• Title/Summary/Keyword: 토양매립

Search Result 336, Processing Time 0.032 seconds

A Case History of Confinement of the Contaminated Landfill Using a Vortical Barrier (연직 차수벽을 이용한 폐기물매립지 침출수 오염 제어 사례 연구)

  • 이재영;정문경;고재만
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.2
    • /
    • pp.163-174
    • /
    • 1999
  • This paper presents a case history of remedial action adopted for contaminated groundwater in a landfill. The objectives of the projects are : (1) to effectively confine contaminated groundwater with an economically reasonable means, (2) to prevent further contamination of soil by collecting and treat the contaminant. and (3) to assure the environmental safety of the landfill during its operating period. Reported are the process from site investigation, through design and construction of an appropriate remedial action, to the monitoring of the selected confinement system. In view of the results of site investigation, deep soil mixing cutoff wall using the DMW(deep soil mixing cutoff wall) method and specially produced HEC soil stabilizer were used for the construction of deep soil mixing cutoff wall. For rock foundation with sever fractures, chemical grout curtain with urethane was installed. The monitoring results to date indicate that the selected vertical barrier performed satisfactorily.

  • PDF

도시 고형폐기물의 열분해용융 특성

  • 이협희
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.31 no.9
    • /
    • pp.16-23
    • /
    • 2002
  • 현재 우리나라는 1980년대 후반부터 도시폐기물 소각시설을 설치하기 시작하여 전국적으로 20 여곳의 대형 소각장이 가동되고 있으며 대기오염 방지 기술도 발전에 발전을 거듭하여 불과 10 여년 동안에 선진국 수준의 대기오염 배출기준을 만족하는데 아무 문제가 없을 정도로 되었다. 그러나 소각후 발생 하는 소각재의 경우 비산재는 고형화등의 처리 후 매립하고 바닥재는 별도 처리없이 매립하는 실정이어서 매립 후 시간이 흐를수록 매립된 소각재에서 용출되는 다이옥신과 소각재 중에 포함된 중금속 등에 의한 토양오염과 수질오염의 우려가 남아 있는 것이 사실이다. 소각후 남는 소각재는 폐기물량의 약 15 %, 비산재는 약 1.5 % 정도 발생하는 것으로 볼 때 매립은, 특히 다음 세대에 유산으로 남겨진다는 점에서 더 이상 적절하지 않은 해결책으로 생각되며 유럽과 일본 등 선진국에서는 이미 이와 같은 소각재에 대한 무해화 처리기술이 개발되고 속속 상용화되고 있으므로 우리나라도 하루빨리 열분해용융시설등 신기술을 개발하거나 도입하여 세계적 환경 기술경쟁 에서 선진국과 어깨를 나란히 함은 물론 청정한 국토를 후손에게 물려줄 수 있도록 하는 대책이 강구되어 야 할 것이다. 본 고에서는 폐기물 처리기술의 세계 적 동향을 살펴보고 폐기물의 완전 자원화에 성공한 대우 써모셀렉트 열분해용융 기술의 특성에 대해 소개하고자 한다.

  • PDF

A Study on the Structure Characteristics of Planting Ground in Incheon International Airport, Korea (인천국제공항 식재기반 구조 및 토양특성 연구)

  • Lee, Seung-Won;Han, Bong-Ho;Lee, Kyong-Jae;Kwak, Jeong-In;Yeum, Jung-Hun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.3
    • /
    • pp.77-91
    • /
    • 2015
  • This study aims to suggest adequate soil management through the analysis of physicochemical properties of soil in the planting grounds of Incheon International Airport, which was constructed on a massive land reclamation site. Study areas were 5 sites at the international business complex, the passenger terminal, the airport support complex, the free trade zone, and the access road. Soil profile analysis showed that 9 plots out of the 27 plots were hardpan and heterospere within 80cm from the soil surface. The earth laid on the ground was categorized as gravel based soil(4 plots), dredged soil from the sea bottom and mixed reclamation materials(2 plots), clay with poor permeability(3 plots) and waste construction material(1 plot). Average soil hardness was $11.5kg/cm^2$ and soil textures were sandy soil, sandy loam and loamy sand. Average soil pH was 6.7 and average organic matter content was 0.7%. Electrical conductivity was 0.0dS/m and exchangeable cation concentrations were $Ca^{2+}$ 3.4cmol/kg, $Mg^{2+}$ 1.5cmol/kg, $K^+$ 0.3cmol/kg and $Na^+$ 1.0cmol/kg. Average cation exchange capacity was 11.0cmol/kg. Although average figures in Solum mostly meet the landscape design criteria, properties of each soil layer showed various values sometimes over the limit. Base saturations were $Ca^{2+}$ 29.9%, $Mg^{2+}$ 13.3% and $K^+$ 3.7% for lower soil, $Ca^{2+}$ 33.3%, $Mg^{2+}$ 17.0% and $K^+$ 2.7% for mid-soil and $Ca^{2+}$ 32.6%, $Mg^{2+}$ 12.2% and $K^+$ 1.9% for upper soil. Exchangeable sodium percentages were 16.4% for lower soil, 7.5% for mid-soil and 4.7% upper soil. Sodium adsorption rates were 0.8 for lower soil, 0.3 for mid-soil and 0.2 for upper soil. Factors affecting to the vegetation growth were heterogeneity and poorness of solum, disturbance of dredged soils, high soil hardness including hardpan in the subsurface soil layer and shallow effective soil depth, high soil acidity, imbalance of base contents, low organic matter content and low available phosphate levels in the soil.

