The effects of introduction of diesel passenger cars on the ventilation requirements for road tunnels (경유승용차 도입이 터널 소요환기량에 미치는 영향분석)

  • Kim, Hyo-Gyu;Song, Seok-Hun;Kim, Nam-Young;Lee, Chang-Woo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.9 no.3
    • /
    • pp.309-321
    • /
    • 2007
  • Since the first diesel passenger car hit the local road in late 2005, the share of diesel cars is growing significantly; possibly up to the level as in the western Europe. In this study, the effects of introduction of diesel passenger cars on the ventilation rate and facility capacity are analyzed for the three individual cases with different basic exhaust rate based on the vehicle age, the vehicle class percentage and the smoke exhaust rate. The target tunnel for this comparative study is a typical 2 km-long 2-lane highway tunnel. Case 1 assuming the current local design standards and the diesel vehicles comprising 40% of the total passenger cars on the road required more ventilation rate and facility capacity than in the case only with the current standards. Case 2 which is the real tunnel currently in the designing stage taking into account the vehicle age but ignoring the diesel vehicle ratio, and Case 3 on the contrary considering the both factors show similar level of ventilation characteristics as EURO-3 emission regulation. Application of the emission standard set by the Ministry of Environment for newly manufactured vehicles in the current local tunnel design standard indicates higher requirements than for EURO-2 regulation, whereas the emission standard came into effect in 2006 results in the ventilation characteristics similar to EURO-4. This study aims at providing fundamental information for assessing the basic emission rate and determining the optimal ventilation rate and facility capacity considering the growing percentage of diesel cars and gradually decreasing level of smoke emission forced by the relevant laws.

  • PDF

A Study on the development of a decision model on free flow and congested traffic conditions to determine the optimal ventilation capacity in highway tunnels (고속도로 터널의 적정 환기용량 계획을 위한 원활 및 지체조건 판별모델 개발에 대한 연구)

  • Kim, Hyo-Gyu;Yoo, Ji-Oh;Lee, Chang-Woo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.4
    • /
    • pp.375-395
    • /
    • 2012
  • According to the local highway tunnel ventilation guideline, ventilation capacity calculation should be performed at the speed ranging from 10 km/h to 80 km/h. This is so reasonable method considering uncongested and congested traffic conditions in urban tunnels. But recently due to low traffic volume and very low congestion frequency in rural highway tunnels, it seems to be an inadequate way to apply the guideline. Therefore the calculation should be performed separately for the free flow and congested traffic cases classified by the appropriate decision model. This paper aims at determining unnecessary running speed range for reasonable tunnel ventilation design, considering free flow and congested traffic conditions. Firstly, traffic volumes in highway tunnels were collected and if any, the causes of congestion were investigated. And with concept of 'margin speed'($u-u_m$), the decision model on traffic congestion was developed. Applicability of the decision model was also analyzed with case study. According to the results, when design speed is 100 km/h, with V/C less than 0.1, then the range of unnecessary speed in tunnel ventilation design is less than 40 km/h; for $V/C{\leqq}0.35$, $V/C{\leqq}0.6$ and $V/C{\leqq}0.75$, the unnecessary speed ranges are found to be ${\leqq}30$, ${\leqq}20$ and ${\leqq}10km/h$, respectively.

터널 환기시설 단계건설 연구와 터널 방재설비의 설계경향

  • 윤철욱;이상표;김남석
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.30 no.7
    • /
    • pp.19-23
    • /
    • 2001
  • 장대터널내 환기설비의 단계적인 건설방안에 관하여 한국도로공사와 한국건설기술연구원이 함께 수행한 연구내용을 소개하고, 또한 현재 적용되고 있는 방재설비의 설계흐름과 컴퓨터 시뮬레이션을 이용한 제연설비의 설계경향에 대하여 간단히 소개하고자 한다.

