• 제목/요약/키워드: 태양광발전 설비

검색결과 279건 처리시간 0.031초

실측데이터를 이용한 저에너지주택의 에너지성능평가 (Energy Performance Evaluation of Low Energy Houses using Metering Data)

  • 백남춘;김성범;오병칠;윤종호;신우철
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.369-374
    • /
    • 2015
  • This study analyzed analyzes the energy performance of six houses in Daejeon completed which were built in 2011. Observed The observed houses, which were all designed and constructed inof the same size and structure, are were highly insulated with triple Low-E coating windows; the insulation level of the walls is was $0.13W/m^2K$ and that of the roof is was $0.10W/m^2K$. As electric houses, all of the energy supplied to the houses, including for cooking, is was supplied by electricity. A and 3~4 kWp of photovoltaic system and a 3~5 kW of ground source heat pump (GSHP) were installed in each house tofor providing provide space heating/and cooling and hot water are installed. We constructed a Web-based remote monitoring system in order to understand energy consumption and the dynamic behavior of the energy system. T, and the results of our metering data analysis of 2013 are as follows. First, the annual residential energy consumption is was 4,400 kWh (${\sigma}=1,209$) and GSHP energy consumption is was 5,182 kWh (${\sigma}=1,164$). Second, residential energy consumption ranked highest in average energy usage, with at 45% of the total, followed by heating with at 30%, hot water supply with at 17% and cooling with at 6%. Third, the average energy independence rate is was 51.8%, the GFA (Gross gross floor area) criteria average energy consumption unit is was $48.7kWh/m^2yr$ (${\sigma}=10.1$), and the net energy consumption unit (except the energy yield of the PV systems) is was $24.7kWh/m^2yr$ (${\sigma}=8.8$).

온실설비 작동용 태양광발전시스템의 발전 성능 분석 (Power Generating Performance of Photovoltaic Power System for Greenhouse Equipment Operation)

  • 윤용철;배용한;유영선;이성현;서원명
    • 생물환경조절학회지
    • /
    • 제18권3호
    • /
    • pp.177-184
    • /
    • 2009
  • 본 연구는 온실 운영에 필요한 전력량을 확보함으로서 온실경영비 절감을 목적으로 우선 태양광발전시스템을 온실의 인접한 건물의 옥상에 설치하여 기상상태에 따른 발전량을 실험적으로 검토하였다. 연구결과를 요약하면 다음과 같다. 실험기간 동안 최고, 평균 및 최저온도는 각각 $0.4{\sim}34.1,\;-6.1{\sim}22.2$$-14.1{\sim}16.7^{\circ}C$ 정도의 범위에 있었다. 그리고 일사량의 경우, 최대, 평균 및 최저값은 각각 $28.8MJ{\cdot}m^{-2}$, $14.9MJ{\cdot}m^{-2}$$0.6MJ{\cdot}m^{-2}$ 정도였고, 전력은 일사량에 비례해서 증가하지 않고 약 750W 전후에서 거의 일정한 것을 알 수 있었다. 일일 최대, 평균 및 최소 소비전력량은 각각 약 5.2kWh, 2.5kWh및 0kWh정도였다. 본 실험에 사용된 시스템의 평균 소비전력량을 기준으로 보면, 온풍기의 용량 및 작동시간이 작은 경우는 충분하지만 큰 경우는 부족한 것으로 나타났다. 온풍기의 용량이 큰 경우, 어레이 면적이 현재의 약 3배인 약 $21m^2$ 정도이면 평균 전력량으로 충분할 것으로 판단되었다. 물론 어레이의 온도가 높아지는 한 여름철에는 일사량에 비례해서 발생 전력이 증가하지 않은 것으로 나타났지만, 현재까지 실험결과로 보면, 두 인자간에 상관계수가 0.84 정도로 상관관계가 높은 것으로 나타났다.

