• Title/Summary/Keyword: 통신 제어 장치

Search Result 1,182, Processing Time 0.026 seconds

Development of FPGA Based HIL Simulator for PMS Performance Verification of Natural Liquefied Gas Carriers (액화천연가스운반선의 PMS 성능 검증을 위한 FPGA 기반 HIL 시뮬레이터 개발)

  • Lee, Kwangkook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.7
    • /
    • pp.949-955
    • /
    • 2018
  • Hardware-in-the-loop (HIL) simulation is a technique that can be employed for developing and testing complex real-time embedded systems. HIL simulation provides an effective platform for verifying power management system (PMS) performance of liquefied natural gas carriers, which are high value-added vessels such as offshore plants. However, HIL tests conducted by research institutes, including domestic shipyards, can be protracted. To address the said issue, this study proposes a field programmable gate array (FPGA) based PMS-HIL simulator that comprises a power supply, consumer, control console, and main switchboard. The proposed HIL simulation platform incorporated actual equipment data while conducting load sharing PMS tests. The proposed system was verified through symmetric, asymmetric, and fixed load sharing tests. The proposed system can thus potentially replace the standard factory acceptance tests. Furthermore, the proposed simulator can be helpful in developing additional systems for vessel automation and autonomous operation, including the development of energy management systems.

Implementation and Estimation of the LUTS Diagnosis System for Home Health Care (홈 헬스케어에 적용 가능한 하부요로계 폐색 모니터링 시스템 구현 및 평가)

  • Jeong Do-Un;Chung Wan-Young;Jeon Gye-Rork
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.697-700
    • /
    • 2006
  • A sensor and measuring system were implemented to measure two signals that uroflow and urophonography during urination for diagnose the lower urinary tract symptom. The implemented system was composed of the uroflow sensor using the load-cell, the urophonography measurement sensor so as stethoscope type, pre-processing part for sensors signal detection, amplifier and filter, system control parts and PC measurement program. A simulator of the lower urinary system that is experimental equipment implemented for evaluate the implemented system. The two signals were measured using implemented system and analyzed these signal by means of time domain and frequency domain for extraction of the characteristic parameter the most influence of effect according to occlusion of the lower urinary system. Furthermore two signals were measured and analyzed with the subject of 5 healthy adult for clinical application possibility of the implemented system. As a result, the most influence bandwidth of effect according to occlusion of the lower urinary system is $253\sim282Hz$ of the urophonography signal.

  • PDF

Joint Transceiver Design for SWIPT in MIMO Interference Channel (MIMO 간섭채널에서 정보와 전력의 동시 전송 (SWIPT)을 위한 송수신기 설계)

  • Seo, Bangwon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.5
    • /
    • pp.55-62
    • /
    • 2019
  • In this paper, we consider K-user multiple-input multiple-output (MIMO) interference channel and present a transceiver design for simultaneous wireless information and power transfer (SWIPT) systems. In addition, we consider a SWIPT system where an information decoding receiver and an energy harvesting receiver are co-located at the same receiver. In the proposed scheme, signal-to-leakage plus noise ratio (SLNR) is used as a cost function and a transceiver is designed to satisfy the threshold of the harvested energy. More specifically, transmitter precoding vector, receiver filter vector, and power spitting factor are simultaneously designed to maximize SLNR with a constraint on the harvested energy. Through computer simulation, we compare the signal-to-interference plus noise ratio (SINR) performance of the proposed and conventional schemes. When a special condition among the number of transmit antennas, receive antennas, and users is satisfied, the proposed scheme showed better SINR performance than the conventional scheme at low signal-to-noise ratio (SNR) range. Also, when the condition is not satisfied, the proposed scheme showed better performance than the conventional scheme at all SNR range.

The sputtering vacuum deposition of indium tin oxide thin film on a-Si:H thin film (비정질실리콘 박막위에서 ITO박막의 스퍼터링 진공 증착)

