Analysis of Indoor Thermal Environment and Energy Consumption in Office Building Controlled by PMV (PMV 제어에 따른 사무소 건물의 실내열환경과 에너지소비량 분석)

  • Jang, Hyang-In;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.4
    • /
    • pp.15-22
    • /
    • 2013
  • The purpose of this study is to analyse the effects of air conditioned room controlled by PMV(Predicted Mean Vote)for energy consumption and human comfort in office building. The 'EnergyPlus' was used for the evaluation of indoor thermal environment and energy consumption by the controls of room temperature and PMV. The result indicates that the PMV control could prove more profitable method for improvement of indoor thermal environment and energy conservation. Consequently, PMV control has a distinct advantage over most other control methods. An additional study is required to establish the various thermal comfort control for rooms on the basis of this work.

Controller Design of Farm Produce Dryer (농산물 건조기의 제어기 설계)

  • Lim Seog-Ku
    • Proceedings of the KAIS Fall Conference
    • /
    • 2005.05a
    • /
    • pp.166-168
    • /
    • 2005
  • 근래에 이르러 농가에서 건조기의 사용이 증가하였지만 대부분의 건조기는 강한 열을 이용하는 방식으로서 고추와 같은 농산물인 경우 맛과 향에서 태양초에 비해 품질이 떨어지는 현상이 자주 있었다. 본 논문에서는 가격 효율성, 연료비 경제성, 맛과 향 그리고 건조시간의 단축이 고려된 건조기 시스템을 개발하였다. 이를 위해 농산물 건조기의 전 기능을 마이크로프로세서의 제어에 의해서 농산물 종류별로 자동적으로 건조할 수 있도록 one touch 방식으로 실현하는 것을 최종 목표로 하였다.

  • PDF

A Study on the Performance of 100 W Thermoelectric Power Generation Module for Solar Hot Water System (태양열 온수 시스템에 적용 가능한 100 W급 열전발전 모듈 성능에 관한 연구)

  • Seo, Ho-Young;Lee, Kyung-Won;Yoon, Jeong-Hun;Lee, Soon-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.1
    • /
    • pp.21-32
    • /
    • 2019
  • Solar hot water system produces hot water using solar energy. If it is not used effectively, overheating occurs during the summer. Therefore, a lot of research is being done to solve this. This study develops thermoelectric power module applicable to solar hot water system. A thermoelectric material can directly convert thermal energy into electrical energy without additional power generation devices. If there is a temperature difference between high and low temperature, it generate power by Seebeck effect. The thermoelectric module generates electricity using temperature differences through the heat exchange of hot and cold water. The water used for cooling is heated and stored as hot water as it passes through the module. It can prevent overheating of Solar hot water system while producing power. The thermoelectric module consists of one absorption and two radiation part. There path is designed in the form of a water jacket. As a result, a temperature of the absorption part was $134.2^{\circ}C$ and the radiation part was $48.6^{\circ}C$. The temperature difference between the absorption and radiation was $85.6^{\circ}C$. Also, The Thermoelectric module produced about 122 W of irradiation at $708W/m^2$. At this time, power generation efficiency was 2.62% and hot water conversion efficiency was 62.46%.

Demonstration study on Heating and Hot water According to Control Condition of Solar System (태양열 시스템의 제어조건에 따른 난방 및 급탕 실증연구)

  • Kwak, Hee-Youl;Kim, Jeong-Bae;Joo, Hong-Jin;Kim, Jong-Bo
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.4
    • /
    • pp.119-126
    • /
    • 2006
  • This study describes thermal performance of heating and cooling demonstration system using ETSC(Evacuated tubular solar collector) installed at Seo-gu art center of Kwangju. For demonstration study, a reading room with about $350m^2$ was heated and cooled using that system. The demonstration system was consisted of ETSCs, storage tank, hot water supply tank, subsidiary boiler, and subsidiary tank. From January to March in 2006, demonstration test were performed with 4 control mode to find the optimum control condition for solar thermal system. After experiments and analysis, this study found that solar thermal system of control mode IV was corresponded to 78% for the hot water supply and 49% for space heating.

