• Title/Summary/Keyword: 토양전기전도도

Search Result 257, Processing Time 0.033 seconds

The Comparison of Electrical Conductivity for Soil Solutions Extracted in Field Capacity and Saturation-Paste (포장용수량과 포화 반죽 토양용액의 전기전도도 비교)

  • Lee, Ye-Jin;Lee, Jong-Sik;Yang, Jae-E.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.6
    • /
    • pp.776-781
    • /
    • 2010
  • Estimating the electrical conductivity of the saturation-paste (SP) is a common method to assess soil salinity. To assess soil salinity realistically, it is important to extract soil solution under field capacity. However, few studies on salinity assessment have been conducted for soil solution extracted under field capacity (-33 kPa; FC) moisture condition due to difficulty in soil solution extraction. This study was conducted to evaluate whether saturation-paste can represent field condition. Soil solutions were extracted from 22 soils in the plastic film house (PFH) and 18 soils in the reclaimed land (RL) at saturation and field capacity moisture conditions. Those were analyzed for pH, EC, cations ($K^+$, $Ca^{2+}$, $Mg^{2+}$, $Na^+$) and anions ($Cl^-$, ${NO_3}^-$, ${PO_4}^{3-}$, ${SO_4}^{2-}$). Both cations and anions of soil solution extracted from FC showed high correlations with ions extracted from SP in the PFH and the RL, except for ${NO_3}^-$, ${PO_4}^{3-}$ in the RL. Results of the t-test, the ECe and $EC_{FC}$ were not significant at significance level 0.05. The slopes of the equations between $EC_{FC}$ and ECe at more than sand 50% soils were higher than less than sand 50% soils, and differences of saturation percentage between SP and FC showed larger as increasing sand percentage. EC was related to soil water retention by soil texture. To determine the EC, soil texture and other soil properties which effect the soil moisture should be considered.

The Basic Study for Real-Time Measurement of Soil Electrical Conductivity in Paddy Field (part 1) (논 포장의 전기전도도 실시간 계측을 위한 기초적 연구 (1))

  • 박우풍;이충근;김상철;성제훈;정인규;황성준
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.73-78
    • /
    • 2002
  • 전기전도도 센서와 GPS장치를 연계하여 논 포장에서 실시간으로 전기전도도를 측정하는 기초시험을 실시하였다. 그 결과 아래와 같은 결과를 얻을 수 있었다. 가. 농기포장에서의 전기전도도의 평균값은 4.llmS/m인 반면, 같은 논 포장임에도 불구하고 호시포장에서는 평균값이 17.35mS/m를 나타내었다. 농기포장에서는 전기전도도의 변이계수가 34.66%, 호시포장에서는 13.15%로서 아주 큰 변이를 보였다. 나. 전기전도도 센서와 DGPS장치로부터 취득한 정보를 기반으로 지도를 작성할 수 있었다. Kriging 방법을 이용하여 지도를 작성함으로서 포장내·포장별 전기전도도 값의 공간변이가 존재함을 알 수 있었다. 다. 전기전도도 센서는 포장내·포장별 토양의 전기전도도를 측정하는데 문제점을 발견할 수 없었다. 그러나, 전기전도도 측정에 영향을 미치는 토양의 입자크기, 수분 함량 등의 영향을 고려한 좀 더 많은 연구가 진행되어야 할 것으로 판단되었다.

  • PDF

A Study of Soil Characteristics in Coastal Reclaimed Areas for Planting Ground Treatment (임해매립지에서 식재기반 조성을 위한 토양특성에 관한 연구)

  • 구본화;강재선;장관순
    • Korean Journal of Environment and Ecology
    • /
    • v.13 no.1
    • /
    • pp.89-95
    • /
    • 1999
  • 본 연구는 임해매립지에서 토양의 화학적 특성을 조사하여 수목식재를 위한 합리적인 토양관리에 관한 자료를 얻고자 수행하였다. 토양조사는 시화매립지의 시흥공단에서 녹지조성 예정지를 중심으로 토지이용별 및 토심별로 실시되었다. 조사지역에서 개흙은 전기전도도와 치환성나트륨 백분율이 높은 염류알칼리성 토양 특징을 갖고있었다. 임해매립지에서 토양 pH 평균값은 7.8~5.7범위이었고, 주거/공단 완충녹지 토양에서 전기전도도와 치환성나트륨 백분율은 각각 3.76Sm-1와 35%로 조사지역 중에 가장 높았다. 토양 50cm 깊이에서 치환성 Na+의 평균함량은 1.76~2.80cmol+/kg으로 조사되었고, 치환성 Na+의 평균함량은 치환성 Ca2+보다는 낮았으나 치환성 Mg2+과 K+보다는 높았다. 토심별 염분농도는 50cm보다 100cm 깊이에서 높게 조사되었으며, 주거/공단 완충녹지는 전토심에서 염분농도가 수목에 영향을 주기에 충분할 정도로 높았다.