  • PDF

Experimental Study on the Designed Ventilation System Performance at Rescue Station in Tunnel Fire (터널 내 화재발생시 구난역 내의 설계된 환기 시스템 성능에 대한 실험적 연구)

  • Kim, Dong-Woon;Lee, Seong-Hyeok;Ryou, Hong-Sun;Yoon, Sung-Wook
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • In this study, the l/35 reduced-scale model experiment were conducted to investigate designed ventilation system performance at rescue station in tunnel fire. A model tunnel with 2 mm thick of steel, 10 m long, 0.19 m high and 0.26m was made by using Froude number scaling law. The cross-passages installing escape door at the center. were connected between accident tunnel and rescue tunnel. The n-heptane pool fire, $4cm\times4cm$, with heat release rate 698.97W were used as fire source. The fire source was located in the center and portal of accident tunnel as Worst case.. An operating ventilation system extracted smoke amount of 0.015 cms. The smoke temperature and carbon monoxide. concentration in cross-passage were measured to verify designed ventilation system. The results showed that, in center fire case without ventilation in accident tunnel, smoke did not propagated to rescue station. In portal tire case, smoke spreaded to rescue station without ventilation. But smoke did not propagated to rescue station with designed ventilation.

On-site Application of a Vehicle Tunnel Ventilation Simulator (도로터널 환기시뮬레이션 모델 현장적용 연구)

  • 이창우;김효규
    • Tunnel and Underground Space
    • /
    • v.11 no.4
    • /
    • pp.319-327
    • /
    • 2001
  • Introduction of new design tools has been required to optimally design and operate the ventilation system of long vehicle tunnels.. The demand has led to wide spread use of the simulation technique throughout the would to analysis the dynamic relationship among the variables associated with vehicle tunnel ventilation. This paper aims at performing on-site study at local tunnels to test the applicability of NETVEN, a simulation model vehicle tunnel ventilation. The study was carried out at four urban as well as highway tunnels model of vehicle tunnel ventilation. The study was carried out at four urban as well as highway tunnels employing different ventilation systems as well as traffic methods. There were some discrepancies sound between the simulation output and measurements and the following four factors are considered to mainly cause those disagreement. (1) The real situation shows distinctive transient and retarding characteristics with respect to air flow and contaminant dispersion, while ventilation forces are not steady-state and in particular those traffic and climatic variables show significant instantaneous variation. (3) Near the exit portal, the CO levels show bigger differences. The general trend is that data with higher CO concentrations carry bigger discrepancies. Turbulent diffusion is though to be the main reason for it and also contribute to the fact hat the highest CO concentrations are found at the locations somewhat inward, not at the exit portals. (4) Higher traffic rate results in higher discrepancies of ventilation velocity. Along with the exhaust characteristics, the vehicle aerodynamic characteristics need to be studied continuously in order to reduce the velocity disagreement.

  • PDF

A study on the air leakage performance improvement of duct coupling for temporary ventilation of long subsea tunnel (초장대 해저터널의 공사중 덕트 접속부의 누풍 성능 개선에 관한 연구)

  • Jo, Hyeong-Je;Min, Dea-Kee;Kim, Jong-Won;Lee, Ju-Kyung;Beak, Jong-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.2
    • /
    • pp.319-333
    • /
    • 2017
  • The construction of long sub-sea tunnel does not provide the favorable condition for the installation of ventilation system to be used during construction due to the constrained construction space. For the ventilation system required during construction, the artificial island where ventilation shaft is located is constructed at some location along the sub-sea tunnel route, which requires a high construction cost. Therefore, it is intended, as much as possible technically, to minimize the construction of artificial island. However, this requires a longer distance between ventilation shafts, there-by causing increased air leakage at the ventilation duct connection points due to the higher fan pressure being required to deliver ventilation air. Previously the air leakage was studied as an important issue. In this study experiments were carried out to develop the improved duct connection method considering various conditions such as, tunnel length, etc. Additionally, its performance results with leakage rates are shown and compared to the "S" class leakage rate of SIA. As a result, the new duct coupling type of improved method is analyzed as applicable to such a 30 km long tunnel with the leakage rate of $1.46mm^2/m^2$, which is better performance than SIA leakage rates.