The Characteristic Refinement of Poly-Si by Uni-directional Solidification with Thermal Gradient (일방향 응고시 온도 구배에 의한 다결정 실리콘 정련 특성)

  • Jang, Eunsu;Yu, Joon-Il;Park, Dongho;Moon, Byungmoon;Yu, Tae U
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.59.2-59.2
    • /
    • 2010
  • 결정형 태양 전지의 보급화를 위하여 고순도 실리콘을 저렴하게 제조할 수 있는 기술 개발이 필요하다. 본 연구에서는 고순도 실리콘을 경제적으로 제조하기 위하여 대역 정제에 의한 일방향성 응고법을 이용한 정련 연구를 진행하였으며, 응고 속도와 고 액상의 온도 구배가 정련도에 미치는 영향을 분석 하였다. 본 실험에 사용된 일방향 응고장치는 실리콘 용탕이 장입된 도가니 하부의 열 교환기를 통한 냉각에 의해 용탕 하부에서 상부 방향으로의 일방향성 응고가 진행되며, 응고 진행시 용탕의 흔들림에 의한 정련능의 감소를 방지하기 위해 가열 영역이 이동하는 Stober 공정을 채택하였다. 가열 영역은 실리콘 용융을 위한 상부 가열 영역과 응고 진행시 응고부의 온도 제어를 위한 하부 가열 영역으로 구성되어 있으며, 두 가열 영역의 온도 제어를 통해 응고중인 실리콘의 고 액상의 온도 구배를 조절하였다. 일방향 응고에 의한 정련법에서 고 액상의 온도 구배가 증가할수록 2차 수지상의 발달이 감소하고, 주상정의 수지상 형태를 유지하게 되어 고 액 공존영역에서 액상 영역으로의 확산이 원활하게 이루어져 분배계수를 이용한 정련도가 좋아지게 되며, ICP 분석을 통해 온도 구배의 증가에 따라 정련능이 증가하는 양상을 확인 할 수 있었다. 고 액상의 온도 구배의 조절을 통한 공정 시간 대비 정련도의 향상을 통해 결정형 태양전지의 생산성의 증가를 통한 저가화를 이룰 수 있을 것이다.

  • PDF

Design of the Condenser and Automation of a Solar Powered Water Pump (태양열 물펌프의 운전 자동화 설계)

  • Kim Y. B.;Son J. G.;Lee S. K.;Kim S. T.;Lee Y. K.
    • Journal of Animal Environmental Science
    • /
    • v.10 no.3
    • /
    • pp.141-154
    • /
    • 2004
  • The solar powered water pump is very ideal equipment because solar power is more intensive when the water is more needed in summer and it is very helpful in the rural area, in which the electrical power is not available. The average so]ar radiation energy is 3.488 kWh/($m^2{\cdot}day$) in Korea. In this study, the automatic control logic and system of the water pump driven by the radiation energy were studied, designed, assembled, tested and analyzed for realizing the solar powered water pump. The experimental system was operated automatically and the cycle was continued. The average quantity of the water pumped per cycle was about 5,320 cc. The cycle time was about 4.9 minutes. The thermal efficiency of the system was about $0.030\%$. The pressure level of the n-pentane vapour in flash tank was 150$\%$450 hPa(gauge) which was set by the computer program for the control of the vapour supply. The pressure in the condenser and air tank during cycles was maintained as about 600 hPa and 1,200 hPa respectively. The water could be pumped by the amount of 128kg/($m^2{\cdot}day$) with the efficiency of $0.1\%$ and the pumping head of 10 m for the average solar energy in Korea.

