• 제목/요약/키워드: 터널라이닝

검색결과 446건 처리시간 0.027초

터널 라이닝 내부에 설치한 열교환기의 현장모니터링 연구 (Study on long-term monitoring of heat exchanger installed in the tunnel lining)

  • 이철호;박문서;최항석;손병후;정재형
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.195.1-195.1
    • /
    • 2011
  • This paper presents an experimental study on a new potential geothermal energy source obtained from tunnel structures. An "energy textile", which is a textile-type ground heat exchanger, was fabricated between a shotcrete layer and a guided drainage geotextile in the tunnel lining system. To examine the long-term thermal behavior of the energy textile, the difference in temperatures of the inlet and outlet fluid circulating through the heat exchange pipe within the energy textile was monitored using a constant-temperature water bath. Daily heat exchange rate of the energy textile during cooling operation was estimated from the measured temperatures of the inlet and outlet fluid through the energy textile. The air and ground temperature was also continuously monitored. The operation of the energy textile as a ground heat exchanger was simulated using a 3D numerical CFD model (Fluent). The thermal conductivity of shotcrete and concrete lining components and temperature variation of air in the tunnel were incorporated in the model. The numerical analysis shows a good agreement with the long-term monitoring result.

  • PDF

실험값을 이용한 NATM 터널의 보강효과에 관한 수치 해석적 연구 (A Numerical Study on the NATM Tunnel Reinforcement using Centrifuge Model Experimental value)

  • 허경한;김낙석
    • 한국방재학회 논문집
    • /
    • 제4권2호
    • /
    • pp.13-18
    • /
    • 2004
  • 본 연구는 유한차분법을 이용하며 변위 및 응력에 1차 적인 영향을 주는 매개변수를 구축하였으며 이를 이용하여 기존 원심모형 실험값 중 천단변위, 내공변위 결과를 수치해석상결과와 비교하였고, 모형실험에서 다양하게 구현할 수 없었던 응력, 라이닝 설치의 시간적 효과를 고려하여 강성의 차이에 따른 매개변수연구를 수행하였다. 연구결과 3차원 해석을 통한 대구경강관 그라우팅의 보강물성치는 원지반 강성의 8배인 E=4,000tf/m2일때 개략적인 지반보강효과가 발현되는 것으로 확인되었다.

시공중 터널 숏크리트 라이닝 작용응력 측정기법 개발을 위한 수치해석적 연구 (Numerical Study for Tunnel Shotcrete Lining Operated Stress Measurement Techique Development During a Construction)

  • 신휴성;김동규;정용수;황재홍;배규진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.754-761
    • /
    • 2008
  • In general, stress measurement of existent shotcrete lining be used by pressure cells. but, measuring instrument is lost by high pressure at shotcrete lining construction and pressure cell's measurement value have to low believability by natural conditions like curing temperature. In this study, proposed techniques to measure without utilizing sensitive stress sensor in natural condition at point that want stress of shotcrete lining after shotcrete lining construction. Executed numerical analysis to forecast stress level that interact in tunnel shotcrete lining, measured strain of hole by load action through hole in shotcrete lining. 3D FEM(finite element method) is enforced through various parameters curing time of shotcrete lining, thickness, load condition. Different model cases applied by parametic study. As analysis result, it could grasp development possibility of method that propose this time because it could examine corelation with strain by near hole of shotcrete lining and stress about load condition.

  • PDF

터널 숏크리트 라이닝의 장기 내구성 평가를 위한 실험기법 개발 (Development of experiment technology for assessment of shotcrete lining long-term degradation in tunnels)

  • 임종진;신휴성;배규진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.439-444
    • /
    • 2005
  • Shotcrete lining is likely to be deteriorated due to the ground water which the lining is exposed to. Some tunnel collapses seemed to be affected by shotcrete degradation were reported. But there isn't any assessment method of shotcret long-term degradation. So, Experimental technology for shotcrete long-term degradation modeling was developed in this study. The shotcrete long-term degradation modeling, developed in other study in Korea Institute of Construction Technology, require the time-history of volume change. Digital strain observation system was used to acquire the time-history of volume change. To verify the Strain Observation Digital System, the measurement using the system was compared to the one using a micrometer. Through this process, The experiment for shotcrete long-term degradation modeling was set up.

