• Title/Summary/Keyword: 토양매립

Search Result 336, Processing Time 0.027 seconds

Analysis by Environmental Factor of Similar Closed Non-sanitary Landfills (사용종료된 유사비위생 매립지들의 환경인자 분석)

  • Lee, Byungchan;Lee, Minhee;Park, Sangchan;Jeong, Seonki;Han, Yangsu;Yeon, Ikjun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.6
    • /
    • pp.27-33
    • /
    • 2009
  • In this study, it was analysed physical characteristics, TS, moisture, C/N ratio, leaching test, and element analysis in landfill wastes of 10 years old without landfill pretreatment. The Organic material content was 7.2%~23.5% and soil was the main inorganic materials which it's rate was 54.1%~71.0%, in landfill wastes. The results of TS, VS, and moisture were represented 51.5%~68.1%, 23.6%~56.1%, 32.0%~48.4%, respectively. The analysis of hazardous materials did not indicate Hg, $Cr^{+6}$, CN, Organic Phosphorus, TCE and PCE, however the Pb of leaching materials showed 0.023~0.092 mg/L, which was the highest. As the result of the element analysis, C was 47.74%~56.72%, N was 4.09%~9.92%, the C/N ratio was 5.76~12.57 and the result of soils around landfill was the highest heavy material, Pb, 2.465 mg/kg~10.251 mg/kg. The objectives of this paper are to investigate states, stabilization of these closed landfills and to gain suitable data for post-closure care using some parameters through analysis of landfill environment.

  • PDF

The Numerical Modeling Study for the Simultaneous Flow of Leachate and LFG in Kimpo Landfill (수도권 매립지에서 침출수-가스의 동시 유동 해석을 위한 전산 모델링 연구)

  • 성원모;박용찬;이광희
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.6 no.2
    • /
    • pp.101-106
    • /
    • 1999
  • Open dump of refuse causes groundwater and soil contamination by leachate and air pollution by LFG(Landfill Gas). In this paper, in order to perform a study about reduction of high leachate and LFG collection & control, using a 3-D, 2-phase, transient FDM model, the analysis of simultaneous flow of leachate and LFG has been carried out. In present numerical analysis it is assumed that 58 percents of LFG will evaporate to the ambient air and the recharge rate of a landfill be 12 percent of the average precipitation per year. All other data were excerpted at the point of 1995 when three refuse layers had been buried. From numerical analysis we concluded that maximum head value is approximately 26 mH2O<-에이치투오 (2.52 atm) in the center of the system and that installing venting trench plays an important role in landfill stabilization. Evan with the assumption of three layers constructed and low recharge rate applied, it is found that cumulative leachate and LFG productions will be 15.1 million 세제곱미터, 5.58 billion 세제곱미터, respectively after 40 years.

  • PDF

Case Study on the Investigation of Leachate Contamination from Waste Landfill Using Electromagnetic and Magnetic Methods (쓰레기 매립장 주변의 침출수 오염조사 사례: 전자탐사 및 자력탐사의 적용)

  • Son Jeong-Sul;Kim Jung-Ho;Yi Myeong-Jong;Ko Kyung-Seok
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.2
    • /
    • pp.137-144
    • /
    • 2005
  • In this study, we offered the results of geophysical and geochemical survey on the municipal waste disposal area to delineate the size and extent of leachate contamination. Preliminary to intensive geochemical investigation, we performed two geophysical methods to characterize the survey area. Electromagnetic (EM) and magnetic method were used far site investigation. From the EM method, we can get the information of soil conductivity directly related to the leachate of the contaminations and from magnetic anomalies we can find the boundary of landfill which is not identified on the surface due to soil capping. The results of geophysical survey were well matched to those of geochemical method carried out inside and near the landfill. Electric conductivity (EC) of the groundwater sampled from low resistivity anomaly region of EM result was higher than background value and the border estimated from the magnetic survey showed good agreement with that estimated from the soil gas detection survey.

A Study of Landfill Coyer Liners by Freezing/Thawing (동결/융해에 따른 폐기물 매립지 복토층 연구)

  • Jai-Young Lee
    • Journal of Korea Soil Environment Society
    • /
    • v.1 no.1
    • /
    • pp.103-109
    • /
    • 1996
  • The cover liners at municipal and hazardous waste landfill is not emphasized as much as the bottom liners. However, one of the most effective reason of landfill destroy is the cover liner failure. The cover system at municipal and hazardous waste landfill, 1 perform the following functions, at minimum: promote surface runoff, impede infiltration, protect settlement in the landfill, and provide a buffer from surface exposure of the waste. This research was to expand the existing knowledge base of landfill cover liner behavior during period of freeze/thaw Also, the great Lysimeter was built in the laboratory to provide as much as same condition with the field and three designs were simulated by actual cover materials. The result of simulation indicated the clay was effected by freezing/thawing. The degradation of cover liners in the frost penetration affects the physical, engineering properties of clay. these factors may consider to design and construct of the landfill. This paper provides the description of testing cover liners, experimental results and a discussion of the results of the simulation.

