• Title/Summary/Keyword: 토양매립

Search Result 337, Processing Time 0.022 seconds

A geochemical and Geophysical Study on the Environmental contamination in the Vicinity of Waste Dispodal Site (폐기물 매립지 주변지역에서의 환경오염에 관한 지구화학 및 지구물리학적 연구)

  • Kim, Kyoung-Woong;Shon, Ho-Woong
    • The Journal of Natural Sciences
    • /
    • v.8 no.1
    • /
    • pp.87-92
    • /
    • 1995
  • In the Vicinity of the Sindae-dong waste disposal site in Taejon, the average Cu, pb and Zn concentrations in soils are higher than those in other Korean soils but these are not high enough to cause any harmful effect to human and animal through the crop plants. Copper, Pb and Zn are not detected in the groundwater samples and F, Cl, $NO_2$, $NO_3$ and $SO_4$ concentrations in groundwater samples are lower than drinking water standards. However, the pH of groundwater sample in site D is 5.58 which is not suitable for the drinking water. With the electric resistivity method, the water-containg layers are found in contaminated soils and the resistivity values are considerably low because of the dispersion of plume by the leak of leachates. According to the results from the magnetic survey method, the anomalous values of the total geomagnetic fields and their gradients are found in the sampling site of low resistivity and high trace element concentrations.

  • PDF

Application of Electromagnetic and Electrical Survey for Soil Contamination in Land-Fill Area (쓰레기 매립장의 토양오염 조사를 위한 전자탐사 및 전기탐사)

  • Chang Hyun-Sam;Lim Hae-Ryong;Hong Jae-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.1 no.2
    • /
    • pp.87-91
    • /
    • 1998
  • Geophysical survey techniques, such as electromagnetic(EM), GPR, and electrical method, have been tested in the landfill area to evaluate the applicability of these methods to soil contamination measurement. The EM method has proven to be excellent on mapping the areal distribution of contaminants and the migration path for leachate. Since the field operation of EM technique is simple as well as fast, we think the EM method must be the first choice for these purposes. Electrical survey techniques have proven to be very effective on mapping sectional distribution of contaminants. Generally, the GPR method is very good on high resolution survey of shallow depth, and field data acquisition is simple, too. But the resistivity method gives better information on deep area, for example, deeper than the depth of 20 m.

  • PDF

Applicability of TDR Sensor for Monitoring Moisture Content of Landfill - Focusing on the 2nd Landfill of SUDOKWON Landfill Site - (매립지 함수율 모니터링을 위한 TDR 센서의 적용성 검토 - 수도권매립지 제2매립장을 중심으로 -)

  • Won-Young Choi;Young-Kyu Kim;Chul Hee Lee;Yong Jae Lee;Seung-Kyu Chun
    • Journal of Soil and Groundwater Environment
    • /
    • v.29 no.4
    • /
    • pp.1-11
    • /
    • 2024
  • This study evaluated a method for prompt and periodic monitoring of moisture content in the waste layer of a landfill using a Time Domain Reflectometry (TDR) sensor, aimed at ensuring the stable operation of the bioreactor facility at the 2nd landfill of the SUDOKWON Landfill Site. It was found that the TDR sensor is sensitive to variables such as temperature changes and ion content in both the waste layer and leachate, indicating that a correction equation is necessary. A correction equation derived through regression analysis demonstrated a high correlation (correlation coefficient = 0.9647), and field verification experiments confirmed its reliability with an average deviation of only 1.5%. This verifies that the TDR sensor is effective for measuring and monitoring moisture content in landfills. It is also anticipated to be useful for various applications, including monitoring leachate levels, detecting leachate leakage, and assessing rainwater infiltration.

Groundwater Contamination at the Seokdae Waste Landfill Area of Pusan City (부산 석대 폐기물 매립장 일대의 지하수 오염)

  • 정상용
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.2 no.1
    • /
    • pp.1-8
    • /
    • 1995
  • Wastes produce groundwater contamination, offensive odor, and hazardous gases. This study investigates the contamination of groundwater at the Seokdae waste landfill area and seeks the desirable ways to minimize the groundwater contamination. Groundwater levels, water chemistry and aquifer characteristics of wells were examined around the Seokdae waste landfill. The water chemistry of the Dong stream, the groundwater distribution and flow were also studied. The results of this research show that the estimated quantity of the percolation from the landfill base to the ground is 520 ㎥/day and the extent of groundwater contamination is about 1-1.5 km from the center of the waste landfill. The groundwater contains heavy metals and other toxic elements. The conservation and management of the groundwater of the waste landfill need several monitoring wells to check the quantity and quality of groundwater, pumping wells to extract the contaminated groundwater, and slurry walls to protect the movement of contaminated groundwater.

