• Title/Summary/Keyword: 토양오염지도

Search Result 39, Processing Time 0.039 seconds

Construction of Three Dimensional Soil Cadmium Pollution Map Using Geotechnical Information DB System (국토지반정보시스템을 이용한 3차원 토양오염지도 구축)

  • Hwang, Dae Young;Kang, In Joon;Jang, Yong Gu;Kim, Soo Kyum
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.4
    • /
    • pp.13-19
    • /
    • 2016
  • This study presented the build-up of three-dimensional soil pollution map for precise analysis. To do this, survey on the existing pollutant region on Dongnae-gu, Busan that is the study subject, showed that it tended to produce 0.72 clusters. So, this study suggested to investigate center of $1km{\times}1km $ grid and, as the results of comparing the pollution map that input pollution figure values based on the actually investigation point showed precise results. And, it divided the standard of pollution into 5 levels in surface and underground space and the map was built up using IDW interpolation against the amount of polluted substance. The pollution of ground surface, flow of polluted substance, coefficient of permeability and ground water level that are 504 geotechnical informations were selected as the influential parameters in pollution analysis of underground space, and it calculated that to 0~20 points by dividing the characteristics. It enables the build-up of pollution map of ground surface-underground with depth that considers the characteristics of soil layers and it is considered that it is possible to analyze the general infiltration. And, it was considered that it enables more accurate forecast about influential analysis per depth and pollution of underground water.

토양 정밀 조사에 의한 폐광산 주변 토양의 오염 부지 특성 규명

  • 차종철;이정산;이민희;최정찬;김진원
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.346-349
    • /
    • 2003
  • 광산 및 폐광산으로부터의 오염 및 유해영향에 대한 보고와 관심이 대두되면서 휴ㆍ폐광산에 대한 연구가 활발히 진행되고 있다. 본 연구는 경북 군위군의 고로 폐광산 주변 중 광미 및 광폐석으로 오염된 것으로 생각되어지는 하천 및 농경지에 대한 오염 정도와 분포를 규명하기 위하여 토양정밀조사를 실시하였다. 토양 오염 정밀조사 지침에 따라 총 741개의 토양 시료 분석 결과 Cu, Cd, Pb은 토양오염 우려 기준에 훨씬 미치지 못하였지만 As는 표토 및 심토 구간(0-30cm)에서 토양 오염 우려 기준 농도를 상당 수 초과하여 하천 및 농경지의 복원이 필수적임을 알 수 있었다. 합리적인 복원물량을 산출하기 위하여 배경치 농도(1.23mg/kg), 토양오염우려기준 40%농도(2.4mg/kg), 토양오염우려기준농도(6mg/kg), 토양오염대책기준농도(15mg/kg)별로 오염 등급을 나누어 오염 지도를 작성하고 각 등급별 복원목표에 따라 복원이 필요한 면적과 복원대상물량을 산출하였다. 본 연구는 오염토양의 복원을 목적으로 국내에서 최초로 실시된 대규모의 토양정밀조사라는 점에서 의미가 있으며, 이 결과는 실제 고로 폐광산지역의 복원 사업설계에 중요한 자료로 사용될 수 있다.

  • PDF

Optimization of Soil Contamination Distribution Prediction Error using Geostatistical Technique and Interpretation of Contributory Factor Based on Machine Learning Algorithm (지구통계 기법을 이용한 토양오염 분포 예측 오차 최적화 및 머신러닝 알고리즘 기반의 영향인자 해석)

  • Hosang Han;Jangwon Suh;Yosoon Choi
    • Economic and Environmental Geology
    • /
    • v.56 no.3
    • /
    • pp.331-341
    • /
    • 2023
  • When creating a soil contamination map using geostatistical techniques, there are various sources that can affect prediction errors. In this study, a grid-based soil contamination map was created from the sampling data of heavy metal concentrations in soil in abandoned mine areas using Ordinary Kriging. Five factors that were judged to affect the prediction error of the soil contamination map were selected, and the variation of the root mean squared error (RMSE) between the predicted value and the actual value was analyzed based on the Leave-one-out technique. Then, using a machine learning algorithm, derived the top three factors affecting the RMSE. As a result, it was analyzed that Variogram Model, Minimum Neighbors, and Anisotropy factors have the largest impact on RMSE in the Standard interpolation. For the variogram models, the Spherical model showed the lowest RMSE, while the Minimum Neighbors had the lowest value at 3 and then increased as the value increased. In the case of Anisotropy, it was found to be more appropriate not to consider anisotropy. In this study, through the combined use of geostatistics and machine learning, it was possible to create a highly reliable soil contamination map at the local scale, and to identify which factors have a significant impact when interpolating a small amount of soil heavy metal data.

