• Title/Summary/Keyword: 통수성

Search Result 180, Processing Time 0.035 seconds

A Pilot Test of Various Vertical Drains and its Initial Monitoring Results (다양한 연직배수재의 시험시공 및 초기현장 계측)

  • Kim, Ju-Hyong;Cho, Sam-Deok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.5 no.2
    • /
    • pp.45-50
    • /
    • 2006
  • Although the discharge capacity of the natural fiber drains are very low compared to that of plastic drain board (PDB), it is found that the conventional fiber drains and the new developed straw drain boards have great potential for use as a substitute for conventional plastic drain boards through several model tests. To verify their field application, a pilot test using environmentally friendly drains is also being carried out to prove their effective discharge capacity in the field. The pilot test site was divided into 5 different areas, with various combinations of vertical and horizontal drains installed for evaluation. Definite characteristics of various drains are still to be found due to the delay in construction of embankment. Consolidation behavior of three types of vertical drains and two types of horizontal drains will be analyzed after the completion of the embankment in the near future.

  • PDF

Reviews on the Upstream Characteristic of Weir Influenced by Gate Operation at the Gumi Weir in Nak-Dong River (낙동강 구미보의 수문운영에 따른 보 상류부 영향 검토)

  • Jang, Dong-Woo;Choi, Gye-Woon;Han, Man-Shin;Jung, Jae-Kwang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.194-194
    • /
    • 2011
  • 보는 일반적으로 흐르는 하천을 막아 수위를 높여서 취수 용도로 사용되는 저수 시설의 역할을 한다. 그러나 홍수 시 보 구조물은 홍수류 소통의 장애물 역할을 하여 보 상류의 수위를 상승시키고, 이는 곧 보의 상류에서는 침수피해를 발생시키기도 한다. 따라서 홍수 시 보 구조물이 하천흐름을 방해하지 않도록 설계하여 보의 통수능과 안정성을 확보시키는 것은 보 설계 시에 매우 중요한 요인으로 작용한다. 본 연구에서는 낙동강 구미보를 대상으로 보 구조물에 의한 보 상류부의 통수능 및 치수안정성에 대해 분석하기 위하여 수리모형실험을 수행하였다. 가동보의 수문 운영 조건에 따른 보 상류부의 수위 변화, 빈도 홍수량에 의한 구미보 상류의 흐름특성을 유속 및 수위측정을 통하여 비교 분석하였다. 구미보의 수문 2개를 이용하여 수문 2개 개방 조건, 수문 1 개 개방, 수문 1개 폐쇄 조건, 수문 2개 폐쇄 조건으로 구분하여 실험을 진행하여 분석하였다. 연구 결과 수문폐쇄조건에서 수위가 가장 크게 나타났으며 급격히 상승하였다. 수문이 폐쇄된 2년 빈도의 홍수량조건이, 수문이 개방된 100년 빈도 홍수량조건보다 상류수심이 높게 형성되는 것을 확인할 수 있었다. 따라서 실제 계획홍수량보다 작은 유량조건일지라도 수문이 폐쇄됐을 경우에 보 상류부는 홍수범람의 위험이 더욱 커진다고 판단되었다. 가동보 수문을 개방하여 통수하는 경우에 보 상류의 수위저하 영역을 검토한 결과, 유량이 클수록 가동보에 의해 수심저하 영향을 받는 보 상류의 영역이 늘어나며, 보 상류 방향으로 거리에 따른 보 상류의 수심저하가 발생하는 거리의 관계는 유량 크기에 비례하는 것으로 나타났다.