스마트 가로등 시스템을 적용한 수익형 도시공원모델에 관한 연구 (A Study on the Profitable Urban Park Model using Smart Street Light System)

  • 이지희;조한보;김태한
    • 한국조경학회지
    • /
    • 제40권4호
    • /
    • pp.28-35
    • /
    • 2012
  • 최근 지속 가능한 도시시스템 구축을 위해 신, 재생에너지 시스템에 대한 사회적 관심이 집중되고 있으며, 이에 따른 관련 연구가 활발히 진행되고 있다. 전체 에너지 소비의 40% 이상을 차지하고 있는 건설부문 또한 이러한 경향이 두드러지고 있다. 조경부문도 재생에너지설비가 적용된 다양한 조경시설물이 제작, 설치되고 있으나, 계획, 설계단계에서 활용 가능한 체계적인 연구가 아직 국내에 보고되고 있지 않다. 본 연구는 조경시설물에 재생에너지 시스템을 적용하면서 발생되는 에너지, 경제적 효과를 정량적으로 도출하여 조경계획 및 설계에 활용하고자 한다. 이를 위해 서울, 인천, 대구의 도시공원 내 가로등 전력을 계통연계형 태양광시스템으로 대체하는 스마트 가로등 적용 시나리오를 적용하여 에너지, 경제적 해석을 수행하였다. 전산모의는 NASA Satellite Meteorological Data를 이용한 청정에너지 전산모의 프로그램인 RETScreen$^{(R)}$을 적용하였다. 결과적으로 해당 도시의 기후적 특성에 따라 발전량 및 경제성의 차이를 보였으며, 본 연구결과는 향후 조경계획 및 설계에 건전한 재생에너지 시스템 적용을 위한 의사결정에 활용될 것으로 사료된다.

GIS를 사용한 재생에너지설비 최적 위치 설계에 관한 연구 (A Study on Design of Optimal Location for Renewable Energy Facility Using GIS)

  • 정문선;문채주;장영학;김영곤;이숙희
    • 한국전자통신학회논문지
    • /
    • 제13권2호
    • /
    • pp.357-368
    • /
    • 2018
  • 석유는 지난 100년 이상 원격지 마을의 전력생산을 가능하게 해왔으며, 지속적인 전력공급이 가능한 장점을 갖고 있다. 섬과 원격지 마을에서 석유만을 의존한 전력생산은 몇 가지 위험과 단점을 갖고 있다. 석유를 사용한 발전은 위험한 연료 연계매매 전략을 사용하여 가격의 변동성이 크고 더 비싸지기도 한다. 섬과 원격지 공동체 주민은 미래 기후변화 영향에 대한 우려와 탄소배출의 감축을 위한 대응행동 요구를 주장하기도 한다. 이러한 위험과 단점은 제조업체에서 태양광, 풍력 및 에너지저장장치 기술 등의 단가를 지속적으로 줄여서 극복할 수 있다. 비용을 줄이는 것은 쉬운 일이 아니며, 본 연구에서는 좀 더 다양하고 새로운 재생에너지원 배치를 기반으로 여러 가지 상황에 따른 현장시공 비용을 줄이는 방안을 검토하였다. 본 논문에서는 GIS를 이용하여 재생에너지설비의 최적위치 및 선로 경과지를 가능하게 하는 편리하고 간단한 설계해법을 제안한다. 제안된 방법은 GIS를 사용하여 거문도를 대상으로 구현하였으며 현장조사를 통하여 설계타당성을 확인하였다.

IEC 61850 프로토콜의 배전자동화시스템에 사용을 위한 배전시뮬레이터 개발과 시뮬레이션 결과에 관한 연구 (A study on the development of distribution simulator and simulation results for use in distribution automation system of IEC 61850 protocol)

  • 김재동;오재곤
    • 한국정보전자통신기술학회논문지
    • /
    • 제15권2호
    • /
    • pp.95-102
    • /
    • 2022
  • 신재생에너지 확대를 위한 배전자동화시스템의 안정성 평가를 위한 연구이다. 정부는 재생에너지 3020 이행계획 정책을 통해 2030년까지 신재생에너지를 확대하여 국민의 삶의 질을 높이는 참여형 에너지 체계로 전환할 계획이다. 정부는 2030년까지 재생에너지 발전량 비중을 국내 보급 에너지의 20%로 목표 설정하였다. 신규 설비용량의 95% 이상을 태양광 풍력 등 청정에너지로 설립할 계획이다. 재생에너지 보급 확대로 에너지 신사업과 분산전원 산업이 육성되어 과거의 대규모 전원 개발이 아닌 근거리, 저압, 소규모 발전이 급속히 확대되었다. 이런 수요로 인해 배전 설비 운영의 중요성이 대두 되었고 배전자동화시스템이 필요성 증대되고 있다. 본 논문에서는 배전자동화시스템의 성능 및 기능 평가를 위한 배전시뮬레이터 개발에 대해 다루었고 이와 배전자동화시스템과의 연동시험 결과를 제시한다. 배전계통에 진보된 시스템을 도입하기 위해서는 송변전시스템의 장점을 취해야 한다. 배전시스템에서 DNP3.0프로토콜을 사용하고 송배전시스템에서 IEC61850 프로토콜을 사용한다. 이 두 프로토콜을 배전자동화시스템에서 혼용하여 사용시 제어, 모니터링 등의 운영에 대한 기능과 성능을 충족한다는 결론을 보였다.