A Study on the Soil Contamination(Maps) Using the Handheld XRF and GIS in Abandoned Mining Areas (휴대용 XRF와 GIS를 이용한 폐광산 지역의 토양오염에 관한 연구)

  • Lee, Hyeon-Gyu;Choi, Yo-Soon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.3
    • /
    • pp.195-206
    • /
    • 2014
  • In this study, soil contamination maps related to Cu and Pb were created at the Busan abandoned mine in Korea using a handheld X-Ray Fluorescence(XRF) and Geographic Information Systems(GIS). Hydrological analysis was performed using the Digital Elevation Model(DEM) of the study area to identify the flow directions of surface runoff where pollutants can be dispersed from the soil contamination sources. 24 locations for measuring the soil contamination related to Cu and Pb were selected by considering the result of hydrological analysis. The results measured at the 24 locations using the handheld XRF showed that the highest value of Cu contamination is 8,255ppm and that of Pb is 2,146ppm. The field investigation data were entered into ArcGIS software, and then soil contamination maps regarding Cu and Pb with a 5m grid-spacing were created after performing spatial interpolations using the ordinary kriging method. As a result, we could know that high concentrations of Cu and Pb are presented at the waste and tailings dumps around the abandoned mine openings. This study also showed that the handheld XRF and GIS can be utilized to create soil contamination maps related to Cu and Pb in the field.

Contaminant Release from and Oxygen Uptake Rate of Landfill Soils of Different Age (비위생매립지 토양의 매립종료기간에 따른 오염특성 및 산소소비율 평가)

  • 신언빈;김종호;배우근
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.57-60
    • /
    • 2001
  • 미생물 활성도와 그에 따른 유기물의 분해율은 미생물의 호흡률과 직접적인 관계가 있다. 본 연구는 매립종료후 경과기간이 1년인 Y 매립지와 10년인 C 매립지의 오염특성을 조사하였고, 오염토양 미생물의 산소소비속도를 이용하여 매립종료기간에 따른 오염토양의 산소소비율을 비교 평가 하고자 하였다. C 매립지의 오염토양에 대한 SCO $D_{cr}$ TOC는 Y 매립지에 비해 낮은 함량으로 나타났으나 T-N, N $H_3$-N의 함량은 큰 차이를 보이지 않았다. TOC/T-N비로 보았을 때 Y 매립지에 비해 C 매립지가 낮은 것으로 나타나 연령이 많은 경우 분해성 유기물의 함량은 적은 것으로 판단된다. 산소소비율 실험결과 Y 매립지가 산소소비율이 높은 것으로 나타났으며, C 매립지도 대조토양에 비해 높은 산소소비율을 보였다. 따라서 매립종료 후 경과기간이 10년인 매립지의 미생물의 산소소비율을 보았을 때 여전히 생물학적 안정화가 종료되지 않은 것을 알 수 있었다.