  • Hur, Chang-wu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.910-912
    • /
    • 2009
  • 투명전극은 비저항이 $1{\times}10^{-3}{\Omega}/cm$이하, 면저항이 $10^3{\Omega}/sq$이하로 전기전도성이 우수하고 380에서 780nm의 가시광선 영역에서의 투과율이 80%이상이라는 두 가지 성질을 만족시키는 박막이다. 기존의 평판디스플레이의 경우, 금속 산화물 투명전극이 진공 증착 공정을 통해 도포된 유리기판상의 각 화소를 포토리소그래피 공정으로 제조된 박막트랜지스터(TFT : Thin Film Transistor)로 제어함으로써 화상을 구현한다. 본 연구에서는 스퍼터링 진공 증착 장치를 이용하여 투명 도전막(ITO: Indium Tin Oxide)을 제작하고 제작된 ITO 박막의 광 및 전기 그리고 물성적 특성을 조사하여 최상의 공정 조건을 확립하였다. a-Si:H 박막위에 형성되는 ITo 박막은 a-Si:H 박막의 특성상 온도 및 스퍼터링 전력에 대한 연구가 주요 문제이다. 본 실험에서는 $In_2O_3:SnO_2$의 조성비는 90:10 wt% 인 타겟의 특성이 우수하였고, $Ar:O_2$의 분압비는 100:1 및 42:8 의 조건이 적당하였으며, 온도는 $200^{\circ}C$ 가장 우수한 특성을 얻을 수 있었다. $200^{\circ}C$ 는 비정질 실리콘의 성능에 좋은 영향을 미치는 온도이며, 알려진 것과 같이 $23^{\circ}C$ 즉 실온의 경우에 비해 막의 균질성 및 특성이 우수 한 것을 알 수 있었다. 본 연구에서 제작한 박막은 광 투과도가 90% 이상, 비저항이 $300{\mu}{\Omega}cm$ 이하의 특성을 갖게되어 이미지센서, 태양전지, 액정 텔레비젼등 빛의 통과와 전도성등 두가지 특성에 동시에 만족 될만한 성능을 가질 수 있음을 확인하였다.

  • PDF

Indoor environmental alarm robot (실내환경 오염 측정장치 알람봇 구현)

  • Cho, Hae-Jin;Lee, Hye-bin;Lee, Gi-Ho;Oh, Min-u;Choi, Ji-Seung;Kim, Su-Min;Kim, Seong-Hyeon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.549-551
    • /
    • 2016
  • In this paper, With the development of modern science and technology are Sheds to stay indoors rather than outdoors space it increased significantly compared to the past. And a wide variety of research about outdoor air quality until recently, efforts are underway but the issue of air quality in the room is the fact that all considered relatively lightly. As the contamination of the room air is polluted, unlike the natural environment, a large outdoor air dilution rate, the dilution rate is very low, once the contaminated air continuously circulating exerts a very bad influence on the health of people staying in the room. In this study, movement characteristics of the person living in a room, the air measuring device for the study of the active indoor environmental control system reflects the life form to measure the quality of the measured air in real time for transmitting the information to the user of the smart devices, alarm bot It was implemented and operational applications.

  • PDF

Design of BLDC Motor Control Circuit for Electric Driver using UC3625 Controller IC (UC3625 Controller IC를 이용한 전동 Driver용 BLDC 전동기 제어회로 설계)

  • Jeong, Sungin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.4
    • /
    • pp.129-134
    • /
    • 2021
  • A power tool is a tool used to manufacture and process various structures using a motor that is a power source. Using a motor that uses electricity as a power source, a reduction device, power transmission and conversion device functions are built-in to make the tool rotate, reciprocate, and vibrate. It is a work tool designed to assist the user's movement skills. In the case of Korea, the power tool industry has a short history and is lagging behind advanced countries such as Germany, the United States, and Japan in terms of technology level, market share, and recognition. In addition, electric drivers used in Korea are foreign products from the US and European countries, and the domestic market also prefers 100% foreign companies, and multinational companies are investing a lot in the domestic market. Therefore, technological development must follow in order to develop domestic technology and secure a consistently high market share. The purpose of this thesis is to design a motor driver with high output performance of motor performance, miniaturization, and high speed in accordance with the basic performance requirements of power tools, and finally research developments that can be applied to industrial and medical applications.

MPEG2-TS to RTP Transformation and Application system (MPEG2-TS의 RTP 변환 및 적용 시스템)

  • Im, Sung-Jin;Kim, Ho-Kyom;Hong, Jin-Woo;Jung, Hoe-Kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.643-645
    • /
    • 2010
  • The Internet-based multimedia services such as IPTV is being expanded with the development of technology to support the convergence of broadcasting and telecommunications technology for the control seems to be growing larger. Especially for the real-time TV broadcast multicast control technology to support the authentication and resource control, in addition to the technology services that enhance the value of technology for a variety of services in both directions seems to be developed. And, Internet-based transmission system transmit the video content for the video content delivery using RTP(Real Time Transport Protocol). Standardization body, IETF(Internet Engineering Task Force) within the RTP, according to a variety of audio and video formats only transmission format(RTP Payload Format) Establish a separate standard and scalable video content "RTP Payload Format for SVC(Switched Virtual Connection) Video" the standardization is currently processing. In this paper we are improving the quality of broadcasting and telecommunication systems, so that the upper layer by the application can react adaptively to the existing MPEG2-TS and RTP who are provided by a variety of content applied to a variety of devices consumers ETE(End- to-End) QoS(Quality of Service) for enhance the system who was designed and implemented.

