• Title/Summary/Keyword: 통계적인 측정기

Search Result 20, Processing Time 0.023 seconds

Anisotropy of shear strength according to roughness in joint surface (절리면 거칠기에 의한 전단강도 이방성)

  • 이창훈;정교철
    • The Journal of Engineering Geology
    • /
    • v.12 no.4
    • /
    • pp.421-437
    • /
    • 2002
  • In order to quantify the anisotropic properties of rock included joints and shear behavior in joint surface, the mold is Produced for rock joint surface using gypsum Plaster and Peformed for replicated joint models made of cement mortar. Rock sample is measured using mechanical profilometer before testing and their result is expressed quantitatively. The statistical parameters and the fractal dimension by fractal theory for roughness is investigated its coordinate value for numerical process. The shear strength to the shear displacement in low level normal stress ismaintained or increased in most joint models. Their results present that this relationship is depended several roughness properties in joint model for natural rock joint. The relationship between the shear strength and the Properties for profiles estimated by some statistical parameter in roughness has the low correlation and is not constant. The result between the data for direct shear test and using Barton's equation, Barton's equation has not the effectiveness for the effect of anisotropy and has not suitable to recognizing the properties for joint surface. It means that JRC has not the properties of anisotropic rock surface. The fractal dimension is well correlated with the data of direct shear test than those of JRC. New experimental formulae using fractal dimension is comported with the anisotropic properties for direct shear test.

In vivo evaluation of accuracy and consistency of two electronic apex locators (2종 전자근관장측정기의 정확도 및 일관성에 관한 in vivo 연구)

  • Pi, Chien-Yun;Kim, Eui-Seong;Jung, Il-Young;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.6
    • /
    • pp.453-460
    • /
    • 2010
  • Objectives: To evaluate the accuracy and consistency of two different apex locators at both the Apex and 0.5 marks. Materials and Methods: Twenty-six root canals was scheduled for extraction for periodontal or prosthodontic reasons. Thirteen canals were measured using Root ZX and the rest by i-ROOT. The root canal length was measured both the at 0.5 mark and the Apex mark. The file was then fixed to the toot, and the distance from the file tip to the major foramen of each canal was measured after removing the root dentin under the microscope so that the major foramen and the file tip were seen. Results: 1. When the Apex mark was used, 100% of both the Root ZX and i-ROOT groups were within 0.5 mm of the major foramen. 2. When 0.5 mark was used, 100% of the Root ZX group and 77% of the i-ROOT group were within 0.5 mm of the major foramen. 3. In terms of standard deviation and quartile value, the Apex mark was more consistent than 0.5 mark in the Root ZX group, and 0.5 mark was more consistent in the i-ROOT group, but there was no statistically significant difference when compared with t-test. 4. The root canal length difference between the Apex mark and 0.5 mark was 0.22 mm and 0.46 mm in the Root ZX and i-ROOT groups, respectively. Conclusions: In this study, the Apex mark was the more consistent mark. Therefore, it is recommended to subtract 0.5 mm, which is the average length between the apex and apical constriction, from the root canal length at the Apex mark to obtain the working length clinically.

Expression of CD40, CD86, and HLA-DR in CD1c+ Myeloid Dendritic Cells Isolated from Peripheral Blood in Primary Adenocarcinoma of Lung (원발성 폐선암환자의 말초혈액에서 분리한 CD1c+ 골수성 수지상 세포에서의 CD40, CD86 및 HLA-DR의 발현)