  • PDF

대형 열진공챔버용 극저온 모사장치 개발

  • Lee, Sang-Hoon;Cho, Hyok-Jin;Seo, Hee-Jun;Moon, Guee-Won;Choi, Seok-Weon
    • Aerospace Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.103-108
    • /
    • 2004
  • The space environment is characterized such a severe condition as high vacuum and very low temperature. Since a satellite will be exposed such a space environment as soon as it goes into the its orbit, thermal vacuum test should be carried out to verify the performance of the satellite on the ground under the space environmental conditions. KARI has a thermal vacuum chamber with useful dimensions of ∮3.6m×L3m, in which KOMPSAT-1 and KOMPSAT-2 satellites were tested. But very large thermal vacuum chamber with useful dimensions of ∮8m×L10m has been needed to meet the future demand of large satellites. Generally, the thermal vacuum chamber can be divided into a vacuum system and a thermal system. Especially, a cryogenic system in the thermal system simulates very low temperature of -196℃ under the high vacuum condition. In this paper, we propose the new cryogenic system can be applied to the future large thermal vacuum chamber.

  • PDF

저궤도 위성 열진공 시험의 전자 시험 설계

  • Gwon, Dong-Yeong;Jeon, Mun-Jin;Lee, Na-Yeong;Kim, Dae-Yeong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.170.2-170.2
    • /
    • 2012
  • 위성의 열진공 환경 시험은 고진공 극저온의 우주 환경을 모사하여 열제어 기능 및 임무 수행 능력을 검증하는 시험이다. 이 시험에서는 위성 주위에 부착한 방열판으로 위성 외각 온도를 변화 시켜 위성의 태양 지향 자세 또는 심우주 지향 자세를 모사하며, 이에 따른 위성의 온도 변화에 따라 지상 시험 장비로 위성의 히터 설정, 유닛 전원 형상의 변경 등을 해야한다. 또한 극고온 또는 극저온의 환경에 장시간 연속적으로 노출된 상태에서 위성의 기본적인 기능부터 영상 미션까지 검토하는 CPT 시험을 수행하며, 이 CPT 시험은 극한의 위성 상태의 시험이기 때문에 온도를 고려한 전자 시험 설계 및 24시간 위성 모니터링 시스템, 위험상황 발생 시 대처 방안 등에 대한 준비가 필요하다. 본 논문에서는 열진공 시험 시의 전자시험의 형상과 설계에 대해서 설명하고, 시험 결과에 대해서 정리하였다.

  • PDF

A Case Study of the Automatical Blasting Vibration Measuring System Using the Solar Power Supply (태양전지 전원 공급장치를 이용한 발파진동 자동화 계측시스템 운영 사례연구)

  • Yoo, Ji-Wan;Lee, Tai-Ro;Kim, Jung-Ryul;Kim, Young-Suck
    • Explosives and Blasting
    • /
    • v.26 no.2
    • /
    • pp.92-98
    • /
    • 2008
  • Measuring methods of the blasting vibration were generally divided the. manual method and the automatical method. When using the automatical method, field data of the vibration meter can be transferred to a operation computer by using remote equipments. In this study new automatical system using solar power supply is to be introduced. New automatical system is well suited for the field which is difficult to access and is needed frequent measurements of the blasting vibration. And it can make easy to accumulate the data and control the blasting vibration for safe blasting.

Demonstration study on Heating and Hot water According to Control Condition of Solar System (태양열 시스템의 제어조건에 따른 난방 및 급탕 실증연구)

  • Joo, Hong-Jin;Kwak, Hee-Youl;Kim, Jeong-Bae;Kim, Jong-Bo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.832-837
    • /
    • 2006
  • This study describes thermal performance of heating and cooling demonstration system using ETSC(Evacuated tubular solar collector) installed at Seo-gu art center of Kwangju. For demonstration study, a reading room with about $331m^2$ was heated and cooled using that system. The demonstration system was consisted of ETSCs, storage tank, hot water supply tank, subsidiary boiler, and subsidiary tank. From January to March in 2006, demonstration test were performed with 4 control mode to find the optimum control condition for solar thermal system. After experiments and analysis, this study found that solar thermal system of control mode IV was corresponded to 78% for the hot water supply and 49% for space heating.

  • PDF