), and an additional shading curtain was applied on the top side of a frame(Shading and Ventilation Blocking Plot: SVP). The third was $1.5m(W){\times}1.5m(L){\times}1.5m(H)$, only the top side of which was covered by the shading curtain without the lateral film(Shading Plot: SP). The last plot was natural condition without any kind of shading and wind blocking material(Natural Open Plot: NP). Based on the 13,262 records of 44 sunny days, the time serial difference of AT and GT for 24 hour were analyzed and compared, and statistical analysis was done based on the 7,172 records of daytime period from 7 A.M. to 8 P.M., while the relation between the MRT and solar radiation and wind speed was analyzed based on the records of the hottest period from 11 A.M. to 4 P.M.. The major findings were as follows: 1. The peak AT was $40.8^{\circ}C$ at VP and $35.6^{\circ}C$ at SP showing the difference about $5^{\circ}C$, but the difference of average AT was very small within${\pm}1^{\circ}C$. 2. The difference of the peak GT was $12^{\circ}C$ showing $52.5^{\circ}C$ at VP and $40.6^{\circ}C$ at SP, while the gap of average GT between the two plots was $6^{\circ}C$. Comparing all four plots including NP and SVP, it can be said that the shading decrease $6^{\circ}C$ GT while the wind blocking increase $3^{\circ}C$ GT. 3. According to the calculated MRT, the shading has a cooling effect in reducing a maximum of $13^{\circ}C$ and average $9^{\circ}C$ MRT, while the wind blocking has heating effect of increasing average $3^{\circ}C$ MRT. In other words, the MRT of the shaded area with natural ventilation could be cooler than the wind blocking the sunny site to about $16^{\circ}C$ MRT maximum. 4. The regression and correlation tests showed that the shading is more important than the ventilation in reducing the MRT, while both of them do an important role in improving the outdoor thermal comfort. In summary, the results of this study showed that the shade is the first and the ventilation is the second important factor in terms of improving outdoor thermal comfort in summer daylight hours. Therefore, it can be apparently said that the more shade by the forest, shading trees etc., the more effective in conditioning the microclimate of an outdoor space reducing the useless or even harmful heat energy for human activities. Furthermore, the delicately designed wind corridor or outdoor ventilation system can improve even the thermal environment of urban area.