  • Kang, Moon-Chul;Kang, Chang-Hyun;Kim, Young-Tae;Kim, Joo-Hyun
    • Journal of Chest Surgery
    • /
    • v.43 no.5
    • /
    • pp.499-505
    • /
    • 2010
  • Background: There have been several reports using animal experiments that CD1-restricted T-cells have a key role in tumor immunity. To address this issue, we studied the expression of markers for CD1c+ myeloid dendritic cells (DCs) isolated from peripheral blood in the clinical setting. Material and Method: A total of 24 patients with radiologically suspected or histologically confirmed lung cancer who underwent pulmonary resection were enrolled in this study. The patients were divided according to histology findings into three groups: primary adenocarcinoma of lung (PACL), primary squamous cell carcinoma of lung (PSqCL) and benign lung disease (BLD). We obtained 20 mL of peripheral venous blood from patients using heparin-coated syringes. Using flow-cytometry after labeling with monoclonal antibodies, data acquisition and analysis were done. Result: The ratio of CD1c+CD19- dendritic cells to CD1c+ dendritic cells were not significantly different between the three groups. CD40 (p=0.171), CD86 (p=0.037) and HLA-DR (p=0.036) were less expressed in the PACL than the BLD group. Expression of CD40 (p=0.319), CD86 (p=0.036) and HLA-DR (p=0.085) were less expressed in the PACL than the PSqCL group, but the differences were only significant for CD86. Expression of co-stimulatory markers was not different between the PSqCL and BLD groups. Expression of markers for activated DCs were dramatically lower in the PACL group than in groups with other histology (CD40 (p=0.005), CD86 (p=0.013) HLA-DR (p=0.004). Conclusion: These results suggest the possibility that CD1c+ myeloid DCs participate in control of the tumor immunity system and that low expression of markers results in lack of an immune response triggered by dendritic cells in adenocarcinoma of the lung.

Analysis of Drapability of Men's & Women's Suit Fabrics (남녀 수트직물의 드레이프성 분석)

  • Lee, Mee-Sik;Kim, Eui-Kyung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.12 s.159
    • /
    • pp.1723-1729
    • /
    • 2006
  • Drapability is an important factor determining the end-use of fabrics. In this research, characteristics of drapability of men's and women's suit fabrics were analyzed. The hand and the preference for suit fabrics were measured by the subjective and objective evaluations. To find out the details of the drapability characteristics of suit fabrics, the drape was measured by using Cusick drape tester and was processed by image analysis software. Seasonal difference was obvious both in men's and women's fabrics. The average drape ratio of women's S/S suit fabrics showed the highest value, 0.724, then decreased in the order of men's F/W> men's S/S> women's FW. Wave amplitude showed the same order to the drape ratio. Men's fabrics were more drapable in spring and summer season rather than in fall and winter season. Women's fabrics showed the opposite trend, in other words, S/S suit fabrics were less drapable than F/W fabrics. There was also a significant difference in drape ratio between men's and women's fabrics regardless of season. For S/S, men's fabrics were more drapable than women's ones, whereas, for F/W, women's fabrics were more drapable.

Embedded System Reliability Measurement Use Markov Chain Model (마르코프 체인 모델을 이용한 임베디드 시스템 신뢰도 측정)