  • PDF

Conveyance Verification through Analysis of River Vegetation and Soil Impact using Sentinel-2 (Sentinel-2를 활용한 하천의 식생 및 토양 영향 분석을 통한 통수능 검정)

  • Bang, Young Jun;Choi, Byeong Jun;Lee, Seung Oh
    • Journal of Korean Society of Disaster and Security
    • /
    • v.14 no.4
    • /
    • pp.37-45
    • /
    • 2021
  • Flooding damage may occur due to an unexpected increase in rainfall in summer. Previously, the roughness coefficient, which is a major factor of conveyance, was calculated through on-site measurement, but in case of on-site measurement, there are many limits in accurately grasping changes in vegetation. In this study, the vegetation index (NDVI) was calculated using the Sentinel-2 optical images, and the modified roughness coefficient was calculated through the density and distribution area of the vegetation. Then the calculated roughness coefficient was applied to HEC-RAS 1D model and verified by comparing the results with the water level at the water level station directly downstream of the Soyang River dam. As a result, the error rate of the water level decreased about 14% compared to applying the previous roughness coefficient. Through this, it is expected that it will be possible to refine the flood level of rivers in consideration of seasonal flood characteristics and to efficiently maintain rivers in specific sections.

An Experimental Study on the Change of Hydraulic Characteristics by the Training Wall (합류부에 도류제 설치에 따른 흐름 개선효과에 관한 실험적 연구)

  • Choi, Gye-Woon;Chae, Sin-Ae;Chang, Yun-Gyu;Hwang, Young-Man
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.561-564
    • /
    • 2010
  • 하천의 본류와 1개 이상의 지류가 만나는 합류부에서는 본류 흐름과 지류 흐름이 충돌함에 따른 흐름 정체가 빈번하게 일어난다. 이로 인하여 태풍이나 집중호우 시 유속저하와 수위증가로 통수능이 크게 저감되어 홍수피해위험이 크게 증가하는 경향을 보인다. 도류제는 흐름의 원활한 소통을 위하여, 흐름방향을 조정해주는 인공구조물로서 수제의 한 종류이며, 합류부에서의 흐름 정체현상을 해소할 수 있는 한 방법으로 알려져 있으나, 국내에서는 도류제의 적용이 주로 해안의 사빈방지 등에 이루어지고 있으며, 하천의 합류부에서의 적용사례를 찾아 보기는 힘들다. 이 연구에서는 본류와 지류가 만나는 합류구간을 지닌 자연형 사행하천을 대상으로 한 수리모형 실험장치를 이용하여, 도류제의 합류부의 흐름개선 효과를 분석하였다. 수리모형실험의 조건은 도류제 설치 전 후, 도류제 길이 변화에 따라 구성되었으며, 실험결과 도류제의 설치는 본류흐름, 지류흐름, 합류 후 흐름의 수위, 유속, 흐름방향 등의 흐름 특성을 변화시켰다. 특히, 실험조건에 따라 하도의 통수능 증대효과가 다르게 나타났으며, 도류제 설치길이에 따른 변화를 확인하였다. 본 연구 결과를 통해 하천 합류부에 도류제 등의 홍수저감시설을 적용할 시 합류부의 수위 및 유속 등의 수리특성 변화를 예측함으로 합류부 흐름개선을 위한 하천개수계획 등에 유용한 자료로 활용될 것으로 사료된다.

  • PDF

Calculation of the Appropriate Size of Gutter Storage System to Reduce Urban Inundation (내수침수 저감을 위한 측구 저류조의 적정규모 산정)

  • Lee, Sung Ho;Lee, Jae Joon;Park, Hee Seob;Lee, Hoo Sang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.359-359
    • /
    • 2022
  • 빈번하게 발생되는 설계빈도 이상의 국지성 호우로 도시지역의 침수피해가 매년 증가하고 있고 특히 저지대의 경우 우수의 집중 및 하수관거의 통수능 부족으로 인한 우수의 배수 불량으로 다른 지역에 비해 침수피해의 규모가 크게 나타나고 있다. 매년 반복되는 피해를 저감하기 위하여 국가 및 지자체에서는 노후관거 개량 및 통수능 확보를 위한 하수관거 신설 등 다양한 방법을 동원하고 있으나 하수관거 개량 및 신설 또는 지하저류조 설치와 같은 사업들은 많은 예산이 필요하여 지자체의 규모에 따라 예산확보가 어려울 수 있고 해당 사업을 완료하기 위한 사업기간이 오래 걸리므로 즉각적인 효과를 기대하기 어려운 실정이다. 따라서 기존 침수저감을 위한 시설을 설치하기 위한 사업에 비해 예산이 적게 소모되며, 큰 설치부지를 요구하지 않는 유출저감시설이 필요하다고 판단된다. 본 연구에서는 도로부의 노면수를 배수하기 위한 시설인 측구를 우수의 저류를 위한 저류조로 활용한 측구 저류조 개념을 이용하여 도시지역에서 침수저감을 위한 적정규모 산정을 위한 연구를 진행하였다. 빈도 30년의 강우를 적용하여 일반적인 지하저류조를 설치하였을 경우와 측구 저류조를 설치하였을 때의 침수저감효과를 비교하고 지하저류조와 비슷한 저감효과를 나타내기 위한 적정규모 산정과 측구 저류조의 배치방법을 제시하고자 한다.