  • PDF

Study on Characteristice of Transient Soulte Transport in the Vadose Zone by Using TDR: (1) Relationship between Water Content and Realtive Electrical Conductivity (TDR(Time Domain Reflectometry)를 이용한 비포화 토양에서 천이상태의 오염원 이송확산 특성에 관한 연구 : (1) 함수량과 상대전기전도도의 관계)

  • Park, Jae-Hyeon;Seo, Il-Won
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.6
    • /
    • pp.741-749
    • /
    • 1999
  • This study is to develop a method of measuring the soil water concentration by using TDR, which is based on the relationships between the bulk soil electrical conductivity of soil and the reflected wave of TDR. The proposed monitoring method is combined with two important relationships. One is that between the bulk soil electrical conductivity and the solute concentration, which is known to be linear at a constant volumetric soil water content and the other is that between the relative bulk soil electrical conductivity and the water content at a constant concentration. Some formulas have been proposed to solve the second relationship, but a new formula and the critical water content are proposed to improve the accuracy of measurement. This proposed formula estimates the relative bulk soil electrical conductivity for water contents which is divided to two regions, linear and nonlinear, by the critical water content. As the result of the comparison with other formulas, the proposed formula is proved to be superior to other formulas and to be an available method to apply to the unsaturated transient solute transport.

  • PDF

A Preliminary Conductivity Model Experiment for Determining Hydraulic Constants in Physical Model Borehole (시추공 수리전도도 상수를 결정하기 위한 전기전도도검층 기법을 이용한 예비모형실험)

  • 김영화;임헌태
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.1
    • /
    • pp.48-56
    • /
    • 2003
  • A geophysical conductivity logging technique has been adopted to determine hydraulic constants using a simplified physical model that depicts the borehole condition. An experiment has been made by monitoring the conductivity change within the model hole using borehole environment water and incoming-outgoing water of different salinity, under the state of constant flow rate by maintaining balance between inflow and outflow. Conductivity variation features were observed that depended on flow rate, salinity contrasts between fluid within the hole and incoming-outgoing fluid, and density contrasts between fluid conductivity within the hole and incoming fluid. The results of the experiment show the uniform change of fluid conductivity within the hole with time, a fairly good correlation between the flow rate and the conductivity change rate. The geophysical conductivity logging technique can be an efficient tool for determining hydraulic constants if the model equation is verified by henceforward experiments.

The Effect of Application Adjusted C/N Ratio of Orgaic Matter Resources on Soil Chemical Properties and Growth of Watermelon in Plastic Film Houses (시설재배지 유기물자원 C/N율 조절 시용시 토양화학성 및 수박의 생육에 미치는 영향)

  • Kang, Bo-Goo;Lim, Sang-Cheol;Lee, Joung-Won
    • Proceedings of the Korean Society of Organic Agriculture Conference
    • /
    • 2009.12a
    • /
    • pp.304-305
    • /
    • 2009
  • 시설재배지의 토양화학성 변화는 작물재배 기간 시비한 화학비료에서 유래된 무기성분 뿐만아니라, 가축분퇴비의 질소성분의 토양잔류량이 요소비료 보다 9.4배 많아 염류집적 주 요인이라는 보고('05 경기도)가 시사하는 봐와 같이 유기자원으로 시용하는 가축분 등의 부산물비료의 무기화에서 유래된 비료성분이 토양염류집적 및 토양환경악화에 더 큰 영향을 미칠 수 있다. 시설재배지의 유기물자원 시용기준이 토양의 특성에 관계 없이 작물에 따라 양적인 시험성적이 주로되어 있으며, 토양검정에 의한 시용기준도 유기물함량에 따라 볏짚, 우분, 돈분 및 계분으로 돠어 있다. 일반노지와 달리 시설재배지에서는 유기물함량이 토양의 비옥도 및 작물생육에 영향을 미치는 것 보다는 토양의 전기전도도(EC)가 더 중요한 작물생육 조건이 될 수 있다. 따라서 토양의 특성에 따라 물질순환에 의한 유기자원 시용기준으로 개선할 필요성이 있다. 시설재배지의 장기적인 토양관리를 위하여 유기물자원에 의한 토양환경 개선 효과를 구명하고자. 무처리, 가축분부산 물비료 관행 시용 기준 대비 볏짚 등 5개의 유기자원을 토양의 무기태질소 함량 대비 유기자원의 탄소함량을 C/N율 10 조절량을 시용하여 시험하였고, 또한 토양의 전기전도도(EC)가 상이한 3개( <2.0 dS/m, 2.0~6.0 dS/m, 6.0 dS/m<)토양에 유기물자원(우드칩)을 C/N율 10, 20, 30 조절하여 수박을 시험작물로 비닐하우스에서 재배하여 수행하였다. 시험 후 토양의 전기전도도(EC)는 시험 전에 비하여 시험 후 토양에서 가축분부산물비료는7% 증가되었으나 유기물자원 처리는 26~33% 경감되는 효과가 있었다. 수박의 과중은 무처리를 제외하고 처리간에 차이가 없었다. 유기물자원 C/N율 조절간에는 시험전 토양의 EC에 따라 차이가 있어 C/N 10 조절에서는 26~44%, C/N 20 조절에서는 30~51%, C/N 30 조절에서는 27~48% 경감효과가 있었으며, 3토양의 평균 토양EC 경감율은 C/N 10, 20, 30 조절에서 각각 34, 39 및 38 % 이었다. 수박의 생육 및 과중은 토양의 C/N율 조절간에는 차이가 없었으나, 토양의 EC 간에는 토양의 EC가 6.0dS/m 이상 토양에서 가장 낮았다. 따라서 탄소원의 유기자원을 C/N율 조절에 의한 시용기준 개선으로 토양의 무기태질소와 토양의 전기전도도(EC)를 경감시켜 친환경적 토양관리와 수박의 수량과 품질을 향상시킬 수 있을 것으로 평가되었다.