  • PDF

Remediation Design Using Soil Washing and Soil Improvement Method for As Contaminated Soils and Stream Deposits Around an Abandoned Mine (토양 세척법과 석회를 첨가한 토양 안정화 공법을 이용한 폐광산 주변 비소 오염 토양 및 하천 퇴적토 복원)

  • 이민희;이정산;차종철;최정찬;이정민
    • Economic and Environmental Geology
    • /
    • v.37 no.1
    • /
    • pp.121-131
    • /
    • 2004
  • Removal efficiencies of soil washing and soil improvement processes to remediate farmland soils and stream deposits around Goro abandoned mine were investigated with batch and column experiments. For As-contaminated farm-land soils around Goro mine, batch tests to quantify As extraction rate from contaminated soils and lime treated contaminated soils were performed. The contaminated soil mixed with lime decreased As extraction rate less than one fourth, suggesting that the soil improvement method mixed with lime dramatically decrease As extraction rate. A storage dam will be constructed in the lower part of the main stream connected to Goro abandoned mine and the amount of As extracted from the bottom soils of reservoir could be the main source to contaminate water of reservoir. The decrease of As extraction amount from the bottom in reservoir, caused by the application of the soil improvement method was investigated from the physically simulated column experiment and results showed that As extraction rate decreased to one forty when 1% lime mixed soil improvement was applied to contaminated soils. For contaminated stream deposits connected Goro mine, the removal efficiency of the soil washing method was investigated with batch experiments. Hydrochloric acid, citric acid, acetic acid and distilled water were used as soil washing solution and 0.01, 0.05, 0.1, 0.5, 1.0 N of washing solution were applied to extract As. When washing with 0.05 N of hydrochloric acid or citric acid, more than 99.9% of As was removed from stream deposits, suggesting that As contaminated stream deposits around Goro mine be successfully remediated with the soil washing process. Total volumes of contaminated soils and deposits needed for remediation were calculated based on three different reme-diation target concentrations and the operation cost of soil washing for calculated soil volumes was estimated. Results from this research could be directly used to make a comprehensive countermeasure to remediate contaminated area around Goro mine and also many contaminated areas similar to this research area.

Environmental Assessment and Decision of Remediation Scope for Arsenic Contaminated Farmland Soils and River Deposits Around Goro Abandoned Mine, Korea (토양 정밀 조사에 의한 고로폐광산 주변 비소오염 토양 및 하천퇴적토의 오염도 평가 및 오염 토양 복원 규모 설정)

  • 차종철;이정산;이민희
    • Economic and Environmental Geology
    • /
    • v.36 no.6
    • /
    • pp.457-467
    • /
    • 2003
  • Soil Precise Investigation(SPI) for river deposits and farmland soils around Goro abandoned Zn-mine, Korea was performed to assess the pollution level of heavy metals(As. Pb, Cd, Cu) and to estimate the remediation volume for contaminated soils. Total investigation area was about 950000 $m^2$, which was divided into each section of 1500 $m^2$ corresponding to one sampling site and 545 samples for surface soil(0-10cm in depth) and 192 samples for deep soil(10-30cm in depth) from the investigation area were collected for analysis. Concentrations of Cu, Cd, Pb at all sample sites were shown to be lower than Soil Pollution Warning Limit(SPWL). For arsenic concentration, in surface soils, 20.5% of sample sites(104 sites) were over SPWL(6mg/kg) and 6.7%(34 sites) were over Soil Pollution Counterplan Limit(SPCL: 15mg/kg) suggesting that surface soils were broadly contaminated by As. For deep soils, 10.4% of sample sites(18 sites) were over SPWL and 0.6%(1 site) were over SPCL. Four pollution grades for sample locations were prescribed by the Law of Soil Environmental Preservation and Pollution Index(PI) for each soil sample was decided according to pollution grades(over 15.0 mg/kg, 6.00-15.00 mg/kg, 2.40-6.00 mg/kg, 1.23-6.00 mg/kg). The pollution contour map around Goro mine based on PI results was finally created to calculate the contaminated area and the remediation volume for contaminated soils. Remediation area with over SPWL concentration was about 0.3% of total area between Goro mine and a projected storage dam and 0.9% of total area was over 40% of SPWL. If the remediation target concentration was determined to over background level concentration, 1.1% of total area should be treated for remediation. Total soil volume to be treated for remediation was estimated on the assumption that the thickness of contaminated soil was 30cm. Soil volume to be remediated based on the excess of SPWL was estimated at 79,200$m^3$, soil volume exceeding 40% of SPWL was about 233,700 $m^3$, and soil volume exceeding the background level(1.23 mg/kg) was 290,760 TEX>$m^3$.