  • PDF

Performance Evaluation Systems in Water Distribution Network (상수관망의 성능평가를 위한 진단체계 구축)

  • Kim, Ju-Hwan;Kim, Jung-Hyun;Lee, Doo-Jin;Woo, Hyung-Min;Bae, Cheol-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.864-868
    • /
    • 2008
  • Water transmission and distribution systems play a important role to deliver safe and clean water and are responsible for the most direct impacts of water utilities to customers. Although the performance of WDS(Water Distribution Systems) should be evaluated by a certain standards, interests has not been in WDS and developed due to invisible, hard-working and insufficient information in the evaluation process in Korea till now. The investigations and researches were carried out to develop software to assist the evaluation of WDS with respects to hydraulics, water quality and structural analysis methods. The methodologies have been developed which can be used to estimate the performance to water distribution network and software are implemented by the process. Developed systems are consisted with database, analysis techniques, simulation models, decision support systems and other tools. The concepts and functions are introduced in this paper and the performance index are discussed for accurate assessment of water distribution systems.

  • PDF

An Experimental Verification on the Efficiency of Geosynthetics on Crushed Stone Layer (쇄석배수층에 적용된 토목섬유의 효율성에 대한 실험적 검증)

  • Park, Min-Cheol;Im, Eun-Sang;Kim, Jae-Hong;Han, Heui-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.11
    • /
    • pp.17-27
    • /
    • 2013
  • This study is to prove the efficiency of geo-synthetics on the crushed stone layer by experiments. The strength of PET mat as reinforcing soft ground was verified through the loading experiments. Also, PP mat was used to protect the blockage of crushed stone layer by the filled soil, whose efficiency was examined according to loading and infiltration conditions. The crushed stones were penetrated into clay layer if the PET mat was removed, which was verified by loading experiments. In addition, the cohesioness of soil without PP mat made the blockage of stone layer easily, which reduced the infiltration capacity by about 98%.

Application of Low Impact Development Techniques in Flooding Areas (침수위험지역의 저영향개발기법 적용)

  • Woo, Won Hee;Lee, hanyong;Park, Youn Shik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.189-189
    • /
    • 2019
  • 도시화에 따른 토지이용패턴의 변화로 불투수면적이 증가하여 빗물의 침투량이 감소하고, 유출량은 증가하는 등 집중호우시 침수피해를 야기하게 된다. 또한 오염원의 증가로 수질오염과 지하수고갈에 따른 건천화 등 부정적 효과를 초래하는 것으로 알려져 있다. 최근 기후변화에 따라 물순환 체계가 변화하고 있으며, 이로 인해 도시의 홍수 및 가뭄이 극심해지고 시민의 삶의 질도 위협받고 있다. 우리나라의 경우 지속적으로 도시화 및 불투수면적이 증가하고 있으며, 집중호우의 발생빈도 또한 높아 심각한 수자원 물재와 홍수피해위험이 높다. 이에 도시의 물환경 변화 및 왜곡된 물순환 체계를 지속가능하도록 개선해야 할 필요성이 제기되었다. 환경부 및 국토부 등 정부기관에서는 물환경지속가능성을 위하여 저영향개발 기술요소를 도입하고 적용하고 있다. 본 연구에서는 침수위험지역의 저영향개발기법을 도입하여 유출저감 효과를 모의하고, 경제성 분석을 하였다. 본 연구의 대상지역은 경상남도 김해시 안동지구이며, 면적 364.2ha, 투수층면적 160.7ha, 불투수층면적 203.5ha로 불투수율은 55.90%로 산정되었다. 대상지역인 안동지구 우수관로현황 조사결과 (30년빈도 강우강도 적용) 관로의 통수능 검토시 전체관로 26.97km 중 통수능 부족관로는 15.60km로 전체대비 약 57.8%로 나타났다. 안동지구 내 우수관거는 간선관로의 경우 10년빈도, 지선관로의 경우 5년빈도로 설계, 시공되어 있으므로 각종 공단이 입지한 시가지인 안동지구는 도로포장등으로 인해 불투수층이 대부분을 차지해, 강우시 도로표면 유출수의 증대로 침수피해가 가중되는 것으로 판단되었다. 이에 저영향개발기법을 적용하여 맨홀로 유입되는 직접유출(DCIA, Directly Connected Impervious Area)를 줄이고, 유지관리 등을 고려하여 경제성을 평가하여 향후 침수위험지구 관거개량시 저영향개발기법을 활용할 수 있도록 하고자 한다.