Steelers' Dust-catalyzed Oxidative Treatment of Landfill Leachate (제강분진을 이용한 매립지 침출수의 산화처리)

  • 강정우;김성용;장윤영;배범한;장윤석
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.1
    • /
    • pp.25-31
    • /
    • 2002
  • This study attempts to elucidate the possibility of treating landfill leachate by steelers' dust/${H_2}{O_2}$ system in a well-mixed batch reactor. Experiments were conducted to investigate the effects of operating variables such as pH, dust and ${H_2}{O_2}$ dosages and ${H_2}{O_2}$ injection method on the treatment efficiency, Contaminant concentrations were identified by TOC (Total Organic Carbon) analyzer. Experimental observations showed the possibility of steelers' dust as a catalytic reagent in the ${H_2}{O_2}$/dust system. The batch experiments showed that the optimal $H_2O$$_2$ and dust dosage, 20g/L dust. 2,000mg/L ${H_2}{O_2}$ removed about 75% of initial TOC concentration (250mg/1) within 60 min. And the TOC removal in the ${H_2}{O_2}$/dust system effectively proceeded only within a limited pH range of 3-4. The stealers' dust-catalyzed oxidative treatment of landfill leachate was more efficient compared with the $FeSO_2$catalyzed system (Fenton oxidation) for the removal rate and the cost.

Development of the log cultivation techniques of the maitake Grifola frondosa (잎새버섯(Grifola frondosa) 원목재배 기술 개발)

  • Lee, Jae-Hong;Lee, Nam-Gil;Park, Young-Hak;Mun, Youn-Gi;Jeong, Tae-Sung;Kwon, Sun-Bae;Kim, Jae-Rok;Yoo, Young-Bok
    • Journal of Mushroom
    • /
    • v.11 no.4
    • /
    • pp.240-243
    • /
    • 2013
  • This study was conducted to develop the log cultivation techniques of the maitake Grifola frondosa. We used two kinds of Grifola frondosa strains for this study. Fully incubated logs were buried into soil directly and were buried with soil inside of container box in 70% shaded vinyl house. In the vinyl house Yipsaeilho cultivar buried by the soil was delayed about 15days in harvest date compared with Dabak cultivar. Color of fruit body of Yipsaeilho cultivar was dark brown and that of Dabak cultivar was grayish brown. Yields of Yipsaeilho cultivar was 15-16 $kg/m^2$, more than that of Dabak cultivar, 11-13 $kg/m^2$. In the container box, Yipsaeilho cultivar buried by the soil was also delayed about 5days in harvest date compared with Dabak cultivar. Color of fruit body was similar to the result of vinyl house soil reclamation. But yields difference was not shown between two cultivars, 1.2-1.4 kg/box.

Soil Contamination Analysis and its Treatment for Landfilled Area (폐기물 매립지반 오염도 분석 및 처리방안에 대한 연구)

  • Shin, Eun-Chul;Kang, Jeong-Ku;Jang, Woo-Lam
    • Journal of the Korean Geosynthetics Society
    • /
    • v.8 no.2
    • /
    • pp.1-9
    • /
    • 2009
  • When some structures are constructed over the sanitary landfill, the waste should be treated by means of replacement and other ways. Otherwise, various problems like a ground contamination, settlement, reduction of bearing capacity and others may be generated. To find out the optimal method of treatment, the properties of the ground have to be inspected. In this study, the preliminary investigation was conducted to find out the characteristic of this site which is considered as insanitary waste landfill. Furthermore, the shape and the amount of the waste was investigated by subsurface investigation like a boring and sampling methods. In addition, the degree of ground contamination and disposal method of refuse was examined.

  • PDF

Hydraulic Properties of a Coastal Waste Dump in Pohang, Southeastern Korea (포항 지역 해안 투기 매립장의 수리 특성에 관한 연구)

  • 김윤영;강동근;이강근
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.3 no.1
    • /
    • pp.1-8
    • /
    • 1996
  • Coastal waste dump in Pohang is composed of slags and sludge of POSCO. Hydraulic parameters in the coastal waste dump are very different from those in municipal landfills and general unconsolidated or fractured aquifers. In the waste dump pumping or slug tests are not adequate for the estimation of hydraulic parameters. Time-lag and amplitude of the tidal fluctuation of groundwater table are used to determine the hydraulic parameters. Groundwater table at the groundwater observation wells is about 40 cm higher than the sea level. The contributing factors of the groundwater-rise are estimated. Vertical profile of some chemical constituents in groundwater indicates the gradual transition of the fresh groundwater at the uppermost position to the sea water at the bottom.

  • PDF

Analysis of Flow Character and Gas Measurement from Final Cover Soil of sanitary Landfill (쓰레기 매립지 최종 복토층에서 가스 측정방법과 유출특성 해석)

  • 이해승
    • Journal of Korea Soil Environment Society
    • /
    • v.3 no.3
    • /
    • pp.75-86
    • /
    • 1998
  • This paper is going to show the way we can sample the landfill gases flowing out to the air through final cover soil by using an closed chamber in the field for a short time. In addition, we came to the following results through the application of model with actual measurements. 1) Analyzing changes of concentration in the chamber(H: 10-30cm) every 5 minutes, considering analysis time of gas chromatograph for an half hour. 2) The proportion of $CE_4$to $CO_2$changes rapidly near the surface of final cover soil by the influence of methane oxidation reaction. 3) When flux of landfill gas is F=$10^{-5}$mol/$\textrm{m}^2$.s), methane oxidation reaction has an influence on composition of gases, however there is little influence when F=$10^{-6}$ mol/($\textrm{m}^2$.s).

  • PDF