  • PDF

The Characteristic and Control of Contaminant Transport through the Subsurface of Nanjido Landfill (난지도 매립장 지반을 통한 오염이동 특성과 제어)

  • 장연수;이광열
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.1 no.1
    • /
    • pp.1-5
    • /
    • 1994
  • The contaminant migration through the subsurface of Nanjido landfill is studied using a 2-D finite element model of contaminant transport. The leachate mounding caused by the installation of partial slurry wall around the pheriperal area of the Landfill is analysed using the finite difference model of groundwater flow. Model parameters were validated using in-situ concentration data and the behavior of the transport next 30 years is predicted. The sensitivities of chloride concentration by the change of model parameters, e.g. leachate mounding in the Landfill and the dispersivity are analysed. The results of the analyses show that the maximum chloride concentration level near Han River caused by the leachate of Nanjido Landfill would be 1488mg/1 and comes 17 years after the landfill closure. Increase of the leachate concentration is caused by the increase of both the leachate mounding and the dispersivity. However, the rate of concentration increase becomes higher with the rise of leachate mounding level, while it tends to converge a certain concentration with the increase of the dispersivity.

  • PDF

The Water Environment at the Seokdae Waste Landfill Area in the Pusan Metropolitan City (부산 석대 폐기물 매립지 일원의 수질 환경)

  • 정상용;권해우;이강근;김윤영
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.4 no.4
    • /
    • pp.175-184
    • /
    • 1997
  • The Seokdae Waste Landfill is a middle-sized site used from June, 1987 to May, 1993. Many joints and faults are developed in andesitic rocks and rhyolitic rocks distributed at the landfill. The chemical analyses of leachates, streams and groundwaters sampled in July, 1996 and June, 1997 show that the concentrations of leachates and streams were decreased, and that the groundwater qualities became worse. The groundwater contamination is deeply extended to not only shallow groundwater but also bedrock-groundwater around the Seokdae Waste Landfill Area. The range of groundwater contamination by the leachates is about 500 m to the west and about 1 km to the south from the boundaries of the waste landfill. The development of monitoring wells and pumping wells, the construction of a leachate-treatment facilities, and the adjustment of the existing grout curtains are necessary for the control of water pollution at the Seokdae Waste Landfill Area.

  • PDF

Electrical Surveys at the Seokdae Waste Landfill of Pusan (부산 석대 폐기물 매립지에서의 전기탐사)

  • Kiehwa Lee;Jong-Ryeol Yoon
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.4 no.4
    • /
    • pp.185-190
    • /
    • 1997
  • Electrical surveys were conducted at the Seokdae waste landfill in July,1996. Within the landfill, 4 lines of dipole-dipole surveys and 7 Schlumberger soundings were carried out and 2 soundings in front of the landfill. In the landfill, interpretations of the survey data show low resistivity zones below 10 Ωm to a depth of 50 m from the surface and such low resistivity zones of the D block are thicker than those of the other blocks by about 2~10 m. Considering the depth of the bedrock and the height of waste reclamation, no evidence of bedrock contamination by leachate is indicated. But it is inferred that the weathered zones are contaminated in the landfill. In the block A and B, minor fault having the strike of N$70^{\circ}$W have been confirmed by dipole-dipole surveys, so future contamination of the bedrock by leachate is possible The degree of ground contamination is the highest in the D block due to the leachate plume mainly heading for this block. On the other hand, electrical soundings do not indicate ground contamination by leachate in the front area of the landfill.