  • PDF

A study on the Measurement of Soil Water Concentration by Time Domain Reflectometry (TDR(Time Domain Reflectometry)을 이용한 토양수농도 측정에 관한 연구)

  • Park, Jae-Hyeon
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.2
    • /
    • pp.123-132
    • /
    • 1998
  • Monitoring solute transport has been known to be difficult especially for the unsaturated soil. The object of this study is to investigate the TDR application to monitoring solute concentration in the vadose zone. The TDR calibration test was conducted for soil samples with various water contents and concentrations. The voltage attenuation of electromagnetic wave of TDR was used to estimate the bulk electrical conductivity of a soil. The relationship between the bulk soil electrical conductivity and the solute concentration was assumed to be linear at a constant volumetric soil water content. In this study four proposed relationships were compared using data obtained from KCI solution at three different concentrations. Relationships given by Topp, Daltaon, Yanuka showed the linearity between the bulk soil electrical conductivity and the solute concentration, which were more pronounced than Zegelin's. The three relationships were found to be useful to measure the solute concentration in the vadose zone. In addition, TDR method was proven to be a viable technique in monitoring solute transport through unsaturated soils in transient flow condition.

  • PDF

Heating Characteristics of the Soils for the Application of Electrical Resistance Heating with Soil Vapor Extraction (전기 저항열을 이용한 유류 오염토 복원공정 적용을 위한 토양의 가열특성 연구)

  • Yun Yeo-Bog;Ko Seok-Oh;Park Gi-Ho;Park Min-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.1
    • /
    • pp.45-53
    • /
    • 2006
  • This study was performed to evaluate the heating characteristics of soils for the application of electrical resistance heating process combined with soil vapor extraction. Laboratory tests were conducted to find out optimum heating conditions by the adjustment of electrical supply and electrode. Results show that fine soil particles are more efficient for electrical heating. As water content of soil increases, more efficient electrical heating is observed. However, as the soil is saturated with water above the soil porosity, decrease in the heating efficiency is observed. The higher the voltage, is and the shorter the distance between the electrodes is, the better the heating efficiency is. The soil contaminated by fuel is also more efficient than non-contaminated soil in electrical resistance heating. From the relationship between the intial electrical current and the conductivity obtained in this study, soil temperature by electrical heating can be estimated.

매립장 주변 대수층 매질특성과 수질의 상관관계 연구

  • O In-Suk;Go Gyeong-Seok;Gu Min-Ho;An Ju-Seong
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.387-390
    • /
    • 2006
  • 매립장주변의 대수층 특성과 수리지화학적 특성과의 상관관계 분석은 매립장 환경 위해 요인을 평가하는데 중요한 역할을 하며 이를 위해 생활쓰레기 매립장인 금산 매립장을 대상으로 연구를 수행하였다. 대수층 매질 특성을 파악하기 위해 토양시료를 채취하여 중금속 성분 및 pH, 전기전도도, 용존유기탄소, 양이온교환능력, 유기물함량, 토양 입도분석을 수행하였고, 수리지화학적 특성 파악을 위해 수질검층 및 지하수 시료를 분석하여 매립지역의 수직 및 수평적인 분포 특성을 파악하였다. 대수층의 토양특성과 지하수 수질특성의 비교분석 결과 침출수 집수정을 기점으로 침출수의 영향을 받은 관측정의 전기전도도(EC) 측정값이 배경 지하수에 비해 상대적으로 높은 값을 보여 주었다. 입도분석 결과 상부 표토에 가까운 50cm 이내의 토양은 농경의 영향으로 심부보다 상대적으로 실트질 토양이 많고 이보다. 심부의 토양은 사질 토양으로 되어 있었다. 이러한 투수성이 좋은 사질 토양은 지하수의 이동을 비교적 쉽게 유도하기 때문에 매립장으로부터 침출수가 누출되었을 때 지하수 흐름을 따라 빠르게 이동할 수 있는 통로로 작용될 것으로 판단된다.

  • PDF