  • PDF

투수 및 암반거동 파악을 위한 터널 라이닝의 역해석 (Tunnel-Lining Back Analysis for Characterizing Seepage and Rock Motion)

  • 최준우;이인모;공정식
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.248-255
    • /
    • 2006
  • Among a variety of influencing components, time-variant seepage and long-term underground motion are important to understand the abnormal behavior of tunnels. Excessiveness of these two components could be the direct cause of severe damage on tunnels. however, it is not easy to quantify the effect of these on the behavior of tunnels. These parameters can be estimated by using inverse methods once the appropriate relationship between inputs and results are clarified. Various inverse methods or parameter estimation techniques such as artificial neural network and least square method can be used depending on the characteristics of given problems. Numerical analyses, experiments, or monitoring results are frequently used to prepare a set of inputs and results to establish the back analysis models. In this study, a back analysis method has been developed to estimate geotechnically hard-to-known parameters such as permeability of tunnel filter, underground water table, long-term rock mass load, size of damaged zone associated with seepage and long-term underground motion. The artificial neural network technique is adopted and the numerical models developed in the firstpart are used to prepare a set of data for learning process. Tunnel behavior especially the displacements of the lining has been exclusively investigated for the back analysis.

  • PDF

다발형 폴리아미드섬유 보강 콘크리트의 휨거동에 관한 실험적 연구 (A Experimental Study on the Flexural Behavior of Bundle Type Polyamide Fiber Reinforced Concrete)

  • Jeon, Chan Ki;Jeon, Joong Kyu
    • 한국재난정보학회 논문집
    • /
    • 제10권1호
    • /
    • pp.61-70
    • /
    • 2014
  • 일반적으로 건설재료 용도로 많이 사용되고 있는 유기섬유 보강 콘크리트는 섬유 자체의 인장강도 및 탄성계수는 낮지만, 휨거동, 균열에 대한 저항성 및 충격저항성 등의 특성은 우수하며, 내화학성이 뛰어나고 부식의 우려가 없는 것으로 널리 알려져 있다. 최근 해외에서는 유기섬유 보강재를 터널 숏크리트와 프리캐스트 세그먼트 라이닝, 교량 슬래브 및 PC제품 분야에서 일부 활용되고 있으며, 그 종류 또한 다양하다. 본 연구에서는 다발형 폴리아미드섬유를 혼입한 콘크리트의 휨거동 특성을 ASTM C 1609 및 KS F 2566에 준하여 하중-처짐 관계를 도출하여 유기섬유 보강 콘크리트의 적용 가능성을 검토하였다.

인공균열 주위의 변형과 터널 숏크리트 라이닝 응력간의 상관관계에 대한 수치해석적 검토 (Numerical approach on relationship between deformation of artificial crack and stress acting on tunnel shotcrete lining)

  • 신휴성;권영철;배규진;김경신;김홍택
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.64-71
    • /
    • 2009
  • The stresses acting on shotcrete lining of tunnel have been measured virtually by monitoring instruments installed during construction. However, the malfunction of instrument and the lack of consistency of signal have always been controversial, but re-installation of instrument after construction of tunnel lining is practically impossible. Therefore, authors have carried out the study to develop a new technique for estimating the stress acting on shotcrete lining during and after construction. In the technique, stresses of shotcrete lining can be estimate by the measurement of deformation of free face. Therefore, the relationships between the stresses of shotcrete lining and deformation of free surface are indispensable factor. In this paper, the parametric study using 2D FEM analysis was carried out to estimate the relationships between the stress level acting on the tunnel shotcrete lining and the deformation near the free face (e.g. artificial crack in this study). The distribution of stresses of shotcrete lining is also investigated in this study as the preliminary investigation for the large-scale tunnel lining test and detailed 3D FEM analysis.