Quantitative Analysis of River Pollution Based River Quality Visualization Service (하천의 오염물질 정량 분석을 기반으로한 환경오염도 시각화 서비스)

  • Lee, Su-Hyung;Lee, Sun-Hyung;Park, Young-Ho;Kim, Kyung-Ho;Pyeon, Mu-Wook
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2011.05a
    • /
    • pp.397-398
    • /
    • 2011
  • 산업의 고도화로 인한 환경오염과 하천공간의 이용이 증가함에 따라 하천 상태에 대한 관심이 높아졌다. 그러나 하천의 상태에 대한 정보를 쉽고, 정확하게 찾아 볼 수 있는 콘텐츠가 부족하다. 본 논문은 U-City에서의 쾌적한 도시환경을 위한 서비스의 일환으로 하천 주변 환경의 오염에 대한 정보를 제공할 수있다. 하천의 구간별 하천수와 하천토양의 오염도를 측정하여, 수질환경기준에 따른 수질분석 결과를 시각화한다. 시각화는 전체 수질 및 토양에 관한 시각화와 각 오염물질의 변화량을 동시에 3차원으로 시각화하여, 직관적이고 정확한 정보를 제공받을 수 있다. 또한 인터넷 포털사이트의 지도 서비스와 연계하여 사용자들의 접근성을 높일 수 있다.

  • PDF

Analysis of Non-point Source Pollution using GIS Technique (GIS를 이용한 충주호주변의 비점원 오염 분석 연구)

  • 김윤종;유일현;김원영;류주영;이영훈;민경덕
    • Spatial Information Research
    • /
    • v.3 no.1
    • /
    • pp.1-18
    • /
    • 1995
  • Despite the widespread use of GIS over the past ten years, it has been limited application for regional modeling of pollutant loadings such as sediment, nitrogen, and phosphorus(non-point source pollution), The goals of this study were to: select important processes and parameters of watersheds that contribute to non-point source pollution degradation, develop a ranking model to use the environmental geologic data and verify the model by comparing results with existing water quality data(Chung-ju Lake) for specific watersheds, The GIS database consisted of topography, geology, soils, precipitation, rainfall erosivity, land use, and watershed boundaries. The index(NPSP) for assessing non-point source pollution was comprised in the following three seperate components: soil loss index(SLI) assesses the potential soil erosion and sedim-ent delivery from field to stream; run-off potential ratio(R.P.R) predicts the potential production of surface runoff; chloropgyll-a index ranks the potential manure(animal or human) production within a watershed. The GIS model was a valuable tool to assess the impact of environmental pollation in watersheds.

  • PDF

Evaluation of Soil Flushing Column Test for Oil-contaminated Soil Treatment (유류오염토양 처리를 위한 컬럼식 토양세정기술 평가)

  • Kang, Hui-Cheon;Han, Byeong-Gi;Kim, Joung-Dae;Seo, Seung-Won;Shin, Chul-Ho;Park, Joon-Seok
    • Clean Technology
    • /
    • v.23 no.3
    • /
    • pp.302-307
    • /
    • 2017
  • This study was conducted to evaluate the feasibility of in situ soil flushing for TPH-contaminated soil remediation with column test. The soil texture of the soil was sand and the initial TPH concentration was $9,369mg\; kg^{-1}$. 0.1% Tween-80 was selected as surfactant solution. And the acrylic and the glass syringe columns were used as reactors. In the acrylic column test, 35% of the initial TPH was removed in 1 PV of flushing and approximately 40% in 5 PV and finally 7 PV showed about 60%. The glass column test showed 3 ~ 12% higher removal efficiency than that of acrylic test until 5 PV of flushing. However, there was no difference in TPH removal efficiency when 7 PV of surfactant was finally flushed. Both of alum only and alum+polymer mixed surfactants showed also the best coagulation efficiency in $150mg\;L^{-1}$ of concentraion. When Tween 80 was newly dissolved in 0.1% to the recovered solution after the coagulation treatment, the removal efficiency was increased from 32.0% to 41.0% in comparison to the new 0.1% Tween 80 solution without reuse by coagulation treatment.