Experimental Study on the Effect of the Area Ratio between Shaft and Tunnel and Heat Release Rate on the Plug-holing Phenomena in Shallow Underground Tunnels (저심도 도로터널에서 터널과 수직환기구의 단면적 비와 열방출률이 Plug-holing 현상에 미치는 영향에 관한 실험연구)

  • Hong, Kibea;Na, Junyoung;Ryou, Hong Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.619-625
    • /
    • 2019
  • It is difficult to design because of the plug-holing phenomenon in which the amount of smoke discharged from the vertical vent is smaller than the designed amount of smoke. In this study, the effect of cross-sectional area ratio of tunnel and natural ventilation and heat release rate of fire source on plug-holing phenomenon occurring in natural ventilation system was experimentally analyzed. In the experiment model reduced to 1/20 size, the aspect ratio of the tunnel and the vertical vent was fixed, and the influence on the plug-holing phenomenon was confirmed by varying the sectional area ratio of the tunnel and the vertical vent. Experimental results show that the plug-holing phenomenon is caused by the comparison of the smoke boundary layer temperature with the temperature in the vertical vents, and the flow and temperature distribution characteristics under the vertical vents are changed as the cross-sectional area ratio of the tunnel and vertical vents increases. The plug-holing phenomenon is affected by the cross-sectional area ratio between the tunnel and the vertical ventilation. The greater the cross-sectional area ratio, the greater the probability of plug-holing.

A study on the effective fire and smoke control in transverse oversized exhaust ventilation (횡류식 선택대배기환기에서의 배연특성에 관한 연구)

  • Han, Sang-Pil;Jeon, Yong-Han
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.6
    • /
    • pp.451-462
    • /
    • 2011
  • The smoke control system plays the most important role in securing evacuation environment when a fire occurs in road tunnels. Smoke control methods in road tunnels are classified into two categories which are longitudinal ventilation system and transverse ventilation system. In this study it is intended to review the characteristics of smoke behavior by performing numerical analysis for calculating the optimal smoke exhaust air volume with scaled-model and simulation when a fire occurs in tunnels in which transverse ventilation is applied, and for obtaining the basic data required for the design of smoke exhaust systems by deriving optimal smoke exhaust operational conditions for various conditions. As a result of this study, when the critical velocity in the tunnel is 1.75 m/s and 2.5 m/s, the optimal smoke exhaust air volume has to be more than $173m^3/s$, $236m^3/s$ for the distance of the smoke moving which can limit the distance to 250 m. In addition, in case of uniform exhaust the generated smoke is effectively taken away if the two exhaust holes near the fire region are opened at the same time.

A Study on the Ventilation Performance for Fan flow effect of Model Tunnel (모형도로터널의 환기성능에 미치는 FAN유량에 관한 연구)

  • Kim, Se-Jong;Lee, Ju-Hee;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.123-126
    • /
    • 2010
  • 터널내에 설치되는 제트팬은 비상시에는 연기와 같은 유독가스를 제거하는데 사용되며 평상시에는 장대터널에 있어서 차량에 의해 발생한 오염공기를 제거하는 중요한 역할을 한다. 파량의 피스톤효과에 의해서 일부 제거되기는 하나 1km이상의 장대터널에서는 반드시 필요로 한다. 이러한 제트팬의 효율적인 환기 및 제연설계를 위하여 CFD해석과 더불어 모형실험을 실시함으로서 터널내에 소실되는 에너지를 정량화하고 그 원인 파악과 함께 효율적인 환기설계를 위한 연구이다.

  • PDF

Worldwide Trends in the Research Topics for the Vehicle Tunnel Ventilation (도로터널 환기관련 연구동향)

  • 이창우
    • Tunnel and Underground Space
    • /
    • v.12 no.3
    • /
    • pp.152-157
    • /
    • 2002
  • Optimal design of the long tunnels with large cross sections essential for the effective development of the limited land in Korea becomes more and more difficult owing to the constantly changing social, economic, environmental and technological factors. Deficiency of the domestic research works till now on the elementary topics on tunnel ventilation retards progress on developing the key technologies urgently required for designing and managing the long and large tunnels. This paper aims at identifying the subjects on which research must be carried out for the construction and management of vehicle tunnels in Korea by means of scrutinizing the contents of the publications since 1991 at the International Symposium on Aerodynamic and Ventilation of Vehicle Tunnels, the only international conference on the tunnel ventilation.