대구신서혁신도시 내 공공건축물의 신재생에너지 시스템 도입시 경제성 평가에 관한 연구 (A study on economic evaluation when renewable energy system is introduced in public buildings inside of Daegu Sin-seo innovation city)

  • 김보라;김주영;홍원화
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2009년 춘계학술발표대회 논문집
    • /
    • pp.175-180
    • /
    • 2009
  • According to an increasing demand of political support and development on renewable energy as a solution for the energy problem in Korea, the government has established a goal to raise renewable energy supply from 2.27% to 5% until 2011. Especially in the case of public building in which energy use is in great demand, it would bring a great advantage to develop and utilize the Photovoltaic System as an electric energy and Geothermal Heat Pump System as a thermal energy. On the occasion of Photovoltaic System, Photovoltaic module can be used as an architectural material so that it can reduce construction cost and when we use solar energy, it is possible to make building's own power supply. As for Geothermal Heat Pump System, It can be used infinitely as long as the solar energy exist and operation cost is cheap and yearly efficiency is stable. However, we need to make a plan to reduce early investment expanses for these two renewable energy systems and to expand a diffusion rate as we develop a competitive domestic technology level. So in this study, we are going to perform evaluation of economical efficiency according to the introduction of Photovoltaic System and Geothermal Heat Pump System in public buildings which will be built up inside of Daegu Sin-seo innovation city. As a first step, we will investigate present installation condition of these two renewable energy systems and based upon that, will seek efficient introduction program of renewal energy systems that can be applied in public buildings.

  • PDF

폐CNT와 전도촉진재를 혼입한 시멘트 모르타르 블록의 발열 전도 특성 (Heating Transferring Charcteristics of Cement Mortar Block with Waste CNT and Conduction Activator)

  • 구현철;김운학;오홍섭
    • 한국건설순환자원학회논문집
    • /
    • 제10권2호
    • /
    • pp.176-183
    • /
    • 2022
  • 저전력 사용이 가능한 발열콘크리트를 제작하기 위하여 시멘트 모르타르에 고순도 폐CNT를 혼입하였으며, 모르타르의 전도율을 향상시키기 위하여 압축강도를 제어하는 수준에서 탄소섬유와 폐음극재를 활용하고자 하였다. 사용된 폐CNT는 다중벽 CNT의 함유량이 많은 것으로 분석되었고, 모르타르 배합시 분산성을 높이기 위하여 액상형으로 치환하여 사용하였다. 모르타르 발열시 태양광 등에 의한 소형 자가발전 설비를 활용하고 전자파를 최소화하기 위하여 DC 24 V이하의 전력 사용시의 모르타르의 온도 변화를 평가하였다. 액상형 폐CNT를 적용하고, DC 24 V의 전압을 도입한 경우 200 × 100 × 50 mm 블럭 시험편에서 60 ℃까지 상승하였으며, 액상형 폐CNT와 탄소섬유, 폐음극재를 모두 사용한 경우에는 DC 12 V에서도 55 ℃이상까지 온도가 상승하여 현장 적용성이 충분한 것으로 판단되었다. 특히 발열에너지 변화량에 있어서도 다른 변수들과 비교하여 효과적인 것으로 나타났다.

반도체 & 디스플레이 업종에서 사용되는 독성가스 저감시설의 처리효율 측정방법에 관한 연구 (A Study on the Destruction or Removal Efficiency of Toxic Gas Reduction Facilities in Semiconductor and Display Industries)

