• Title/Summary/Keyword: 통신 냉각 시스템

Search Result 42, Processing Time 0.028 seconds

Development of Passive Cooling System for Communication Cabinet by Latent Heat Material. (잠열재를 이용한 통신 캐비넷용 Passive 냉각시스템 개발)

  • Chung, Dong-Yeol;Park, Shung-Sang;Peck, Jong-Hyeon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1385-1390
    • /
    • 2009
  • In this study the purpose is development of passive cooling system for telecommunication cabinet used by latent heat material. This cooling system is not required for electronic power. It was tested for the performance of the telecommunication combined latent heat material with $48^{\circ}C$ of phase changed temperature and heat pipe. At $45^{\circ}C$ of outside temperature, when heater power was 1,000 W and 1,500 W, the inside temperature of the cabinet was $55^{\circ}C$ and $62^{\circ}C$. This system was showed better performance than the other systems.

  • PDF

Cooling Performance of a Hybrid Refrigeration System for Telecommunication Equipment (통신기기 냉각용 하이브리드 냉방시스템의 성능특성)

  • Jeon, Jong-Ug;Kim, Yong-Chan;Choi, Jong-Min
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.489-494
    • /
    • 2006
  • Electronic and telecommunication industries are constantly trying to develop compact components having high power density. Therefore, a proper heat dissipation method is very important to allow reliable operation of the telecommunication equipment. In this study, a hybrid refrigeration system for a telecommunication equipment room was designed to save energy consumption and improve reliability of the compressor In addition, the performance of the hybrid refrigeration system was measured with a variation of outdoor load. The designed hybrid refrigeration system for the telecommunication equipment shelter saved the energy approximately 50%e at the mode switch temperature of $8.3^{\circ}C$.

  • PDF

Design of I-123 Nuclide Production System (I-123 핵종생산장치 시스템 설계)

  • Jung, Hyun-Woo;You, Jae-Jun;Kim, Byung-Il;Lee, Dong-Hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.6
    • /
    • pp.1462-1468
    • /
    • 2014
  • Xe gas is moved to target from GPM. It is used to feasible nuclear reaction from proton of 30MeV cyclotron being investigated by the Xe-124 gas target system. This system is divided into four parts. The hardware system was constructed by solidworks 3-D CAD and Helium supply is to cool the Havor foil. The Cooling water has the job of cooling down the temperature when Xe gas is being investigated in the target. Temperature and pressure gauges are attached to be checked easily. GPM has the part that prepares to transport Xe gas. There are storage vessel that stores Xe gas, the cold trap that filters humidity and impurity and lastly storage vessel that temporarily stores Xe gas. HCS using the helium is to clean and cool for each part. These parts are configured with SIEMENS PLC and PcVue monitoring program for more comfortable and easy maintenance.

무선인터넷 기반의 소형무인선 개발

  • Kim, Hyo-Il;Jeon, Seung-Hwan
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2011.11a
    • /
    • pp.1-2
    • /
    • 2011
  • 최근 많은 분야에 무인시스템이 도입되고 있다. 초기에는 산업분야에서 인간이 하기 힘들거나 위험한 작업을 대신하는 단순 반복적인 자동화기술이 대부분이었으나, 최근에는 전자통신 기술발달에 힘입어 무인자동차, 무인항공기, 무인잠수정, 무인선박 등이 연구 개발되고 있다. 본연구에서는 자율형 소형무인선을 개발하고자 하였으며, 이와 관련하여 인터넷기반의 무선통신제어, 동력 추진 조타 냉각시스템, GPS 영상 헤딩센서 등 센싱시스템, 자율운항을 위한 제어기설계, GUI 등을 연구하였다. 아울러, 해상실험을 통해 유효성을 검증하였다.

  • PDF

A Study on the Operating Characteristics for a small scale CPL (소형 CPL의 작동 특성에 관한 연구)

  • 안영길;유성열;임광빈;김철주
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.05a
    • /
    • pp.97-105
    • /
    • 2002
  • 최근 5년 사이의 급속한 정보통신의 발전과 전자소자의 고집적화, 소형화는 전자장비 내부의 열부하 증가를 초래하고 있다. 이에 효과적으로 열을 제거하는 기술개발 요구로 다양한 이상 열전달 시스템(two-phase systems)이 연구되고 있다. CPL(Capillary Pumped Loop) 기술은 1960년대 미국, 구소련에서 우주항공분야의 전자장비 온도제어 시스템으로 주로 통신위성 또는 우주선의 전자장비 냉각기술의 한 방법으로 사용되어 왔으며 NASA Lewis Research Center의 Stenger에 의해 처음 제안되었다.(중략)

  • PDF

Cooling performance of an electronic system including electronic components mounted with heat sink (히트 싱크 부착 전자부품을 가진 통신시스템의 냉각성능 연구)

  • No, Hong-Gu;Lee, Jae-Heon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.2
    • /
    • pp.253-266
    • /
    • 1998
  • A numerical study on the cooling performance for electronic components mounted with heat sink in an electronic system has been performed. The model of electronic system consisted with lower and upper modules in which the electronic components mounted with heat sink were arrayed. To find better configuration under a given fan power for effective cooling, the cases called 'No heat sink','Both heat sinks','Lower heat sinks', and 'Upper heat sinks' were tested. The results showed that the cooling performance in 'Upper heat sinks' was the best among four cases.