  • PDF

단공주입양수 추적자시험을 이용한 폐기물매립장 주변의 침출수 확산 연구

  • Gang Dong-Hwan;Jeong Sang-Yong;Kim Byeong-U
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.105-109
    • /
    • 2005
  • 폐기물매립장에서 발생하는 침출수의 확산정도를 정량적으로 추정하기 위해 매립장 주변에 설치되어 있는 2개 지하수공(BWM-1, BWM-2)에서 단공주입양수 추적자시험이 실시되었다. 브롬(Br-) 이온이 추적자로 이용되었으며, 추적자시험은 주입단계, 체이서단계 및 양수단계의 과정으로 실시되었다. 시험대상 구간은 지표면하 $20{\sim}24m$에 해당하는 파쇄암반층이며, 주입율과 양수율은 추적자시험 이전에 실시되어진 양수시험 자료에 의해 산정되었다. BWM-1 지하수공의 단공주입양수 추적자시험에 의해 추정된 종분산지수는 공극율이 0.01, 0.05, 0.1 및 0.5인 경우에 각각 9.50, 4.25, 3.00, 1.34cm 이다. 시험대수층의 공극율은 대략 $0.05{\sim}0.20$의 범위이며, 따라서 종분산지수는 $2{\sim}4cm$인 것으로 추정된다. BWM-2 지하수공의 단공주입양수 추적자시험에 의해 추정된 종분산지수는 공극율 0.01, 0.05, 0.1 및 0.5인 경우에 각각 3.32, 1.49, 1.05, 0.47cm 이다. 시험대수층의 공극율은 대략 $0.05{\sim}0.20$의 범위이며, 따라서 종분산지수는 $1{\sim}2cm$인 것으로 추정된다. 폐기물매립장에서 침출수가 유출할 경우, BWM-2 지하수공 주변의 파쇄암반층이 BWM-1 지하수공 주변의 파쇄암반층보다 침출수 확산이 2배 정도 빠르게 발생할 것으로 추정되었다.

  • PDF

A Study on the Safety Grounding for Prevention of Electric Shock Hazard in Construction of Industrial Plant in Maritime Landfill Area (해상 매립 지역 산업 플랜트 건설 시 감전 재해 예방을 위한 안전 접지에 관한 연구)

  • Kim, Hong-Yong;Jang, Ung-Burm
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.3
    • /
    • pp.305-312
    • /
    • 2017
  • In our society, the advanced, advanced, and information industries have continued to grow and now live in the era of the fourth industrial revolution. As the industry develops, the load of the users has also increased so much that it is deepened by the energy shortage phenomenon and the construction of additional energy facilities is required. Therefore, energy plant construction work is being actively carried out in the coastal area. In particular, it is common to build a plant in the ground by filling the coast with soil in other regions, reflecting the fact that Korea is lacking in the country when constructing power plants, gas and petrochemical plants. Current domestic grounding designs are designed or constructed to suit only the use of grounding resistors based on the electrical equipment design technical standards. However, in the case of a plant facility constructed in the untested buried soil, when the lightning current and the abnormal current are inputted, the facility operator or the user due to the elevation of the ground potential is seriously exposed to the risk of electric shock disaster. In this paper, we analyze the ground resistivity of the landfilled soil and use a computer program (CDEGS) based on KS C IEC 61936-1, We analyze the contact voltage and stratification voltage and propose a grounding design optimized for plant installation.

Impacts of Chemical Heterogeneities in Landfill Subsurface Formations on the Transport of Leachate (매립지반의 화학적 불균질성이 침출수 이동에 미치는 영향)

  • Lee Kun-Sang
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.5
    • /
    • pp.1-8
    • /
    • 2006
  • The objective of this study is to assess impacts of sorption heterogeneity on the transport of leachate leaked from unlined landfill sites and is accomplished by examining the results from a series of Monte-Carlo simulations. For random distribution coefficient ($K_{d}$) fields with four different levels of heterogeneity ranging from homogeneous to highly heterogeneous, the transport of leachate was investigated by linking a saturated flow model with a contaminant transport model. Impacts of a chemical heterogeneity were evaluated using point statistics values such as mean, standard deviation, and coefficient of variation of the concentration obtained at monitoring wells from 100 Monte-Carlo trials. Inspection of point statistics shows that the distribution of distribution coefficient in the landfill site proves to be an important parameter in controlling leachate concentrations. In comparison to homogeneous sorption, heterogeneous $K_{d^-}$ fields produce the variability in the leachate concentration for different realizations. The variability increases significantly as the variance in the $K_{d^-}$ field and the travel time between source and monitoring well increase. These outcomes indicate that use of a constant homogeneous $K_{d}$ value for predicting the transport of leachate can result in significant error, especially when variability in $K_{d}$ is high.