  • 장성수;한재국;조현일;이수경
    • 한국가스학회지
    • /
    • 제21권6호
    • /
    • pp.88-95
    • /
    • 2017
  • 국내에서 독성가스의 사용은 반도체, 디스플레이 및 태양광 등 첨단산업의 발전에 따라 증가하고 있는 추세이다. 최근 5년간 국내 독성가스 소비량 현황을 살펴보면 연평균 12% 정도 증가 추세에 있지만, 아직까지 사용에만 관심이 집중되고 있고, 사후 처리나 안전에는 다소 소홀한 것이 사실이다. 2012년 9월 발생한 구미 불산 누출사고는 이러한 안전관리 부재를 단적으로 보여주는 사례이다. 이 사고로 인하여 정부, 업계 및 학계에서는 화학물질(독성가스) 누출사고 등에 대한 관심을 갖게 되었고, 정부 주도로 화학물질안전관리대책 등이 수립되어 추진되어 왔지만 아직까지 안전관리 사각지대가 많은 실정이다. 본 연구에서는 반도체, 디스플레이 업종에서 사용되는 저감설비에서 배출되는 가스상 물질에 대한 처리효율에 대한 효과적인 측정방법을 개발하는 것이 목적이다. 국립환경과학원과 UNFCCC에서 제시하는 반도체 & 디스플레이 업종에서 사용되는 온실가스 저감시설의 처리효율 측정방법 가이드라인에 대해 실증시험을 통해 맹독성가스 시설에도 오차 범위 내에서 적용 가능한지를 살펴보고 맹독성가스 저감시설에 대한 차별화된 효율성 측정 방법을 제시하였고, 독성가스 사고에 대한 선제적 예방을 위해서 독성가스 저감시설 등 안전설비에 대한 제3자 인증제도 도입의 필요성을 제안하였다.

지열에너지의 중장기 정책 포트폴리오를 위한 기술 및 정책적 접근방안 제시 (Technical and Political Issues on Geothermal Energy Policy for Long-term Portfolio)

  • 김기열;김경희;안형준;임혜숙
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.154-154
    • /
    • 2011
  • 화석연료의 가격 및 공급의 불안정과 온실가스감축 국제 규제 강화 등에 대한 대안으로 여기는 신 재생에너지는 높은 초기 투자 부담으로 인하여 관련기술의 연구개발과 보급정책 등 전과정에 걸친 정책 지원체계가 필요하다. 본 연구에서는 지열에너지를 이용하는 지열냉난방기술에 중점을 두고 이에 대한 중장기 정책 포트폴리오 작성을 위한 기술 및 정책적 접근방안을 제시하고자한다. 지열에너지의 가장 큰 특징은 기후 등에 영향을 크게 부하가 변하는 태양광, 풍력 등과 달리 일정한 부하를 유지함으로써 안정적인 에너지공급이 가능하다는 것이다. 또, 품질 측면에서도 화석연료를 이용한 기존의 연료보다 쾌적한 환경을 조성하여 고급에너지로 평가받고 있다. 반면, 설비를 갖추기 위한 천공, 히트펌프 설치 등에 큰 비용이 든다는 단점을 가지고 있다. 현재 히트펌프 제작기술은 국산화를 완료한 상태로 사실상 기술개발에 의한 큰 폭의 원가절감은 기대하기 힘든 상황이다. 하지만, 유사분야인 시스템 에어컨이 표준화 및 대량생산을 통한 시장 보급 확대로 보급단가가 하락한 것을 고려해 볼 때 이를 통한 가격하락은 어느 정도 기대해 볼 수 있을 것으로 생각된다. 에너지 외적인 측면에서 볼 때도 지열에너지의 공급은 상당한 의미를 갖는다. 건물 냉 난방용 이외에 다양한 용도의 개발을 통해 비닐하우스나 온실 등에 지열에너지를 이용할 경우 정부차원에서 농어촌에 대한 지원이 가능하다. 또, 기존의 에너지원을 조달하는데 어려움이 있는 산간, 도서지방에서는 도시지역보다 투자대비 큰 효과를 볼 수 있어 지역간 에너지 불균형 해도에도 도움이 될 수 있다. 이와같은 지열에너지의 특성에 따라 향후 발전방향을 정리해 보았다. 핵심기술인 지열 히트펌프의 산업구조와 시장 보급 확대를 통한 가격하락을 기대한다. 지역개발 및 고립지역에서 타 신 재생에너지와 함께 독립적인 전력, 냉난방 등의 완전 에너지 공급시스템을 갖출 수 있다. 또한 특수 작물 등의 고급 농수산물 생산등의 용도개발을 통해 지열에너지 공급역량을 성장시킬 수 있을 것이다. 이와 함께 중장기 비젼을 제시하기 위해 추진되어야 할 연구과제로는 시장 보급 확대에 따른 가격경쟁력 도달 가능성에 대한 연구를 통해 산업육성 방안 마련, 타 신 재생에너지기술과 복합 설치에 의한 시너지 효과 및 이에따른 초기 투자비 증가에 대한 대책, 보급 잠재량 조사, 지열시스템의 자금 조달 및 관련 정책 검토 등이 있을 수 있다.

  • PDF