  • Kawk Dong-Gyu;Cho Yong-Yoon;Park Ho-Byung;Yoo Chea-Woo
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.07b
    • /
    • pp.433-435
    • /
    • 2005
  • 임베디드 시스템은 다수의 디바이스를 컨트롤하여 시스템의 목적을 수행한다. 최근 임베디드 시스템의 요구사항이 증가함에 따라 하나의 임베디드 소프트웨어가 컨트롤하는 디바이스의 종류가 다양해지고 수도 증가하는 추세이다. 다수의 디바이스를 가지고 있는 임베디드 시스템에서 시스템의 신뢰도는 각 디바이스의 신뢰도에 많은 영향을 받는다. 본 논문은 임베디드 시스템의 신뢰도를 측정하기 위해서 통계적 신뢰도 측정 방법 중 한 가지인 마르코프 체인을 이용한 방법을 제안한다. 마르코프 체인은 여러 분야에서 복잡한 시스템을 단순화하여 모델링하고 과거의 변화를 토대로 미래를 예측할 수 있는 방법을 제공한다. 또한 전체 시스템의 확률을 행렬로 계측할 수 있는 방법을 가지고 있어 특정 부분의 확률이 전체 시스템의 확률에 미치는 영향을 산술적으로 계산할 수 있는 장점을 가지고 있다. 본 논문에서 제안하는 임베디드 소프트웨어 마르코프 체인은 테스트 대상 소스를 분석하여 디바이스를 컨트롤하는 루틴과 에러를 핸들링하는 루틴, 일반적인 루틴으로 나누어 각각을 상태로 정의한다. 정의한 각 상태간의 전이는 통계적으로 측정한 디바이스 신뢰도를 확률로 표현한다. 마르코프 체인을 이용하여 임베디드 시스템의 신뢰도를 측정하기 위한 시스템은 소스 분석기와 신뢰도 측정기로 나누어 설계한다. 소스 분석기는 테스트 대상이 되는 소스와 디바이스 드라이버 라이블러리 테이블을 입력으로 하고 소프트웨어의 마르코프 체인을 출력으로 한다 마르코프 체인은 행렬로 표현하고 연산하여 시스템의 신뢰도를 측정한다. 제안하는 시스템의 신뢰도 측정 방법은 부분이 가지고 있는 신뢰도가 전체 신뢰도에 미치는 영향을 산술적으로 측정할 수 있어 시스템이 요구하는 신뢰도에 접근할 수 있는 방법과 근거를 제공하는 장점이 있다.소시키는 장점을 갖는다.것으로 조사되었으며 40대 이상의 연령층은 점심비용으로 더 많은 지출을 하고 있는 것으로 나타났다. 4) 끼니별 한식에 대한 선호도는 아침식사의 경우가 가장 높았으며, 이는 40대와 50대에서 높게 나타났다. 점심 식사로 가장 선호되는 음식은 중식, 일식이었으며 저녁 식사에서 가장 선호되는 메뉴는 전 연령층에서 일식, 분식류 이었으며, 한식에 대한 선택 정도는 전 연령층에서 매우 낮게 나타났다. 5) 각 연령층에서 선호하는 한식에 대한 조사에서는 된장찌개가 전 연령층에서 가장 높은 선호도를 나타내었고, 김치는 40대 이상의 선호도가 30대보다 높게 나타났으며, 흥미롭게도 30세 이하의 선호도는 30대보다 높게 나타났다. 그 외에도 떡과 죽에 대한 선호도는 전 연령층에서 낮게 조사되었다. 장아찌류의 선호도는 전 연령대에서 낮았으며 특히 30세 이하에서 매우 낮게 조사되었다. 한식의 맛에 대한 만족도 조사에서는 연령이 올라갈수록 한식의 맛에 대한 만족도는 낮아지고 있었으나, 한식의 맛에 대한 만족도가 높을수록 양과 가격에 대한 만족도는 높은 경향을 나타내었다. 전반적으로 한식에 대한 선호도는 식사 때와 식사 목적에 따라 연령대 별로 다르게 나타나고 있으나, 선호도는 성별이나 세대에 관계없이 폭 넓은 선호도를 반영하고 있으며, 이는 대학생들을 대상으로 하는 연구 등에서도 나타난바 같다. 주 5일 근무제의 확산과 초 중 고생들의 토요일 휴무와 더불어 여행과 엔터테인먼트산업은 더욱 더 발전을 거듭하고 있으며, 외식은 여행과 여가 활동의 필수적인 요소로써 그 역할을 일조하고 있다. 이와 같은 여가시간의 증가는 독신자들에게는 좀더 많은 여유시간을 가족을 이루고 있는 가족구성원들에게는 가족과의 유대를 강화하는 휴식과 오락의 소비 트렌드를 창출시켰

  • PDF

LOCAL TIMES OF GALACTIC COSMIC RAY INTENSITY MAXIMUM AND MINIMUM IN THE DIURNAL VARIATION (우주선 세기 일변화 최대 및 최소 지방시)