  • PDF

토목공학 분야에서의 충격반향법의 응용 (Application of Impact Echo Method to Civil Engineering Fields)

  • 정연문;하희상
    • 지구물리와물리탐사
    • /
    • 제3권3호
    • /
    • pp.94-100
    • /
    • 2000
  • 금속 물체의 내부 상태를 조사하기 위하여 사용되고 있는 여러 가지 비파괴 조사법들은 콘크리트 재료의 불균질성으로 인하여 콘크리트 물체에의 적용에는 한계가 있다 충격반향법은 물성의 변화가 존재하는 경계면이나 결함 부위에서 반사되는 탄성파의 공진 주파수를 이용하는 비파괴 조사법으로서 콘크리트 구조물의 내부 상태를 파악하기 위하여 활용될 수 있다. 본 연구에서는 충격반향법의 현장 적용을 위한 자료획득 시스템을 구축하였고 여러 가지 조건하에서 현장 시험을 수행하였다. 콘크리트 구조물의 두께 및 결함, 공동 존재 여부, 옹벽 뒷채움 상태와 터널 라이닝의 두께 및 결함, 그리고 활주로의 포장 두께 및 결함등의 조사를 위하여 충격반향법을 적용하였다. $10\%$ 이하의 오차 범위내에서 결과를 제공함으로써 충격반향법의 토목분야에서의 활용 가능성이 입증되었다.

  • PDF

터널 화재시나리오에 따른 콘크리트 PC패널 라이닝의 전열특성에 관한 해석적 연구 (An Study on Heat Transfer Analysis to Concrete PC Pannel Lining under Tunnel Fire Scenario)

  • 김형준;김흥열;박경훈;신현준
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2009년도 춘계학술논문발표회 논문집
    • /
    • pp.487-492
    • /
    • 2009
  • This study was performed FE numerical analysis under 120-minute fire conditions, using the ABAQUS, a wide use software, on the basis of the test results by concrete tunnel lining fire strengths (ISO, RWS, and MHC). The concrete material test was to secure the material properties of concrete linings, which were numerical analysis input conditions. And then built the material properties, such as specific heat, heat transfer rate, heat expansion rate, density, elasticity coefficient and compression strength under high temperature conditions, as database at 20 $^{\circ}C$ to 800 $^{\circ}C$, applying them to analysis as input values. As a result, the tunnel linings under RWS fire conditions saw fire temperature rose to maximum 1119 $^{\circ}C$at the location of 5 mm above a thermal surface, and saw surface temperature amount to 1214 $^{\circ}C$ in the middle part.

  • PDF

운영중인 지하구조물 누수처리를 위한 유도배수공법 개발 및 성능 검증 (Development and performance verification of induced drainage method for leakage treatment in existing underground structures)

  • 김동규;임민진
    • 한국터널지하공간학회 논문집
    • /
    • 제19권3호
    • /
    • pp.533-549
    • /
    • 2017
  • 본 연구에서는 지하 콘크리트 구조물 내로 누수된 지하수를 유도하여 배수하는 유도배수공법을 제시하였다. 유도배수공법은 유도배수판, 철망, 고정핀, 광물질 혼입 모르타르로 구성된다. 시공성 향상을 위하여 유도배수판 및 철망은 공압타카와 고정핀를 사용하여 콘크리트 표면에 부착하였다. 고로슬래그미분말을 30% 혼입한 모르타르는 뿜어 붙임 모르타르 장비를 사용하여 유도배수판 및 철망 표면에 타설하였다. 유도배수공법의 현장 시공성 및 성능 검증을 위하여 재래식 콘크리트라이닝 터널과 콘크리트 옹벽에서 시험시공을 수행하였다. 시험시공 완료 3년 후 유도배수공법은 성능저하의 문제점이 없는 것으로 판단되었다. 재령 14일과 3년에 뿜어 붙임 모르타르의 부착력 실험을 수행하였다. 유도배수판 표면에 철망을 적용한 경우 뿜어 붙인 모르타르의 부착력은 재령 14일에 1.04 MPa, 재령 3년에 1.46 MPa로 측정되었다. 철망을 적용하지 않은 경우의 부착력은 재령 14일에 1.13 MPa로 측정되었지만, 재령 3년에는 0.89 MPa로 기준 부착력 1 MPa보다 낮게 측정되었다.