Automation System of Explosion-Proof Panel Condition (방폭 패널 컨디션 자동화 시스템(1))

  • Hwang, Dae-Hyeon;Choi, Kwang-Il;Bae, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.2
    • /
    • pp.253-258
    • /
    • 2020
  • Petrochemical industry complex in Korea always has high riskiness due to explosive and inflammable gases. To prevent these explosion, most facility of petrochemical industry complex requires the performance of explosive proof. The control panel, which is used as explosive proof, has been used the air injection method by manually from outside to constantly keep the temperature and pressure between inside and outside of the panel. In this paper, we propose the automatic temperature controller, which performs automatic heating and cooling according to temperature inside the panel in order to control temperature automatically.

The Development of fault Monitoring System in Internal Heat Exchanger (열교환기 내부의 결함 감시 시스템 개발)

  • Kim, Gwan-Hyung;Jeong, Hoi-Seong;Lee, Hyung-Ki
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.552-553
    • /
    • 2012
  • 현재의 발전소 내부에 가동 중인 열교환기 배관 라인의 Clinker Monitoring System은 초고온의 열교환기 내부의 벽면 및 배관라인의 클링커 상태를 감시하는 시스템을 요구하고 있다. 이러한 열교환기 내부의 상태를 감시하기 위하여 초고온에 견딜 수 있고 회전이 가능한 장치를 열교환기 내부에 투입하여 회전 가능한 장치를 통하여 원격으로 영상을 전송하도록 하여 클링커 상태를 영상으로 모니터링 하여 열교환기 내부의 상태를 감시 관찰 분석할 수 있는 시스템을 구성하였다. 본 논문에서는 발전설비의 열교환기 내부의 클링커 상태를 모니터링 할 수 있도록 회전 가능한 렌즈 튜브와 보호용 냉각 시스템을 추가된 통합 모니터링 시스템을 제기하고자 한다.

  • PDF

Development of Cooling/Warming System Using Thermoelectric Device (열전소자를 이용한 냉·온장시스템 개발)

  • Kim, Kee-Hwan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.3
    • /
    • pp.131-136
    • /
    • 2009
  • The thermoelectric effect is the direct conversion of temperature differences to electric voltage and vice versa. A thermoelectric device creates a voltage when there is a different temperature on each side. Conversely when a voltage is applied to it, it creates a temperature difference. This effect is used in this paper to cool objects or to heat them. A cooling/warming system with thermoelectric device is introduced and controlled with PC and LabVIEW.

  • PDF

Multi-kW Fiber Laser Applications (고출력 Fiber Laser Applications)

  • Han, Yu-Hui
    • Proceedings of the KWS Conference
    • /
    • 2005.06a
    • /
    • pp.80-81
    • /
    • 2005
  • 그동안 고출력 레이저에는 CO2 Laser, LPSSL, DPSSL 등이 주로 사용되어 왔다. 최근에는 Fiber Laser가 좋은 빔특성을 가지면서 10kW이상의 고출력이 가능해 큰 주목을 받고 있다. 고출력 레이저는 매질의 냉각문제가 가장 큰 관건인데, Fiber Laser는 수백 ${\mu}m$의 지름을 가진 수십m 길이의 공진기 형태를 띠어 부피 대비 냉각면적이 가장 크다고 할 수 있다. EDFA 둥 광통신을 위해 개발되었던 다이오드 레이저들이 Fiber Laser쪽으로 전용되고, Side Cladding pumping 방법의 실용화, 다이오드레이저 펌핑 광과 광섬유사이의 커플링 방법이 개발되면서 고출력 Fiber Laser 개발이 급속히 이루어졌다. Fiber Laser는 시스템의 부피가 매우 작아질 뿐만 아니라 유지관리 비용이 거의 들어가지 않는다는 장점을 가진다. 현재 단일모드(single-mode) 로는 300W의 출력이 가능하고, 이들을 결합하여10kW 이상의 고출력 Fiber Laser 제품이 나오고 있다. 높은 효율의 레이저발진을 하면서 고출력의 좋은 빔특성을 가지기 때문에 기존의 고출력 레이저용접 및 절단 응용분야에 큰 관심을 불러일으키고 있다.

  • PDF