  • Oh Su-Yeon;Yi Yu
    • Journal of Astronomy and Space Sciences
    • /
    • v.23 no.2
    • /
    • pp.117-126
    • /
    • 2006
  • The Diurnal variation of galactic cosmic ray (GCR) flux intensity observed by the ground Neutron Monitor (NM) shows a sinusoidal pattern with the amplitude of $1{\sim}2%$ of daily mean. We carried out a statistical study on tendencies of the local times of GCR intensity daily maximum aad minimum. To test the influences of the solar activity and the location (cut-off rigidity) on the distribution in the local times of maximum and minimum GCR intensity, we have examined the data of 1996 (solar minimum) and 2000 (solar maximum) at the low-latitude Haleakala (latitude: 20.72 N, cut-off rigidity: 12.91 GeV) and the high-latitude Oulu (latitude: 65.05 N, cut-off rigidity: 0.81 GeV) NM stations. The most frequent local times of the GCR intensity daily maximum and minimum come later about $2{\sim}3$ hours in the solar activity maximum year 2000 than in the solar activity minimum you 1996. Oulu NM station whose cut-off rigidity is smaller has the most frequent local times of the GCR intensity maximum and minimum later by $2{\sim}3$ hours from those of Haleakala station. This feature is more evident at the solar maximum. The phase of the daily variation in GCR is dependent upon the interplanetary magnetic field varying with the solar activity and the cut-off rigidity varying with the geographic latitude.

A Comparison of Cardiopulmonary Function, RPE, and Blood Lactate following in Wheelchair Treadmill and Arm Ergometer GXT Test through Convergence (융복합을 활용한 휠체어 트레드밀과 암에르고미터 점증부하운동검사 시 심폐기능, 운동자각도 및 젖산농도 비교)

  • Jang, Hong-Young;Kim, Jong-Hyuck
    • Journal of Digital Convergence
    • /
    • v.14 no.9
    • /
    • pp.553-561
    • /
    • 2016
  • The purpose of this study was to compare cardiopulmonary function, RPE(Rating of perceived exertion), and blood lactate when examining the GXT(Graded exercise testing) of wheelchair treadmill and arm ergometer. Participants were 11 wheelchair basketball players with non disability. While examining the GXT of wheelchair treadmill and arm ergometer, cardiorespiratory functional capacity was measured by using $Quarkb^2$ and Polar and RPE was measured through Borg Scale. The lactate analyser, YSI-2000 was used to measure blood lactate level when resting, right after exercise, two minutes, four minutes, six minutes, and ten minutes of recovery. Data was analyzed by paired t-test using SPSS 18.0 program and significance for all statistical analysis was fixed at .05 confidence level(p<0.05). The conclusion of this study is below. First, maximal oxygen uptake which is a factor of cardiopulmonary function showed the highest with arm ergometer, the rate of respiratory exchange showed the highest with wheelchair treadmill, and maximal heart rate showed the highest with wheelchair treadmill. Second, subjective exercise intensity showed the highest with arm ergometer at the end point. Third, blood lactate level showed the highest with arm ergometer right after exercise.

Effect of working time on the film thickness of dental resin cements (레진 시멘트의 혼합 후 시간에 따른 피막도의 변화)

  • Yi, Yu-Seung;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yeo, In-Sung;Ha, Seung-Ryong;Kim, Hee-Kyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.325-329
    • /
    • 2015
  • Purpose: The aim of this study was to compare the film thicknesses of several resin cements as a function of time after mixing and to examine the effect of working time on the film thicknesses. Materials and methods: The film thickness (${\mu}m$) of 4 resin cements (n=10), 1 composite resin (Panavia F 2.0), 3 self-adhesive resin (Clearfil SA luting, Zirconite, RelyX U200) cements was measured at 20-second intervals after mixing of the cements up to 200 seconds under a load of 50 N. Linear regression was fitted to verify the effect of working time on the film thickness of each cement. Data were compared to the working time recommended by manufacturers using Wilcoxon test ($\alpha$=.05). Results: All of the materials showed a positive linear correlation between the film thickness and working time. There was no statistically significant difference between the working time based on our results and the values recommended by the manufacturers even though there was a discrepancy between those two values. Conclusion: The film thickness of resin cements could increase with the increase of working time. Working time to meet the ISO standard of $50-{\mu}m$ maximum film thickness could be different from the manufacturer's recommended value.