  • PDF

Experimental Investigation of Water Discharge Capability According to Shape of Sluice for Tidal Power Generation - I. Physical Experiment (조력발전용 수문 형상에 따른 통수성능에 관한 실험적 연구 - I. 수리모형실험)

  • Lee, Dal-Soo;Oh, Sang-Ho;Yi, Jin-Hak;Park, Woo-Sun;Cho, Hyu-Sang;Kim, Duk-Gu
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.1
    • /
    • pp.73-80
    • /
    • 2008
  • An hydraulic experiment was carried out in an open channel flume in order to improve the technique of designing shape of the sluice used for tidal power generation, which greatly affects the economical efficiency of the construction of a tidal power plant. To predict the influence of change in the major design parameters relating to the sluice shape on the water discharge capability of the sluice, it was necessary to perform a precise experiment that is discriminated to previous feasibility studies or design projects. For this purpose, by installing various flow straighteners and rectifying structures inside the water supply system and the rectifying tank, the flow in the flume was stabilized as tranquil as possible. In addition, the measuring instruments and the location of installing them were carefully determined so as to minimize the errors intervened during the measurement of water discharge and water level. The method of estimating head difference between upstream and downstream of the sluice was also developed by taking account of the head loss due to the friction at the bottom and side walls in the flume.

An Analysis of the Composite Discharge Capacity Effect with GCP Method (GCP공법의 복합통수능 효과 분석)

  • Park, Minchul;Kwon, Hyukchan;Shin, Hyohee;Jang, Gisoo;Lee, Song
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.12
    • /
    • pp.37-46
    • /
    • 2011
  • An application frequency of vertical drainage method is increasing as an effective consolidation acceleration method. PBD method is most frequently used as a consolidation acceleration method in vertical drainage methods. PBD is economical and easy to operate but has some problems those are an environmental pollution and a decrease of a discharge capacity caused by bending of drainage materials when it is used in great depth. SCP method was frequently used because it's discharge capacity was good but now it is rarely used because of an increase of the material price because of an order imbalance. As the way to solve these problems, GCP method has been to the fore. For analyzing the effect of GCP method on the discharge capacity, three types of composite discharge capacity tests are done by using GCP, SCP and PBD respectively with the circle case, ${\phi}38{\times}h70cm$. On the contrary to this, GCP shows the worst discharge capacity for a decrease of the void ratio and the clogging phenomenon caused by increasing load. Also to figure out the clogging range of GCP, the clogging of GCP is checked in each load stage with a large case($1.0m{\times}0.5m{\times}1.1m$) which has clear acrylic front face. The diameter of GCP was 35cm and a clogging phenomenon occurred in 10% approximately. The result shows that the discharge capacity of GCP was given the lowest value for a decrease of the void ratio and the clogging phenomenon causing by increasing load. And the clogging phenomenon mostly occurred within 10% of GCP's diameter range.