  • PDF

A study on the hydraulic characteristics of the geosynthetic clay liners(GCL) with humic substances of leachate on the landfill. (폐기물 매립지의 침출수의 휴믹물질에 의한 토목합성수지 점토라이너의 수리학적 특성에 관한 연구)

  • 한영수;이재영
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.1
    • /
    • pp.33-40
    • /
    • 2002
  • The study was performed to evaluate the effect of landfill leachate on the hydraulic conductivity of Geosynthetic Clay Liner (GCL) with two types of leachate. GCL used in waste landfills have a significant ability as a barrier material, however, they also have a potential danger when exposed to some organic and inorganic leachate as well as humic materials. In this study, swelling tests and hydraulic conductivity tests were performed to evaluate the effect of humic materials and landfill leachate on the hydraulic characteristics of the GCL. The result of swelling tests showed that the amount of humic materials and high electronic conductivity caused a decrease of the swelling of bentonite. This is expected to increase the hydraulic conductivity of GCL. The increasing of hydraulic conductivity observed for GCL permeated with 0-leachate was significantly higher than that of Y-leachate. This result shows that humic materials are obviously affecting with the increasing of hydraulic conductivity of GCL.

Development of Amended Clay Liner for Waste Containment System (매립장의 인공점토차수재 개발에 관한 연구)

  • 신은철;김성환;오영인
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1997.05a
    • /
    • pp.70-73
    • /
    • 1997
  • Recycling of$\boxUl$ useful industrial waste is highly recommended by the government. Some geotechnical properties such as specific gravity, dry density, unconfined compressive strength, pH. compressibility, permeability were determined to evaluate the feasibility of waste lime use in the landfill as an admixture clay liner. Various types of environmental tests on waste lime were conducted to compare the results with the EPA requirements. Laboratory test results indicate that admixture soil(waste lime/decomposed granite soil) is a promising material its an admixture clay liner in the sanitary landfill.

  • PDF

도시 폐기물 매립지반의 내진해석

  • 최진욱;장연수
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.281-285
    • /
    • 2004
  • 폐기물 매립시설물은 지진에 의해 파괴될 경우 시설물 파괴로부터 인명 및 경제적인 피해와 더불어 복구하기 어려운 환경적인 문제가 발생한다. 따라서 지진시 지반 및 구조물의 거동을 정확히 예측하기 위한 신뢰성 있는 지반 가속도의 증폭현상 평가가 필요하다. 본 연구에서는 1차원 지반응답특성 평가 프로그램인 SHAKE91과 유한차분 프로그램인 FLAC을 이용 하여 폐기물 매립지에서의 지진거동 특성을 분석하였다. 1차원 해석결과 연약층이 존재하는 곳에서 지반변형이 많이 이루어졌고, FLAC 해석결과 폐기물층 사면부에서 뚜렷한 변위벡터가 발생하였으나 내진 2등급 매립지의 허용변위 30cm 이내이므로 해석 대상 구조물은 안전함을 알 수 있었다.

  • PDF

Analysis of collection Characteristics of Landfill Gas Using ]Relative Fluid Permeability of Gas and Water in Waste Landfill (쓰레기 매립지에서 가스-물 상대유체투과도를 적용한 매립가스의 포집특성분석)

  • 김인기;허대기;김현태;김세준;성원모
    • Journal of Korea Soil Environment Society
    • /
    • v.5 no.3
    • /
    • pp.35-54
    • /
    • 2001
  • It is difficult to accurately predict each flow rate of landfill gas and leachate extracted from many of wells, which have been completed into a waste landfill containing gas and water. However it may be approximately predicted if we can define only relative fluid permeability of gas and leachate flowing through landfill porous media. Therefore numerical simulation using multi-phase flow equations makes use of ei s input data of the relative permeability which is measured and calculated in laboratory environment like in-situ, and consequently we can quantitatively obtain each flow rate of gas and leachate from collection wells. These series of technologies can provide with the important informations to determine the success or failure of landfill gas energy and landfill stabilization. This paper analyses the characteristics of landfill gas collection by six classes of case studies for none described landfill.

  • PDF