A Study on the Effects of the Breath Efficiency & Lung Capacity Improvement Using Recorder Playing Focused on Breath Training (리코더 연주를 통한 뇌졸중 노력성 폐활량과 호흡 효율성 향상 연구)

  • Choi, Sung Joo
    • Journal of Music and Human Behavior
    • /
    • v.4 no.1
    • /
    • pp.31-46
    • /
    • 2007
  • The purpose of the study was to improve the efficiency of Breath & Forced Vital Capacity(FVC) of Stroke Patients Using Record Playing Focused on Breath Training. The Training of Forced Vital Capacity(FVC) is focused on trunk muscles reinforce for Breathing. So the study tried to play Recorder for reinforcing FVC. The play included the two parts. One was for solo play, the other was play in concert base on solo play using Korea country song, Arirang. The Recorder play used abdominal breath, Pursed-lip & Paced methods. The course of play included Long Tone, Staccato, Crescendo, Decrescendo and throughout the course we tried to improve the efficiency & Quantity of breathe. Experiment performed at Social welfare institute for the old. They played & checked FVC, $FEV_1$, $FEV_1/FVC$ before & after breathe 19 times for 6 weeks using Spirovit SP-1, Schiller. After experiment we performed statical process(p<0.05) using statical Package software. The findings were as follows: Analysis for Experiment showed the numerical Value of increasing Of FVC, $FEV_1$, $FEV_1/FVC$. Increasing Percentage of Measured/Predicted FVC, $FEV_1$ (or calculated based on theory) ration was 25%, 13% and Quantity of FVC, $FEV_1$ 35%, 40%. Also $FEV_1/FVC$ Ratio(showed efficiency of breathe) raised 13%. And experiment data was confirmed by statical process. The experiment data was valuable under p<0.05. In Conclusion we think the results of experiment showed the efficiency of Music therapy for Breathe(FVC, $FEV_1$, $FEV_1/FVC$) reinforce.

  • PDF

Study of External Radiation Expose Dose on Hands of Nuclear Medicine Workers (핵의학 종사자에서 손 부위의 외부 피폭선량 연구)

  • Park, Jun-Chul;Pyo, Sung-Jae
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.141-149
    • /
    • 2012
  • The aims of this study are to assess external radiation exposed doses of body and hands of nuclear medicine workers who handle radiation sources, and to measure radiation exposed doses of the hands induced by a whole body bone scan with high frequency and handling a radioactive sources like $^{99m}Tc$-HDP and $^{18}F$-FDG in the PET/CT examination. Skillful workers, who directly dispense and inject from radiation sources, were asked to wear a TLD on the chest and ring finger. Then, radiation exposed dose and duration exposed from daily radiation sources for each section were measured by using a pocket dosimeter for the accumulated external doses and the absorbed dose to the hands. In the survey of four medical institutions in Incheon Metropolitan City, only one of four institutions has a radiation dosimeter for local area like hands. Most of institutions uses radiation shielding devices for the purpose of protecting the body trunk, not local area. Even some institutions were revealed not to use such a shielding device. The exposed doses on the hands of nuclear medicine workers who directly handles radioactive sources were approximately twice as much as those on the body. The radiation exposure level for each section of the whole body bone scan with high frequency and that of the PET/CT examination showed that radiation doses were revealed in decreasing order of synthesis of radioactive medicine and installation to a dispensing container, dispensing, administering and transferring. Furthermore, there were statistically significant differences of radiation exposure doses of the hands before and after wearing a syringe shielder in administration of a radioactive sources. In this study, although it did not reach the permissible effective dose for nuclear medicine, the occupational workers were exposed by relatively higher dose level than the non-occupational workers. Therefore, the workers, who closely exposed to radioactive sources should be in compliance with safety management regulations, and take actions to maximally reduce locally exposed dose to hands monitoring with ring TLD.