  • PDF

A Study On Low Radiation Measurement of Radiation Measuring Devices and Improvement of Reaction Speed according to the Rapid Change of Radiation Dose (방사선 측정장치의 저준위 방사선 측정과 방사선량의 급격한 변화에 따른 장치의 반응 속도개선에 관한 연구)

  • Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.544-551
    • /
    • 2014
  • This paper suggests an algorithm to measure low-level radiation by radiation measuring devices, and the other algorithm to improve reaction speed of the device to better respond to dramatic changes in radiation amount. The former algorithm to improve the accuracy of measuring low-level radiation takes advantage of a dual window radiation measurement method which is based on accumulated average of pulses gathered by a radiation measuring sensor. The latter algorithm is to enhance reaction speed of a measuring device to more sensitively react to dramatic changes in radiation amount by adopting a dual window radiation measurement method which analyzes data patterns newly put into for six seconds. To verify the suggested algorithms, a hardware-which consists of sensor and high-voltage generator, controller, charger and power supply circuit, wireless communication part, and display part-was used. Tests conducted on the dual window radiation measurement method as used in the suggested algorithm have proved that accuracy improves to measure low-level radiation of 5uSv/h, and linearity also gets better. Other tests were conducted to see whether the suggested algorithm enhances the reaction speed of a radiation measuring device so that the device responds better to dramatically changing radiation amount. The experimental results have shown meaningful changes in numbers after six seconds. Therefore, the conclusions are made that the algorithm enhances the reaction speed of the device.

A Study On Hardware Design for High Speed High Precision Neutron Measurement (고속 고정밀 중성자 측정을 위한 하드웨어 설계에 관한 연구)

  • Jang, Kyeong-Uk;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.20 no.1
    • /
    • pp.61-67
    • /
    • 2016
  • In this paper, a hardware design method is proposed for high speed high precision neutron radiation measurements. Our system is fabricated to use a high performance A/D Converter for digital data conversion of high precision and high speed analog signals. Using a neutron sensor, incident neutron radiation particles are detected; a precision microcurrent measurement module is also included: this module allows for more precise and rapid neutron radiation measurement design. The high speed high precision neutron measurement hardware system is composed of the neutron sensor, variable high voltage generator, microcurrent precision measurement component, embedded system, and display screen. The neutron sensor detects neutron radiation using high density polyethylene. The variable high voltage generator functions as a 0 ~ 2KV variable high voltage generator that is robust against heat and noise; this generator allows the neutron sensor to perform normally. The microcurrent precision measurement component employs a high performance A/D Converter to precisely and swiftly measure the high precision high speed microcurrent signal from the neutron sensor and to convert this analog signal into a digital one. The embedded system component performs multiple functions including neutron radiation measurement for high speed high precision neutron measurements, variable high voltage generator control, wired and wireless communications control, and data recording. Experiments using the proposed high speed high precision neutron measurement hardware shows that the hardware exhibits superior performance compared to that of conventional equipment with regard to measurement uncertainty, neutron measurement rate, accuracy, and neutron measurement range.

The Design of an Infrared Transcutaneous Control Unit for Totally Implantable Middle Ear System (완전 이식형 인공중이를 위한 체외 및 체내 제어시스템 구현)

  • 정의성;강호경;박일용;윤영호;김민규;송병섭;원철호;조진호
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.5
    • /
    • pp.71-78
    • /
    • 2004
  • An infrared remote control-type transcutaneous control device using a $\mu$-processor is design for the totally implantable middle ear system. An infrared light transmission model for the tissue of skin was introduced and then a radiant intensity and the required current of the infrared light emitting diode(IR LED) driving circuit at transmission part were calculated for the external control device. And the transmission part generates IR signal by the system's own data protocol which prevents interferences from other infrared remote controls of the household appliances. The control part of the implanted device was designed to analyze functions of the received infrared(IR) signal that indicate the power ON/OFF and volume UP/DOWN. After the system is implemented, a data transmission experiments using 4 mm thickness of porcine skin were carried out. From the experiment, it was verified that the infrared control signal was transmitted to receiving module of the implemented system without any error.